Make the Connection. Compatibility Guide for Noninvasive Systems Validated With INOmax DS IR Plus

Similar documents
Ref: TB ENG Issue date: June Plus or INOflo DS

PRODUCT OVERVIEW. Adult Care Solutions

product overview Adult Care Solutions

HAMILTON-H900. Intelligent humidification for all patient groups

Deutsche Bank Securities 27th Annual Health Care Conference

Humidification & Filtration

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN)

Forward Looking Statements

NZX Australasian Media Day 12 November 2003

Overview & H1/Q2 FY03 Update Auckland, Wellington, Melbourne, Sydney November 2002

Instructions For Use. Hybernite ROC 2300 Rainout Control System

System Contents Your REMstar Pro C-Flex+ system includes the following items: Reusable gray foam filter Disposable ultra-fine filter (optional)

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

Data Sheet... HANS RUDOLPH, inc. HANS RUDOLPH, inc.

Active Humidification

Operator s Manual Infant Flow SiPAP

Infant Flow SiPAP. Operator s manual

GoodKnight 425. Patient Manual. Ref. : M-145DFU00-40 Revision A

Service Manual. Infant Flow SiPAP. Model M675. Copyright 2005, VIASYS Healthcare Respiratory Care

GE Healthcare. ivent 201 Catalog

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

USER Manual JR 10/02/06

740 SELECT. Multi-Parameter Monitor

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Puritan Bennett 980 Ventilator System Planning for Training Checklist

AEROpart Oxygen-accessories

WILAmed AIRcon Respiratory Gas Humidifier. Experience High Tech Respiratory Gas Humidification. Made in Germany

Invacare Platinum Mobile

Professional Design Project

Operating Manual. Model HC254

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

Adult and paediatric ventilators. Quick Setup Guide. English

301-P2000. Humidifier Heater, 115V. Instructions for Use. Pegasus Research Corporation, 1518 E Edinger Ave., Unit A, Santa Ana, CA 92705

GoodKnight H 2 O. User's Manual. Heated Humidifier. Ref. : M-146DFU00-20 Revision D

A U T O S E R I E S Operating Manual

FISHER & PAYKEL HEALTHCARE CORPORATION LIMITED ANNUAL SHAREHOLDERS MEETING 20 AUGUST 2014 ADDRESS BY TONY CARTER, CHAIRMAN

Oxygen Concentrator Instruction Booklet

Humidification for patients with respiratory failure

ACCESSORIES ISLEEP VIVO Z1

CPAPSolutions. Product Profile. Overview: The Family of SleepStyle TM CPAP Solutions

LTV Series ventilators

EC DECLARATION OF CONFORMITY

CLINICAL MANUAL REF JH 6/7/10 CLINICAL MANUAL

Respiratory Function Solutions Sensor and Sampling Line Guide. Nellcor with OxiMax Technology Product Guide A Full Line of Oximetry Sensors

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

DreamStation Service & Technical Reference Manual

In the 1940s in Chicago, Illinois, a group of oxygentank technicians began meeting with doctors concerned with lung disease. This group named itself

OUR CLIENTS WE CARRY OUT

A basic introduction about the principles of humidity

Product Specifications

VPAP COPD. H5i. Welcome Guide. Making quality of care easy. Respiratory Care Solutions. English NONINVASIVE VENTILATOR HEATED HUMIDIFIER

Adjusting the Pulse Flow Setting

T1 BEDSIDE MONITOR GUIDELINE

Thoracic drainage. Helping improve patient outcomes

OXYGEN CONCENTRATORS Information For Our Customers

Setting Up the Dash CapnoFlex LF CO2 Module

Redefining Healthcare Solutions

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

Contraindications Positive airway pressure therapy may be contraindicated in some patients with the following preexisting

Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

RESmart CPAP System. User Manual

Table of contents. New. New. New. New. New. New. New. New. New. New. New

English Please read the entire Information and Welcome Guides before using your device.

