Air Conditioner Accessory DRAIN WATER LIFT-UP KIT Installation Manual

Similar documents
TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

SYSTEM Inverter Air Conditioners

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

INVERTER SPLIT - TYPE

SYSTEM Inverter Air Conditioners

GDDEM10 DEHUMIDIFIER

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series

General safety precautions English

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

INSTALLATION MANUAL Duct Type Series MH FECA

AIR CONDITIONER (SPLIT TYPE) Installation Manual. Indoor Unit. Installation Manual 1 English. Kurulum kılavuzu 26 Türkçe.

Dishwasher Installation Manual

AIR CONDITIONER (MULTI TYPE) Installation Manual. Indoor Unit. Model name:

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM1403DT-A RAV-SM1603DT-A. Model name: Concealed Duct High Static Pressure Type

Operating and Installation Instructions

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

General safety precautions English

General safety precautions English

Installation Manual. All Model Numbers SERIES SPLIT-TYPE ROOM AIR CONDITIONER

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.

Service Manual Washing Machine

Installation Instructions

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

SYSTEM Inverter Air Conditioners

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

Daily maintenance and checks

CART & TROUGH ASSEMBLY for BRAISING PAN UNITS

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

hp Dust Collector With Vacuum Attachment

GRIND PRO DUAL OR DISC SANDER. Operator Manual

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

INSTALLATION MANUAL R410A Split Series

SUPER MODULAR MULTI SYSTEM AIR CONDITIONER

Self Cleaning decoration panel

Installation Instructions

SPECIFICATIONS FEATURES

User Guide Digital Bill Counter AB4000

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Bar Fridge USER MANUAL MB46W

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

IMPORTANT SAFETY RULES

INSTALLATION INSTRUCTIONS

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

Installation Instructions

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Viking Installation Guide

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Manual KS8-LCP 0-10 C0 2 TRANSMITTER. Instructions for :- KS8-LCP0-10 C02 Sensor

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Split-type Air-Conditioner

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

MODELS: KEH041A42, KEH041A47, KEH041A48. Safety Considerations for Installation of Drain Pan Heater

Installation Instructions

INSTALLATION MANUAL WARNING

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

SPLIT WALL-MOUNTED AIR CONDITIONER

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

General safety precautions English

FLOOR TYPE AIR CONDITIONERS

Installation Instructions

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. Installation manual Manuel d installation Manual de instalación

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Jacuzzi J-D300 Pool Cleaning System

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Installation Instructions

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

1. BEFORE INSTALLATION

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

ULTRA LOW TEMPERATURE FREEZER. User Manual

Split-type Air-Conditioner

Installation & Operating Guide

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Installation Instructions

User Guide. Portable banknote counter AB300

Installation Instructions

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Installation Instructions

7165 Dust Collector Owner s Manual

Mini-Rooter Operating Instructions

Transcription:

Air Conditioner Accessory RAIN WATER LIFT-UP KIT Installation Manual Caution WARNING Confirm correct model before installation and care should be taken during installation. Safety Precautions PAC-KE03M-F WT03396X01 Before beginning installation, please read and understand these "Safety Precautions." The following system is used to stress the importance of the safety-related item. Always read and follow them. There is a high potential that an error in handling could result in serious injury or death. There is the potential that an error in handling could result in serious injury corresponding to a condition. After reading this manual, pass it on to others who will be using the equipment. Those who will be operating the equipment should store this manual in a safe place where it is easily accessible for reference. This manual should also be provided to anyone moving or repairing the equipment. WARNING Always have the unit installed by Authorized Mitsubishi Representative or similar professional. Improper installation by the user could result in problems such as water leakage, electric shock or fire. Install the unit according to this Installation Manual. If the unit is installed improperly, water leakage, electric shock or fire may result. Always use the designated cables and connect them properly. When connecting the terminals, make sure that external forces from the cable are not being conveyed to the terminal and then tighten them securely. Improper or loose connections could cause excessive heat or fire. Only use Mitsubishi-approved accessories, such as an air cleaner, humidifier or electric heater. Always have such accessories installed by an Authorized Mitsubishi Representative or similar professional. Improper installation by the user may result in water leakage, electric shock or fire. Have all electric work performed by a properly licensed electrician. Electric work should be performed in strict adherence to procedures within this Installation Manual and current legislation. Always provide a dedicated power supply. If the capacity of the power supply is inadequate, it could result in problems such as electric shock or fire. Never modify the unit and always have repairs performed by an Authorized Mitsubishi Representative. Improper repair could result in problems such as water leakage, electric shock or fire. 1

