RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Similar documents
Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions

STANDARD FEATURES SPECIFICATIONS

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

NetworX NX-548E Receiver Installation Instructions

1125 PIR Motion Detector

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

RMS/RPX Reader. User Manual

1126 Series Ceiling Mount PIR Motion Detector

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Wireless ShatterPro Acoustic Sensor Installation Instructions

AdvisorOne Quick Operation Guide

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

HX-80NRAM. High Mount Outdoor Detector

status AW1 Plus WiFi Alarm System User Manual

Installation Guide for models:

Pet Immune SAW PIR Motion Sensor

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

TruPortal Wireless Locks Quick Reference

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

FTP-1000 Touchpad/Display Installation Manual

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Installation Instructions

Honeywell ENERGY SAVINGS KIT

Rev D 3/20/17

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Independent Zone Control (I.Z.C.)

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

UNC100 Integra Manual

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

CORNELL Emergency Response Systems

KT-100 Door Controller

Addendum for STI-6406 with Dual Access Control

180 Degree Ceiling Mounted Occupancy Sensors

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

SP-1000X. Panic Device Power Controller Installation Guide. Rev

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Caddx Installation Instructions Package

DOLKPS1KB Programming & Installation Manual

Installation Guide for models:

Commercial Series TriTech Motion Detector. Reference Guide

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

DOLKPL1KB DOLKPS1KB DOLKSF1KB

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Installation Instructions

Series. Access Power Controllers. Installation Guide

Analog Room Pressure Monitor RPC Series

D-Tect 2 GJD300 Quad PIR Movement Detector

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Long Range Radio Alarm Transmitter

Model 17A00 Expansion Enclosure

English. Italiano. Português. Françias. Español

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

AXS Strikemaster Engineering Manual

Interrogator 200 Audio Verification Module (AVM)

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Installation & Operations Manual

Exit Stopper. STI-6400 Series

The most affordable codeless arming and disarming available with a slim new look!

Advisor Advanced User Guide

Description. Optex Incorporated

Exit Stopper. STI-6400 Series

Remote Chexit Module (RCM) System. General Information

Wireless D.I.Y. Alarm Kit

LUX Hardwired - Installation Notes

S P A C E D E T E C T I O N

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Long Range Radio Alarm Transmitter

DE5300 Delayed Egress System. General Information

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

IDP-Zone-6 Six Zone Interface Module

Gate Mount Pool Alarms

Commercial Series TriTech+ Motion Detector with Anti-mask

Installation & User Manual V2.03

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

MANUAL RESET ALARM RELEASE

D-TECT 3 IP. GJD260 IP Motion Detector

Operating Instructions Transponder code lock - Part 2 (split decoder)

Challenger V8 & V9 User Manual

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Simon XTi Quick Operation Guide

SECURITRON MODEL XMS EXIT MOTION SENSOR INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide Introduction This is the Interlogix RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Instructions for models RCR-REX-W, RCR-REX-B, and RCR-REX-G. Figure 2: Remove the circuit board and cradle Installation Determine if the sensor will be ceiling or wall mounted. Avoid locating the sensor between double doorways where objects can be inserted through a crack to gain unauthorized entry. CAUTION: When handling the sensor, do not touch the lens window. To install the sensor, do the following: 3. Route wiring to the sensor mounting location. If you are using the wall plate, pull the wires through the cable entry hole (Figure 3). Figure 3: Mounting and wiring access 1. To open the front cover, insert a small screwdriver into the bottom of the locking tab and pull upward (Figure 1). Figure 1: Open the cover CAUTION: You must be free of static electricity before handling sensor circuit boards. Touch a grounded, bare metal surface before touching circuit boards or wear a grounding strap. 2. Remove the screw holding the circuit board (PCB) cradle axle to the back housing and carefully remove the circuit board with cradle from the housing (Figure 2). 4. Insert the mounting screws into the back (wall mount) or top (ceiling mount) mounting screw holes to fasten the back housing and wall plate, if used, to the wall or ceiling (Figure 3). 5. Reinstall the PCB/cradle and secure in place with the PCB axle screw (Figure 2). 6. Complete wiring connection (See Wiring on page 2). 7. Swing the front cover in place and walk test the sensor for appropriate coverage and function (see Initial power up on page 4. 2018 UTC Fire & Security. All rights reserved. 1 / 7 P/N 466-5444 REV A 8NOV18

