Environment Protection Engineering

Similar documents
Energy Performance of Eco-friendly R152a and R600a Refrigerants as Alternative to R134a in Vapour Compression Refrigeration System

Performance Assessment of Three Eco-Friendly Hydro-Fluorocarbon and Hydrocarbon Refrigerant Mixtures as R22 Alternatives in Refrigeration Systems

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

Thermodynamic analysis of the performance of a vapour compression refrigeration system, working with R290 and R600a mixtures

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Scientific Journal of Maritime Research 31 (2017) Faculty of Maritime Studies Rijeka, 2017

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

International Journal of Advance Engineering and Research Development

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

ANNALS of Faculty Engineering Hunedoara

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

A Comparison Between Refrigerants Used In Air Conditioning

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Chapter 10. Refrigeration and Heat Pump Systems

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Study of R161 Refrigerant for Residential Airconditioning

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

CHAPTER 1 INTRODUCTION

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

A RECENT REVIEW OF REFRIGERANT R-1234YF AND R-1234ZE (E)

Oyelami S., Bolaji B. O.

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Thermodynamics I. Refrigeration and Heat Pump Cycles

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

JJMIE Jordan Journal of Mechanical and Industrial Engineering

CHAPTER 1 INTRODUCTION

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Experimental investigation on the performance of air conditioner using R32 Refrigerant

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

η second law = Second law efficiency

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Energy Performance Assessment of R32/R125/R600a Mixtures as Possible Alternatives to R22 in Compression Refrigeration Systems

THE USE OF HYDROCARBONS PROPANE AND ISOBUTANE IN REFRIGERATION SYSTEMS

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Low Global Warming Refrigerants For Commercial Refrigeration Systems

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Chapter 2. Alternatives to HCFCs and their Characteristics

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Experimental performance evaluation of vapour compression refrigeration system without nano particles

Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Design of LPG Refrigeration System

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

HFCs or the Old Refrigerants - what is the best Choice?

Theoretical analysis of low GWP mixture R600a/ R1234ze as a possible alternative to R600a in domestic refrigerators

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

Performance analysis of vapour compression refrigeration systems using eighteen ecofriendly and other CFC refrigerants

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Thermodynamics II Chapter 5 Refrigeration

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Low GWP Refrigerants for Air Conditioning Applications

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

ISSN: [Sachuthananthan * et al., 5(10): October, 2016] Impact Factor: 4.116

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

ADVANCES in NATURAL and APPLIED SCIENCES

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Volume 1, Issue 2 (2013) ISSN International Journal of Advance Research and Innovation

Chapter 9. Refrigeration and Liquefaction

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Transcription:

Environment Protection Engineering Vol. 38 212 No. 4 DOI: 1.5277/EPE1244 BUKOLA OLALEKAN BOLAJI*, ZHONGJIE HUAN* COMPUTATIONAL ANALYSIS OF THE PERFORMANCE OF OZONE-FRIENDLY ALTERNATIVE REFRIGERANTS IN VAPOUR COMPRESSION AIR-CONDITIONING SYSTEMS Performance of two ozone-friendly refrigerants ( and ) was investigated theoretically using computational thermodynamic analysis. The results obtained showed that the performance of was very close to that of in all the operating conditions. Both and performed better than in terms of their COP and refrigerating effect. Compared with, the average COP and refrigerating effect of are lower by 13.78 and 33.96%, respectively. Generally, refrigerant has approximately the same performance with, therefore, it is considered as a good drop-in substitute for in vapour compression air-conditioning system. 1. INTRODUCTION Theoretically, the coefficient of performance (COP) of an ideal Carnot vapour compression cycle is independent of the refrigerant. However, the irreversibilities inherent in the ideal cycle cause the COP and other performance parameters of practical cycle to depend on the refrigerant [1]. Therefore, refrigerant represents one of the important ingredients of any vapour compression refrigeration system. It immensely influences design, operation and performance of the system [2]. The linkage of the CFC refrigerants to the destruction of the ozone layer, which has been established recently, is attributable to their exceptional stability because of which they can survive in the atmosphere for decades and ultimately diffusing to the rarefied heights where the stratospheric ozone layer resides. The inventors of these refrigerants could not have visualized the ravaging effects of the refrigerants on the ozone layer. They intentionally pursued refrigerants with the exceptional stability that was *Department of Mechanical Engineering, Faculty of Engineering and Built Environment, Tshwane University of Technology, Pretoria, South Africa; corresponding author B.O. Bolajl, e-mail: BolajiBO@tut.ac.za

