EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Similar documents
Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

COMPRESSOR LESS SOLAR REFRIGERATOR

Enhancement of COP in Vapour Compression Refrigeration System

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Performance investigation of Air-conditioning system using ejector as expansion device

A Review Paper on Extracting Waste Heat from the Engine Exhaust and Reutilizing in Car Air Conditioning

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Design & Fabrication of Hybrid Cooler

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Design of LPG Refrigeration System

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Evaluation of Available Heat at the Exhaust of Automotive Engine for Air Conditioning by Vapor Absorption System

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ADVANCES in NATURAL and APPLIED SCIENCES

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Modelling the Performance of a Diffusion Absorption Refrigeration System

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

LECTURE-18 Vapour Absorption Refrigeration System

Design and Fabrication of Water Refrigeration System by Creating Vacuum

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

DESIGN, ANALYSIS AND FABRICATION OF THERMOELECTRIC COOLING AND HEATING SYSTEM FOR WATER DISPENSER

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Modified Air Cooler with Split Cooling Unit

Alternative Cooling Processes 1. Classification of Refrigeration Cycles. Agenda. Hans Jonsson

[Mali*, 4.(12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Waghmare Tushar Ramrao, D.S.Nakate

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

CHAPTER 1 INTRODUCTION

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Sarthak Thakar, 2 R.P.Prajapati 1

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Adsorption refrigeration system using waste heat

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Design and development of vapor absorption refrigeration system for rural dwellers. Adekeye, T. Oyedepo, S.O and Oyebanji, J.A

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Refrigerator and Heat Pump Objectives

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Performance Optimization of the Evaporative Condenser Design

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

International Journal of Informative & Futuristic Research ISSN (Online):

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

(Refer Slide Time: 00:00:40 min)

Optimum Length of a Condenser for Domestic Vapor Compression refrigeration System

PHOTO VOLTAIC COOLING CAN

Design and Development of Water Cooled Condenser for Domestic Refrigerator

CHAPTER 1 INTRODUCTION

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Thermodynamics II Chapter 5 Refrigeration

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

REFRIGERATION AND AIR CONDITIONING

R07. Answer any FIVE Questions All Questions carry equal marks *****

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Assessment of Water Cooled Condenser Refrigeration System

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

Chapter 10. Refrigeration and Heat Pump Systems

Experimental Analysis and Performance Comparison between Evaporative Cooling System and Air Conditioning System

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Refrigeration and Air Conditioning

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

Transcription:

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM AUTHOR 1.ME Student Mech Engg Dept,Godavari COE, Jalgaon,Maharashtra, India 2.Asso. Prof. & Head, Mech Engg Dept,Godavari COE, Jalgaon,Maharashtra, India 3.Asst.. Prof. & ME Co-Ordinator, Mech Engg Dept,Godavari COE, Jalgaon,Maharashtra, India 4.Asst.Prof., Mech Engg Dept,Godavari COE, Jalgaon,Maharashtra, India ABSTRACT With the depleting energy resources recycling of waste energy or recovery of energy from the exhaust of processes or engine is vital method and important of energy conservation. Refrigeration another absolute requirement that needs to be catered, conventionally the vapour compression cycle is the preferred method but it comes with an handicap that the non-conventional energy resources cannot be employed to operate the same. The vapour absorption system using ammonia as refrigerant on the other hand is a method which can be used to harness this recovered process heat or heat carried by the exhaust gases of the engine. The project aims at the design development analysis and performance evaluation of one such scaled system for volume size of 5 liters by utilization of vapour absorption system using ammonia as refrigerant. The paper includes experimental investigation of vapour absorption refrigeration system i.e. to find coefficient of performance of the system. Work includes the heat load calculation and design selection of components of system to suffice the requirements, The critical components of the system have been designed and developed using Unigraphix software and thermal analysis of the components has been done using Ansys Work bench 16.0. Keywords: Waste heat recovery, COP, Vapour absorption system, Ammonia, Thermal Analysis. 1. INTRODUCTION The vapor absorption refrigeration system comprises of all the processes in the vapor compression refrigeration system like compression, condensation, expansion and evaporation. In the vapor absorption system, the refrigerant used is ammonia, water or lithium bromide. The refrigerant gets condensed in the condenser and it gets evaporated in the evaporator. The refrigerant produces cooling effect in the evaporator and releases the heat to the atmosphere via the condenser. The major difference between the two systems is the method of the suction and compression of the refrigerant in the refrigeration cycle. In the vapor compression system, the compressor sucks the refrigerant from evaporator and compresses it to the high pressure. The compressor also enables the flow of the refrigerant through the whole refrigeration cycle. In the vapor absorption cycle, the process of suction and compression are carried out by two different devices called as the absorber and the generator. Thus, the absorber and the generator replace the compressor in the vapor absorption cycle. The absorbent enables the flow of the refrigerant from the absorber to the generator by absorbing it. Another major difference between the vapor compression and vapor absorption cycle is the method in which the energy input is given to the system. In the vapor compression system, the energy input is given in the form of the mechanical work from the electric motor run by the electricity. In the vapor absorption system, the energy input is given in the form of the heat. This heat can be from the excess steam from the process or the hot water. The heat can also be created by other sources like natural gas, kerosene, heater etc. though these sources are used only in the small systems. 2.OBJECTIVE A) To find coefficient of performance of the system. B) To compare the COP before changing the absorber volume and after changing absorber volume 3.ASSUMPTIONS BEFORE CONDUCTING THE EXPERIMENT 8863 www.ijariie.com 314

