A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Similar documents
Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

CHAPTER 1 INTRODUCTION

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

η second law = Second law efficiency

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

CHAPTER 1 INTRODUCTION

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

DEEPAK PALIWAL, S.P.S.RAJPUT

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Design & Fabrication of Hybrid Cooler

International Journal of Advance Engineering and Research Development

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Performance of an Improved Household Refrigerator/Freezer

Study of R161 Refrigerant for Residential Airconditioning

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Department of MCE, Islamic University of Technology 2. Abstract

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

Refrigerants and lubricants

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

Chapter 2. Alternatives to HCFCs and their Characteristics

Oyelami S., Bolaji B. O.

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Sarthak Thakar, 2 R.P.Prajapati 1

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

Enhancement of COP in Vapour Compression Refrigeration System

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Chapter 10. Refrigeration and Heat Pump Systems

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

ADVANCES in NATURAL and APPLIED SCIENCES

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

A Comparison Between Refrigerants Used In Air Conditioning

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Refrigerant Glide and Effect on Performances Declaration

Thermodynamics I. Refrigeration and Heat Pump Cycles

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

REFRIGERATION AND AIR CONDITIONING

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

Experimental investigation on the performance of air conditioner using R32 Refrigerant

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Transcription:

,, IJAET International Journal of Application of Engineering and Technology ISSN: 33 Vol No. A COMPARATIVE STUDY FOR RETROFITTING OF R VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO FRIENDLY REFRIGERANTS R3A, R3A, R3A ABSTRACT Lalit Narayan, Abhishek Arya, Sachin Khare 3, SCE Bhopal, (INDIA) 3 Asst. Prof. GGITM Bhopal, (INDIA) The Montreal Protocol has sealed the use of Halogenated Hydrocarbons; keeping in view they affect the environment in the form of Ozone layer depletion and Global warming. Thus one of the major thrust areas is to identify substitute of Halogenated Hydrocarbons, especially CFCs. The substitute refrigerant should be ecofriendly, chemically stable and compatible with existing refrigeration systems with transport and thermal properties similar to or better than CFCs. Since the refrigeration system use CFC as refrigerant universally, the search for a suitable alternative for CFC is inevitable.hfc3a a is currently the leading alternative to CFC. Other promising substitutes are R3as a binary mixture of Rea &R3a ternary mixture of R 3a, R andra. In this paper, performance evaluation of ecofriendly alternate refrigerant R3a, R3a & R3a for replacing CFC has been done and a suitable alternative refrigerant for retrofitting has been identified. Keywords: Ozone depletion; Montreal protocol; ecofriendly refrigerant; hydrocarbon refrigerant; retrofitting. I. INTRODUCTION Recent studies have established that CFCs are depleting the Ozone layer and also contributed towards global warming. As due to favourable thermo dynamical and transport properties CFCs are used in the refrigeration system so there must be some alternative refrigerant, which is ecofriendly and having properties which are suited for refrigeration purpose. In, several countries across the world signed an international treaty, the Montreal protocol, to control substances that deplete the ozone layer. According to this protocol, countries would phase out CFCs and other ODS as per a given schedule, with a complete halt by. countries are signatories to the Montreal protocol. Under this agreement, the use of CFCs as refrigerants in all commercial and industrial refrigeration and airconditioning equipments has been banned in in all developed countries. Countries like India which have ODS consumption below the threshold annual value of.3 kg per capita are required to freeze the consumption of CFC by, then reduce the use by % by and complete phase out by (Agrawal, ). It is believed that if the international agreement is adhered to the ozone layer is expected to recover by. II. INDIA S COMMITMENT TO THE MONTREAL PROTOCOL India became party to the Montreal protocol on Sept,. India mainly produced and used seven of the substances controlled under the Montreal protocol. These are CFC, CFC, CFC3, Halon, Halon3, CTC, methyl chloroform and methyl bromide. India had prepared a detailed country programme (CP) in 3 to phase out ODS in accordance with its national industrial development strategy (INFRAS, ). The objectives of the CP were to phase out ODS without undue economic burden to both consumers and industry manufacturing equipments using ODSs and provided India with an opportunity to access the protocol s financial mechanism. The other objectives of the CP also include minimization of economic dislocation as a result of conversion to non ODS technology, maximization of indigenous production, preference to one time replacement, emphasis is on decentralized management and minimization of obsolescence. In, the total ODS consumption in the

