fire resistant cables

Similar documents
High Performance LSZH Fire Resistant Cable

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

FIRE PERFORMANCE CABLE

Caledonian. FIREFLIX ire Resistant Coaxial Cables

ENHANCED FIRE PERFORMANCE CABLE

THE TRUE FIRE SURVIVAL CABLE

SPECIAL ELECTRICAL AND OPTICAL CABLES

FIRE RESISTANT CABLES FP300

Flame Retardant Overall Screened Instrumentation Cables (multicore)

FIRE RESISTANT CABLES FP400

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

The Quality Connection. Cable fire protection Flammability tests on ship and offshore cables

Cablosam Tapes for Fire-Resistant Cables

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

The Quality Connection. BETAflam Fire Resistant Safety Cables

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Havells Fire Survival Cables

Cable technology for highest safety requirements

FIRE RESISTANT CABLES

BS /1000V XLPE Insulation LSZH Sheath Cables

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Fire Resistant Cables

Traction Cable Radox 3 GKW

LSOH Flexible Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Introduction.

Caledonian Flame Retardant Coaxial Cables

Total Fire Solutions. Includes BS 8519 and the updated BS :

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

DNVGL-CP-0399 Edition March 2016

Caledonian fire Resistant signal & Data cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Catalogue Telecommunication Cables INTRODUCCIÓN

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Evolution of Cable Fire Safety Standards in Australia

STANDARDS INSTALLATION. Certificate No 077m

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Caledonian Fire resistant Coaxial Cables

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

DNVGL-CP-0401 Edition February 2016

PRODUCT CATALOGUE Norröna

TYPE APPROVAL CERTIFICATE

Telecommunication Cables

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

INTERNATIONAL STANDARD

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Single core cables with reduced wall thickness

Catalogue. Instrumentation & Control Cables

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Catalogue Power Cables

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

Photovoltaic Cables EN H1Z2Z2-K

INTERNATIONAL STANDARD

SAS Security and Alarm Safety Cables

INTERNATIONAL STANDARD

Firecel Safety Cables

OIL & GAS INDUSTRY OTHER INDUSTRIES

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Üntel is ready for CPR

Fire Safety Fire Resistant Building Components

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Multi-Core Fire Resistant Cable

Tratos Railway Cables

Lloyd s Register Type Approval System Test Specification Number 3

Compact Module. Category 6A FTP Cabling System 1.1

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

HELKAMA. Optical Fibre Cables

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

LV FIRE RESISTANT CABLES

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Transcription:

Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com

Special electrical and optical cables

2

INTRODUCTION Structured cabling solutions. Tecnikabel can provide a wide of signal transmission solutions for public and private areas. Whether building entrance or roof, data center, meeting rooms, auditoriums or conference rooms, we can build management and security system control rooms for each individual office or workstation. Fully integrated solutions employing copper cable and fiber to carry voice, video and data. Security & alarm cables Many current public and private buildings, such as offices, hospitals, airports, amusement parks, retail outlets, schools, stadiums and other such places, all have surveillance systems to track visitors and employees. The purpose of these systems is clear: to protect people, the facility and its assets. These cables are designed to make installation as simple as possible, and thereby save time and money. In the event of fire, it is critically important that the electrical detection, warning and alarm systems continue to operate - even in extreme conditions, such as fire and high heat. To ensure the safety and evacuation of personnel, the fire alarm system must not fail. Many Tecnikabel cables are specifically designed for use during severe fires. In such circumstances, fire resistance, low smoke emission and zero halogen emissions ensure there is no irremediable risk to either circuit or personnel. These cables are ideal for fire detection systems, emergency lighting, video surveillance and public address systems. The cables must ensure the following main features are complied with: high level of alarm circuit efficiency continuous operation in the event of fire Fire-resistant cables for fire detection and alarm systems and emergency lighting. British standard BS 5839-1: 2002 Fire detection and fire alarm systems for buildings. Part 1: Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises. We have two levels of cable resistance to fire. Most STANDARD applications employ TK FR 30 Standard cables (30 minutes at 830 C) or TK FR 120 Enhanced cables (120 minutes at 830 C). TK FR 30 and TK FR 120 are used in most applications: - Fire-resistant cables in fire detection and alarm systems for the construction industry. Voice alarm systems. - Emergency voice communication systems. - Emergency lighting of premises. - Fire-resistant cable control systems for life safety and fire-fighting applications - Category 1. PRODUCT LINES TraNsportation audiovideo Building Technology 3

