PR5. INSTRUCTION MANUAL IM846-U v0.4

Similar documents
CTT8 TEMPERATURE MONITOR DEVICE

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

MO n : 12JMC rév A

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

TSX 2 Magneto-Thermal protection device for electric loads.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Monitoring Devices 11/1

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

ESP TECHNOLOGIES LIMITED

SACE PR021/K SIGNALLING UNIT

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

Electronic control unit for gas leak detection with 4 detection zones

FEC400 Series. Installation Manual

INSTRUCTION MANUAL T-154. DOSSENA s.n.c. Via Federico Barbarossa s/n Cavenago di Adda tel Fax:

Model A1600 Series Annunciator

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

Model A1700 Series Annunciator

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

M15051) INSTRUCTION MANUAL

Dixell Installing and Operating Instructions release 7.0

Danfoss gas detection units

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Instructions for the fan motor control system, SILVER C

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Installation Guide for models:

EN54 MONOZONE CONTROL PANEL

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Metering systems 0548EN April 2014

SET-2000 Hi Level/Oil

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Remote alarm indicator and test combination MK2430

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

WIO200 Water In Oil measuring instrument

Thermal protection device for electric units

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

WARNING FIRE DOOR CLOSING

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

ACTIVE INFRARED BARRIER

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

WIO200 Water in oil sensor

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

AIS750 Series Alarm Annunciator

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Flostop TS D7E and A8E. Operation Manual

LAE10 LFE10. Use. Series 02

21-light Remote Annunciator. Owner s Manual

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

1.7. Insulation fault evaluators EDS460/490 EDS461/491

BSR Addressable Fire Detection control panel. Installation operation manual

INSTRUCTION MANUAL ENGLISH. Card Revision: Software Card Revision: Hardware 1.00 DOCUMENT SES-KS-1801MR3HE-E REV. 3

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

INT 69 YF Diagnose. Application. Functional description

INSTALLATION AND OPERATING MANUAL

PTE0705 Electric Fence Monitor

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

FX FIRE DETECTION SYSTEM

Flame Safeguards LFE10. Building Technologies HVAC Products

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

INSTRUCTION MANUAL T-935-FO ANALOGUE. TECSYSTEM S.r.l. TECSYSTEM S.r.l. protection relays. 12 protection relays

OGB Poly Care 2 Incubator Service Manual

OPTISENS TUR 2000 Technical Datasheet

SAFETY DEVICE 3 WITH VISIBLE LASER EMISSION MSD

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

PolyGard 2-channel Gas Controller MGC-03

IT system floor-standing distribution

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

Gira nurse call system Installation, start-up, operation. Gira emergency set

Power Supply Display Module PSDM. Installation and Operation Manual

DIGITAL ALARM UNIT Model ALU-AP

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Model A2100 Series Annunciator

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

DUAL OPTIC. Installation manual

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

Installation Guide for models:

Danfoss gas detection units

Flame Safeguards LFE10. Building Technologies HVAC Products

Door Release Power Supply

Transcription:

INTRUCTION MANUAL IM846-U v0.4 REMOTE IGNALLING AND CONTROL PANEL to join to the following devices for the permanent insulation control: HRI-R40 HRI-R22t HRI-R22 HRI-R24 HRI-R24N GENERAL The remote signalling panel type allows to see the alarm signalling from insulation control device in medical network in according to the relative standards. The device that can be joined are: HRI-R40 HRI-R22t HRI-R22 HRI-R24 HRI-R24N TET ILENCE remote signal panel - network insulation control ON OVER FAULT I The device HRI always controls the level of insulation and overload of hospital power supply lines (network IT-M). The alarm signalling of low insulation and/or overload could be signalled inside of rooms supplied from the same line thanks to panel, which has the corresponding signalling LED s on the front. These devices have inside an alarm buzzer, a TET key and a ILENCE key to stop the acoustic signalling. As request from the standard the signalling of the fail network must be indicated in all power room. The PR-5 can be installed in universal wall mounting boxes (E503) in order to be placed the rooms supplied by the network under control. In the box there are two stickers of identification joined control device, so to indicate on the front panel if the signal are referred to 230 V or 24V. instruction manual IM846-U v0.4 pag. 1 / 12