Narayan et al. / International journal of Application of Engineering and TechnologyVol. No. refrigeration and airconditioning sector in India was, MT. This constituted about 3% of India's total consumption of CFCs. About twothirds of this consumption was estimated to be used in servicing of existing equipment. The growth rate in this sector was forecast at % annually until. The refrigeration and airconditioning sector was therefore identified as a priority sector in India for initiating phaseout activities (Kapil, ). III. RETROFITTING Imminent CFC shortages would threaten the useful life of the appliance of CFC equipment. As the CFC shortages increase, the cost of CFCs will rise, along with the operating costs of the equipment. Retrofitting is the only long term and the most effective solution for discontinuing and reducing the CFC emissions from existing appliances. Retrofitting is the process by which the equipment currently using an ODS refrigerant is made to operate on a non ODS refrigerant, without major effects on the performance of the equipment and without significant modifications or changes for the equipment, ensuring that existing equipment operates until the end of it s economic life. It has been proved by various case studied that retrofitting is economically viable in small scale refrigeration equipment (Othmar & Adrian, ) than in large capacity systems. IV. VAPOUR COMPRESSION REFRIGERATION SYSTEMS Figure Vapour Compression Refrigeration cycle The simple Vapour Compression Refrigeration cycle is shown in Fig.3. It consists of following four essential parts.compressor,.condenser, 3.Expansion Valve, and.evaporator.compressor compresses the vapour refrigerant to the condenser with high pressure and temperature, in the condenser condensation takes place by rejecting heat with cooling medium either water or air as a cooling medium the phase transfer takes place from vapour refrigerant to liquid refrigerant and enters into the Expansion Valve, the function of the expansion valve is to reduce the pressure from high condenser pressure to low evaporator pressure by throttling process, finally the liquid refrigerant enters in the Evaporator where cooling effect is produced by absorbing heat from the cooling space and only pure vapour enters into the compressor V. ECOFRIENDLY REFRIGERANTS R3A, R3A & R3A Recent studies have established that CFCs are depleting the Ozone layer and also contributed towards global warming. As due to favourable thermo dynamical and transport properties CFCs are used in the refrigeration system so there must be some alternative refrigerant, which is ecofriendly and having properties which are suited for refrigeration purpose. R3a is a blend of HFC 3a & HFCea that has been developed as a zero ODP replacement for CFC in existing refrigeration system. The composition or R3a is as follows (by weight %). Refrigerant HFC 3a HFCea R 3a.%.% R3 a is a blend of HFC3a, HFC & HC a that has been developed as a zero ODP replacement for CFC in existing refrigeration system. The composition or R3 is as follows (by weight %). Refrigerant HFC HFC HC 3a a R3a % % 3% New refrigerants like R3a and R3 a have been successfully tested in The USA and seem to be major retrofits for R. They are also not subjected to phase out under any amendment/law. Also they are compatible to the existing lubricants. Analysis of vapour compression refrigeration system can be carried out using thermodynamic properties of the working fluid. Prediction of the performance of compression refrigeration system at design and off design conditions needs repeated calculations. This necessitates the development of correlation for various properties such as vapor pressure, specific volume, saturated vapour and saturated vapour enthalpy as a function of temperature and pressure.

Narayan et al. / International journal of Application of Engineering and TechnologyVol. No. CORRELATION FOR SATURATED VAPOUR SPECIFIC VOLUME Correlation for vapour enthalpy for R3a, R3 a, R 3a and CFC as a function of temperature are given below. V g = (A+B*T)/ (+C*T+D*T ). The constants A, B, C, and D are given in table 3.. Table 3. Coefficients for vapour specific Volume correlation Refrige A B C D rant R.3.33.3. 3 R3a.3 R3. a R3a..3..3.3..3... CORRELATION FOR SATURATED LIQUID ENTROPY Correlation for liquid and vapour enthalpy for CFC, HFC3a binary blend R3a and ternary blends R3a as a function of temperature are given below. S L = A+B.T+C.T +D.T 3 +E.T +F.T. The constants A, B, C, D, E and F are given in table 3.. Table 3. Coefficients for saturated liquid entropy correlation Refriger A B C D E F ant R..3.3. 3.3 33 e e e R3a... e.33.. R3 a. R3a.... e. e e. e. e e. e.33 3 e CORRELATION FOR SATURATED VAPOUR ENTHALPY e. e.3 Correlation for liquid and vapor enthalpy for CFC, HFC3a, binary blend R3a and ternary blend R3a as a function of temperature are given below. H g = A+B.T+C.T +D.T 3 +E.T +F.T. The constants A, B, C, D, E and F are given in table 3.3. Table 3.3 Coefficients for specific Enthalpy of Vapor Correlation Refrigera A B C D E F nt R 3... R3a 3. R3 a 3. R3a 3........ e. e. e. e. e. e. e. e 3. e. e.3 e. e VI. ANALYSIS OF REFRIGERATION SYSTEM FOR REFRIGERATION UNIT The refrigeration system of ton cooling capacity has been chosen for the study. The system consists of the four usual components i.e. the compressor, condenser, evaporator and capillary tube (throttling device), as shown in figure. The operating conditions for the refrigeration unit in Indian conditions are as follows. Sl.No parameters. Condensing C, C and C Temperature Evaporator Temperature C, C, C, C, C 3. Superheating o C Subcooling o C Performance characteristics of reciprocating compressor are