In this experiment following assumptions is made. a.the vapour leaving the condenser is saturated at condenser temperature. b.the strong solution leaving the absorber is saturated at absorber temperature. c. The weak solution leaving the generator is saturated at generator temperature. d. The strong solution is heated only up to saturation temperature, and no vapour generation takes place in the heat exchanger. e. No pressure changes except through the pump. f. The work input for the pump is negligible relative to the heat input in the generator. Therefore, the pump work is neglected for the purpose of analysis. g. Steady state and steady flow.. 4.EXPLAINATION OF MODEL AND OTHER PARTS Fig.No.1-Three D Model of Vapour Absorption Refrigeration System In this model absorber, generator, solution pump, condenser coil, evaporator coil, cabinet, thermostat,small bulb as load, exhaust fan, cooling purpose condenser fan etc are the parts in this vapour absorption system. First of all with the proper setting of thermostat heater is started then solution 12 V DC pump is started then as soon as pumps starts solution delivers to generator in which solution is heated. Heating of solution takes place due to indirect heating of air by air heater, air is sucked over generator and delivered to atmosphere. Here heated air is used to heat the generator. When heat is applied to strong solution the solution becomes weak and this weak solution send back to absorber vessel.strong solution vapours generated send to condenser for conversion of vapour to liquid ( due to condenser cooling fan temperature decreases hence conversion of vapour to liquid take place ) This high pressure liquid funelling through capillary tube as expansion valve. Here due to Joule Thompson effect pressure decreases, such low pressure low temperature refrigerant passes in the cabinet where evaporator coil is placed it absorbs latent heat of air and thus the air is cooled. From evaporator this refrigerant is passed to absorber, here absorbent is kept water this water absorbs ammonia and thus the solution becomes strong and ready for further cycle. 8863 www.ijariie.com 315

4.1HEATER- Heater is a single phase AC heater with 300 Watt power, provided with helical mild steel fins that improve heating ability of heater through enhanced heat transfer Fig No. 2 Heater The heater arrangement is used as an alternative to the exhaust system that is proposed in the above data. The air heater heats the air which then passes over the heater module using heat pipe mounted on the generator 4.2GENERATOR The generator pipe receive rich water ammonia solution at the bottom via the pump, as the generator body is heated the vapours generated are sent to the condenser section via the top hole where as the lean water ammonia solution is sent back to the absorber via the central hole Fig No. 3 Generator 4.2 EXHAUST FAN Exhaust fan is 230 volt AC 4 inch span axial fan that pulls the hot air over the heat pipe module thereby heating the generator where in the ammonia vapours are produced to be sent to the condenser section. 8863 www.ijariie.com 316

Fig No.4 Exhaust Fan 4.3DIGITAL TEMPERATURE INDICATOR In our set up we have purchased total six digital temperature indicators for taking readings at six point such as temperature before generator, temperature after generator, evaporator temperature, condenser temperature, temperature before absorber, cabinet temperature. The sensor of temperature indicator is attached with teflon tape to evaporator tube, condenser tube and other tubes as shown in the figure below so that error remaining for temperature at six points is constant. Fig No. 5 Digital Temperature Indicator 4.4 VOLTAGE REGULATOR- For experimentation we require voltage regulator for varying the absorber volume flow rate.in the following figure voltage regulator is shown. 8863 www.ijariie.com 317