DECRIPTION remote signal panel - network insulation control 1 TET ON 4 ILENCE OVER FAULT I 2 5 3 7 6 LEGENDA: 1: Green LED to signal that the device is on (presence of power supply) 2: Red LED to signal the network overload (over temperature and/or over current) (only in the connection with HRI-R40 / HRI-R22t) 3: Yellow LED to signal a failure (low insulation) (with the HRI-R40 to signal system error or anomaly too) 4: TET button to verify the functionality of the system 5: ILENCE button to stop the acoustic alarm 6: Buzzer 7: Area to put the referring of the control device or the network under control The functions are: ignalling of device on with green LED [ON] ignalling of low insulation level with yellow LED [FAULT] ignalling of electrical or thermic overload with red LED [OVER] (only with the connection to HRI-R40 / HRI-R22t) Acoustic signalling of low insulation and overload alarm Push-button to silence the acoustic signalling [ILENCE] Push-button to test the functionality of the device [TET] instruction manual IM846-U v0.4 pag. 2 / 12

INTALLATION The installation must be carried out only by qualified and authorized personnel and in absence of voltage. Before carrying out the installation, make it sure that it has not suffered any damage during the transport. Make it also sure that the supply voltage of the product and the rated voltage correspond to the values prescribed for the instrument. The PR4 is formed by a frontal plate and a housing in which is mounted the electronic circuit of the device: both suitable for every type of universal box (E503): 9 10 11 s.n. 1 2 3 4 5 6 7 8 AEMBLY CONNECTION PANEL DIMENION 123 7 13 15 E503 TET ON OVER I 79 ILENCE FAULT TECHNICAL FEATURE Auxiliary power supply ignalling Buttons Connections Protection degree Dimensions enclosure Working temperature toring temperature Insulation tandard 12-24Vca/cc (from HRI or from 24V network) Max consumption 1,5 VA. green led: supply; red led: alarm, overload; yellow led alarm low insulation failure, acoustic BUZZER at 2400 Hz, intermittent 2 Hz TET button; ILENCE button screw terminals, max section 2,5 mmq IP40 frontal panel, IP20 rear panel flush mounted universal box E503 weight 200g -10 60 C, humidity 95% max -25 +80 C 2500 Vrms 50 hz for 60 sec safety CEI-EN 61010-1 product CEI-EN 61557-8 / CEI 64.8/7-710 V2/ IEC 60364-7-710 electromagnetic compatibility CEI-EN 61326-1 FUNZIONALITY and INTALLATION Depending the control device connected and the wiring the will do an self-configuration. After the connection of the panel to a control device and after the turning on, the will emit a sound to confirm the self-configuration. instruction manual IM846-U v0.4 pag. 3 / 12

Connection in completely mode to HRI-R40 devices The must be connected exclusively to the HRI-R40 to take the power supply (max 24V) and the I/O signal. For each HRI device can be connected in parallel max 4 PR-5. The signalling are the same in all devices. When there is a low insulation or overload of the network the relative frontal signalling will turn on and the acoustic signalling will be activated. When one of the silence button of the HRI or the panels is pressed, all the connected panels will be silenced. In the case of the alarm come back in the normal condition, all of the optical / acoustic signalling will be deleted. After the signalization of the alarm condition, on the HRI device it s possible to have more info on the measure. The alarm signalization can be activated in case of errors in the self-diagnostic test (as failures on temperature probes, none connection to the network under control, ecc.). For other info, it s necessary to see the instruction manual of HRI-R40. The technical features of these panels are in accordance with the standards of the application on IT-M networks. All the connection are made on the rear screw terminals. All wires will be connected to HRI or other panels. The maximum voltage is 24V supplied by the HRI. WIRING CONNECTION 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 R485 serial port (option) Vaux:* 115V 115V input 2 (o PTC) probe link fail insulation control control ingput 1 (o PTC) probe current input TA.../5A remote control panel relay output HRI-R40 12 13 14 15 16 17 18 remote control panel power supply Vaux: 230Vca TO OTHER PANEL L PC N IOLATED NETWORK (IT-M) INULATION TRANFORMER WIRING CONNECTION LEGEND The 8 wires of the connection between the control device and the panel are identified with a initials: - COM-P common panel - common of power supply and signal - V-P voltage panel - voltage supply of the panels, the output maximum voltage is 20 Vdc referred to COM-P common - ACU acustical signal - signal to activate the acoustic signalling - ACK acknowledge - signal to silence the acoustic signalling - OVER overload signal - signal to activate the overload signalling - FAULT fault insulation - signal to activate the fail insulation - TET-/TET+ test output - output to test the functionality power supply (from the HRI device) signal to activate the acoustic silence terminals 3-8 terminal 5 connection for TET function signal to activate the overload signalling terminals 9-11 terminal 6 signal to activate the acoustic signalling signal to activate the low insulation signalling terminal 4 terminal 7 instruction manual IM846-U v0.4 pag. 4 / 12