PRES BEFORE INSTALLATION Never use for special applications such as storing food, plants, precision equipment or art. The quality of these items may deteriorate. Always provide adequate signal noise protection when installing in facilities such as hospitals and communication stations. Equipment at these facilities, such as inverters, in-house generators, high-frequency medical equipment, two-way communication equipment, may cause the air conditioner to operate improperly. Conversely, the signal noise from the air conditioner may affect the operation of medical equipment and two-way communication equipment and this could interfere with the medical treatment being given to patient's or cause disturbances or interference in video broadcasting equipment. Never use the unit in special environments. Special environments with high concentrations of oil, steam or sulphuric gases will reduce the performance of the air conditioning unit and cause its parts to deteriorate. Never install the unit where run-off could result in damage. If the humidity in the room exceeds 80% or if the drain becomes clogged, water may drain off of the indoor unit. When the unit is used for heating, there may be drainage from the outdoor unit. If required, provide collector and drain for the outdoor unit. PRES BEFORE REMOVAL AN ELECTRIC WORK Route wiring so that there is no tension. Use care when transporting the unit. Tension could cause the wire to break and this could Always use two or more people for lifting a product result in excessive heat or fire. weighing 20 kg. or more. Some products are packaged with plastic wrapping bands. Never use these for lifting or transporting the product. Never touch the fins on the heat exchanger. They are ispose of packing materials properly. sharp and could cause cuts. Never allow children to play with the plastic bags used for packaging. Always tear them up when disposing. A child could suffocate in these bags. PRES BEFORE TEST RUN Never touch the switch with wet hands. Electric shock could occur. ue to the high risk of personnel injury through contact with electrical, rotating and high temperature components. Never operate the air conditioner with the air filter removed. Particles will enter into the air conditioner and cause damage. Never operate the air conditioner with the panel or guard removed. Never turn off the power supply immediately after stopping the unit. Wait five minutes or more before turning off the power supply. Turning off the power supply before that time could result in water leakage or damage. 2

Model name Model grouping Control class Performance type Target models group A1 (K control) K control model 1.6~2.5 PEH-1.6EKA2, PEH-1.6EKHA2 PEH-2EKA2, PEH-2EKHA2 PEH-2.5EKA2, PEH-2.5EKHA2 group A2 (K control) K control model 3~6 PEH-3EKA3, PEH-3EKHA3 PEH-4EKSA3, PEH-4EKHSA3 PEH-5EKSA3, PEH-5EKHSA3 PEH-6EKSA, PEH-6EKHSA3 group B1 (J control) J control model 2, 2.5 PE-2EJA1, PE-2.5JA1 group B2 (J control) J control model 3~6 PE-3EJA1, PE-4EJSA1 PE-5EJSA1, PE-6EJSA (M-NET/A control) (M-NET/A control) M-NET, A control model M-NET, A control model 1.6~2.5, 20~80 PEA-P1.6EA, PEH-P1.6EAH PEA-P2EA, PEH-P2EAH PEA-P2.5EA, PEH-P2.5EAH PEFY-P20VMM-A, PEFY-P25VMM-A PEFY-P32VMM-A, PEFY-P40VMM-A PEFY-P50VMM-A, PEFY-P63VMM-A PEFY-P71VMM-A, PEFY-P80VMM-A 3~6, 100~140 PEA-P3EA, PEH-P3EAH PEA-P4EA, PEH-P4EAH PEA-P5EA, PEH-P5EAH PEA-P6EA, PEH-P6EAH PEFY-P100VMM-A PEFY-P125VMM-A PEFY-P140VMM-A Provided Parts In addition to this Installation Manual, the following parts are provided with the accessory. Please check that all of the parts are available. ITEM 1 RAIN PUMP ASSY. 2 RAIN SENSOR 3 PUMP COVER ASSY. 4 RAIN PAN COVER SHAPE Target models Q'TY group A1 group A2 group B1 group B2 1 1 1 1 3

ITEM 5 RAIN PAN COVER 6 RUBBER PLUG 7 INSULATION 8 RAIN HOSE SET RAIN HOSE SHAPE HOSE BAN INSULATION PIPE Target models Target models Q'TY group A1 group A2 group B1 group B2 ITEM SHAPE Q'TY group A1 group A2 group B1 group B2 1 1 1 1 9 LEA WIRE(PUMP) BLUE WHITE 10 LEA WIRE(PUMP) 1 1 WHITE 11 LEA WIRE(SENSOR) 12 WHITE 1 1 BAN (FOR INSULATION PIPE) LEA WIRE(SENSOR) RE ITEM 13 BAN 14 PTT SCREW 4X10 SHAPE Target models Q'TY group A1 group A2 group B1 group B2 3 8+1(RESERVE) 4