Fig No.6 VOLTAGE REGULATOR The design of experimentation has given a road map of how the experimentation is planned but implementation of experimental plan and conduction of actual test run requires a systematic detailing of execution. Presentation of those details is the main substance of this paper. Keeping these points in mind this paper is divided into two main parts namely. Experimental procedure Observations. 5.EXPERIMENTAL PROCEDURE FOR BOTH CONSTANT VOLUME AND VARIABLE VOLUME 1.Switch ON the supply to the system and switch ON the main switch to start the heater 2. Check all the temperatures (i.e. 1, 2, 3, 4, 5, and 6) 3. Let the system run for some period (till the temperature in the evaporator tank starts decreasing) 4. Now note down the readings as per the observation table. 5. When cabinet temperature (T6) reaches around 15 C, switch on variator. Adjust the load between 6 to 12 Volts. Ensure that the cabinet temperature does not increase when bulb is switched on. 6. If T6 increases, reduce the power supplied to bulb. 7. Note down 5 6 readings at interval of 5 minutes. 8. Calculate the results as per the calculation procedure. 5.1 Observation Table: For constant volume flow Sr. No T1 T2 T3 T4 T5 T6 V I POWER TIME volt amp 01 31 34.6 18 31 29 21 12 1.2 14.4 10 TABLE NO.1 only one sample reading is given here for calculation purpose. where T1: temperature before generator., T4: condenser temperature T2: temperature after generator T5: temperature before absorber T6: cabinet temperature T3: evaporator temperature 8863 www.ijariie.com 318

5.2CALCULATION & RESULT TABLE COP (Theoretical) = T3 (T2 T5) / T2 (T5 T3) COP = T e (T g -T a ) / T g (T a -T e ) For Reading No.1, COP (Theoretical) = 18 x (34.6-29) / 34.6 (29-18) = 0.2648 COP (actual) = load applied / Heat supplied to generator Load applied = V x I = 14. 4 watt Heat supplied to generator = m* Cp * Δt = 0.014 x 1.009 x 12 *0.3 = 50.85 watt COP act = 14.4 / 50.85 =0.283 6.RESULTS AND DISCUSSION A-For constant volume flow Sr.No Time (min) COP (Th) COP (Act) 01 10 0.264844982 0.283166 02 15 0.285714286 0.298069 03 20 0.328638498 0.314629 04 25 0.340480145 0.336435 05 30 0.362907977 0.369347 Graph of COP (theoretical) Vs. time TABLE NO.2 The theoretical COP of the system is seen to increase with time with maximum COP observed is 0.3629 Graph of COP (actual)vs time 8863 www.ijariie.com 319

The Actual COP of the system is seen to increase with time with maximum COP observed is 0.3694 observed is 0.3694 Comparison Of COP(theoretical) and COP(actual) 7.0EFFECT OF CHANGE IN COP BY CHANGE IN ABSORBER VOLUME In Vapour compression system we can check flow of refrigerant by using rotameter because compressor maintains flow of refrigerant flow through each part such as condenser, expansion valve and evaporator. In condenser state of refrigerant is liquid so refrigerant is always fitted after condenser outlet in vapour compression system. But our system is vapour absorption system so refrigerant flow is checked with the help of instruments as below. Here flow rate is calculated by using stop watch. For one minute proper voltage is set then Liter per minute is find out. For full voltage full flow is observed similarly for haif of the voltage we get haif flow. In such a way we can find out mass flow of refrigerant. 8863 www.ijariie.com 320

Experimental Procedure: 1.Switch ON the supply to the system and switch ON the main switch to start the heater 2. Check all the temperatures (i.e. 1, 2, 3, 4, 5, and 6) 3. Let the system run for some period (till the temperature in the evaporator tank starts decreasing) 4. Now note down the readings as per the observation table. 5. When cabinet temperature (T6) reaches around 15 C, switch on variator. Adjust the load between 6 to 12 Volts. Ensure that the cabinet temperature does not increase when bulb is switched on. 6. If T6 increases, reduce the power supplied to bulb. 7. Note down 5 6 readings at interval of 5 minutes. 8. Calculate the results as per the calculation procedure. Observation Table: For variable volume flow Sr. No Flow rate of pump (kg/min) T1 T2 (o C) T3 (o C) T4 (o C) T5 (o C) T6 (o C) V volt I amp POWER 01 0.66 32 34.6 19.4 31 30 26 12 1.2 14.4 RESULT TABLE Flow rate (kg/min) COP (Th) COP (Act) 0.66 0.243319882 0.255488 0.75 0.262400331 0.269682 0.86 0.293254262 0.287965 1.0 0.340480145 0.329902 1.09 0.352071897 0.357683 Here calculation for variable volume flow COP is calculated as in previous process. Graph of COP (Theoretical) Vs Flow rate (kg/min) 8863 www.ijariie.com 321

