TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Similar documents
THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Sensor Interface Module Installation/Operation Instructions

TTSIM-1 Sensor Interface Module

Industrial Strength Leak Detection

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

aquilar - leak detection solutions

C910 Series. Single-point heat-tracing control system

ACCS-30. Multipoint commercial heat-tracing control system

C A Heating Cable Gland Kit

RayClic Connection System

aquilar - leak detection solutions

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

Industrial Strength Leak Detection

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

C Electrical Connection Kit

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

Installation, Operation and Maintenance Manual

Fuel Leak Detection Find Leaks Before They Find You

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

QuickStat-TC Installation & Operation Manual

DESCRIPTION. 42 mm. 125 mm

TraceTek FIND LEAKS BEFORE THEY FIND YOU

Gardian W51. Approvals

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

TraceTek Leak Detection

TT7000-HUV TraceTek Sensing Cable for Strong Mineral Acids

Supervisor Standard Edition

TraceTek TT1000 Modular Sensing Cable

Raychem Heating System

Cable Actuated Sensor Industrial User Scalable 4 20mA

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

4100U City and Relay Cards Installation Instructions

Cable Actuated Sensor Industrial User Scalable VDC Output

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Model 4001 Series Single Channel Controller

VA301C CONTROLLER WITH BACnet OPTION

HTC-915-CONT. Heat-Trace Control system

INSTALLATION INSTRUCTIONS

Remote Relay Module (RRM)

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

PT9420 (Extended Range)

MBUV-100D, MBUVS-100D MBIR-100D, MBFR-100D DIN RAIL MOUNT FLAMEWORX MODULES

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

Beacon 800 Gas Monitor Operator s Manual

/9308 External Battery Chargers Installation Instructions

PolySwitch TS600 Overcurrent Protection Devices

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

JDDT1 - Single Stage Digital Thermostat

PT9150 (Extended Range)

SAFETY INFORMATION AND WARNINGS

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Duct and Rough Service Carbon Monoxide Sensor

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

TE Connectivity's AMP NETCONNECT Cable Management

Ultrasonic Reflective Sensor

HAI Omni-Bus Network Installation. 5. Typical Application

RC-2000 Thermostat Installation Instructions

UNC100 Integra Manual

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

OPERATION MANUAL Model 8011 & mA

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Beacon 410A Gas Monitor Operator s Manual

Operating Instructions. For. Alarm Control Module. Model SSR 500

Power Supply Display Module PSDM. Installation and Operation Manual

Operations Manual. Motion Detector Module Model ZS10

Static Pressure Control

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

SEC 2000 Millenium Infrared Gas Detector

CAUTION & SYMBOL DEFINITIONS:

Beacon 110 Gas Monitor Operator s Manual

AT-G-SENSE Gas Sensing System

INSTALLATION INSTRUCTIONS

NGC-40 Advanced Heat-Tracing Control System

Ultrasonic Reflective Sensor

OPERATION MANUAL MODEL & ACCELEROMETER

Protocol Station Remote Alarm

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

Radiant Thermostat 519

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Analog Room Pressure Monitor RPC Series

Oxygen (O2) Single-Point Gas Detection System

Mark 25 Ultrapure Water Conductivity Analyzer

Instruction Manual August sitrans CU 02

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Transcription:

TTSIM-1A TraceTek Sensor Interface Module with Relay Installation Items (not supplied) General Information Installation/Operation Instructions Please read these instructions and keep them in a safe place. These instructions must be followed carefully to ensure proper operation. The TTSIM-1A has been designed for use with TraceTek sensing cables, point sensors and normally open, dry contact devices (float switch, pressure or vacuum switch, optical probe with adapter, limit switch, etc.). Up to 150 m (500 ft) of sensor cable can be monitored by the TTSIM-1A. Contact factory for information regarding longer monitoring distance. The TTSIM-1A is designed for installation in ordinary (non-hazardous) areas. The TTSIM-1A has five small LED s to indicate power, status and communications activity, as well as a relay with SPDT contacts. The TTSIM-1A can be used as a stand-alone leak detection alarm, or connected to a host system (TraceTek TTDM-128, computer, or control automation system) via simple, shielded twisted pair RS-485 serial communication wiring. 35 mm DIN rail mounting strip (for wall mounts or interior of large control cabinets) and attachment hardware. TT-RS485 power and telemetry cable. Optional TTSIM-ENC-4X-OUTDOORS environmental enclosure for outdoor or corrosive environments, or TTSIM-ENC-4X-INDOORS enclosure with clear cover for indoor, non-corrosive environments. Tools Required Small flat blade screwdriver Small needle nose pliers Tools to mount DIN rail or enclosure Storage Keep the TTSIM-1A modules in a dry place prior to installation. Avoid damage to components. Product Information TTSIM-1A TTSIM-1A-230 Relay contacts Installation categories Storage temperature Operating temperature Enclosure 22 to 26 Vac, 50/60 Hz, 3 W 92 to 132 Vac, 50/60 Hz, 3 W 216 to 253 Vac, 50/60 Hz, 3 W Form C (SPDT), 250 Vac/30 Vdc at 2 Amps maximum Overvoltage Category II Pollution Degree 2 18 C to 60 C (0 F to 140 F) 0 C to 50 C (32 F to 122 F) NEMA 1; IP00 (NEMA 4X / IP 56 with optional enclosure) Approvals Listed 76LJ Signal System Unit TYPE NM Additional Items An agency-approved zener barrier must be used where sensing cable connected to the TTSIM-1A will be located in Class1 Div 1 (Zone 0 or 1 in Europe) Hazardous Locations.