Connection to HRI-R22 devices The must be connected to the HRI-R22 to take the power supply and to the line under control to take the signal. It s possible to connect at maximum 2 panel for each HRI-R22 device. All wires will be connected at the same way on all panels. When there is a low insulation of the network the relative frontal signalling will turn on and the acoustic signalling will be activated. When one of the silence button of the HRI or the panels is pressed, all the connected panels will be silenced. In the case of the alarm come back in the normal condition, all of the optical / acoustic signalling will be deleted. For other info, it s necessary to see the instruction manual of HRI-R22. The technical features of these panels are in accordance with the standards of the application on IT-M networks. All the connection are made on the rear screw terminals. All wires will be connected to HRI, to the line and to the ground equipotential node for the test and to other panels. WIRING CONNECTION 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 HRI-R22 Vaux:* 230V link fail control insulation control remote control panel relay output 12 13 14 15 16 17 18 remote control panel power supply Vaux: 230Vca TO OTHER PANEL L PC N IOLATED NETWORK (IT-M) INUALTION TRANFORMER WIRING CONNECTION LEGEND The 5 wires of the connection between the control device and the panel are identified with a initials: - COM-P / COM- common panel - common of power supply and signal - V-P voltage panel - voltage supply of the panels, the output maximum voltage is 20 Vdc referred to COM-P common - F- fault - signal to activate the fail insulation - TET-/TET+ test output - output to test the functionality power supply (from HRI-R22 device) terminals 1-3-8 connection for TET function terminals 10-11 signal to activate alarm terminal 2 instruction manual IM846-U v0.4 pag. 5 / 12

Connection to HRI-R22t devices The connection are the same of the HRI-R22. The different is only one wire to signal the thermic overload. WIRING CONNECTION 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 HRI-R22t Vaux:* 230V link fail control remote control panel insulation control temperature relay output remote control panel PTC probe input relay output 12 13 14 15 16 17 18 pannello controllo remoto power supply Vaux: 230Vca TO OTHER PANEL L PC N IOLATED NETWORK (IT-M) INULATION TRANFORMER WIRING CONNECTION LEGEND The 6 wires of the connection between the control device and the panel are identified with a initials: - COM-P / COM- common panel - common of power supply and signal - V-P voltage panel - voltage supply of the panels, the output maximum voltage is 20 Vdc referred to COM-P common - F- fault - signal to activate the fail insulation - ACU overload signal - signal to activate the optical/acoustic signalling for thermic overload (special connection for HRI-R22t) - TET-/TET+ test output - output to test the functionality power supply (from HRI-R22t device) terminals 1-3-8 connection for TET function terminals 10-11 signal to activate alarm terminal 2 signal to activate overload terminal 6 instruction manual IM846-U v0.4 pag. 6 / 12

Connection to HRI-R24N devices The must be connected to the HRI-R24N and the network under control to take the power supply (max 24V) from HRI-R24N and the signal for the test. For each HRI-R24N device can be connected in parallel max 4 PR-5. The signalling are the same in all devices. When there is a low insulation of the network the relative frontal signalling will turn on and the acoustic signalling will be activated. When one of the silence button of the HRI or the panels is pressed, all the connected panels will be silenced. In the case of the alarm come back in the normal condition, all of the optical / acoustic signalling will be deleted. For other info, it s necessary to see the instruction manual of HRI-R24N. The technical features of these panels are in accordance with the standards of the application on IT-M networks. All the connection are made on the rear screw terminals. All wires will be connected to HRI, to the 24V line, to the ground equipotential node and to other panels. The maximum voltage of work is 24 Vdc/ac. WIRING CONNECTION insulation controller HRI-R24N remote signalling panel 1 2 3 4 5 6 7 8 9 V+ V- OUT-NO OUT-C OUT-NC 10 11 COM- F- V-P ACU ACK OVER FAULT COM-P TET- TET- TET+ TO OTHER PANEL L(+) N(-) IOLATED NETWORK 24V ca/cc INULATION TRANFORMER WIRING CONNECTION LEGEND The 5 wires of the connection between the control device and the panel are identified with a initials: - COM-P / COM- common panel - common of power supply and signal - V-P voltage panel - voltage supply of the panels, the output maximum voltage is 20 Vdc referred to COM-P common - F- fault - signal to activate the fail insulation - TET-/TET+ test output - output to test the functionality power supply (from HRI-R22t device) terminals 1-3-8 connection for TET function terminals 9-11 signal to activate alarm terminal 2 instruction manual IM846-U v0.4 pag. 7 / 12

