HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Similar documents
FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

FACTORY AUTOMATION HANDBUCH / MANUAL / MANUAL / MANUALE

MANUAL Overflow sensor NVF-104/34-PF

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

MANUAL Oil Level Sensor

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

Sensing light curtain as per DIN 18650/EN 16005

Sensing light curtain as per DIN 18650/EN 16005

Vibracon LVL-A* Level limit switch for liquids, compact design

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

Laser Distance Sensor Type M Analog-Output

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

English. Series. Installation and Use Manual

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

DUAL OPTIC. Installation manual

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Table of Contents. 1. Mounting Tips... 2

FACTORY AUTOMATION SENSE WITH SIMPLICITY FIBER OPTIC SENSORS AND FIBER OPTIC CABLES

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

Retroreflective sensor with polarization filter

COMPACT FLAME CONTROLLER CFC 100

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Fireray 2000 Linear Smoke Detector

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Topscan G3 Presence detector for automatic doors

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

E3M-V. Mark Sensor. Applications

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

FSLIMPRO

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Apollo Intelligent Auto Aligning Beam Detector. User Guide

HDCVI PIR Camera User s Manual

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

/ / 2018

PROCESS AUTOMATION PROGRAMMING TREE 6000 SERIES PURGE/PRESSURIZATION SYSTEM

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

SCHMIDT LED Measured Value Display MD Instructions for Use

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

FIRERAY 5000 range USER GUIDE

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Snifter ATEX22 VERSION. User Manual. Distributor

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

Retroreflective sensor with polarization filter

FlowJam Bulk Flow Detection

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

OPTISENS TUR 2000 Technical Datasheet

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Motorised Infrared Optical Beam Smoke Detector. User Guide

IR LED Light Emitter - 12 watts - 4 LEDs - 90'L X 70'W beam Volts DC - 750/850/940Nm

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

Original operating instructions Safety switch with guard locking AC901S AC902S

REA 105 Arc Protection Module. Operator s Manual

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

FACTORY AUTOMATION EXPERIENCE HYGIENIC DESIGN SENSORS FOR THE FOOD AND BEVERAGE INDUSTRY

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

CONTROLS INSTRUCTIONS MANUAL ENGLISH

Motorised Infrared Optical Beam Smoke Detector. User Guide

Dräger Polytron 8720 IR Detection of carbon dioxide

Operating Instructions

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

LS800S Intruder Alarm System. Engineering Manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

Dräger Polytron 5720 IR Toxic Gas Detection

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

COMPACT FLAME CONTROLLER CFC 1000

SYSTEMS PRODUCT OVERVIEW

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

PVL1300 INSTRUCTIONS FOR USE

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

GEZE AUTOMATIC DOOR SYSTEMS GEZE ACTIVATION DEVICES AND SENSOR SYSTEMS PERFECTLY CONTROLLED AUTOMATIC DOOR DRIVES BEWEGUNG MIT SYSTEM

Temperature Sensor TRG Original Installation Instructions English

Synchronous Detector

Turbimax CUE21 / CUE22

Stripping machine AI 01

Transcription:

FACTORY AUTOMATION HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S Certification Type Tested

Inhalt / Content / Sommaire / Indice Deutsch......................................................... 3 English......................................................... 15 Français........................................................ 27 Italiano......................................................... 39 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship" Ausgabedatum 28.05.2008 Part No. 194964

