MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS STANDARD PROGRAMMABLE THERMOSTAT

Similar documents
MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL ELECTRO-MECHANICAL THERMOSTATS FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL DELUXE NON-PROGRAMMABLE THERMOSTATS THERMIDISTAT: INDUSTRY LEADING TEMPERATURE PLUS HUMIDITY CONTROL

TOTALINE WALL THERMOSTATS

installation and start-up instructions THERMIDISTAT CONTROL

COMFORT CONTROL. Programmable Thermidistat Control Homeowner s Guide

COMFORT CONTROL. Thermidistat Control Homeowner s Guide

Installation Instructions

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Installation Instructions

Installation Instructions

Safety & Installation Instructions

THERMIDISTAT CONTROL. Homeowner s Guide

OWNER S MANUAL Venstar Inc. 08/07

Zone Perfect Plus. Zoning Systems USER S INFORMATION MANUAL. NOTE TO INSTALLER: This manual must be left with the equipment user.

OWNER S MANUAL Venstar Inc. 08/07

User s Manual

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

Safety & Installation Instructions

Evolution Control. Zone Control Homeowner s Guide

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

HEAT COOL. Meets Commercial California Title 24

Advanced Installation and Configuration Instructions

Instruction Guide: Thermostat Operation

Installation Instructions

Safety & Installation Instructions

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions

Bryant 2007 Family of Controls

EL-TSTAT-8820 Safety & Installation Instructions

OWNER S MANUAL Venstar Inc. 08/07

HEAT HEAT HEAT COOL COOL

Owner s Manual. Part Number 33CSCPACHP-01

Installation Instructions

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

395CAV Sizes 045 thru 155 Series H and J

TP-PHP01-A,TP-PAC01-A &TP- PRH01- B Performance Series Programmable Thermostat. Owner s Manual

DAY/TIME Button: Selects hour, minute and day setting.

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat. Table of Contents. Description. Initial Thermostat Power up

Safety & Installation Instructions

COMFORT CONTROL. Programmable Thermostat Homeowner s Guide

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

Must be installed by a trained, experienced technician

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

PerFormance Pro t4900 school series InstallatIon GUIDe

1F Day Day Non-Programmable. Maximum Stages Heat/Cool

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification RHC TST 101 GE MS

Programmable Thermostat

1F Day Day Non-Programmable. Maximum Stages Heat/Cool

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

VisionPRO 8000 with Wi-Fi

ATC32U03 igate Communicating, Programmable Thermostat

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

THERMOSTATS 100-Series NON-PROGRAMMABLE UHC-TST101GESS UHC-TST102HPMS UHC-TST103UNMS

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

7-Day. Digital Thermostat. residential. & 2-cool

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

Installation Instructions

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

Installation and Start-Up Instructions

TP-NHP01-A,TP-NAC01-A &TP-NRH01-B Edger Non- Programmable Thermostat. Owner s Manual

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

User Manual. Universal Programmable Smart Wi-Fi Thermostat. For Systems Up to 3 Heat / 2 Cool with Wireless Humidity Control*

SYST0101CW Product Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications

DAY/TIME Button: Selects hour, minute and day setting.

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Innovation. Simplicity

Operator: Save these instructions for future use!

1F Day Day Non-Programmable. Maximum Stages Heat/Cool

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

ATC32U01 igate Communicating, Programmable Thermostat

T-32-TS Touchscreen Thermostat. Installation Manual

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP

5+2 Day. up to HEAT COOL

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

TC-PHP01-A, TC-PAC01-A Comfort Series Programmable Thermostat. Owner s Manual

Installation and Setup Guide

Universal Programmable Wireless Thermostat Kit. See Wireless Setup Guide for Wireless Setup Instructions Read all instructions before proceeding

OPERATING INSTRUCTIONS

1F Day 5/1/1 Day Non-Programmable. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