2 Installing the TTSIM-1A Note: To avoid damage to the TTSIM-1A, store the unit in its packaging until ready to install. Selecting the mounting position Choose a location where the module will be protected from the elements, temperature extremes or heavy vibration. The TTSIM-1A is designed to be snapped onto standard 35 mm DIN rail. Existing electrical or instrumentation cabinets with spare rail space make good mounting locations. It is also possible to install a small section of DIN rail directly on a wall or cabinet surface and mount the TTSIM-1A in any location as long as it does not create a tripping hazard or expose the TTSIM-1A to impact damage. The TTSIM-1A should be mounted within 1200 m (4000 ft) wire run from the controlling TTDM-128 or control system host. Contact the factory for methods to increase the wire run distance beyond 1200 m. Important: The TTSIM-1A is an electronic unit. Take the following precautions to avoid damage to electronic components: Handle with care and avoid mechanical shock and impact. Keep dry. Avoid exposure to static electricity by touching a nearby piece of grounded equipment or water pipe prior to handling the TTSIM-1A. Avoid contact with metal filings, grease, pipe dope and other contaminants. Mounting the TTSIM-1A module (without NEMA 4X Enclosure-- Figure 1) Secure a sufficient length of DIN rail to the desired mounting surface, or locate an existing DIN rail with sufficient space to install the TTSIM-1A. Remove the TTSIM-1A from it s packaging and snap onto the DIN rail with the release tab towards the bottom. Figure 1. DIN rail mount Release tab 35 mm DIN rail Mounting the TTSIM-1A module in the optional NEMA 4X Enclosure--Figure 2 Plan conduit alignment and drill holes as necessary. A typical outdoor or harsh environment installation will require three holes in the TTSIM-ENC: one for inbound power and telemetry, one for outbound power and telemetry and one for the sensor cable leader. See Figure 2. Secure the TTSIM-ENC to any convenient vertical surface using the four corner mounting holes and hardware suitable for the selected surface. Rough-in conduit as required and pull the cables for power and telemetry. Leave approximately 20 cm (8 in) for connection to TTSIM terminals. Pull in the sensor circuit leader cable. In order to provide maximum electrostatic discharge protection, and to be CE compliant, the DIN rail must be grounded. Note: Rough-in and final connections do not have to be completed at the same time, however make sure to replace the cover and tighten the cover screws if the enclosure will be left in a partially installed condition overnight or longer. Figure 2. NEMA 4X enclosure