Connection to HRI-R24 devices Il functioning is the same at the HRI-R24N. WIRING CONNECTION insulation controller HRI-R24 remote signaslling panel 1 2 3 4 5 6 7 8 9 V+ V- OUT-NO OUT-C OUT-NC 10 COM- F- V-P ACU ACK OVER FAULT COM-P TET- TET- TET+ TO OTHER PANEL L(+) N(-) IOLATED NETWORK 24V ca/cc INULATION TRANFORMER WIRING CONNECTION LEGEND The 5 wires of the connection between the control device and the panel are identified with a initials: - COM-P / COM- common panel - common of power supply and signal - V-P voltage panel - voltage supply of the panels, the output maximum voltage is 20 Vdc referred to COM-P common - F- fault - signal to activate the fail insulation - TET-/TET+ test output - output to test the functionality power supply (from HRI-R22t device) terminals 1-3-8 connection for TET function terminals 9-11 signal to activate alarm terminal 2 instruction manual IM846-U v0.4 pag. 8 / 12

Connection to HRI-R40 devices in reduce mode DIFFERENCE WITH HRI-R40 AND HRI-R22(T) CONNECTED TO PANEL There are fundamental differences in some functions of the panels depending on the type of HRI connected. In the case of HRI-R22(t) you will get the following differences: Acknowledging signalling device (ACK) With the HRI-R40 version it s possible to silence the acoustic signalling from the HRI-R40 and from each panel, by pressing the REET push-button. In the HRI-R22(t) versions each acoustic signalling must be silenced from the relative remote signalling panel and it s no possible to manage on the HRI. Overload signalling (OVER) The overload signalling has the same differences. This function, with relative LED on the panel, is possible only with HRI- R40 and HRI-R22t versions. TET function In the HRI-R40 versions, the TET is carried out thanks a signal from the panels to the HRI-R40 device to simulate a fail condition. In the HRI-R22(t) versions, the TET is carried out directly on the isolated line: the real insulation is regulated to 35 Kohm about. In some standard the TET function must be carried out without to change the real insulation of the line. In the Italian standard CEI64.8/7-710 V2 there s no indication. instruction manual IM846-U v0.4 pag. 9 / 12

CONNECTION WITH HRI-R40 WITH 5 WIRE In a system already built, in the case of replacement of the HRI-R22(t) and PR1/2 with HRI-R40 and, it s possible to find difficulty in the correct connection of the remote signalling panels because only 5 wires were used instead of the 8 wires used now. With the last version of panel It s possible to realize the following connection: 5 wires Variant 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 R485 serial port (option) Vaux:* 115V 115V input 2 (o PTC) probe link fail insulation control control input 1 (o PTC) probe current input TA.../5A remote control panel relay output HRI-R40 12 13 14 15 16 17 18 pannello controllo remoto power supply Vaux: 230Vca TO OTHER PANEL L PC N IOLATED NETWORK (IT-M) INULATION TRANFORMER In this way, using the reduced functionality of test and reset of the HRI-R22(t) version and signalling all the alarm condition with the yellow LED, it s possible to use only 5 wires instead of the 8 required in the complete connection of the HRI-R40. instruction manual IM846-U v0.4 pag. 10 / 12

Connection TET modify It s possible to keep the same test mode used by the HRI-R22(t) in the HRI-R40 version (with the same disadvantages saw before but in the case of exchange of component, it could be necessary to keep the same TET condition). For this modify it s necessari to follow this wiring connection: 5 Wires Varian 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 serial port R485 (option) Vaux:* 115V 115V input 2 (o PTC) probe link fail insulation control control input 1 (o PTC) probe current input TA.../5A remote control panel relay output HRI-R40 12 13 14 15 16 17 18 remote control panel power supply Vaux: 230Vca TO OTHER PANEL L PC N IOLATED NETWORK (IT-M) INULATION TRANFORMER It s necessary to connect the terminal 10 and 11 between ground ( node) and the isolated network (on neutral or phase). instruction manual IM846-U v0.4 pag. 11 / 12

Contrel elettronica srl - I-26900 LODI - ITALY - via. Fereolo, 9 Tel. ++39 0371 30207/30761 Fax. +39 0371 32819 E-mail: contrel@contrel.it www.contrel.it instruction manual IM846-U v0.4 pag. 12 / 12