PerFormance Pro t12000 series InstallatIon GUIDe

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

Homeowner s Guide / 1

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

Thermostats. Thermostats

Small Digital Thermostat Controller Temperature Control

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

CT1001/CT1002 Touchscreen Programmable Thermostat

Transcription:

THERMOSTATS THERMIDISTAT TM CONTROL MODEL TSTAT BUILDER S MODEL THERMOSTAT * Models (AC, HP) STANDARD PROGRAMMABLE THERMOSTAT * Models (AC, HP) NON-PROGRAMMABLE THERMOSTAT * Models (AC, HP, 2S) PROGRAMMABLE THERMOSTAT, DUAL FUEL, AND THERMIDISTAT TM CONTROL * Models (AC, HP, 2S) * Dual Fuel Model (DF) * Thermidistat TM Control Model (RH) The Bryant electronic thermostat product line consists of programmable and non-programmable air conditioner, heat pump, and 2-speed models; a programmable dual fuel model; and a programmable/non-programmable Thermidistat TM Control. Bryant also offers builder s and standard programmable thermostats in both air conditioner and heat pump models. These units feature non-mercury based electronic controls built into a subtle, slim plastic enclosure. They require no battery back-up. FEATURES/BENEFITS BUILDER S THERMOSTATS COMPLETE OFFERING Non-programmable air conditioner and heat pump models available. EASY TO USE Rubber push buttons provide easy changes to heating/cooling mode operation, fan operation, and desired temperature setting. MANUAL CHANGEOVER Allows manual switches in system operation when both heating and cooling are needed on the same day. STANDARD PROGRAMMABLE THERMOSTATS Bryant Standard Programmable Thermostats posess the same features as the Builder s Thermostats plus: COMFORT AND ENERGY SAVINGS 5-2 Day Programming with four temperature changes per day means comfort for the family. EASY TO READ Large LCD with clock. NON-PROGRAMMABLE THERMOSTATS CLEAN DESIGN Features soft, responsive buttons and an easy-to-read backlit Liquid Crystal Display (LCD). ACCURATE, RELIABLE TEMPERATURE CONTROL LCD shows current room temperature at all times, and desired temperature prompts upon demand. AUTO CHANGEOVER Switches system operation automatically when both heating and cooling are needed on the same day. It can be disabled if not necessary in certain areas of the country. OUTDOOR TEMPERATURE DISPLAY Allows a check of the temperature outside before leaving home. (Optional on heat pump and 2-speed models.) CLEAN FILTER INDICATOR Tells when it is time to clean the system s filter. BATTERY FREE Non-volatile RAM chip requires no battery backup. EQUIPMENT ON INDICATOR On all non-programmable models, HEAT ON or COOL ON indicator is displayed when the heating or cooling equipment is operating. PERFECT COMPLEMENT Completes your Bryant total comfort system needs. LIMITED WARRANTY Standard 1-year warranty available on all parts. PROGRAMMABLE THERMOSTATS Bryant programmable thermostats possess the same features as non-programmable thermostats plus: Form No. PDS TSTAT.0.4