TECNIKABEL is focused on constant product innovation to get competitive advantages with endless commitment to research and development. PRODUCTION Updated production Systems, stringent process procedures and expert operators reached the goal to carry out our production efficient and flexible. In 30 years of activity, we produced more than 26.000 different types of cables. FINAL INSPECTIONS At the end of every production process each cable is checked in its electrical and physical performances for a complete compliance to customer specifications. LABORATORY TESTS We submit our cables to the most severe tests, simulating critical applications. In addition to the tests required by current norms, we invest on new special equipment for additional mechanical and electrical testing, heading to a steady increase of standard performance of our cables. MATERIALS RESEARCH AND DEVELOPMENT Our thirty year experience took us to carry on research of new materials in order to improve performances, costs and fulfill the standards required by our customers. 4

QUALITY SYSTEM Since 1978, constant commitment to Quality has awarded Tecnikabel approval from American and European Authorities, complying with the most demanding international manufacturing and quality standards. ISO 9001:2008 9125 TEKA usted 5

6

SyMBOLS ENVIROnMENTAL PROPERTIES FLAME RETARDANT SINGLE WIRE (IEC 60332-1-2) direct burial FLAME RETARDANT BUNCHED WIRES (IEC 60332-3) antiballistic protection FIRE RESISTANCE (IEC 60331 EN50200 - BS6387 CWZ) chemical PROPERTIES REDUCED EMISSION OF FUMES AND TOXIC GASES (IEC 60754-1; EN 50267-2-1) MUD RESISTANCE SMOKE DENSITY (IEC 61034-1/2) MINERAL OIL RESISTANCE LOW ACIDITY AND CORROSIVITY OF EVOLVED GASES (IEC 60754-2) HYDROCARBONS RESISTANCE WEATHERING TEST RESISTANCE (OUTDOOR) mechanical PROPERTIES INDOOR MECHANICAL RESISTANCE WATER RESISTANCE REDUCED BENDING RADIUS RODENT RESISTANCE WORK AT LOW TEMPERATURE hazardous area flexible installation fully dielectric 7

8

fire performances 9

IEC 60332-1 / EN 50265 / BS 4066: Fire propagation on a vertical single cable. The single cable is mounted vertically and flamed with a Bunsen burner. The flame must extinguish itself, at least 50 mm below the upper fixing clamp. Temperature of burner, duration and angle of flame application, are described in the reference standards. IEC 60332-3 / EN 50266 : Fire propagation on a vertical cables bundle. A certain number of cable samples are fixed on a 3,5m long ladder, and flamed with an appropriate burner. The samples number, the duration of flame application, and the power/temperature of burner are described in the reference standards. After flame application, the visible area of fire damage must not exceed 2.5 m in height from the bottom of the burner. The volume of tested material define a differentiation in categories: A/FR Part 3-21 7 l/m A Part 3-22 7 l/m B Part 3-23 3,5 l/m C Part 3-24 1,5 l/m D Part 3-25 0,5 l/m IEC 60331 / EN 50200 : Fire test resistance. A sample of cable is horizontally applied supported by metal rings, or in U shape fixed on a fireproof wall. Through using a gas burner the cable is maintained in flame contact for a certain time. The test and the temperature of burner are described in the reference standards. In U shape test, the fireproof wall is hit every five minutes by a mechanical shock, to simulate a potential collapse during the fire. The time of fire application, and the temperature of flame are described in the reference standards (typical 750 C or 830 C). During the test a current for continuity checking is passed through all conductors of the cable and the voltage must be maintained during the test duration. 10