42 B.O. BOLAJI, Z. HUAN imposed as one of the necessary requirements of the ideal refrigerant they were called upon to invent [3]. In the past, refrigerants have been selected on the basis of suitable qualifying properties such as non-flammability, non-toxicity, stability and good materials compatibility. Also considered are a qualitative assessment of transport and thermodynamic properties such as the desirability of a low viscosity, high latent heat, and operation away from the critical point. The performance of refrigerants which satisfied these criteria were then calculated for various applications and compared with each other [4]. Chlorofluorocarbon (CFC) and hydro-chlorofluorocarbon (HCFC) refrigerants fulfilled all the primary requirements and heralded an unprecedented revolution in the refrigeration and air-conditioning industry. Today, the litany of the requirements imposed on an ideal refrigerant has increased. The additional primary requirements now include zero ozone depletion potential (ODP) and low global warming potential (GWP) [5]. The continuous depletion of the ozone layer, which shields the earth s surface from the biologically damaging ultraviolet sunlight called UV-B radiation, has resulted in a series of international treaties demanding a gradual phase out of CFC and HCFC refrigerants. The CFCs have been phased out in developed countries since 1996, and 21 in developing countries [6]. Initial alternative to CFCs included some hydro-chlorofluorocarbons (HCFCs), but they will also be phased out internationally by year 22 and 23 in developed and developing nations, respectively [7, 8]. Since came into common use as a refrigerant in 1936, it has been applied in systems ranging from smallest window air-conditioners to the largest chillers and heat pumps. Individual equipment using this versatile refrigerant ranges from 2 kw to 33 MW in cooling capacity. No other refrigerant has achieved such a wide range of applications [9]. However, is one of a class of chemicals, HCFCs, being phased out due to the environmental hazard of ozone depletion [1, 11]. Ozone friendly alternative refrigerants in air-conditioners and heat pumps can be grouped into three categories; the first category is hydro-fluorocarbons (HFCs) that are used in conventional vapour compression cycles such as R134a, R413A,, R47C. The second category is natural fluids, which includes propane (R29) and ammonia (R717). Although these refrigerants have zero ozone depletion potential (ODP) and minimum global warming impact due to direct emissions but there are safety and environmental factors associated with them that would limit their widespread use as refrigerants. The third category is alternative cycles that include absorption systems, and use of transcritical fluid CO 2 (R744) and air cycles. In general, these alternative cycles do not currently offer the same energy efficiency as the vapour compression cycle using HFC refrigerants and so, they increase indirect global warming emissions via increased fossil fuel usage through increased electrical energy consumption [12, 13]. Blends of the HFC refrigerants, in the first category of alternative refrigerants, have been considered the favourite candidates for alternatives. HFCs are synthetic

Ozone-friendly alternative refrigerants 43 fluids entirely harmless to the ozone layer since they do not contain chlorine and hence have zero ODP. These fluids are the most used substitutes for CFCs and HCFCs [14]. The research on refrigerant replacement for has been one of hot topics in the refrigeration and air-conditioning industry. Many refrigerants were assessed through the Alternative Refrigerant Evaluation Program (AREP) as potential replacements for. The most promising alternative refrigerants that emerged were, R47C, R134a, and R29. This list has since been revised to include, R44A and R57 [6, 15]. Environmental impacts of the investigated refrigerants [1] Table 1 Refrigerant Ozone depletion Global warming potential (ODP) potential (GWP) (1 year horizon).55 17 1725 1985 Table 1 shows the environmental impacts of the investigated refrigerants. It is clearly shown in the table that both and have zero ODP, therefore, they do not contribute to the depletion of ozone layer. has the highest GWP, while the GWP of is very close to that of [1]. Beside the environmental factors, the successful replacement and use of these alternative refrigerants required investigations of their suitability in the system by evaluating and comparing their performance with performance of existing refrigerant in the system [16]. Therefore, the paper presents the results of computational analysis of thermodynamic properties of and two of its ozone-friendly alternatives HFC mixtures ( and ) in a standard air-conditioning system. is a non-azeotropic mixture composed of R125, R134a and RE17 (dimethylether) (77, 19 and 4 wt. %, respectively), and is a near azeotropic mixture composed of R32 and R125 (6 and 4 wt. %, respectively). The performance parameters of the system working with these alternative refrigerants were evaluated and compared with those of. 2. MATERIALS AND METHODS Vapour compression refrigeration system. Figure 1 shows vapour compression refrigeration cycle on the P h diagram. The refrigeration system is made up of four major components: condenser, evaporator, compressor and expansion device. In the evaporator, the liquid refrigerant vaporizes by absorbing latent heat from the material being cooled, and the resulting low pressure vapour refrigerant then passes from the evaporator to the compressor. Compressor is the heart of the refrigeration system. It pumps and circulates refrigerant through the system, and supplies the necessary force to