COMFORT AND ENERGY SAVINGS Seven day programming, with 4 temperature changes provided per day, means comfort when the family is at home and savings through reduced energy usage when the family is away or asleep. EASY TO USE Simple instructions are located inside the thermostat s door. DUPLICATE PROGRAMMING Copy the comfort schedule from one day to the next using the copy previous day function. OVERRIDE CAPABILITY Hold function allows the regular schedule to be bypassed with a temporary setting. BATTERY-FREE Non-volatile RAM chip requires no battery backup. Program is retained in memory so reprogramming is not required after power loss. SMART RECOVERY Provides consistent heating right on time as it gradually adjusts indoor temperatures before a scheduled change. TIMEGUARD Equipment protection. DUAL FUEL MODEL The dual fuel thermostat can be used to control a gas furnace and a heat pump. This thermostat eliminates the need for an interface control kit. The outdoor temperature sensor is included. THERMIDISTAT TM CONTROL Bryant s Thermidistat Control can be used to control any equipment application except zoning. It possesses all the features and benefits of Bryant s non-programmable and programmable thermostats plus: ENHANCED COMFORT Allows the homeowner to accurately maintain the desired temperature and humidity settings in the home. By combining the functions of a programmable/nonprogrammable thermostat and a humidistat, the Thermidistat Control provides temperature control, humidity control, and dehumidification. HUMIDITY CONTROL The Thermidistat Control accurately controls humidity. It controls humidification during heating and dehumidification during cooling. AUTOMATIC HUMIDITY ADJUST- MENT When used with the outdoor temperature sensor, the Thermidistat Control automatically adjusts the humidify setting, reducing excess condensation from forming on the windows. VACATION MODE With a single touch of a button, vacation mode adjusts all comfort levels for optimum efficiency while the home is unoccupied or restores the settings to normal upon return. SMART RECOVERY Provides consistent heating and cooling right on time as it gradually adjusts indoor temperatures before a scheduled change. EQUIPMENT ON INDICATOR When the cooling system is operating, the word COOL preceded by a small triangle is displayed below the cooling set point. When the heating equipment is operating, the word HEAT preceded by a small triangle is displayed below the heating set point. If the equipment turn on is being delayed, the triangle and the word will flash. NON-PROGRAMMABLE OPTION Offers the same popular humidity control benefits to consumers who do not need the added benefits of programming. Nine functional buttons, along with the UP and DOWN buttons, make it easy to enter the temperature and humidity set points. The LCD is the largest display on the market for a non-programmable thermostat. MODEL NUMBER NOMENCLATURE ELECTRONIC THERMOSTATS T STAT BB N AC 01 B SERIES QUANTITY AC AIR CONDITIONING HP HEAT PUMP 2S TWO SPEED/TWO STAGE DF DUAL FUEL RH RELATIVE HUMIDITY (THERMIDISTAT CONTROL) B BUILDER'S MODEL S STANDARD PROGRAMMABLE P PROGRAMMABLE N NON-PROGRAMMABLE BB BRYANT BRAND THERMOSTAT A99046 As an ENERGY STAR Partner, Bryant Heating & Cooling Systems has determined that the programmable thermostats and programmable Thermidistat Control meet the ENERGY STAR guidelines for energy efficiency. 2

DIMENSIONS 3 4 2 3 4 4 1 4 Builder's Model Thermostat 3 4 3 1 2" 5 1 2" Standard Programmable Thermostat 1 3 8 3 1 2 5 13 16 Non-Programmable Thermostat 1 3 8 4 3 8 7 3 8 Programmable Thermostat and Thermidistat Control A99224 3

PRODUCT DATA INFORMATION PHYSICAL CHARACTERISTICS Builder s/standard Programmable Models: Dimensions: See drawing Appearance: Plastic, designer white, textured, white rubber push buttons Non-Programmable/Programmable Models: Dimensions: See drawing Appearance: Plastic, eggshell color, textured ELECTRICAL CHARACTERISTICS Builder s/standard Programmable Models: Input Volts/Amps: 24vac, 1 VA Non-Programmable/Programmable Models: Input Volts/Amps: 24vac, 5 VA ENVIRONMENTAL REQUIREMENTS: Operating Temperature/Relative Humidity: 32 F (0 C) to 104 F (40 C), 95% rh non-condensing Storage Temperature/Relative Humidity: 40 F ( 40 C) to 134 F (56 C), 95% rh non-condensing PROGRAM SPECIFICATIONS: Builder s/standard Programmable Models: Temperature set point range: 50 F (10 C) to 90 F (32 C) Manual changeover Non-volatile memory Fahrenheit or Celsius selectable Power-stealing option on AC model Selectable fan ON or OFF with auxiliary heating (HP model) Five-minute compressor timeguard Four cycles per hour maximum Auxiliary heat LED on heat pump models Non-Programmable Models: Temperature set point range: 40 F (4 C) to 90 F (32 C) Separate heat and cool set points Auto changeover can be disabled Clean filter reminder: installer adjustable Permanent memory Equipment On indicator Programmable Models: Temperature set point range: 40 F (4 C) to 90 F (32 C) Separate heat and cool set points Auto changeover can be disabled Clean filter reminder: installer adjustable Permanent memory Programming days: 7 day Programming periods: 4 Wake, Day, Eve, Sleep Hold function Copy previous day function Humidity display and control (Thermidistat Control only) Equipment On indicator (Thermidistat Control only) WIRING REQUIREMENTS: Power: 24vac nominal, 18- to 30-vac, 50/60 Hz Wiring: Standard thermostat wire 18 to 22 gage. 4