The theoretical COP increases with the increase in the flow rate Graph of COP (actual) Vs Flow rate (kg/min) The actual COP increases with the increase in the flow rate Comparison Of COP(theoretical) and COP(actual) The comparison of COP (theoretical) and COP (actual) shows that they are in close agreement indicating that the experiment is validated It is seen that the ideal COP of an absorption system is the sole function of temperatures at which reversible energy transfer takes place. In addition, the expression for COP indicates that there is a fictitious heat engine which works between the generator and absorber temperatures, and a fictitious heat pump works between the evaporator and absorber temperatures.the fictious work output of the heat engine is used to execute the heat pump. 8863 www.ijariie.com 322

8.SCOPE FOR FUTURE WORK This system is designed to reduce the impact of emmission mandating using HCFCs or CFCs as refrigerants to the atmosphere and to preserve perishable goods. However, the system is limited to only electrical power source. Hence, it is recommended that other sorces of powering the machine ( solar, waste heat, etc) should be encouraged for further studies to improve its operation and performance. It is also proposed that high aluminium pipe materials should used as the condenser. This will increase the capacity of the generator thus speeding up the heating process of the system. 1.Closed loop circuit can be developed to link pump flow and refrigerating effect. 2.Multiple generator sets can be used to improve the performance of system 3.System can be made hybrid by use of Peltier modules in circuit that will increase the refrigerating effect. 4.Scope for future work is to include analyzer,rectifier and working fluids hydrogen to convert the strong solution into weak solution and to facilitate the faster rate of evaporation in the evaporator in vapour absorption system. 9.CONCLUSION Keeping in mind the environmental safety point of view, this system is eco-friendly as it involves the use of ammonia (a natural gas ) as a refrigerant and is not responsible for green house effect and Ozone layer depletion. NH3-H2O is the most suitable working fluid due to its high latent heat and excellent heat and mass transfer properties.ammonia absorption technology has great potential to offer economical and innovative solutions to various refrigeration requirements. Absorption machine theory has existed for many years, however just recentely this technology has reached a stage where it is also a commercially viable option. The small capacity application potential of ammonia absorption refrigeration technology makes it a strong candidate for the refrigeration technology of the millennium 1.For good performance the value of L/D should be less than one i.e. the ratio of lift to depression is less than one then the system is said to be performing good.and in my experiment for each reading the value of L/D is less than one.(refer following table for L/D) 2.The Theoretical COP of system increases with the increase in time. 3.The actual COP of system increases with increase in time. 4.The Theoretical COP of system increases with the increase in flow rate. 5.The actual COP of system increases with increase in flow rate. Sr. No T1 T2 T3 T4 T5 T6 Lift =L (T2 T5) D=Depression (Ta-Te) L/D 01 31 34.6 18 31 29 21 5.6 11 0.51 10.REFERENCES JOURNAL PAPERS [1] Harish Shingane,Arpitsingh Kanpuriya, Darshan Ranekar, Sachin Hakdale, Ashish Jumnake and Prof. Saurabh Rathod. Experimental set up of vapour absorption refrigeration system by using NH3-H2O refrigerant with various proportion,,vol-3issue-2,2017 [2] Shekhar D Thakre, Prateek D Malwe,Rupesh L Raut, Amol A Gawali,Cooling of a truck cabin by vapour absorption refrigeration system using engine exhaust, IJRET,eISSN:2319-1163IpISSN:2321-7308 BOOK 1.A course in Refrigeration and Air-Conditioning by Domkundwar, Arora. 8863 www.ijariie.com 323

BIOGRAPHIES A.G.Patil has received the B.E. Mechanical Engineering degree from Institution of Mechanical Engineers ( India ) Mumbai. Now, pursuing M.E.in Mechanical with specialization in Thermal Engineering from Godavari College of Engineering, Jalgaon which is affiliated with North Maharashtra University, Jalgaon in Maharashtra State ( India ) Dr.V.H.Patil has received his Ph.D.degree from Amaravati University in 2018. His title of Ph.D thesis was Failure analysis and performance evaluation of boiler Tube in Thermal power Station. His specialization is in Tribology and Maintenance Engineering. Today he is working as Associate Professor and Head of Mechanical Engineering Department in Godavari College of Engineering, Jalgaon which is affiliated with North Maharashtra University, Jalgaon in Maharashtra State ( India ) Prof.T.A.koli has received the B.E. Mechanical Engineering degree from BAMU Aurangabad and ME Design from NMU Jalgaon. He is ME co-ordinator. He has total 16 years experience Prof.K.M.Mahajan has received the B.E. Mechanical Engineering degree and ME Mechanical Engg degree with specialization in Thermnal Engg from North Maharashtra University, Jalgaon, Maharashtra State (India ). Currentely he is working as Assistant Professor in Godavari College of Engineering Jalgaon, Maharashtra State ( India) 8863 www.ijariie.com 324