Table of Contents and General Information 1 Design of the Device............................................. 16 2 Functional Description............................................ 17 2.1 Principle of Operation...................................................... 17 3 Installation and Initial Operation.................................... 17 3.1 Installation Check List..................................................... 17 3.1.1 Installation of Aluminum Profile................................................ 17 3.1.2 Installation of the Module.................................................... 18 3.2 Setting the Monitoring Beam - Leading Edge.................................. 18 3.3 Optical Setting of the Sensor................................................ 19 4 Sensing Field................................................... 20 5 Master / Operation.......................................... 21 5.1 Difference between Master and Modules................................. 21 5.2 Installing Master / Modules............................................ 21 5.3 Removing the Configuration Bridge.......................................... 21 6 Test........................................................... 22 6.1 Pulse Diagram of Time Sequence............................................ 22 7 Connection to the Door Controller.................................. 22 8 Troubleshooting................................................. 23 9 Specifications / Wiring Diagram.................................... 23 9.1 Wiring Diagram........................................................... 24 10 Components of TopScan-S........................................ 24 11 Disposal, Repair, Maintenance..................................... 25 11.1 Disposal................................................................. 25 11.2 Repair................................................................... 25 11.3 Servicing................................................................ 25 DIN This symbol points out German standard DIN 18650 to the user. All points described there are required to fulfill German standard DIN 18650. This symbol points out important notes to the user. Date of issue 05/28/2008 Part No. 194964 Declaration of Conformity We, Pepperl+Fuchs GmbH, herewith declare out sole responsibility for the fact that Active Infrared Scanner TopScan-S and all models of the product have been developed and manufactured under observation of the applicable European standards and directives. DIN The Active Infrared Scanner TopScan-S has been certified in keeping with German standard DIN 18650. 15

Design of the Device 1 Design of the Device Figure 1.1 Internal design of the device Figure 1.2 Design of the master module Figure 1.3 Design of the slave module Figure 1.4 Connection of two modules a b c d e f g h i j k l m n o q Removable housing cover Aluminum profile Module holder Handle to set the detection angle (chassis lever) LED for status indication Screw for sensing range adjustment Screw to secure the detection angle Screw M2.5 to secure the module holder Terminal block for supply voltage, output and test input Configuration bridge Infrared transmitter Infrared receiver Flat cable Module connector Profile seal End caps Figure 1.5 Installation of the module holder and of the profile seal 16

Functional Description 2 Functional Description The TopScan-S is an active infrared triangulation scanner. The TopScan-S has been designed for sensing while mounted on a swinging door panel. DIN The intended use of TopScan-S is to make safe automatic swinging doors in complying with German standard DIN 18650. If used as intended, the sensor shall influence the door movement through the safe door control only and not by direct intervention, as only using the safe door controller and the sensor together constitutes a protective device of EN ISO 13849-1:2006 Performance Level "c" Categorie 2. The modification of the construction/ arrangement of the installation without consultation with the manufacturer could lead to dangerous situations. 2.1 Principle of Operation Any objects entering the protected area will be detected by the infrared beams and will cause the relay output to be switched off. The beam spot produced by the infrared beam on the ground is approx. 1,1 cm x 8,3 cm in size (at a mounting height of approx. 2 m). The angle of the two lens systems can be modified by an adjustment mechanism. A sensor mounting height of up to a maximum of 2.50 m can be set. The sensing range of the device is set to maximum at the factory. The device includes an optical adjusting tool. The sensor detects objects in its sensing field with little to no influence by the targets' color and surface finish. Reflective and very dark objects are detected as well. Several sensors can be operated in a master and slave combination in order to adapt the protected area to the application's required sensing area (cf. Chapter 7). By means of a six-position screw terminal, the master module is connected to the door controller. The slave modules are connected to the master module by means of flat cables. The master module and the slave modules are located in an aluminum profile together. 3 Installation and Initial Operation 3.1 Installation Check List 3.1.1 Installation of Aluminum Profile 1. Push the module holder (c) into the aluminum profile (b) and position the module holder at the points where the modules will be mounted later. 2. Drill the mounting holes in the aluminum profile between the module holders (in Fig. 3.1 gray surface). Make sure that no chips remain in the aluminum profile. Seal the borehole when mounting so that dripping water cannot penetrate the housing. Mechanical information which may facilitate positioning the screws: 0 mm 100 mm 290 mm 480 mm 670 mm 860 mm 100 mm 190 mm 190 mm 190 mm 190 mm Figure 3.1 Mounting the aluminum section 3. Only use flat-head screws to mount the aluminum profile (b) at the intended mounting height (maximum 2.50 m). Sawing recommendation for aluminum and plastic profiles: Use a miter-box saw with a hack saw blade for both profiles. Make sure that the plastic profile rests with the convex side facing outwards. Saw carefully (risk of breakage). The aluminum profile is non-critical during machining. 17