BUILDER S MODEL THERMOSTATS TSTATBBBAC01-B* TSTATBBBHP01-B Thermostat, Air Conditioner, Non-Programmable, 1-Stage Heat/1-Stage Cool, Manual Changeover, F/ C Thermostat, Heat Pump, Non-Programmable, 2-Stage Heat/1-Stage Cool, Manual Changeover, F/ C * Furnace model numbers 355MAV, 373LAD, 383KAD, 394HAD, 396HAD, 361A, 362A, 363A, 367A, 369A, and 349MAV; and the Thermostat Conversion Kit are not compatible with these thermostats. Do not use in zoning applications. STANDARD PROGRAMMABLE THERMOSTATS TSTATBBSAC01* TSTATBBSHP01 Thermostat, Air Conditioner, 5-2 Day Programmable, 1-Stage Heat/1-Stage Cool, Manual Changeover, F/ C Thermostat, Heat Pump, 5-2 Day Programmable, 2-Stage Heat/1-Stage Cool, Manual Changeover, F/ C * Thermostat Conversion Kit is not compatible with these thermostats. Do not use in zoning applications. NON-PROGRAMMABLE ELECTRONIC THERMOSTATS TSTATBBNAC01-B TSTATBBNHP01-B TSTATBBN2S01-B Thermostat, Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat/1-Stage Cool Thermostat, Auto Changeover, Non-Programmable, F/ C, 2-Stage Heat/1-Stage Cool Thermostat, Auto Changeover, Non-Programmable, F/ C, 2-Stage Heat/2-Stage Cool in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode PROGRAMMABLE ELECTRONIC THERMOSTATS TSTATBBPAC01-B TSTATBBPHP01-B TSTATBBP2S01-B TSTATBBPDF01-B* TSTATBBPRH01-B* Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat/1-Stage Cool Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 2-Stage Heat/1-Stage Cool Thermostat, Auto Changeover, 7-Day Programmable, F/ C, 2-Stage Heat/2-Stage Cool in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode Dual Fuel Thermostat, Includes Outdoor Air Temperature Sensor Thermidistat Control Non-Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) * Do not use in zoning applications. THERMOSTAT ACCESSORIES TSTATXXSEN01-B* TSTATXXNBP01 TSTATXXPBP01 TSTATXXBBP01 TSTATXXSBP01 TSTATXXCNV10 Outdoor Air Temperature Sensor Backplate for Non-Programmable Thermostat Backplate for Programmable Thermostat and Thermidistat Control Backplate for Builder s Thermostat Backplate for Standard Programmable Thermostat Thermostat Conversion Kit (4 to 5 wire) 10 pack * Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder s and standard programmable thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat. This plate is designed to cover surrounding wall area located behind thermostat. Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. Do not use this kit with the AC model of the Builder s or Standard Programmable thermostat. 5

