Specification of full series of product,please read as per your need. Ver.A4 Smart Emergency System remote control Triproof ight series DC E482831 EMER. IGHT EQ. E482832 Product features Wide Beam Angle: Personalized fashion design and unique appearance, Meet wide bean angle lighting demands; Hipot: Buildin aluminum heat sink,with V0 FireRated PC housing, good cooling and improve safety factory, Hipot >5000V; IP5: Integral design and fully compact structure; Smart Sensor: Adopted most stable microwave sensor technology, achieve greatest energy saving; Intelligent Emergency system: Easier installation and cost saving by using Remote Control, compare to competitors product installation time decreased 1520mins,best choice of intelligent emergency lighting system; Full range of products: Emergency, Sensor, 010V DIM, ODIM, Emergency with sensor, Emergency with 010 DIM etc can be flexible combination (DIM without flickering); Dimension W 2 H W 2 H Type A & C Type B Model o. TP2FT20W (mm) 2(mm) W(mm) H(mm) A B C A B C A B C A B C 00 50 00 540 94 0 TP3FTW 900 950 900 840 94 0 TP4FT3W 1200 10 1200 1140 TP4FT45W 1200 10 1200 1140 94 0 94 0 TP5FT0W 1500 1550 1500 1440 94 0 TP8FT70W 2400 2450 2400 2340 94 0 Remark:There have three connection mode for your choice, A: with Input Wire B: Without input wire C: seamless connection, Please check connection mode in specification for more details. US distributor: E2 ighting USA 153 W. Rosecrans Ave. Gardena, CA 90248 E: sales@e2lightingusa.com Phone: (808) 9272395 Fax: (415) 704447
Product Function Instructions Sensor Microwave sensor, detecting area 510M. ondim Sensor (Picture 1) and Dim Sensor (Picture 2) available. ondim Sensor o motion detected in 3 mins. Detection of Movement Customized time available Dim Sensor energy saving (10% ~ 50% Optional) ( picture 1) o motion detected in 3 mins. energy saving (10% ~ 50% Optional) o motion detected in 5 mins. Off Detection of Movement Emergency ( picture 2) High Temp. imh battery, the highest charging temp. is up to 70. Smaller in size, longer lifetime, safer in practical use, RoHS compliant; The nickelmetal hydride batteries can be repeated 500 chargedischarge cycles by correct operation, If use emergency function once a week, the lifetime can be up to 8~10 years; After leaving factory,the emergency battery turns itself into a dormant state to avoid electric discharge and leakage; To ensure battery lifetime, this emergency product is designed to have a trimonthly charge and discharge cycle.users can close/start this fucntion by remote control,details please refer to remote control function instructions.(factory settings:automatic discharge fuction is ''start'' status;) The battery charge cycle is 24hrs. With dual protection of voltage detection and charging time detection, the battery could be prevented effectively overcharge and overdischarge, once any of the protections is triggered, circuit will automatically switch to an intermittent charge. Emergency lighting driver employs more advanced electronic relay, convert emergency in 200ms, that is two times faster than traditional coil relay to switch; Please make a emergency test every month for the lamp with Emergency backup. Operation: press the TEST button of wireless controller, if the lamp can switch to the battery powered, thenthe emergency backup is working. Conform to the safety requirements and Emergency products must ensure that the function of the emergency regulations,adopt wireless IR remote to control,without any external button and lead,savings in wiring and maintenance costs.(picture 3) Ceiling Others' TRIprooflight External driver Emergency kit Ceiling Alite TRIprooflight Buildin emergency of indicator light Emergency Driver ED Driver Indicator light of connecting line 2 Test switch of connecting line Control switch Buildin emergency kit Control switch Wireless remote control Reduce 1520mins per unit for installation emergency indicator light Save wiring material Emergency test switch Others ED Triproof ight ( picture 3) AITE ED Triproof ight
Remote Control Wireless IR Remote Control Instructions(Picture 4): Button#1: TEST (Press this button, switch to emergency lighting model. Emergency indicator light turns red) Button#2: DISCHARGE(Press this button, battery starts to discharge, emergency indicator shows up red until Button#3: STOP electrical discharge process is over. 5 sec later, this lamp switches to normal working state); 1.Stop discharge(pause discharge when in emergency status) 2.Cancel automatic discharge(keep pressing button 3 seconds, when red indicator flicker once, means closed every 3 month automatic discharge function.) 3.Start automatic discharge(keep pressing button 3 seconds, when red indicator continues flicker, means start every 3 month automatic discharge function.) Specification/Product Parameters Input voltage:90~305vac Power:20W~70W(customizable) Frequency:50/0Hz umen Efficacy:120M/W Or 140 M/W Power factor:>0.9 Beam angle:270 THD:<18% ifespan :50000H Operating temperature: ~40 ( Emergency minimum temperature 10 ) Model o Power (w) CCT(K) umens(m) 120lm/w 140lm/w Button#2 (DISCHARGE) Choose one Emergency CRI SDCM of the three (Customizable) Sensor A B C Button#1(TEST) Button#3(STOP) Diagram of remote control(emergency) (Picture 4) Dim (optional) DC(/) U(/) TP2FT20WA 20 0 2800 TP3FTWA TP4FT3WA 3 400 5040 TP4FT45WA 45 570 300 TP5FT0WA 0 780 8400 TP8FT70WA 70 890 9800 TP2FT20WDA 20 0 2800 TP3FTWDA TP4FT3WDA 3 400 5040 TP4FT45WDA 45 570 300 TP5FT0WDA 0 780 8400 TP8FT70WDA 70 890 9800 TP2FT20WSA 20 0 2800 TP3FTWSA TP4FT3WSA 3 400 5040 TP4FT45WSA 45 570 300 TP5FT0WSA 0 780 8400 TP8FT70WSA 70 890 9800 TP2FTWEA 0 2800 (only B) TP3FTWEA TP4FT3WEA 3 400 5040 TP4FT45WEA 45 570 300 (only B) TP5FT0WEA 0 780 8400 TP8FT70WEA 70 890 9800 () (only B) TP2FT2WEDA 0 2800 (only B) TP3FTWEDA TP4FT3WEDA 3 400 5040 TP4FT45WEDA 45 570 300 (only B) TP5FT0WEDA 0 780 8400 TP8FT70WEDA 70 890 9800 () (only B) TP2FTWESA 0 2800 (only B) TP3FTWESA TP4FT3WESA 3 400 5040 TP4FT45WESA 45 570 300 (only B) TP5FT0WESA 0 780 8400 TP8FT70WESA 70 890 9800 () (only B) Remark : 1.the lumens as above form shows that reference 4000k and above, will be lower at least 5% if 3000k &3500k. 2.The lumen of emergency according emergency power and lighting effect to calculate. 3.There have three connection mode for you choice, A :With Input Wire B:Without input wire C: seamless connection, Please check connection mode in Spec for more details.