Installation and Initial Operation 3.1.2 Installation of the Module 1. Set the transmitters of the modules identically on all modules to be used (see Figure 3.3). -> For example, move all of the transmitter adjustments towards the hinge (the hinge side is opposite the leading edge). 2. Connect all required flat cables to the modules prior to the installation of the modules. -> Use the long flat conductor cable (24 cm) for the master module and the short flat conductor cable (20 cm) for the slave module. 3. Please make sure that the master module is always located on the door's hinged side. 4. Connect the screw terminals (i) of the master module to the connection cable of the door controller. 5. Place the module holders into the Aluminum profile. 6. Place the modules between the module holders (c). Then use the headless screw (h) to screw the modules down to the module holder (see Figure 1.1). 7. Use cutters to cut the configuration bridge (j) out of the PCB of the last module (last slave module or individual master module) (see Chapter 5). 8. Set the detection angle and the sensing range as indicated in Chapter 3.2. 9. Replace the housing cover (a). 10. Screw down the end caps. 11. Finally, check the sensing range for each beam. The connection cable to the door control er can be passed through the end cap by means of a cable bushing. The optional section seal (o) can be used to seal the TopScan-S section to conform with IP54. 3.2 Setting the Monitoring Beam - Leading Edge Designate either the transmitting light beam or receiving light beam as vertical to optimize coverage of the door's leading edge. Position 1 Position 2 leading edge Transmitter Transmitter leading edge Figure 3.2 Explanation of the monitoring beam setting at the leading edge Adjust the transmitter for left-justified or right-justified monitoring of the main leading edge. (see Figure 3.3.). Figure 3.3 Setting the monitoring beam to the leading edge In the factory default setting, all transmitter modules are preset to position 1 and to a sensing range to maximum. Position 1 means that the transmitter beam is straight and the main leading edge is on the left (see Figure 3.2 left). Make sure that all modules (including the master) have identical transmitter settings on their lock positions. 18

Installation and Initial Operation 3.3 Optical Setting of the Sensor You can swivel the sensing field away from the door or towards the door by setting the detection angle. The detection angle can be adjusted from 0 to + 25. Use the handle on the chassis (d) to set the detection angle. To adjust the detection angle, use the M3 screw (g) at the top of the module holder. 25 0 Figure 3.4 Setting the detection angle Use the sensing range screw (f) to adjust the sensing range. By turning the sensing range screw (f) with a screwdriver, the receiver lens is shifted and the sensing range is set. A bi-color status LED (p) assists in setting the exact sensing range over the ground. If the sensor is not used for protection in complying with German standard DIN 18650, a higher adjustment (no more than 80 cm) is possible. Figure 3.5 Adjustment of the sensing range LED display: LED red: Object has been detected. LED green: Sensing area is unobstructed, and the sensor sees the ground. DIN If used as a means of protection in complying with German standard DIN 18650, the detection angle and the sensing range have to be adjusted as follows: Use the optional calibration tools (test card and square) for adjustment. Sensing range adjustment of the Sensor: 1. Use the chassis lever to move the module to the first marked line on the module holder (see Figure 5.2), and use the M3 screw to fasten (g). 2. Turn the sensing range adjustment screw (f) counterclockwise until its overturn protection is activated (slight "clicking" noise). Now the maximum sensing range has been set. 3. Now place the test card on the test specimen so that the card lays 12.5 cm above the ground. 4. Turn the sensing range adjustment screw clockwise just until the LED display switches from red to green (if necessary turn back to red and then clockwise to just to green). The sensing range adjustment is thus completed. Figure 3.6 Sensing range adjustment (left) and detection angle (right) 19

