Dual-Diode Dosimeter Patient Dose Monitor

Similar documents
Nuclear Associates

Nuclear Associates

Victoreen & 660-8

Victoreen Primalert 35 Area Radiation Monitor

MapCHECK 3. The New Benchmark for 2D IMRT QA. Your Most Valuable QA and Dosimetry Tools

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Enteral Pump Instructions for Use To Assemble When the low

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

TRACERCO Radiation Monitor

MicrOTDR. Optical Fault Locator. User Manual

RAM GENE / RAM GENE-1

HIn3550 Magnetic Field Monitor User's Manual

TRACERCO Radiation Monitor. Instruction and Maintenance Manual for Model No. T202

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

Instructions. Consumer Info-Line

Victoreen. Operator Manual. Current Mode Beta Scintillation Detector, Model

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Precision Infrared Thermometer. Users Manual

Contamination Meter Users Manual

Digital Temperature Calibrator - Thermometer MODEL 840A, 845, 850, 855

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

62 MAX/62 MAX + Infrared Thermometer

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

ACQUITY UPLC HT Column Heater Instructions

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

Reference Manual. MultiVision Gas Detector

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

(Place Logo from Lab here)

EST User Manual. (Please read this manual carefully before using)

Area Monitor/Frisker Count Rate Meter Victoreen

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Model ST-128M Moisture Detector

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

Dosimeters/Survey meters

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

User Manual. Non-contact Infrared Thermometer.

PL400 Patient Lift Scale Indicator Owner s Manual

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Using the GammaRAE II Personal Radiation Detector

Kata products Kata DGM-1500 Turva

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Portable Survey Instruments NISP-RP-01

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

SENSIT HXG-2d Combustible Gas Detector

Operate the Mutli-Gas Monitor PID

Installation, Operation, and Maintenance Instruction Manual

TRACERCO T402 and T402HR USER MANUAL

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

CLETEF-786. Infrared Thermometer Instruction Manual

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Identify the following features and specifications for the ESP1

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

USER MANUAL MINITRACER PORTABLE SNIFFER

MiniRAE 3000 ppbrae Basic Operation Pocket Reference

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

LUDLUM MODEL 19A. Micro R Meter. May 2017 Serial No and Succeeding Serial Numbers

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Manual Hygrometer PCE-555

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

Four channel video link For low cost video transmission

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

62 MAX/62 MAX + Infrared Thermometer

Reference Manual. MultiPro Gas Detector

Reference Manual MultiPro Gas Detector

MINI-RADIAC INTRODUCTION

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Kinsa Smart Ear ThermometerTM Instructions For Use

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

COA-2010-F Electronic CO 2

Product waste disposal - Protection of the environment:

EVac II Programmable Digital Vacuum Gauge

Visit us at testo 835 Infrared and contact thermometer

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Druck DPI 705/DPI 705 IS Series

Using the MiniRAE 2000 & ppbrae PID

Reference Manual Oxy Plus Single Sensor Gas Detector

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

OSART Good Practices RADIATION PROTECTION Radiation protection instrumentation, protective clothing and facilities

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Digital Salt / TDS Meter. 390a. The Value Leader TM

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

62 MAX/62 MAX + Infrared Thermometer

Spy Jeepmeter ope rati ng instructions

RK CO 2 Transmitter Operator s Manual

MT4 MAX/MT4 MAX + Infrared Thermometer

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

Transcription:

37-720 Dual-Diode Dosimeter Patient Dose Monitor User Manual January 2008 Manual No. 160111 Rev. 6 2003, 2005, 2008 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies

Fluke Biomedical 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com

Table of Contents Section 1: General Information... 1-1 1.1 Introduction... 1-1 1.2 Specifications... 1-2 1.3 Accessories... 1-3 Section 2: Operation... 2-1 2.1 Battery Check... 2-1 2.2 Zeroing the Instrument... 2-1 2.3 Calibration... 2-1 2.4 Making a Measurement... 2-2 Section 3: Maintenance... 3-1 3.1 Battery Replacement... 3-1 3.2 Diode Cleaning Instructions... 3-1 i