44 B.O. BOLAJI, Z. HUAN keep the system operating. It raises the refrigerant pressure and hence the temperature, to enable heat rejection at a higher temperature in the condenser. Condenser is a device used for removing heat from the refrigeration system to a medium which has lower temperature than the refrigerant in the condenser. The high pressure liquid refrigerant from the condenser passes into the evaporator through an expansion device or a restrictor that reduces the pressure of the refrigerant to low pressure existing in the evaporator. Expansion device regulates or controls the flow of liquid refrigerant to the evaporator. P P c 3 Condensation 2' 2 Expansion P e 4 Evaporation 1 Compression h Fig. 1. Vapour compression refrigeration cycle on the P h diagram Considering the cycle on the P h diagram in Fig. 1, the following assumptions are made: 1. Evaporation under constant pressure (P e ) and at constant temperature (T e ) in the evaporator from point 4 to point 1. The heat absorbed by the refrigerant in the evaporator or refrigerating effect (Q evap, kj/kg) is given as: Q evap = h 1 h 4 (1) where h 1 is the specific enthalpy of refrigerant at the outlet of evaporator (kj/kg), h 4 the specific enthalpy of refrigerant at the inlet of evaporator (kj/kg). 2. An isentropic compression process in the compressor, from point 1 to point 2. The compressor work input (W c, kj/kg) is W c = h 2 h 1 (2) where h 2 is the specific enthalpy of the refrigerant at the outlet of compressor (kj/kg). 3. De-superheating under constant pressure (P c ) from the compressor discharge temperature (T 2 ) at point 2 to the condenser temperature (T c ) at point 2, followed by condensation at both constant temperature (T c ) and constant pressure (P c ) from point 2 to point 3. The heat rejected in the condenser (Q c, kj/kg) is Q c = h 2 h 3 (3) where h 3 is the specific enthalpy of refrigerant at the outlet of the condenser (kj/kg). 4. Expansion at constant enthalpy (isenthalpy) in the throttling valve from point 3 to point 4. Therefore,

Ozone-friendly alternative refrigerants 45 h 3 = h 4 (4) The coefficient of performance (COP) is the refrigerating effect produced per unit of work required; therefore, COP is obtained as the ratio of Eq. (1) to Eq. (2): COP Q evap ref = (5) Wcomp Computational analysis. The most fundamental of a working fluid thermal properties that are needed for the prediction of a refrigerant system s performance are the pressure volume temperature (PvT) in an equilibrium state. Other properties, such as enthalpy and entropy as well as the Helmholtz and Gibbs functions, may be derived from a PvT correlation utilizing specific heat. There exists a myriad of equations of state, which have been classified into families. These equations have been used to develop the most widely used refrigerant database software known as REFPROP [17, 18]. It was developed and is maintained by the National Institute of Standards and Technology and is currently in its ninth edition. It uses several equations of state to correlate 33 single component refrigerants and 29 predefined mixtures, along with the ability to construct virtually any desired mixture of up to five components [19]. This software was used in this work to compute the properties of investigated refrigerants. 3. RESULTS AND DISCUSSION The refrigerating effects of and its two potential alternative refrigerants at varying evaporator temperature for condensing temperatures of 3, 4 and 5 C are shown in Figs. 2a c, respectively. As shown in these figures, refrigerating effect increases as the evaporator temperature increases for all the investigating refrigerants. This is due to the increase in latent heat value of the refrigerant. A very high latent heat value is desirable since the mass flow rate per unit of capacity is lower. When the latent value is high, the efficiency and capacity of the compressor are greatly increased. This decreases the power consumption and also reduces the compressor displacement requirements that permit the use of smaller and more compact equipment. The curves of, as clearly shown in Fig. 2, are very close to those of with advantage of higher values, while the curves for are far below that of, which indicate very low refrigerating effect. The refrigerating effect for varying condensing temperature is shown in Fig. 3. Refrigerating effect for the three refrigerants reduces as the condensing temperature increases. This is due to an increase in the enthalpy of refrigerant at inlet to the evaporator as a result of the increase in the condensing temperature, which reduces the refrigerating effect. The highest refrigerating effect was obtained using with average value of 3.44% higher than that of, while has an average value of 33.96% lower compared with that of.