REMstar Auto A-Flex USER MANUAL

S9 Series AutoSet & Elite

REMstar Auto A-Flex USER MANUAL

Quick start guide for Altrix Precision Temperature Management System

Transcend Heated Humidifier User Manual

PAP Disinfecting Device User Guide. For all PAP Devices (Positive Airway Pressure) CPAP, APAP, Bi-PAP

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter

Cl inician Training Packet

Non-invasive/invasive ventilators. User Guide. English

SimplyGo Mini. User Manual REF R05 JH 08/01/2016 EN-INTL

Suction and Oxygen Therapy Range SUCTION AND OXYGEN THERAPY SOLUTIONS

bibag System User s Guide

DreamStation. BiPAP autosv REF R04 HM 01/30/2017 EN-DOM. User manual

Environmental Monitoring SmartSlot Card

BiPAP Pro Bi-Flex USER MANUAL

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

Home Medical Equipment Oxygen

Homecare catalogue and long term care facilities. International

VPAP ST VPAP S AutoSet CS S9 Auto 25

Invacare XPO 2 Portable Concentrator

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

User guide User guide English

User guide User guide English

Getting Started. Genesis Touch System

MaxiCompressor. evo. High Performance 50 PSI Compressor TH PLACE ADEL, IOWA 50003

INFECTION PREVENTION AND CONTROL MASTER EQUIPMENT CLEANING & DISINFECTING MANUAL

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

U S E R M A N U A L. Portable Oxygen Concentrator SAVE THESE INSTRUCTIONS

Neonatal Ventilator NV8

Blood/Fluid Warmer. The blood/fluid warmer is used to provide safe and effective warming of blood, blood products, and liquids.

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

R00 JH 1/23/2015 SimplyGo Mini

The Memorial Souad Kafafi Medical Center Skills Competency Checklist

THE MEDIX Actineb. Technical Specifications. % Particles < 5 um 75% * Class II BF. Intermittent (use for 60 Type Rating

Quick start guide. English

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

ila ACTIVVE SYSTEM PLATFORM

Transcription:

Make the Connection Compatibility Guide for Noninvasive Systems Validated With INOmax DS IR Caution: U.S. Federal and Canadian law restrict this device to sale by or on the order of a licensed medical practitioner. Outside the U.S.A. and Canada, check local laws for any restrictions that may apply. Applications The INOmax DSIR Delivery Systems deliver INOMAX (nitric oxide) gas, for inhalation. The INOmax DSIR Delivery Systems must only be used in accordance with the indications, usage, contraindications, and warnings and precautions described in the INOMAX package inserts and labeling. The approved patient population is limited to neonates. Refer to the INOMAX Full Prescribing Information prior to use. Please see WARNINGS on the back cover card.

Overview INOmax DS IR is validated with multiple noninvasive ventilation systems Validated with CPAP, high-flow nasal cannula, standard nasal cannula, and ventilators used with intubated patients* Babi. Bubble PAP Valve and Pressure Relief Manifold Vyaire AirLife ncpap Fisher & Paykel Healthcare Bubble CPAP Fisher & Paykel Healthcare RT329 Breathing Circuit & BC Nasal Cannula Fisher & Paykel Healthcare RT202 Breathing Circuit & Optiflow Adult Interface Noninvasive ventilation systems Hamilton Arabella Nasal CPAP Standard Neonatal Nasal Cannula Hudson RCI Neptune Heated Humidifier With ConchaSmart Technology Vapotherm Precision Flow Vyaire Infant Flow Nasal CPAP Vyaire Infant Flow SiPAP Warning: The approved patient population for the INOmax DS IR, as specified in the drug labeling for INOMAX (nitric oxide) gas, for inhalation, is limited to neonates. The INOmax DS IR is not intended to be used in other patient populations. * For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR and INOmax DS IR Operation Manuals, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. These ventilators have been discontinued. For a general list of warnings, please see the attached WARNINGS card. Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. 2018 Mallinckrodt. US PRC/dvINT/0816/0014(2) July 2018 www.inomax.com

Babi. Bubble PAP Valve and Pressure Relief Manifold 15 14 13 12 11 1. Oxygen Source 2. Oxygen Tubing 3. Pressure Relief Manifold 4. Injector Module 5. Temperature Probe 6. 90 Degree Sample Port Adapter 7. Nasal Prongs 8. Babi. Bubble PAP Valve 9. Tee Adapter 10. Breathing Circuit 11. Humidifier Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card. 1 2 3 4 10 9 5 6 8 7 12. NO/N 2 Injector Tube 13. Injector Module Electrical Cable 14. INOmax DS IR 15. Patient Gas Sample Line With Nafion Babi. Bubble PAP Valve and Pressure Relief Manifold

BABI.PLUS BUBBLE PAP VALVE AND PRESSURE RELIEF MANIFOLD MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. Babi. Bubble PAP Valve used with permission from Respiralogics. 2018 Mallinckrodt. US PRC/dvINT/0816/0014b(2) June 2018 www.inomax.com

Vyaire AirLife ncpap System* 1 2 3 4 1. INOmax DS ir 2. Heated Delivery Circuit 3. Infant Flow System 4. Infant Flow Generator 5. Sample Tee 6. Temperature Probe Vyaire AirLife ncpap System 7. Patient Gas Sample Line With Nafion 8. Humidifier 9. 22F x 15M Adapter 10. Injector Module 11. NO/N 2 Injector Tube 12. Injector Module Electrical Cable 12 11 10 9 8 7 6 5 *This ventilator has been discontinued. Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card.