Wiring This section provides examples of different wiring options. The options are all shown in the failsafe mode. Basic Hook-up Figure 4 shows the basic hook-up for the RCR-REX, a power supply and a magnetic lock. When the sensor sees motion, power is removed from the magnetic lock. Note: Failure to spike protect the sensor may result in shortening the life of the relay contacts. RCR-REX and a Keycard Reader Figure 6 shows the wiring normally used when a keycard reader is on one side of the door and the RCR-REX is on the other side of the door. Both swiping a keycard or the detection of motion by the RCR-REX will remove power from the magnetic lock. Figure 4: Basic hook-up Figure 6: RCR-REX and a keycard reader CAUTION: Spike Protection For DC powered systems, if the door lock does not contain a diode across the coil winding, install a diode across the door lock to prevent degradation of the lock relay contacts. The diode should have a current rating greater than the maximum lock current. Install the diode so that the cathode end with the bar is connected to the positive side of the coil. Many magnetic locks and electric door strikes have built in spike (diode) protection. If the lock is not spike protected, install a bridge rectifier, such as a KBL005, between the relay contacts and the magnetic lock/door strike as shown in Figure 5. Figure 5: Spike Protection Monitor Door Contacts (first option) In the monitor door contacts mode, a person entering the sensor s field of view will activate the relay and timer. Door contacts connected to terminal D will monitor if the door is open or closed. If the relay timer gets to ten seconds or less (if set for 16 seconds or greater) and the door is still open, the RCR-REX internal sounder will activate. The sounder will also active if the door is opened without first activating the sensor or keycard input. The sounder will remain on until the door is closed or by someone moving in the field of view (Figure 7). Figure 7: Monitor door contacts (first option) 2 / 7 P/N 466-5444 REV A 8NOV18

Monitor Door Contacts (second option) If the sensor is activated but the door is not opened, the relay will drop out after ten seconds. If the sensor is activated and the door is opened, and then closed, the relay will drop out after two seconds. This prevents unauthorized people from entering (Figure 8). Figure 8: Monitor door contacts (second option) R (input) Arm This pin is used to enable and disable the unit with an external signal. The unit will be disabled when R is grounded for more than 10 seconds. Thereafter, when R is ungrounded, the unit will be enabled. Motion detected by the unit up to 10 seconds after R is grounded and at least 100 milliseconds after R is ungrounded will start the relay timer. This pin must be switched with a dry contact or an open collector transistor referenced to COM (ground). S (input) Sounder This pin allows external control of the sounder that takes precedence over all other sounder modes. If the unit is powered up with S ungrounded, then the unit assumes that S is unused. Whenever S is grounded after power up, the unit assumes that S is being used to externally activate the sounder. Thereafter, when S is ungrounded for at least 100 milliseconds, the sounder will unconditionally turn on and stay on until S is grounded. Panic Button Many fire codes require a panic button to be part of the installation. The RCR-REX has an X (external) input (see X (input) external) for a normally open panic button or an internal timer panic button. When X input is grounded, the door will open. Two normally open devices may be connected to the X input (Figure 9). Figure 9: Panic Button This pin must be switched with a dry contact or an open collector transistor referenced to COM (ground). X (input) External This pin can be used by card readers, keypads, remote push buttons, and key locks to cause the sensor to start a timing cycle. If X is pulled to ground for at least 500 milliseconds and less than 3 seconds, the lock/monitor relay will unlock the door and the lock timer will start as if a person walked into the detection area. If X is grounded for more than 3 seconds, then the relay will stay in the unlocked state until X is allowed to go high. When X goes high and if the door is still open, the sounder will produce a beeping tone and the relay will remain in the unlocked state until the door closes. When the door closes, the relay will lock the door and shunt the door switch. This pin must be switched with a dry contact or an open collector transistor referenced to COM (ground). NC, C, NO (I/O) Monitor Relay Section Connect the monitor relay terminals across the normally closed contacts (NC) of the door switch and across the access control system. If there is no access control system, connect the normally closed contacts of the door switch across the monitor relay terminals. D (input) Door This pin is used to detect the state of the door switch. The door switch must be connected between pins D and COM (ground). If the unit is powered up with D ungrounded, the unit assumes that D is unused. If D is ever grounded after the unit is powered up, the unit assumes that D is being used to sense door position and the sounder will beep (if enabled) when the door is left open. If used, this pin must be switched with a dry contact or an open collector transistor referenced to COM (ground). See S2-7 (door monitor mode) on page 4. P/N 466-5444 REV A 8NOV18 3 / 7