46 B.O. BOLAJI, Z. HUAN 2 a) 2 b) Refrigerating effect (kj/kg) 16 12 8 4 Refrigerating effect (kj/kg) 16 12 8 4-3 -2-1 1-3 -2-1 1 16 c) Refrigerating effect (kj/kg) 12 8 4-3 -2-1 1 Fig. 2. Refrigerating effect upon evaporator temperature at condensing temperature of: a) 3 C, b) 4 C, c) 5 C 2 Refrigerating effect (kj/kg) 16 12 8 4 3 4 5 Condensing temperature ( o C) Fig. 3. Refrigerating effect upon varying condensing temperature

Ozone-friendly alternative refrigerants 47 Compressor work input (kj/kg) 6 5 4 3 2 1 a) Compressor work input (kj/kg) 7 6 5 4 3 2 1 b) -3-2 -1 1-3 -2-1 1 Compressor work input (kj/kg) 8 6 4 2 c) Fig. 4. Dependences of compressor work input on evaporator temperature at condensing temperature of: a) 3 C, b) 4 C, c) 5-3 -2-1 1 Compressor work input (kj/kg) 5 4 3 Fig. 5. Dependences of compressor work input on condensing temperature 2 3 35 4 45 5 Condensing temperature ( o C)

48 B.O. BOLAJI, Z. HUAN The compressor work input for and its two potential alternatives at varying evaporator temperature for condensing temperature of 3, 4 and 5 C are shown in Figs. 4a c, respectively. These figures clearly revealed that compressor work input increases with increase in the evaporator temperature. Similar trend and variations of compressor work input were obtained for both and for all cases of condensing temperatures studied. exhibited lower compressor work input than both and. Figure 5 shows the variation of compressor work input as a function of condensing temperature. As shown in the figure, the average compressor work input of is very close to that of with average value of 5.4% higher than that of, while has an average value of 21.8% lower than that of. Discharge temperature ( o C) 8 6 4 2 a) Discharge temperature ( o C) 1 8 6 4 2 b) -3-2 -1 1-3 -2-1 1 Discharge temperature ( o C) 12 1 8 6 4 c) Condensing temperature = 5 o C 2-3 -2-1 1 Fig. 6. Dependences of discharge temperature with evaporator temperature at condensing temperature of: a) 3 C, b) 4 C, c) 5 C Figures 6a c show the dependence of the discharge temperature for the three investigated refrigerants on the evaporator temperature for the condensing temperatures

Ozone-friendly alternative refrigerants 49 of 3, 4 and 5 C, respectively. The alternative refrigerants ( and ) exhibited lower values of the discharge temperature than, though the curves for are almost the same with those of, which depicts the same performance in the system. Discharge temperature ( o C) 1 8 6 4 2 Fig. 7. Dependences of discharge temperature on condensing temperature 3 4 5 Condensing temperature ( o C) High discharge temperature is detrimental to the performance of the system, therefore, low discharge temperature is required, which means that there will be less strain on the compressor and hence a longer compressor life. The lowest value of discharge temperature, which is suitable for the refrigeration system, was obtained using. Figure 7 shows the dependences of the discharge temperature on the condensing temperature. As shown in the figure, discharge temperature increases upon increasing condensing temperature, which is expected due to the direct relationship between the two temperatures. The average discharge temperature obtained for and were 2.46% and 31.26% lower than that of, respectively. The coefficient of performance (COP) for and its two potential alternatives at varying evaporator temperature for condensing temperature of 3, 4 and 5 C are shown in Figs. 8a c, respectively. Similar trends were observed in the three figures, for all the refrigerants considered, COP increases with increase in evaporator temperature. The COPs of the three refrigerants are very close. Also, variation of the COP with condensing temperature is presented in Fig. 9 for the three investigated refrigerants. It is clearly shown in this figure that when condensing temperature increases the COP reduces for both and its alternative refrigerants. COP is inversely proportional to the power input through the compressor, therefore, increase in compressor power due to increase in condensing temperature reduces the COP of the system. has the highest COP closely followed by. Compared with