VYAIRE AirLife ncpap SYSTEM MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. Vyaire and AirLife ncpap are 2018 copyrights of Vyaire Medical, Inc. Imagery used with permission. CF/802/18/0045 2018 Mallinckrodt. US PRC/dvINT/0816/0014c(1) July 2018 www.inomax.com

Fisher & Paykel Healthcare Bubble CPAP System 16 15 14 13 4 4 12 1 Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card. 2 3 5 11 6 Please refer to Fisher & Paykel Healthcare user instructions for correct products and setups. 10 7 8 9 1. Oxygen Source 2. Oxygen Tubing 3. Bubble CPAP Pressure Manifold (white) 4. 22F x 15M Adapter 5. 22M/15F x 22M/15F Adapter 6. Injector Module 7. Temperature Probe 8. Nasal Prong Infant Interface 9. Bubble CPAP Generator 10. F/P Inline Infant Nebulizer Kit (RT010) Adapter 11. Breathing Circuit 12. MR850 Humidifier 13. NO/N 2 Injector Tube 14. Injector Module Electrical Cable 15. INOmax DS ir 16. Patient Gas Sample Line With Nafion Fisher & Paykel Bubble CPAP System

FISHER & PAYKEL HEALTHCARE BUBBLE CPAP SYSTEM MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. The bubble CPAP imagery is used with permission of Fisher & Paykel Healthcare. 2018 Mallinckrodt. US PRC/dvINT/0816/0014d(2) June 2018 www.inomax.com

Fisher & Paykel Healthcare RT329 Breathing Circuit & BC Nasal Cannula 1 3 4 5 6 9 7 8 5 2 10 1. Patient Gas Sample Line With Nafion 2. INOmax DS IR 3. Oxygen Source 4. Oxygen Tubing 5. 22F x 15M Adapter 6. Injector Module 7. Pressure Relief Manifold 8. 22M/15F x 22M/15F Adapter 9. Injector Module Electrical Cable 10. NO/N 2 Injector Tube 11. MR850 Humidifier 12. Breathing Circuit 13. Temperature Probe 14. Gas Sample Tee 15. Nasal Cannula Fisher & Paykel Healthcare RT329 Breathing Circuit & BC Nasal Cannula 15 14 13 12 11 Please refer to Fisher & Paykel Healthcare user instructions for correct products and setups. Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card.

FISHER & PAYKEL HEALTHCARE RT329 BREATHING CIRCUIT & BC NASAL CANNULA MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. The RT329 Breathing Circuit & BC Nasal Cannula imagery is used with permission of Fisher & Paykel Healthcare. 2018 Mallinckrodt. US PRC/dvINT/0816/0014e(2) June 2018 www.inomax.com

Fisher & Paykel Healthcare RT202 Breathing Circuit & Optiflow Adult Interface 16 15 14 13 12 11 Please refer to Fisher & Paykel Healthcare user instructions for correct products and setups. Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card. 10 1 3 4 5 9 6 8 7 2 1. Patient Gas Sample Line With Nafion 2. INOmax DS IR 3. Oxygen Source 4. Breathing Circuit Hose 5. Injector Module 6. Injector Module Electrical Cable 7. NO/N 2 Injector Tube 8. 22F x 15M Adapter 9. MR850 Humidifier 10. Breathing Circuit 11. Temperature Probe 12. Gas Sample Tee 13. 22M/15F x 22M/15F Adapter 14. 22 mm ID x 22 mm ID Cuff Adapter 15. Optiflow Tracheostomy 16. Optiflow Nasal Cannula Fisher & Paykel Healthcare RT202 Breathing Circuit & Optiflow Adult Interface