(Blank page)

General Information Introduction 1 Section 1 General Information 1.1 Introduction System Description The Dual-Diode Dosimeter Patient Dose Monitor combines a compact, battery operated, electrometer with a silicon diode detector. The detector can be placed anywhere external to the patient for dose verification and is easily held in position by taping to the skin. The diode can be taped directly to the patient s skin to obtain data for TLD readout values, eliminating TLD measurements. Irregular field dosimetry is easily performed with this system. No temperature pressure corrections need be applied to values obtained during the measurement process. The system allows accurate and reproducible dose and dose rate data to be obtained without the necessity of temperature equilibration or warm-up time. Measurements can be read directly on the 3½-digit liquid crystal display (LCD) readout, eliminating complex calculations. The electrometer has two detector inputs on the rear panel labeled DET A and DET B. Each input has a range of 0 through 1999 cgy or cgy/min. A front panel switch enables the selection of the detector input being utilized. Each detector has a clearly marked, screwdriver adjustable set of calibration and zero controls mounted conveniently on the front panel. A quick response reset button, also on the front panel, sets the system up for the next reading. Patient Dose Monitor Model 37-720 is designed specifically for use with the silicon diode detectors (positive output) recommended by Fluke Biomedical, Radiation Management Services (see Section 1.3). The electrometer must be calibrated for each individual detector and radiation source. A special feature inherent in the 37-720 is the ability to switch between DET A and DET B, using the front panel switch, so that two detectors can be utilized for monitoring at the same time. This feature is applicable when the measurement is being taken in the dose or rate mode. Measurements can be taken in DOSE or RATE depending on the setting of the function switch. If it is desired to switch from one mode to another, the RESET switch can be pressed to zero the electrometer. 1-1

37-720 User Manual 1.2 Specifications Range cgy: 0 to 2000 cgy/min: 0 to 2000 Sensitivity.25 nc/cgy 2 nc/cgy Calibration Adjustments Front panel screwdriver adjustments: CAL A and CAL B used for calibration of detector A and detector B. ZERO A and ZERO B used to set up zero for detector A and detector B. CAL A and CAL B used for calibration of detector A and detector B. ZERO A and ZERO B used to set up zero for detector A and detector B. Front Panel Controls Rear Panel Controls Display Accuracy Rads Holding Drift Batteries Required Battery Check Battery Life Case Power Switch: ON/OFF Function Switch: DOSE or RATE modes of operation Detector Switch: DET A or DET B selects detector input. Reset Switch: Resets & zeros monitor for dose measurements. Two BNC connectors for DET A input and DET B input. A 3 ½-digit liquid crystal display provides direct reading of the measurement + 5 % of full scale, current and charge Better than 1 % / minute One 9 V alkaline cell (Duracell MN1604 or equivalent) LO BAT appears on display when battery voltage drops below approximately 6 V Approximately 150 hours Ivory, high impact plastic Dimensions 2.5 in x 6.25 in x 8 in (H x W x D) (6.4 cm x 15.9 cm x 20.4 cm) Weight Operating Conditions 1.5 lbs (0.68 kg) 10 C to 45 C (50 F to 104 F) Maximum 90% Relative Humidity non-condensing 1-2

General Information Specifications 1 Routine Cleaning CAUTION Do not immerse the Model 37-720 Dual-Diode Dosimeter Patient Dose Monitor. The unit is not waterproof. Liquid could damage the circuits. The unit should be kept clean and free of dirt and contamination. The unit may be cleaned by wiping with a damp cloth using any commercially available cleaning or decontaminating agent. NOTE Refer to the applicable diode manual for specific response characteristics relative to diode performance. 1.3 Accessories Part Number Description 30-492 Diode Detector Holder 88-490 Diode Extension Cable 30 88-490-1000 Diode Extension Cable 10 VeriDose Diodes Model Range Polarity/Color Buildup Buildup Type (g/cm2) Electrometer 30-471 1-4 MV Positive/Blue Cu 0.732 37-720 30-472 5-11 MV Positive/Yellow Cu 1.359 37-720 30-473 12-17 MV Positive/Red W 2.606 37-720 30-474 18-25 MV Positive/Green W 3.574 37-720 30-475 5-25 MeV Positive/Grey 0.284 37-720 1-3