Sensing Field Detection Angle of the Sensor: 5. Lay the test card on the ground with its mark parallel to the door. 6. Place the test specimen on the door-side of the test card mark. (see Figure 3.7). 7. Aim the sensor down vertically. 8. Use the chassis lever to swivel the sensor forward until it detects the test specimen (20 cm height) and the red LED illuminates. 9. Swivel the sensor's light beam slowly further away from the door sees the ground again (LED switches from red to green). 10. Now use the M3 screw (g) to attach the module to the module holder. The detection angle has now been set. This setting has been competed now. Checking the Sensing range adjustment 11. Use the test card to check the sensing range adjustment once again. 20 cm 12 Mark on test card DIN Figure 3.7Positioning the test specimen For operation as a safety sensor in complying with German standard DIN 18650, the sensing range has to be set to approx. 12.5 cm ± 1 cm over the ground. 4 Sensing Field Depending on the application and the door width, a master module can be supplemented with up to seven slave modules. We recommend to adjusting the straight (vertical) transmitting / receiving beam of the corresponding sensor module no further than 10 cm away from the main leading edge..figure 4.1 illustrates the installation for different door panel widths. 750 mm Master 900 mm Master 1400 mm Master closing edge 100 mm 750 mm Width of door panel 900 mm Width of door panel 1400 mm Width of door panel Figure 4.1 Sensing field The wider the door panel is, the more slave modules are required. 20

Master / Operation 5 Master / Operation 5.1 Difference between Master and Modules It is possible to add up to seven additional slave modules together with one master module. The differences between the master module and the slave module are as follows: Master module: with relay; 6-pole connector; one red socket module: no relay; no 6-pole connector; two red sockets 5.2 Installing Master / Modules Make sure that the chassis neatly locks into the module holder during the installation of the master module and the slave module. Figure 5.1 Master / slave modules The chassis has to lock into the module holder as follows: Figure 5.2 Installing master / slave modules Please make sure that the module holder's stem locks into the borehole of the chassis safely. The chassis clip has to be visible in the middle of the module holder (See inside circle of Figure 5.2). Connect only the master module to the door controller via the 6 position screw terminal (i). Connect the slave modules with the 20 cm flat cables. The connection from the master module to its adjacent slave module is made by the longer flat cable (24 cm). 5.3 Removing the Configuration Bridge Disconnect the configuration bridge (j) at the last slave module or on the last slave module's PCB or on the master module's PCB. Disconnect the bridge when the sensor is not powered. Before carrying out this step, touch the chassis lever. Figure 5.3 Configuration bridge 21

Test 6 Test DIN The following test should be conducted only when used as a safety sensor of the door controller in complying with German standard DIN 18650. 6.1 Pulse Diagram of Time Sequence If the TopScan-S is used as a safety device, the device has to be tested cyclically by the door controller. This test should be conducted only if no object is detected, and the recommended door position for the test is completely open. The door controller's test signal should be connected to the master module's 6-position screw terminal only. Test Description: Time t 0 : The door controller sends the test request input. Time t 1 : After a response time of no more than 70 ms, the sensor output must go into detection mode. Time t 2 : After 200 ms, the sensor output must remain in detection mode. The test input signal can now be turned off by the door controller. The test is now completed. After another 70 ms, the sensor will be available again. Test on Max. response time Still detecting Test off Test completed TE Impulse (Test Input) Test response good Bad test responses Response time exceeded Fault Relay does not stay off Fault Relay does not switch Fault t 0 t 1 t 2 t 70 ms 200 ms 70 ms Figure 6.1 Pulse diagram of time sequence The door controller sends signals to the sensor at the times t 1 and t 2. 7 Connection to the Door Controller The inside and outside of the door has to be switched on and off alternately (muting) -> or has to be excluded from the evaluation of the door control. If the device is not used as a safety sensor in complying with German standard DIN 18650, the test input can be left unconnected. If the modules on the inside and outside of the door are connected to a door transitioncable, special cable ties (e.g.: 3M Scotchlok single core tie UB2) are recommended where another cable can be added to the supply cable. 22