BS 6387 Category C-W-Z. The test equipment is different from the previous test. In this case, in addition to the mechanical shock, a jet of water to simulate a sprinkler fire extinguishing system is also applied. IEC 61034-1/2 / EN 50268-1/2 Measurement of smoke density of cables burning under defined conditions. A few samples of cable are burnt in a cubic (3x3x3m) chamber using a flammable liquid. The light transmittance of the resulting smoke is measured using an optical light detector. The test duration is about 40 minutes, depending by the quantity and composition of the liquid fuel. At the end of the test the light transmittance of the smoke must be 60% minimum. IEC 60754-1 / EN 50267-2-1 Test on gases evolved during combustion of materials from cables - Determination of the halogen acid gas content. This standard covers the general aspects of potential hazard caused from corrosiveness of smoke and combustion gases. A small quantity of non-metallic material is heated in a tube, the resulting gases are tested for their halogen content. The flame temperature is 800 C ± 10 C, with a test duration of 40 ± 5 min in total. The halogen content of non-metallic materials must be less than 0.5% or 5 mg/g. IEC 60754-2 / EN 50267-2-2 Test on gases evolved during combustion of materials from cables - Determination of acidity (by ph measurement) and conductivity. A small quantity of non-metallic material is burnt in a furnace, the ph and conductivity combustion gases dissolved in water are measured. The minimum ph value of the washing water must 4.3, and the maximum conductivity must be 10 μs/mm. 11

NOTES 12

FIRE RESISTANT CABLES class ph30 tk-fr30 standard 13

Multicore Cable TK-FR30 Standard CABLE SPECIFICATIONS Conductor Solid Plain annealed copper (0.5 0.75-1-1.5-2.5 mm 2 ) Stranded Plain annealed copper (for 4 mm 2 ) Insulation Core identification Drain wire Fire Resistant Silicone Brown-Blue ( 2 core) Brown-Black-Grey (3 core) Blue-Brown-Black-Grey (4 core) Solid Tinned copper ø 0.8mm (0.5 mm 2 ) Shield Sheath Colour Polyester backed co polymer Aluminum Foil. (Aluminum side in contact with Drain wire) Low Smoke HFFR Thermoplastic material Red or White TECHNICAL DATA Operating Voltage 300/500 V Test Voltage 2000 V AC x 1 Temperature rating -40 C + 90 C Minimum bending radius 6 x ø FIRE PERFORMANCE Resistance to fire EN 50200:2006 PH30 Resistance to fire required to maintain circuit integrity under fire conditions BS 6387:2013 Category CWZ Flame propagation EN 60332-1-2:2004 Acid gas emission EN 50267-2-1 (<0.5% HCI) Low smoke density EN 61034-2:2005 + A1:2013 (>60%) 14

Multicore Cable TK-FR30 Standard MAIN FEATURES Cable Description Nominal Diameter [mm] Conductor Resistance (@ 20 C max.) Cable Weight [Kg/km] TK code (p/n) 2 x 0.5 6.50 36 68.0 430TKFR3002 2 x 0.75 6.70 24.5 72.0 435TKFR3002 2 x 1.0 7.15 18.1 82.0 440TKFR3002 2 x 1.5 7.50 12.1 86.0 445TKFR3002 2 x 2.5 8.80 7.41 119.0 455TKFR3002 2 x 4.0 10.90 4.61 208.0 465TKFR3002 3 x 0.5 7.30 36 77.5 430TKFR3003 3 x 0.75 7.45 24.5 81.5 435TKFR3003 3 x 1.0 7.65 18.1 91.5 440TKFR3003 3 x 1.5 8.45 12.1 117.5 445TKFR3003 3 x 2.5 9.10 7.41 173.5 455TKFR3003 3 x 4.0 12.40 4.61 248.5 465TKFR3003 4 x 0.5 7.50 36 82.5 430TKFR3004 4 x 0.75 7.70 24.5 87.5 435TKFR3004 4 x 1.0 7.90 18.1 96.0 440TKFR3004 4 x 1.5 9.20 12.1 145.0 445TKFR3004 4 x 2.5 11.00 7.41 200.0 455TKFR3004 4 x 4.0 13.64 4.61 307.0 465TKFR3004 15

