More than twenty years Hungarian experience in one pipe heating system renovation

Similar documents
1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

1year. The natural connection between energy savings and a balanced two-pipe system.

3 years payback time. Millions of reasons to choose the best.

The solutions are here The choice is yours...

3 years payback time. Millions of reasons to choose the best. Energy Demands? Comfort Problems? Maintenance Concerns?

District Heating Fact Finding Mission to DK for Energy Cities members September Experience with Low temperature DH in DK

20% Drive energy efficiency and increase customer satisfaction. asv.danfoss.com. ASV automatic balancing valves

Danfoss the world s biggest producer of radiator thermostats

61% Smart heating optimization increases your building s lifetime value. asv.danfoss.com. ASV automatic balancing valves

New ways of balancing two-pipe systems

Automatic balancing valves ASV-PV (new generation) DN 32-50

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

The simple solution to a daily challenge

The simple solution to a daily challenge

Secondary systems used in Europe.

Find out more visit speedfitufh.co.uk or call Take control with JG Aura Wireless TRV & Heating Controls. speedfitufh.co.

Increase the attractiveness of your multi-family building

Heating Control Danfoss Link & Connect Thermostats

Hydraulic balance in a district cooling system

A: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance.

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Installation and operation manual for mixing modules FH-MJB and FH-MJC

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

Technical paper Hydraulic balance in a district cooling system

Thermostatic Radiator Valves (Caleffi)

Energy efficient swimming pools 1.1 A SMART, EFFICIENT CLIMATE SHELL REFURBISHMENT SOLUTION

UNDERFLOOR HEATING GUIDE

Technical paper Selection of district heating house stations

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Domestic Central Heating Market Report - UK

SOLAR COMBISYSTEMS IN DENMARK - THE MOST COMMON SYSTEM DESIGNS

PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES

Distribution systems in apartment buildings

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

Systems engineering Slide 1

WP4.3.3 Water distribution and users behavior Analysis Report Wrocław

Wall-mounted substation PKL-113

INSTALLATION AND OPERATION MANUAL

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

Retailers save up to EUR a year on excess heat from refrigeration units

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

SAUTER Valveco compact. A pressure-independent multi-function valve

GreenCon On/Off Room Thermostat

Heating Installation Guide published by

GreenCon On/Off Room Thermostat

Correcting Low T in Buildings with District Cooling

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

Variable Speed Drives: Reducing the energy costs of commercial HVAC systems

Your guide to. Biomass Heating Systems

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

Introduction to Danfoss

D8) Saving water and energy on water systems. W.G. van der Schee (1) Abstract. Keywords. 1 Introduction. (1)

Weather compensated flow temperature control of heating and boiler systems

HW 22 District heating substation for indirect heating and domestic hot water systems

RA2000 Commercial TRVs

MAKING MODERN LIVING POSSIBLE. Danfoss Floor Heating. For any imaginable application We have you covered

Versa- Hydro. up to 96% Efficient

Combined Space and Water Heating: Making it Work

ECL Comfort 110, application 130

Q - Series Boiler. Troubleshooting Manual

The Possibilities of Applying Mobile Ventilators In the Process of Indoor Fire-fighting

2009 Co-op and Condo Expo

6 PIPING ARRANGEMENTS

Fits into compatible switch frames from manufacturers such as Busch-Jaeger, Gira, Berker and Merten.

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Kills bills. How Vaillant technologies reduce home heating bills

Solar Information. Solar Radiant Heating. Innovating Today s Solar Technology for the Future of Tomorrow

Stulz CyberMOD EC Fan Retrofit Kit Switch & Save

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

GILDED Logo. GILDED Images

Hot-Water Circulation

New Zealand Sales Hotline: Sales Fax:

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

Domestic Hot Water Application manual

30% Take lead on your project with an efficient system concept. lower energy.