THERMOSTAT AND THERMIDISTAT CONTROL APPLICATION NON-PROGRAMMABLE THERMOSTAT USAGE Air Conditioner INDOOR UNIT 1 Speed 2 Speed 1 Speed 2 Speed 1-Stage Furnace Model AC or HP* Model 2S Model 2S 2-Stage Furnace Model AC or HP* Model 2S Model 2S Typical Fan Coil Model AC or HP* Model 2S Model HP Model 2S FK, FV Series Fan Coil Model AC or HP* Model 2S Model HP Model 2S * Model HP thermostat must be field converted to air conditioner operation. Must use Programmable Dual Fuel Thermostat or Thermidistat Control in this application. Dual Fuel operation controlled by heat pump when using Model 2S Thermostat. OUTDOOR UNIT Heat Pump Non-Programmable Models The TSTATBBNAC01-B Thermostat provides single-stage, non-programmable heat/cool temperature control for 24-vac heatingcooling systems with auto changeover. Temperature display can be selected to read F or C. The TSTATBBNHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, non-programmable temperature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read F or C. Thermostat comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can easily be converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat. The TSTATBBN2S01-B Thermostat provides versatile multiple stage, non-programmable heat/cool temperature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read F or C. Thermostat is designed for 2-speed compressor bearing units. Thermostat comes factory set to operate as a heat pump model with 2-stage cooling and 3 stages of heat (third-stage controlling auxiliary electric heat). This model can easily be converted from heat pump operation to air conditioning operation requiring 2 stages of cooling and 2 stages of heating. PROGRAMMABLE THERMOSTAT USAGE OUTDOOR UNIT Air Conditioner Heat Pump INDOOR UNIT 1 Speed 2 Speed 1 Speed 2 Speed 1-Stage Furnace Model AC or HP* Model 2S Model DF Model DF or 2S 2-Stage Furnace Model AC or HP* Model 2S Model DF Model DF or 2S Typical Fan Coil Model AC or HP* Model 2S Model HP Model 2S FK, FV Series Fan Coil Model AC or HP* Model 2S Model HP or 2S Model 2S * Model HP thermostat must be field converted to AC operation. For use with special 3-stage electric heat setup. Dual Fuel operation controlled by heat pump when using Model 2S thermostat. Programmable Models The TSTATBBPAC01-B Thermostat provides single-stage, 7-day programmable heat/cool temperature control for 24-vac heatingcooling systems with auto changeover. Temperature display can be selected to read F or C. The TSTATBBPHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, 7-day programmable temperature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read F or C. Thermostat comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can easily be converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat. The TSTATBBP2S01-B Thermostat provides versatile multiple stage, 7-day programmable heat/cool temperature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read F or C. Thermostat is designed primarily for 2-speed compressor bearing units. Thermostat comes factory set to operate as a heat pump model with 2-stage cooling and 3-stages of heat (third-stage controlling auxiliary electric heat). This model can also perform intelligent heatstaging with FK & FV fan coils (special heaters and setup required) using a single-speed heat pump with 3-stages auxiliary electric heat. In addition, this model can easily be converted from heat pump operation to air conditioning operation requiring 2 stages of cooling and 2 stages of heating (e.g. gas or electric heat). 6

Programmable Dual Fuel Model The TSTATBBPDF01-B Thermostat provides single-stage or multiple-stage dual fuel operation, 7-day programmable heat/cool temperature control for 24-vac systems with auto changeover. Temperature display can be selected to read F or C. The Dual Fuel Thermostat is designed with separate lockout temperatures for the furnace and the heat pump. The furnace is prevented from operating above its lockout temperature and the heat pump is prevented from operating below its lockout temperature. Thermostat comes factory set to operate single-speed equipment, but is easily configured to match multiple stage equipment combinations. This model requires use of the Outdoor Air Temperature Sensor accessory, which is included with the Dual Fuel Thermostat. Using the dual fuel thermostat eliminates the need for an interface control. THERMIDISTAT CONTROL USAGE INDOOR UNIT 1-Stage Furnace 2-Stage Furnace Typical Fan Coil FK, FV Series Fan Coil OUTDOOR UNIT Air Conditioner Heat Pump 1 Speed 2 Speed 1 Speed 2 Speed Model RH* * The Thermidistat Control may be used in all applications but must be field configured for specific application. Thermidistat Control The TSTATBBPRH01-B Thermidistat Control provides single-stage or multiple-stage equipment operation, 7-day programmable heat/cool temperature control for 24-vac systems with auto changeover. It controls both humidification and dehumidification and can be used to control heat pumps, air conditioners, or dual fuel applications. Temperature display can be selected to read F or C. The Thermidistat Control is designed primarily as an extension of the programmable thermostat line to provide humidify and dehumidify outputs in controlling humidity. It can also be field configured to be non-programmable. Humidify outputs connect directly to 24-v humidifiers. Dehumidify outputs connect directly to variable-speed furnaces or fan coils that have dehumidification capabilities. To achieve full benefits, this model requires use of the Outdoor Air Temperature Sensor accessory, which is included with the Thermidistat Control. The Thermidistat Control will deliver Perfect Heat Plus mode when matched with variable-speed equipment. 7