(Blank page)

Operation Battery Check 2 Section 2 Operation 2.1 Battery Check Model 37-720 Dual-Diode Dosimeter Patient Dose Monitor is shipped with the battery installed. Turn power on by placing the ON/OFF switch to the ON position, then look at the upper left hand corner of the display. If the battery is low, a LO BAT message will appear on the display. NOTE If a probe has been connected, remove it until the zero adjustments are complete. 2.2 Zeroing the Instrument Place the function switch in the DOSE position and the detector switch in the DET A position. Press the RESET button. In approximately five to seven seconds, a zero reading will appear on the display. If the zero reading does not appear, adjust the ZERO A control using a small screwdriver until a zero reading is obtained. The RESET switch should be held in while zeroing the instrument. Once the RESET switch is released, the display will remain at zero and drift less than 1% of full scale in one minute. Repeat this process for DET B, if necessary. Place the function switch in the RATE position and the detector in the DET A position. The display will show a value, but it should show a zero value in approximately five to seven seconds. Repeat this process for DET B. The monitor will zero automatically when it is used in the RATE position, so it is not necessary to use the RESET switch. Connect the probe or probes to the rear panel connectors. Before taking readings, each probe should be calibrated as discussed in the following paragraphs. 2.3 Calibration Calibration is performed by positioning the diode at a point in a phantom where the dose is accurately known. The screwdriver adjustment (CAL A or CAL B), located on the front panel, can now be performed. Adjust CAL A or CAL B (depending on the detector being calibrated), until the indicated dose or dose rate appears on the display. 2-1

37-720 User Manual NOTE If two detectors are connected, alternate readings can be taken by switching between DET A and DET B. Both detectors should be calibrated concurrently. The highest degree of calibration can be attained by calibrating at a dose or dose rate near ½ scale (1000 cgy or 1000 cgy/min). This is due to display resolution. After the battery check, instrument zeroing, and calibration have been performed, measurements can be taken. 2.4 Making a Measurement Rate: cgy/min 1. Zero the instrument if not previously zeroed. Refer to "Zeroing the Instrument", at the beginning of Section 2.2. 2. Connect the appropriate probe/probes to the DET A, DET B inputs. 3. Select the RATE mode on the front panel. 4. Initiate a radiation exposure. 5. During the exposure, view the reading on the display. Dose Mode: cgy 1. Zero the instrument if not previously zeroed. Refer to "Zeroing the Instrument", at the beginning of Section 2.2. 2. Connect the appropriate probe/probes to the DET A, DET B inputs. 3. Select the DOSE mode on the front panel. 4. Initiate a radiation exposure. 5. Upon completion of the exposure, view the results on the front panel display. 6. Alternate between DET A and DET B to view both channels. 2-2

Maintenance Battery Replacement 3 Section 3 Maintenance 3.1 Battery Replacement If the LO BAT message appears on the display, the battery should be replaced. Turn the power off. Open the battery compartment (located on the rear panel). Pry on the rippled side to open the door and gain access to the battery. Remove the old battery and replace it with a new one. When disconnecting or reconnecting a battery, take care not to damage the connector as it is attached to short leads. 3.2 Diode Cleaning Instructions The diodes may be cleaned with an alcohol swab or any disinfectant, which is commonly used in hygienic care. (Reference only, not to scale) Figure 3-1. Component Layout Diagram (160010) 3-1

(Blank page)

(Blank page)

Fluke Biomedical 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com