T and T Tamper Switch These two pins connect to the tamper switch, which opens when the housing cover is opened. COM (I/O) Common or Ground These two pins are connected to ground and serve as the ground reference when using pins R, S, X, and D. DIP Switch Options The factory default (D) setting is on for all switches. S2-1 (sounder enable) On. Sounder is enabled for all modes (D). Off. Sounder is completely disabled. S2-2 (LED control) On. LED is enabled (D). Off. LED is disabled except during warm-up. S2-3 (timer reset mode) On. Relay timer does not reset with motion (D). Off. Relay timer resets with motion. S2-4, S2-5, S2-6 (relay time) These switches determine how long the lock relay stays energized when motion is detected (Table 1). Table 1: Relay Time Settings Relay time S2-4 S2-5 S2-6 1/2 seconds (D) On On On 1 second On On Off 2 seconds On Off On 4 seconds On Off Off 8 seconds Off On On 16 seconds Off On Off Initial Power Up After mounting and wiring the sensor, apply AC or DC power to the input power terminals (V+ and V-). Allow at least 2 minutes following power up for the sensor to stabilize before conducting any tests. To walk test the detection pattern, approach the door from all directions and watch the walk test LED for detection. See Pattern Adjustment if changes are required in the detection area. Reassemble the sensor and completely walk test again following any lens adjustment. To select the appropriate relay time, set the DIP switches as shown in DIP Switch Options on page 4. LED Indicator The LED turns red for the duration of the lock relay time when motion is detected and flashes twice per second during the 20-second warm-up period. The LED turns yellow when the radar detects motion. The LED turns green when the passive infrared (PIR) detects motion. Internal Sounder A continuous tone will sound 15 seconds prior to the end of the relay timer period. A beeping tone will sound at the end of the external input (X) signal if the door is open. Pattern Adjustment The RCR-REX has both PIR and radar detection patterns that may be adjusted independently. PIR Detection Pattern Figure 10 shows the passive infrared (PIR) detection pattern. 32 seconds Off Off On 64 seconds Off Off Off Figure 10: PIR Detection Pattern S2-7 (door monitor mode) On. Monitor the door switch (D). Off. Do not monitor the door switch. S2-8 (relay mode) On. Fail safe mode (D) is enabled. Off. Fail secure mode is enabled. 4 / 7 P/N 466-5444 REV A 8NOV18

To adjust the PIR detection pattern toward or away from the door opening, do the following: 1. Open the sensor cover; see Figure 1: Open the cover on page 1 and loosen the PCB axle screw (Figure 11). Figure 11: PIR Pattern Adjustment You can adjust the radar range from 3 to 15 ft. (0.9 to 4.57 m). To adjust the range, rotate the range adjustment control (Figure 13) to the desired position. The radar range is not affected by the PCB rotation during PIR range adjustment. The radar range can be set to just above the floor, to prevent door activation from objects that have been slipped under the door. After adjusting the radar range, carefully test to be sure undesired sources of motion will not be detected. Figure 13: Range Adjustment Control 2. Rotate the PCB to the desired position and tighten the PCB axle screw. Table 2 gives the suggested angle for a given mounting height. Table 2: Suggested Angles Mounting height Wall angle Ceiling angle 7 ft. (2.1 m) -10 +10 10 ft. (3.0 m) -20 +20 15 ft. (4.6 m) -30 +30 3. Close the cover. 4. Test to be sure undesired sources of motion will not be detected. Radar Detection Pattern Figure 12 shows the radar detection pattern. Operation By connecting the lock relay in series with the door lock and the monitor relay in parallel to the door switch and alarm circuit, the sensor will allow normal egress and will monitor alarms from the door being held or forced open. The sensor will monitor the operation of the door switch without affecting the access control system. When the sensor detects motion, the lock relay contacts open, unlocking the door, and the monitor relay contacts close, preventing an alarm from being sent to the access control system for a fixed time. The time is selected with the DIP switch from 1/2 to 64 seconds or until reset by the sensor. See DIP switch options on page 4. Figure 12: Radar Detection Pattern If the sensor does not detect the opening of the door switch within 10 seconds of sensor activation; the lock and monitor relays will return to their normal condition. If the relay timer is set to 8 seconds or shorter, the lock relay will change back to the normal condition when the relay timer times out. After the door switch opens and closes, the sensor will automatically cancel any remaining relay time if the door switch remains closed for at least 2 seconds. The sensor s sounder will produce a continuous tone to warn of an open door 15 seconds before the timer closes the lock relay contacts and opens the monitor relay contacts. Closing the door will silence the sounder. New movement within the detection area will restart the timer and reset the sounder. If the door is still open when the timer ends, the monitor relay contacts will open, which will cause an alarm signal to be sent to the access control system. P/N 466-5444 REV A 8NOV18 5 / 7