Product Application Parking ot, Subway,arge Supermarket, Food Processing Factory,Animal & plant Farm,School &Hospital, Gas Station MTR Station, Airport,Office indoor lighting Installation Modes Drill Holes with a Diameter of mm Drill Fixing Screws Expanded Particle Hanging Wire Holder Adjusting Sling ength Rotationally Fixed Fixed by the Screwdriver Hanging Kits Screw the hanging kits to the The sling is connected by screws fixed to the. By hanging wire at the other end fastened triproof light suspended Suspending Installation Screw Screw Fixed by the Screwdriver The screw is fixed on the. The hook fastener is fixed on the screw. The triproof light fastening hooks hung up Screwing Installation Drill Holes with a Diameter of mm Drill Mounting Bracket Mounting Bracket Expanded Particle Fixing Screws Mounting Bracket Triproof Triproof Fixed by the Screwdriver Fix the installation kits to the Put Triproof light into the buckle hook Installation completed Surface Mount Installation
Mode of connection (For wiring details please reference to Instruction Manual) Three connection modes optional. A: Parallel connection with input lines ( ength of lines can be customized). Usually used projects have confirmed length of input lines. B:Parallel /series connection without input lines. Users can prepare any length of the input/output lines as per project requirements. And can use Metal Hose. Very flexible and good for stock. C: Seamless connection. Suitable for shopping mall,supermarket and other places that need series connection without any space between two lamps. A: Parallel connection with input lines( ength of lines can be customized). 0/110V Dimmer reference to the dashed part. ED1 ED2 ED Parallel connection quantity calculated by / withstand current. Wiring Diagram of parallel connection B:Parallel /series connection without input lines. 0/110V Dimmer ED1 ED2 Bare wire/ PVC pipe. Waterproof ED ( use PG9 connection hole) Remark: Please check the maximal power of product internal wiring as follow (use minimum #18 line for external wiring ): 120 voltage input, the total power of series connection lamps can not exceed 400W. 230 voltage input, the total power of series connection lamps can not exceed 800W. 277 voltage input, the total power of multiple series lamps can not exceed 1000W. PG9 waterproof connection hole PG 9 connector Series connection/inkable (Picture 1) Metal Hose connection hole.φ22mm. 0/110V Dimmer ED1 ED2 Metal Hose connection, ED nonwaterproof Remark: Please check the maximal power of product internal wiring as follow (use minimum #18 line for external wiring ): 120 voltage input, the total power of series connection lamps can not exceed 400W. 230 voltage input, the total power of series connection lamps can not exceed 800W. 277 voltage input, the total power of series connection lamps can not exceed 1000W. Series connection/inkable (Picture 2) Metal Hose 0/110V Dimmer PG9 connector Waterproof Metal Hose connection hole.φ22mm. 0/110V Dimmer Metal Hose connection, nonwaterproof PG9 waterproof connection hole ED1 ED2 ED ED1 ED2 ED Parallel connection (Picture 1) The quantity of parallel connection according to the electric current of '\' trunk. Parallel connection (Picture 2) PG9 connector Metal Hose
C : Seamless connection(ot Ip5) 0/110V Dimmer ED1 ED2 ED Remarks: 120 voltage input, the total power of series connection lamps can not exceed 400W. 230 voltage input, the total power of series connection lamps can not exceed 800W. 277 voltage input, the total power of series connection lamps can not exceed 1000W. connector Parts Information (Hanging Kits) (Metal Hose) ( PG 9 connector) (Buckles) (connector for seamless connection) Package information Model o. et Weight (Kg) Qty(pcs /CT) Gross Weight/CT(Kg) Carton Size (MM) TP2FT20W TP3FTW TP4FT3W TP4FT45W. 10.8 10.8 TP5FT0W 13.08 9 7.7 10.7 12.8 12.8 21.2 770*W230*H235 070*W230*H235 370*W230*H235 370*W230*H235 70*W230*H235 TP8FT70W 21.3.72 70*W230*H235 Remark:packing info of standard products reference only, please contact sales for others. o. 1 2 3 4 5 7 8 Packing contents ED TRIPROOF IGHT Instructions manual Hanging Kits (Optional) Metal Hose(Optional) PG9 connector (Mode B only) Buckles Remote Control ( Emergency only) Connector ( Mode C only)