5 B.O. BOLAJI, Z. HUAN, the average COP of reduced by 3.26%, while that of reduced by 13.78%. 14 a) 1 b) COP 12 1 8 COP 8 6 6 4 4 2 2-3 -2-1 1 Evaporator temperature (oc) -3-2 -1 1 6 c) 4 COP 2-3 -2-1 1 Fig. 8. Dependences of the coefficient of performance (COP) on evaporator temperature at condensing temperature of: a) 3 C, b) 4 C, c) 5 COP 8 6 4 2 3 4 5 Condensing temperature ( o C) Fig. 9. Dependences of the coefficient of performance (COP) on condensing temperature

Ozone-friendly alternative refrigerants 51 4. CONCLUSIONS that is commonly used as working fluid in vapour compression airconditioning systems all over the world is being phased out due to its environmental hazard of ozone depletion. The performances of two ozone friendly, hydro-fluorocarbon (HFC) refrigerant mixtures ( and ) were investigated theoretically using computational thermodynamic analysis and compared with the performance of baseline refrigerant () in a vapour compression air-conditioning system. Based on the results of investigation, the following conclusions have been drawn: Performance of was very close to that of in all the operating conditions and performance characteristics considered. Performance of is slightly better than that of in terms of refrigerating effect and discharge pressure. Compared with, the average refrigerating effect of is higher by 3.44%, while discharge pressure is lower by 2.46%. The COP and refrigerating effect of both and are far better than those of. Compared with, the average COP and refrigerating effect of are lower by 13.78 and 33.96%, respectively. performed better than both and in terms of compressor work input and discharge temperature. It exhibited very low values of these parameters, which are of great interest in refrigeration systems. Compared with, the average compressor work input and discharge temperature of are lower by 21.8 and 31.26%, respectively. The overall evaluation of the performances of the two alternative refrigerants in the standard vapour compression air-conditioning system favoured the use of as a drop-in substitute to in the existing system. It will also perform better as long term substitute for in new systems. The second alternative refrigerant () exhibited wide gap between its performance and that of, the direct substitution of to will require major changes to the existing equipment. Nevertheless, due to its very low compressor work input and discharge temperature it can be considered in new designs in which its performance can be optimized. REFERENCES [1] KIM Y., CHANG, K.S., KIM, H., J. Ind. Eng. Chem., 27, 13, 674. [2] BOLAJI B.O., Investigating the performance of some environment-friendly refrigerants as alternative to R12 in vapour compression refrigeration system, Ph.D. Thesis, Department of Mechanical Engineering, Federal University of Technology, Akure, Nigeria, 28. [3] MCMULLAN J.T., Int. J. Refrig., 22, 25, 89. [4] CAVALLINI A., Int. J. Refrig., 1996, 19, 485. [5] BOLAJI B.O., AKINTUNDE M.A., FALADE T.O., J. Sustain. Energ. Environ., 211, 2 (2), 61. [6] FERNANDEZ-SEARA J., UHIA F.J., DIZ R., DOPAZO J.A., Int. J. Refrig., 21, 33, 148.

52 B.O. BOLAJI, Z. HUAN [7] APREA C., RENNO C., Energ. Convers. Manage., 24, 45, 187. [8] BOLAJI B.O., Energ. Buildings, 211, 43, 3139. [9] CALM J.M., DOMANSKI P.A., ASHRAE Journal, 24, 46, 29. [1] UNEP, Handbook for international treaties for protection of the ozone layers, 6th Ed., United Nation Environment Program, Nairobi, Kenya, 23. [11] BOLAJI B.O., J. Sci. Manage., 211, 1(1), 22. [12] CHEN W., Appl. Therm. Eng., 28, 28, 1. [13] TORRELLA E., CABELLO R., SANCHEZ D., LARUMBE J.A., LLOPIS R., Energ. Buildings, 21, 42, 1561. [14] Bitzer, Refrigerant Report, Bitzer International, 13th Edition, 7165 Sindelfingen, Germany, http://www.bitzer.de Accessed on June 24, 27. [15] DEVOTTA S., PADALKAR A.S., SANE N.K., Appl. Therm. Eng., 25, 25, 2937. [16] BOLAJI B.O., Experimental analysis of reciprocating compressor performance with eco-friendly refrigerants, Proc. IMechE, Part A: J. Power Energ., 21, 224, 781. [17] DIDION D.A., Int. J. Appl. Thermod., 1999, 2, 19. [18] LEMMON E.W., McLinden M.O., HUBER M.L., NIST reference fluids thermodynamic and transport properties REFPROP 7., National Institute of Standards and Technology (NIST), Gaithersburg, MD, USA, 22. [19] KUMAR K.S., RAJAGOPAL K., Energ. Convers. Manage., 27, 48, 353.