Fail Safe/F ail Secure Modes The lock relay operates in the failsafe mode (factory default) when the lock relay state during alarm is the same state as when the unit is not powered. During the power up period, the relay will be in the same state as during normal unalarmed operation. The lock relay operates in the fail secure mode where the lock relay state during normal unalarmed operation is the same as when the unit is not powered. During the power up period, the relay will be in the same state as during the alarm period. Note: The fail secure mode must be authorized by your local authority. Listed panic hardware shall be used to allow emergency exit from the protected area. Figure 14 shows the fail safe and fail secure modes relay contacts. Figure 14: Mask Installation Fail Safe/Fail Secure Modes Relay Contacts The RCR-REX has a mask included that allows you to adjust the PIR field of view. This may be necessary for some installations when the unit may be tripped by non-exiting foot traffic or other erroneous sources that are with the detection area. To install the mask, do the following: 1. Remove the appropriate segments of the mask to include the desired area of detection. 2. Open the RCR-REX cover and locate the PIR lens. 3. Slip the mask into the two side brackets that hold the PIR lens in place (Figure 15). Be careful not to dislodge the lens. 4. Close the cover. Figure 15: Mask installation Specification Voltage Current 12 to 30 VAC or VDC 23mA typical, 27mA maximum at 12 VDC 15mA typical, 17mA maximum at 24 VDC 31mA typical, 38mA maximum at 12 VAC 26mA typical, 29mA maximum at 24 VAC Time delay 1/2, 1, 2, 4, 8, 16, 32, 64 seconds ± 10%, selectable Alarm output DPDT (2 Form C) Maximum loop rating Loop type Tamper output Wire gauge Operating temperature Relative humidity RFI immunity Static immunity Lightning immunity Radar frequency Range Depth Width Mounting height Dimensions (W x H x D) Color Listings 2 A at 30 V AC/DC Closed, open 50 ma at 30 VDC AWG 14 to 22 (18 to 22 recommended) -20 to 122 F (-29 to 50 C) 10 to 95% non-condensing 20V/meter from 80 MHz to 1 GHz 8k V 2.4kV, 1.4 Joules 5.84 GHz 3 to 15 ft. (0.9 to 4.57 m) 7.9 ft. (2.4 m) 7 to 15 ft. (2.13 to 4.57 m) typical 7.4" x 1.76" x 1.85" (187.8 x 44.7 x 47 mm) Off-white, black, gray C UL-US Industry Canada CE (pending) FCC Product Ordering Product RCR-REX-W RCR-REX-B RCR-REX-G Description RCR-REX request-to-exit dual technology motion sensor, off-white RCR-REX request-to-exit dual technology motion sensor, black RCR-REX request-to-exit dual technology motion sensor, gray Note: The equipment should be installed in accordance with the National Electrical Code, ANSI / NFPA70. 6 / 7 P/N 466-5444 REV A 8NOV18

FCC Compliance This device complies with Part 15 of the FCC rules. Operation is subject to the following three conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. 3. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. FCC ID: CGGAA2 Disclaimer Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of UTC Fire & Security Americas Corporation, Inc. Contact Information www.utcfireandsecurity.com or www.interlogix.com For customer support, see www.interlogix.com/customer-support 2018 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of United Technologies Corporation. All rights reserved. November 8, 2018 P/N 466-5444 REV A 8NOV18 7 / 7