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Temperature Rises as Products Compete in the Heat. Market. Contact: Tim Page Press Release No: 20. Release date: Immediate Date: 11/11/09

Strong partners in innovative climate technology. Comfort Air Curtains Model CA DK for Daikin VRV-system

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

General knowledge on the Energy labelling. LabelPackA+ Place, Date

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

ELECTRIC WATER HEATERS

The electrical wattage needed by the circulator is:

Multi-Unit Residential Buildings

XTZ SUB AMP1 Subwoofer Amplifier. User manual XTZ AB,

Domestic Hot Water production

DIGITAL HOT WATER SOLUTIONS

Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)

heat interface units A BOILER WITHOUT A FLAME

The. Steam ONE-PIPE STEAM SYSTEMS

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Residential Water Conservation Research Brief On-Demand Hot Water Systems

report prepared for 5 Bedroom Victorian House, Widcombe version BEDROOM VICTORIAN HOUSE, WIDCOMBE

Heat Pump Water Heater Commercial Leaflet 2012

voith.com Systems for smooth operation Tensioning devices and guides

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

Your specialized partner for intelligent building technology

Your home heating since 1888

Transcription:

.. More than twenty years Hungarian experience in one pipe heating system renovation Tamas Szekely - BDM 1 Hydronic Balancing & Control

Obvious Demand of energy saving EPBD Usage of TRV (high capacity for one pipe, presetting for two pipe systems) Comfortable room temperature (Xp: 2K/1K) Hydraulic balancing? 2 Hydronic Balancing & Control

Consequences of bad hydronic balance Noise problems Insufficient capacity Bad comfort Long start up times Waste of energy 3 Hydronic Balancing & Control

Renovation of systems in Hungary Installation of thermostatic radiator valves and thermo heads Installation of riser controller manual automatic 4 Hydronic Balancing & Control

Few statistical data 643k district heated flats in 86 cities 52% are renovated (heating) 60% one pipe system 80% from top to down piping, rest P Few DHCs support the renovation only Additional ~ 400k flats with big central boiler station (>40 flat) No information about renovation % Few, small size Housing Associations >95% housing communities Potential still 1M TRV, 130T BV Usage of HCA is very popular Covers 65% of installation market 5 Hydronic Balancing & Control

Flats Number of district heated flats and renovation + 240.000 in Budapest only 60% are renovated 35000 30000 25000 20000 15000 10000 5000 0 Flats Renovated flats Cities 6 Hydronic Balancing & Control

Type of one pipe heating systems Without by-pass with by-pass on top with by-pass+valve/trv Typically 5, 10 and 16 floors buildings Distribution on top P type Combination of them Special applications handrail partition wall 7 Hydronic Balancing & Control

Directions of renovation Included with wall insulation and window exchange ~60% Conventional solution Install by-pass (if needed) + TRV, BV Often equipped with HCA Install new two pipe, to be replaced 1 pipe system (<3%) Too expensive, never pays back Separation from DH system (more often forbidden) Removing of boiler station and individual boiler installation per flat Renovation goes house to house Convince All housing comunities one by one 8 Hydronic Balancing & Control

Features of renovation projects Tender specifications are wrong does not contain DHW renovation In 15-20% only Budapest DH company made compulsory MB usage for 1 pipe It changed to AB 2 years ago Typically low quality solution Cheap products, manual balancing Danfoss put more focus on renovation in 2011-2012 Not possible to replace RA-G due to high capacity (Danfoss replaced others) Automatic balancing more popular Partners are grateful for Danfoss experience 9 Hydronic Balancing & Control

Subordinated risers Improving saving potential

Do we concentrate enough on those risers? TRV in important rooms No TRVs in subordinated rooms Balancing in the bottom of important risers Manual balancing Automatic balancing Balancing of subordinated risers 11 Hydronic Balancing & Control

Typical problems TRV generally not used in staircases Often used candle riser for bathrooms Radiators are oversized mostly In both, one-pipe and two-pipe systems Manual balancing is used if at all Overflow and energy loss on subordinated risers during partial load 12 Hydronic Balancing & Control

Recommendation Automatic balancing...+ self-acting control... + electronic control 13 Hydronic Balancing & Control