Troubleshooting 8 Troubleshooting Error Cause Remedy The sensor does not initialize or react. Supply voltage is not correct. Check the voltage supply. The sensor is disturbed by the Door stops cyclically. movement of the door. Change the sensor's detection The door panels are detected by angle. the sensor. Check the sensor's mounting. The door movement causes vibrations. Door stops sporadically. There are objects in the detection Remove the objects (flags, plants, Test specimen is not detected. Table 8.1 Troubleshooting field which move in the wind. The sensing range is incorrectly set. The detection angle is incorrectly set. etc.) Check the sensing range with the test card. Readjust the detection angle (see Chapter 3.3). 9 Specifications / Wiring Diagram General data Sensing range min. 0... 1,500 mm... Sensing range max. 0... 2,500 mm... Light transmitter IRED Black/white differential (6 % / 90 %) < 1 % at a sensing range of 2,000 mm Approvals CE, TÜV Number of beams Number of mounted sensor modules () Mode of operation Background evaluation Diameter of the light spot 1,1 cm x 8,3 cm at a range of 2,000 mm for each module Displays/operating elements LED LED red / green (see chapter "Optical Setting of the Sensor") Operating components Sensing range adjustment Electrical data Supply voltage 24 VDC ± 20 % Current Consumption I 0 Master: < 75 ma : < 65 ma Input Test input -3 V... +5 VDC or disconnected: Test off +11 V...+30 VDC Test on Output Output type Relay switched off when objects are inside the sensing range. Signal output 1 Form C Relay Switching voltage 5 V... 30 VAC / VDC Switching current 0.001 ma... 0.3 A Response time 70 ms Maximum length of the interconnecting cables 30 m Wire diameter 0.3 mm... 1.3 mm (16AWG - 26AWG) Cu single/multicore Optical data Light wavelength 875 nm ± 15 nm Laser class 1 Minimum reflection of the floor 6 % Minimum reflection of the target 0 % 23

Components of TopScan-S Standards of Conformity Standards EN 60947-5-2 / EN 61000-6-3 / EN 12650-1 / EN 12978 Standards EN 61000-6-2 without EN 61000-4-5 / EN 61000-4 / EN -11 Standards DIN EN 18650-1 / EN 954-1 / EN 60825-1 / EN 61508 Ambient conditions Ambient temperature -10 Celsius... 50 Celsius (263 K... 323 K) Humidity at 20 Celsius < 90 % Humidity at 60 Celsius < 50 % Mechanical data Housing length L min. 310 mm Mounting height max. 2,500 mm Protection type IP52, with optional rubber seal IP54 Connection Screw terminal Material Housing Aluminum / ABS Light exit PMMA Table 9.1 Technical data 9.1 Wiring Diagram 1 2 3 4 5 6 - + TE Pin Assignment 1 GND (0 V) 2 V+ (+24VDC +/- 20%) 3 Relay output - common 4 Relay output - Normally closed 5 Relay output - Normally open 6 Test input Explanation: Relay: Relay is inactive for target presence Relay is active in for target absence Test input: Test input is inactive when signal is -3 V DC to +5 V DC or disconnected Test input is active when signal is +11 V DC to +30 V DC 10 Components of TopScan-S Part Numbers Description 208177 MASTER 208178 SLAVE Table 10.1 Components of TopScan-S 24

Disposal, Repair, Maintenance 11 Disposal, Repair, Maintenance 11.1 Disposal Dispose of the device according to the applicable national laws and regulations. For example, take the sensor to an electronic waste collection center. 11.2 Repair Device may be repaired by the manufacturer only. 11.3 Servicing Observe the applicable national regulations for servicing. The sensor requires little to no maintenance. Nonetheless, check the technical safety of the sensor system in regularly intervals, looking out for damage to the housing in particular. If safe operation is no longer possible, the sensor system should be shut down and secured against unintentional operation. Check the sensor for soiling occasionally. To clean the sensor, use a dry or moist soft cloth to wipe across the sensor regularly. This will ensure optimal function. The housing is made of plastic. For this reason avoid contact with acetone and detergents containing solvents. 25

Disposal, Repair, Maintenance 26

Ausgabedatum 28.05.2008 Part No. 194964 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

FACTORY AUTOMATION SENSING YOUR NEEDS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio 44087 USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany DOCT-1199B 194964 05/2008