Narayan et al. / International journal of Application of Engineering and TechnologyVol. No. Volumetric efficiency of compressor: The ratio of clearance volume v to the swept volume v p is called the clearance factor(c).c= v /v p This factor has been taken as.3(3%of v p ). The expression of volume efficiency is given by: =+cc*(v suction /d ischarge ) COP of vapour compressor refrigeration system: COP= Refrigeration Effect/Work Input VOLUMETRIC EFFICIENCY Figure Volumetric Efficiency vs. Evaporator Temperature at condenser Temperature ºC VOLUMETRIC EFFICIENCY......... EVAPORATOR TEMPERATURE ( O C) R R R3a R3a R3a R3a R3a R3a condenser temperature and c evaporator temperature. In fig.,, we can observe that Cop of the entire refrigerant are much closer, COP of the refrigerant R3a is closer to R than R3a & R3a. COP of R3a & R3a is very much closer in all the condition. The highest difference in COP is.3 between R and R3a. VOLUMETRIC FFICIENCY Figure Volumetric Efficiency vs. Evaporator Temperature at condenser Temperature ºC COEFFICIENT OF..... 3 R R3a R3a R3a R R3a R3a R3a Figure 3 Volumetric Efficiency vs. Evaporator Temperature at condenser Temperature ºC Figure Coefficient of performance vs. Evaporator Temperature at condenser Temperature ºC The performance analysis on the basis of volumetric efficiency of compressor and COP of vapour compressor refrigeration system has been carried out by using software & manual calculations for evaporator temperatures c, c, c, c,and c, and condenser temperatures c, c and c. The performance parameters have been calculated without considering subcooling & superheating. In figure, 3& we can see that the volumetric efficiency of refrigerant R3a is least compared to other refrigerants. The volumetric efficiency of refrigerant R is always more than that of other refrigerant. The highest efficiency is. for R at c for condenser temperature c. The maximum variation for volumetric efficiency is for R3 at c COEFFICIENT OF 3 R R3a R3a R3a Figure Coefficient of performance vs. Evaporator Temperature at condenser Temperature ºC 3

Narayan et al. / International journal of Application of Engineering and TechnologyVol. No. [] Retrofitting of vapour compression refrigeration trainer by an ecofriendly refrigerant Alka Bani Agrawal and Vipin Shrivastava Indian Journal of Science and Technology Vol. 3 No. (Apr. ) COEFFICIENT OF R R3a R3a R3a Figure Coefficient of performance vs. Evaporator Temperature at condenser Temperature ºC VII. CONCLUSION COP and Volumetric efficiency of compressor of R3a, R3a and R3a is nearly same to that of R. This also indicates the suitability of retrofitting of R3a, R 3a and R3a with an existing R system. Volumetric efficiency of compressor using R3a is slightly less than that of R. This is due to higher specific volume of R 3a. But this does not affect the performance of the system. Making an overall comparison, all three refrigerants R3a, R3a and R3a are attractive alternatives to CFC. Research results are favourable, with no major drawback. REFERENCES [] "Montreal protocol on substances that deplete the Ozone Layer "UNEP Report of the refrigeration, air conditioning and heat pumps technical options committee, Assessment. [] www. refrigerants.dupont.com, USA for thermodynamic tables of R3a and R 3a [3] "Thermodynamic study of a ternary Azeotropic mixture for Vapour Compression systems", Bansal V K, Mechanical Engineering Department, IIT Delhi. [] "Analysis of Vapour Compression Refrigeration system for Domestic Refrigerator Using EcoFriendly Hydrocarbon Mixture", Sameer Vaidya, Mechanical Engineering Department, JEC Jabalpur. [] Arora C.P., "Refrigeration and Airconditioning", TMH publication. [] Mukunda Mahajan, et al. Fabrication and experimental analysis of envelope air conditioning,intenational Journal of Application of Engineering and Technology, VolNo.PP.. [] Stocker and jones, "Refrigeration and AirConditioning", McGraw Hill publication.