Project execution Where from the money and how we can install

Financing Panel block flat rehabilitation program by government from 1995 Covers up to 50% of total value Due to limited source, slows down the process (52% of total till today) In 2010 the government subsidy cancelled and renovation stopped Financing restarted by municipalities in these years Normally covers up to 30% of total value but mostly for heating only Kecskemet 90%, the city almost ready Renovation is collapsing nowadays Lack of money (70% is too much for houses) Owner finance should started now 15 Hydronic Balancing & Control

Installation HCA companies are the biggest players (Techem 60-70% of total) 3-4 additional player on the market Operating Structures are specifying and handling the projects Without knowledge and experience Low quality design Danfoss preferred as problem solver Low manpower in plumbing sector (today) Few special solution for unique systems Yearly market ~1.000 flat today 16 Hydronic Balancing & Control

Collection of renovated buildings THT Condominium Households Yearly issue - till 2015 The top 100 renovation Different level of renovations Complete renovation Window exchange + heating renovation Detailed info about executed installation Saving result compensated by degree day method Includes useful information (advertisement) from suppliers 17 Hydronic Balancing & Control

Content of project sheet Location Picture about the building Labelling - rank development Size of investment/building Saving chart Source of money Installer name Technical parameters windows exchange heating renovation TRV Balancing Radiator exchange HCA Total saving 18 Hydronic Balancing & Control

Full renovation (included insulation) Location Picture about the building Labelling rank development Size of investment Saving chart Source of money Installer Technical parameters windows exchange heating renovation TRV Balancing Radiator exchange HCA Total saving 19 Hydronic Balancing & Control

...one more example Location Picture about the building Labelling rank development Size of investment Saving chart Source of money Installer Technical parameters windows exchange heating renovation TRV Balancing Radiator exchange HCA Total saving 20 Hydronic Balancing & Control

Learning points Diameter diminution in front of radiator Noise Aluminum radiator as an amplifier Pipe fixation among floors Air bubbles de-aeration Filling method, heat up the water to reduce the solute oxygen from water Balancing valve Capacity of TRVs (bigger is better) Insulation of building and the flow temperature 16 floor buildings are critical, precise calculation is needed Stretching risers 21 Hydronic Balancing & Control

Learning point by-pass installation The critical radiator is the first one in the loop Wit by-pass installation we have lower emission in fist radiator a < 1; Let s presume 20% Result around 10-15% reduction We need to compensate it Increasing flow rate bigger pump Higher flow temperature hard to solve Most of the case the radiators are oversized, so not need special action... but must to check and precisely calculate! 22 Hydronic Balancing & Control

Case study from HU AB-QM saving potential

Case study (HU) Address: Nepfürdő u. 19 Number of floors: 10 Number of staircases: 6 Number of flats: 260 Heated space: 40.892 m3 Number of radiators: 1040 Number of risers: 128 AB-QM installation only DN 15-25 (26, 68, 34 pcs.) 25 Hydronic Balancing & Control

Case study (HU) 26 Hydronic Balancing & Control

Case study from PL AB-QM + CCR3 saving potential

Why shall we use CCR3 In partial load, we need significantly lower flow demand Lowering the return temperature with CCR3 despite water by-passing Penalty for too high return temperature (e.g. in Germany) heat loss on return pipeline, efficiency drop on co/trigeneration power station Saving on pumping (create variable flow in one pipe system) 28 Hydronic Balancing & Control

System design 29 Hydronic Balancing & Control

Components of electronic return temp. limit. CCR3 control electronic TWA-Z thermal actuator to AB-QM Temperature sensors 30 Hydronic Balancing & Control

Energy saving in whole hating season 31 Hydronic Balancing & Control

Test result of electronic control Long (period) test Setting of CCR3 Two parallel risers Decreasing outdoor (blue line), the flow temp (red line) increasing The return temperature (yellow and green) follow the trend of flow temperature 32 Hydronic Balancing & Control

Energy saving The energy saving calculation based on 24 days measurement The electronic control was established in two staircases Heating energy saving is 24% Pumping energy saving is 69% 33 Hydronic Balancing & Control

Energy saving Conclusion: Recommended investment, with acceptable expenditure we can realise significant energy and money saving in whole season long. The pay back time is favourable! To be taken into consideration we need to use hydronic balancing in any case the payback time become shorter!) 34 Hydronic Balancing & Control