FISHER & PAYKEL HEALTHCARE RT202 BREATHING CIRCUIT & OPTIFLOW ADULT INTERFACE MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR WARNING: The approved patient population for the INOmax DS IR, as specified in the drug labeling for INOMAX (nitric oxide) gas, for inhalation, is limited to neonates. The INOmax DS IR is not intended to be used in other patient populations. Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. The RT202 Breathing Circuit & Optiflow Adult Interface imagery is used with permission of Fisher & Paykel Healthcare. 2018 Mallinckrodt. US PRC/dvINT/0816/0014f(2) June 2018 www.inomax.com

12 11 Hamilton Arabella Nasal CPAP System* 13 1 2 3 1. Arabella 2. Patient Gas Sample Line With Nafion 3. INOmax DS ir 4. NO/N 2 Injector Tube 5. Injector Module Electrical Cable 6. Injector Module 7. 22F x 15M Adapter 8. Humidifier 9. Heated Delivery Circuit 10. Temperature Probe 11. Universal Generator 12. Arabella Sample Tee 13. 90 Degree Sample Port Adapter Hamilton Arabella Nasal CPAP System 10 9 8 7 6 5 4 *This ventilator has been discontinued. Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card.

HAMILTON ARABELLA NASAL CPAP SYSTEM MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. Arabella imagery used with permission from Hamilton Medical. 2018 Mallinckrodt. US PRC/dvINT/0816/0014g(1) July 2018 www.inomax.com

Standard Neonatal Nasal Cannula 1 2 3 4 5 4 6 5 4 3 10 11 12 7 8 1. O 2 Flowmeter 2. O 2 Tubing 3. 15M x 4.5 mm Adapter 4. 22M/15F x 22M/15F Adapter 5. 300 mm of 22-mm Hose 6. Injector Module 7. O 2 Tubing Sample Tee 8. Patient Nasal Cannula 9. Patient Gas Sample Line With Nafion 10. INOmax DS IR 11. Injector Module Electrical Cable 12. NO/N 2 Injector Tube The INOmax DS IR can be used with nasal cannula to deliver INOMAX (nitric oxide) gas, for inhalation concentrations from 5 to 80 ppm and an oxygen flow rate as low as 2 L/min. Conditioning of the oxygen flow prior to delivery through the injector module will help ensure the most accurate flow measurement. Conditioning can be achieved by adding 300 mm of 22-mm hose between the oxygen tubing and the Injector Module. WARNING: Do not use the integrated pneumatic backup with flow rates less than 5 L/min. Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card. 9 Standard Neonatal Nasal Cannula

STANDARD NEONATAL NASAL CANNULA MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. 2018 Mallinckrodt. US PRC/dvINT/0816/0014h(1) June 2018 www.inomax.com

1 Hudson RCI Neptune Heated Humidifier With ConchaSmart Technology 12 13 14 2 3 4 18 11 17 10 15 16 9 5 6 7 8 1. Patient Gas Sample Line With Nafion 2. INOmax DS ir 3. Injector Module 4. System Pressure Relief Valve 5. Air/O 2 Blender or O 2 Blender 6. O 2 Tubing 7. Temperature Probe (Short Cable) 8. Angled 22 mm Connector 9. Patient Circuit 10. Temperature Probe Connector 11. Second Temperature Probe Connector 12. Comfort Flo Cannula 13. Injector Module Electrical Cable 14. NO/N 2 Injector Tube 15. 22F x 15M Adapter 16. ConchaTherm Heated Humidifier 17. Temperature Probe (Long Cable) 18. 90 Degree Sample Port Adapter Hudson RCI Neptune Heated Humidifier With ConchaSmart Technology Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card.

HUDSON RCI NEPTUNE HEATED HUMIDIFIER WITH ConchaSmart TECHNOLOGY MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. Image courtesy of Teleflex Incorporated. 2018 Teleflex Incorporated. All rights reserved. 2018 Mallinckrodt. US PRC/dvINT/0816/0014i(2) June 2018 www.inomax.com

Vapotherm Precision Flow System 1. Patient Gas Sample Line With Nafion 3 1 2 2. INOmax DS ir 3. Precision Flow Unit 4. Injector Module 5. Patient Delivery Tube 6. O 2 Tubing Sample Tee 7. Patient Cannula 8. Injector Module Electrical Cable 8 9 9. NO/N 2 Injector Tube Vapotherm Precision Flow System 7 6 5 4 The INOmax DS IR adds NO/N 2 gas flow to the breathing circuit flow in proportion to the NO setting (up to 10% at 80 ppm) and subtracts gas from the breathing circuit via gas sampling at a nominal flow rate of 0.23 L/min These effects impact the delivered gas flow rate when using the Vapotherm Precision Flow. It is recommended that after an NO setting change the user checks the delivered gas flow rate and adjusts the gas source flow rate as necessary Follow all manufacturer instructions for connection to the Vapotherm Precision Flow Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card.