1 Installing the rain Pump The rain Pump must be fitted before installing the indoor unit. 1.Removing the rain pan (1) Remove the screw that fixes the drain pan. (2) Slide the drain pan in the direction (a), and unhook the drain pan catch near the drain pipe. (3) Slide the drain pan in the direction (b), and unhook the drain pan catch on the other side. (4) Remove the 2 screws that fix the drain pan cover, and remove it. 2.Installing the rain pump (1) Use five PTT Screws to fit the rain pump assy 1. <Caution> At this time, fit the drain sensor item 2 for group A and B models only. (2) Use two PTT Screws to fit the Pump cover assy 3. (3) Use one PTT Screw to fit the rain pan cover 45. <Caution> At this time, install drain pan cover 4 onto group A1, B1 and C1 models, and drain pan cover 5 on group A2, B2 and C2 models. (4) Install the drain hose set 8 onto the drain socket. Insert the drain hose into the socket, and fix with the hose band. After connecting the drain pipe, insulate with insulating pipe (fix with the enclosed band). 3.Plug the original drain port with the Rubber plug. (1) Put insulation 7 round the drain pipe to prevent dewing. (2) Plug the original drain port with Rubber plug 6. (3) Tie Rubber plug 6 securely on the drain port by Band C in order to prevent leakage. rain pan catch (drain pipe side) Pump cover assy 3 PTT screw Insulation 7 Band C rain pan cover rain hose set 8 9 rain pan fixing screw (a) rain pump assy 1 Make a gap surely be located upwar rain pan (b) rain pan cover45 Rubber plug 6 5

2 Wiring (1) Wiring connection For group A For group B For group C WHITE INOOR P.W.B. INOOR P.W.B. INOOR P.W.B. CN50 PUMP TRANS 10 LEA WIRE RAIN SENSOR RAIN PUMP RE CNP BLUE 9 LEA WIRE 11 LEA WIRE 12 LEA WIRE CN50 RAIN SENSOR RAIN PUMP CN31 CNP 9 LEA WIRE RAIN SENSOR RAIN PUMP Connect the drain sensor to CN50 with lead wire A. Connect the drain pump to CNP with lead wire 0. Connect the drain sensor to CN50 with lead wire B. Connect the drain pump to CNP with lead wire 9. Connect the drain sensor connector to CN31. Connect the drain pump to CNP with lead wire 9. (2) Once the wiring has been completed, use Band 8 to bundle the excess wiring. At Make sure that the lead connectors do not come in contact with the edge sections of the sheet metal. VIEW A PUMP WIRE SENSOR WIRE PUMP WIRE SENSOR WIRE VIEW A SENSOR WIRE AN PUMP WIRE 6

3 rain piping (1) The drain piping should be set so that it has a gradient of more than 1/100 from the discharge side. Use care in routing the pipe so that no traps or rises are formed in the layout. (Please refer to Fig. 3-1) (2) The drain should not extend for more than 20 meters laterally (not including the difference between low and high points). In addition, if the drain piping is long, make sure to use support brackets along the way to eliminate dipping in the piping. on't connect to air leakage pipe. There are times when the water will spurt out of the drain. (3) Use hard vinyl piping for the drain piping. (This is the common VP-25 type with an external diameter of ø32.) Always use a vinyl-based adhesive at all joints to prevent leakage. (4) If there is a collector pipe, as shown in Fig. 3-2, position the collector pipe 10 cm lower than the drain port of this unit. In addition, make sure the collector pipe has a gradient of more than 1/100. (5) o not install a vapor trap (odor lock) at the discharge port of the drain piping. (6) Carefully position the discharge port of the drain pipe so that there will be no possibility of odors being created. (7) o not insert the drain pipe into a sewer (soil) pipe. (8) The mounting port for the drain pipe can be up to 500 mm higher than the lower surface of the indoor unit. If there is some obstruction in the ceiling, carefully route the drain pipe around it with minimal rise. (Refer to Fig. 3-3) (9) Always use the drain hose for the indoor unit that has been provided. o not apply unreasonable force to the drain hose. Caution: Keep the rise in the drain pipe to an absolute minimum. If there is a long rise, water will flow back when the power is turned off. If the unit is left off for a season, fungus and alge could develop and cause odors. (10) Always use insulation on the drain pipe. Indoor Unit Fig.3-1 Indoor Unit 25cm 1.5 2m ownward Gradient of 1/100 Insulation Fig.3-2 Fig.3-3 Indoor Unit Support Bracket Make as large as possible - Approx. 10 cm. Collector Pipe Hard Type Vinyl Piping (VP-25) (Procure Locally) Less than 500mm 90 Vinyl Piping Elbow (Procure locally) Indoor Unit Less than 300mm Outdoor side Indoor unit Route the drain piping so that it ensures proper drainage. Ensure that there is enough warmth to prevent dewing. Improper piping insulation can result in water leakage which could damage the area where the unit has been installed. 7

4 Confirm rainage Confirm that the RAIN-UP system is operating properly in both heating and cooling cycles and that drainage is being performed correctly. Also check during operation that there is no water leaking from any of the joints. * If the unit is being installed in a new site, it is best to do the installation before the ceiling is built. (1) Use a water feed pump or other method to pour some water into the drain pan. When doing this, make sure that no water spills from the drain pan. Also use care not to splash water on the drain pump or drain sensor at this time. (2) Turn on the power for the indoor unit. Use the remote controller to select "Test Operation" mode. (Refer to the Installation Manual provided with the indoor unit for details.) Press the "Change Operation" button and set the unit to "Cooling." Confirm that drainage is taking place by looking at the clear hose. (3) After confirmation has been made, turn off the power. If it's during the heating season, remove the Rubber plug and allow the water to drain out. Be sure to replace the plug once the water has been drained out. Please double check the installation. 8