FIVE-MINUTE COMPRESSOR TIMEGUARD OPERATIONAL INFORMATION This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the FAN mode button and INCREASE TEMPERATURE (UP) button. FIFTEEN-MINUTE CYCLE TIMER This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle. Its function is to assure that equipment is not cycled more than 4 times per hr. This timer is defeated for 1 cycle when the desired temperature is manually changed. It can also be defeated for 1 cycle by simultaneously pressing the FAN button and the INCREASE TEMPERATURE button. FIFTEEN-MINUTE STAGING TIMER In multistage heating or cooling, this timer prevents any higher stage from turning on until preceding stage has been on for 15 minutes. This timer is defeated if temperature error is greater than 5 F (usually due to a large change in desired temperature). MINIMUM ON TIME In normal operation, when a stage turns on, it will not turn off for a minimum of 3 minutes (2 minutes on Builder s model). HEAT/COOL SET POINTS (DESIRED TEMPERATURE) A minimum difference of 2 F is enforced between heating and cooling desired temperatures. This is done by allowing one setting to push the other, to maintain this difference. (Thermidistat Control is adjustable.) Builder s thermostats are controlled by a single set point. EQUIPMENT ON INDICATORS (NON-PROGRAMMABLE MODELS) When cooling equipment is ON, a COOL ON icon is displayed above the room temperature display. When heating equipment is ON, a HEAT ON icon is displayed above the room temperature display. EQUIPMENT ON INDICATORS (THERMIDISTAT CONTROL) When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool set point. While cooling equipment turn on is delayed by a staging or cycle timer, the triangle and the word COOL will flash. The same is true for the HEAT icon and its preceding triangle located under the heat set point. The 2 triangles are also used to indicate the state of the humidify and dehumidify outputs. See next section. HUMIDIFY/DEHUMIDIFY OUTPUT ON INDICATORS (THERMIDISTAT CONTROL) Within humidity select screen (selected by Humidity button and indicated by hu or dhu on clock display), the triangle under humidity set point will be on while humidify output is on. The triangle under dehumidify set point will be on while dehumidify output is active (turned off, because this output is reverse logic). AUTO CHANGEOVER When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode demand has existed for 20 minutes. If set point is changed, the 20 minute requirement is deleted. Auto changeover mode can be disabled. Builder s and Standard Programmable thermostats are manual changeover. EMERGENCY HEAT MODE When thermostat is controlling as a heat pump and emergency heat is selected, all Y signals are locked out, and W becomes energized upon a call for heat. SMART RECOVERY (PROGRAMMABLE MODELS) With Smart Recovery selected, transition out of setback begins a fixed time period before selected recovery time and gradually adjusts room temperature so that the desired temperature will be achieved at selected recovery time. ROOM TEMPERATURE OFFSET (ALL MODELS) Room temperature may be deliberately offset by up to 5 F in either direction. MAXIMUM ON/OFF DEADBAND Maximum sensed temperature difference between ON and OFF is 0.8 F for Builder s thermostats and 0.6 F for all other models. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS TSTAT.03 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 8 PRINTED IN U.S.A. Catalog No. 12TS-TA4 7-99