VAPOTHERM PRECISION FLOW SYSTEM MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. Precision Flow imagery used with permission from Vapotherm Corporation. 2018 Mallinckrodt. US PRC/dvINT/0816/0014j(2) June 2018 www.inomax.com

Vyaire Infant Flow Nasal CPAP System* 1 2 12 11 10 9 8 7 6 5 1. INOmax DS ir 2. Heated Delivery Circuit 3. Infant Flow System 4. Infant Flow Generator 5. Sample Tee 6. Temperature Probe 7. Patient Gas Sample Line With Nafion 8. Humidifier 9. 22F x 15M Adapter 10. Injector Module 11. NO/N 2 Injector Tube 12. Injector Module Electrical Cable Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card. 3 4 *This ventilator has been discontinued. Vyaire Infant Flow Nasal CPAP System

VYAIRE INFANT FLOW NASAL CPAP SYSTEM MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. Vyaire and Infant Flow nasal CPAP are 2018 copyrights of Vyaire Medical, Inc. Imagery used with permission. 2018 Mallinckrodt. US PRC/dvINT/0816/0014k(1) July 2018 www.inomax.com

Vyaire Infant Flow SiPAP System 1 2 3 4 5 1. INOmax DS ir 2. Abdominal Respiratory Sensor 3. Transducer Interface 4. Infant Flow SiPAP 5. Infant Flow Generator 6. Sample Tee 7. Temperature Probe 8. Heated Delivery Circuit 9. Humidifier 10. 22F x 15M Adapter 11. Injector Module 12. Injector Module Electrical Cable 13. NO/N 2 Injector Tube 14. Patient Gas Sample Line With Nafion Vyaire Infant Flow SiPAP System 12 14 13 11 10 9 8 7 6 Connections to various ventilators are unique to each manufacturer as well as their corresponding disposable circuits. Please refer to the INOmax DS IR Operation Manual for specific flow settings as these may change the flow going to the nasal adapter. For additional information, technical assistance, or a complete list of warnings, please refer to the INOmax DS IR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. For a general list of warnings, please see the attached WARNINGS card.

VYAIRE INFANT FLOW SiPAP SYSTEM MAKE THE CONNECTION Validated noninvasive compatibility with INOmax DS IR Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. Vyaire and Infant Flow SiPAP are 2018 copyrights of Vyaire Medical, Inc. Imagery used with permission. 2018 Mallinckrodt. US PRC/dvINT/0816/0014l(1) July 2018 www.inomax.com

MAKE THE CONNECTION Compatibility guide for validated noninvasive ventilation systems Warnings Caution: U.S. Federal and Canadian law restrict this device to sale by or on the order of a licensed medical practitioner. Outside the U.S.A. and Canada, check local laws for any restrictions that may apply.

Applications The INOmax DSIR Delivery Systems deliver INOMAX (nitric oxide) gas, for inhalation. The INOmax DSIR Delivery Systems must only be used in accordance with the indications, usage, contraindications, and warnings and precautions described in the INOMAX package inserts and labeling. The approved patient population is limited to neonates. Refer to the INOMAX Full Prescribing Information prior to use. Warnings Abrupt discontinuation of INOMAX can lead to worsening oxygenation and increasing pulmonary artery pressure (rebound pulmonary hypertension syndrome). To avoid abrupt discontinuation, use the INOblender or backup mode immediately to reinstate INOMAX therapy and refer to the INOMAX package insert. If the high NO 2 alarm activates, the delivery system should be assessed for proper setup while maintaining INOMAX delivery. Do not connect items that are not specified as part of the system. If an alarm occurs, safeguard the patient first before troubleshooting or repair procedures. Use only INOMAX, pharmaceutical grade NO/N 2. Warnings Contact your INOMAX representative to learn if your ventilator is compatible. For additional information, technical assistance, or a complete list of warnings, including warnings regarding use of validated ventilators, please refer to the INOmax DSIR Operation Manual, which can be found at www.inomax.com/nivvalidations, or contact Mallinckrodt at (877) 566-9466. Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. Other brands are trademarks of a Mallinckrodt company or their respective owners. 2018 Mallinckrodt. US PRC/dvINT/0816/0014(2) July 2018 www.inomax.com