NOTES 16

FIRE RESISTANT CABLES CLASS PH120 tk-fr120 ENHANCED 17

Multicore Cable TK-FR120 Enhanced CABLE SPECIFICATIONS Conductor Solid Plain annealed copper (0.5-0.75-1.0-1.5-2.5 mm 2 ) Stranded Plain annealed copper (4.0 mm 2 ) Insulation Core identification Drain wire Fire Resistant Ceramic Silicone Brown-Blue ( 2 core) Brown-Black-Grey (3 core) Blue-Brown-Black-Grey (4 core) Solid Tinned copper ø 0.8mm (0.5 mm 2 ) Shield Sheath Colour Polyester backed co polymer Aluminum Foil. (Aluminum side in contact with Drain wire) Low Smoke HFFR Thermoplastic material Red or White TECHNICAL DATA Operating Voltage 300/500 V Test Voltage 2000 V AC x 1 Temperature rating -40 C + 90 C Minimum bending radius 6 x ø FIRE PERFORMANCE Resistance to fire EN 50200:2006 PH120 EN 50200:2006 Annex E 30 min Resistance to fire required to maintain circuit integrity under fire conditions BS 6387:2013 Category CWZ Flame propagation EN 60332-1-2:2004 Acid gas emission EN 50267-2-1 (<0.5% HCI) Low smoke density EN 61034-2:2005 + A1:2013 (>60%) 18

Multicore Cable TK-FR120 Enhanced MAIN FEATURES Cable Description Nominal Diameter [mm] Conductor Resistance (@ 20 C max.) Cable Weight [Kg/km] TK code (p/n) 2 x 0.5 6.70 36 69.0 430TKFR1202 2 x 0.75 6.90 24.5 73.0 435TKFR1202 2 x 1.0 7.25 18.1 83.0 440TKFR1202 2 x 1.5 7.60 12.1 87.0 445TKFR1202 2 x 2.5 8.90 7.41 121.0 455TKFR1202 2 x 4.0 11.00 4.61 209.0 465TKFR1202 3 x 0.5 7.40 36 78.0 430TKFR1203 3 x 0.75 7.55 24.5 82.0 435TKFR1203 3 x 1.0 7.75 18.1 92.0 440TKFR1203 3 x 1.5 8.55 12.1 118.0 445TKFR1203 3 x 2.5 9.20 7.41 174.0 455TKFR1203 3 x 4.0 12.50 4.61 249.0 465TKFR1203 4 x 0.5 7.60 36 83.0 430TKFR1204 4 x 0.75 7.80 24.5 88.0 435TKFR1204 4 x 1.0 8.00 18.1 97.0 440TKFR1204 4 x 1.5 9.40 12.1 147.0 445TKFR1204 4 x 2.5 11.10 7.41 202.0 455TKFR1204 4 x 4.0 13.74 4.61 309.0 465TKFR1204 19

FIRE AND FLAME BEHAVIOUR TESTS It is essential to stay within the fire behavior and flame-fire-retardant limits set by the strictest reference standards and our own internal QA. Four tests are carried out to assess specific properties under fire conditions: Test for vertical flame propagation for a single insulated wire or cable. - According to UL standards (Cable Flame, VW1, Horizontal Flame Test) - CSA (FT1, FT2) - CEI EN or IEC 60332-1-2 / 60332-1-3 /60332-2-2 Test for vertical flame spread of vertically -mounted bunched wires or cables - According to UL standards (Vertical Tray Flame Test, UL 1685) - CEI EN or IEC 60332-3 series Tests for electric cables under fire conditions - Circuit integrity - According to CEI EN 50200 and CEI IEC 60331 series - According to British Standards BS 6387 type CWZ Measurement of smoke density of cables burning under defined conditions - According to IEC 61034-1 and IEC 61034-2 20

NOTES 21

NOTES 22

NOTES 23

NOTES 24

CONTACT HEADQUARTER VOLPIANO via Brandizzo, 243 10088 Volpiano (Turin) Italy Tel. +39 011 9951997 Fax +39 011 9953062 www.tecnikabel.com PRODUCTION PLANTS VOLPIANO via Brandizzo, 243 10088 Volpiano (Turin) Italy ALMESE via Rivera, 100 10040 Almese (Turin) Italy COMMERCIAL OFFICES TECNIKABEL ROME via Casali delle Cornacchiole, 154 00178 ROMA - ITALY TECNIKABEL M.E. JLT 3008 Mazaya Business Avenue Jumeirah Lake Towers DUBAI, UAE AGENT / DEALER TECNIKABEL ASIA PTE LTD 16 Tuas South Street 2 SINGAPORE 637786 TK DEUTSCHLAND GmbH Herdewerg 8 83623 Steingau, GERMANY Special electrical and optical cables www.tecnikabel.com