3 Supply Options The TTSIM-1A has several power supply options available. Depending on the version being installed and local regulations, the wiring requirements may vary. In all cases, be sure that each TTSIM-1A receives supply voltage from one and only one source. Connections for and Telemetry TTSIM-1A communicates all alarm and status messages via RS-485 shielded twisted pair telemetry. Two of the four conductors in the power/telemetry cable are used for telemetry and the other two wires may be used to provide the supply voltage. Alternatively, separate wiring may be used for the supply voltage, as shown in Figure 3. For all TTSIM-1A modules except the last one, there will be an incoming cable (from the TTDM-128 or other host system) and an outgoing cable (to the next TTSIM-1A). Strip a sufficient amount of the jacket insulation and shielding to expose about 2.5 cm (1 in) of the four wires. Strip the primary wires to expose approximately 6 mm (1/4 in) of conductor and make the following connections: (see Figure 3) Terminal Color Item 13 Shield Drain Wire 14 Black RS-485 ( ) 15 Red RS-485 (+) 16 Shield Drain Wire 17 Black RS-485 ( ) 18 Red RS-485 (+) [Shielded twisted pair from TTDM-128, Host, or previous TTSIM] [Shielded twisted pair to next TTSIM] 21 Green Supply From source or 22 White Supply previous TTSIM* 23 [Green] Supply 24 [White] Supply [To next TTSIM] Figure 3. and Telemetry Connections * supply voltage must be within range specified on TTSIM-1A label. Items in square brackets [ ] are optional. When using TraceTek TT- RS485 power and telemetry cable for power supply distribution, follow the color codes indicated in brackets. Connections for The software programmable TTSIM-1A relay contacts may be used for local or remote annunciation, to control a valve or other device, or for connection to a control automation system contact input. The relay can be programmed to alarm on leak only or on either leak or sensor fault. The relay can also be programmed to be ON (coil energized) or OFF (coil de-energized) to signal an alarm (see table below). The relay can be programmed using either a TTDM-128 or a PC running TT-SUPERVISOR software. 1 2 3 4 10 11 12 Programmed Alarm State Alarm Condition Status at Terminals 10-11 11-12 On (default) No alarms closed open Alarm open closed Loss of power closed open Off No alarms open closed Alarm closed open Loss of power closed open Figure 4. Connections (shown in power off condition)

4 Place the End of Line in the correct position If the TTSIM-1A will be connected to a host for communication, it is necessary to set the End of Line in the correct position as follows: On the last TTSIM in the circuit, place the jumper as shown in Figure 5a. On all other TTSIM s in the circuit, place the jumper as shown in Figure 5b. EOL 18 21 EOL 18 21 Figure 5a. End of Line for last TTSIM Figure 5b. End of Line for all other TTSIM s Leader Cable Connections for Sensor The TTSIM-1A can be used with any of the TraceTek family of sensors including: TT1000, TT3000, TT5000 and TT5001 cables, as well as float switches and point probes. Connect the TraceTek leader cable to the TTSIM as shown in Figure 6. Pow Servic Le Terminal Color Item 1 Red Red / Green Loop 2 Green 3 Yellow Yellow / Black Loop 4 Black Red Green Yellow Black Figure 6. Sensing Cable Connections

5 Operating Instructions Assignment If the TTSIM-1A will be used in a TraceTek network, each module in a TraceTek network must have a unique address in the range 001 to 127. All TTSIM-1A units are shipped from the factory with their network address pre-set to a value above the range of valid addresses, in order to prevent communication conflicts during system startup and configuration. Each TTSIM must therefore be configured to a unique address before it can communicate with the TTDM-128 or other host. To set the TTSIM-1A network addresses, repeat the following procedure for each TTSIM-1A. Perform the complete procedure one module at a time: Place the TTSIM-1A configuration jumper in the position, as shown in Figure 7a. Using the TTDM-128 or host system, assign the new TTSIM-1A address (refer to the TTDM-128 User Manual or the TraceTek System Integration Manual for instructions). Place the configuration jumper in the normal operating position, as shown in Figure 7b, or remove it completely (the jumper is not required in normal operation). 1 2 3 4 10 11 12 1 2 3 4 10 11 12 4 J6 8 4 J6 8 Figure 7a. Configuration in Configuration Position Figure 7b. Configuration set for Normal Operation

6 Maintenance and Troubleshooting No user maintenance is required! There are no user adjustments or calibrations that can be performed in the field. Each TTSIM-1A is tested and calibrated at the factory. An operating TTSIM-1A runs a continuous self check routine and reports any discrepancies to the TTDM-128 or host computer. If the TTSIM-1A or the network wiring fails in such a way that the TTSIM-1A cannot communicate with the host, then the host reports the failure as a communications failure. Status Indicators There are 5 LED s on the TTSIM-1A circuit board to indicate: power, communications (inbound and outbound), sensor status (leak detected and trouble). See Figure 9. The green LED will be ON and will blink once every 5 seconds when the TTSIM-1A is powered and fuctioning correctly. Table 1 lists various sensor status conditions and possible corrective actions. Table 2 lists communication status conditions (applicable when the TTSIM-1A is used in a network system). RX (Yellow) TX (Yellow) (Red) (Yellow) (Green) Figure 9. TTSIM-1A LED locations Table 1. TTSIM-1A LED operational status indications LEAK SERVICE INDICATION FLASH ON FLASH detected. Check sensor for leak or spill. alarm has been reset by operator but the leak condition still exists The sensor needs servicing. Check sensor and leadwires/jumpers for continuity or contamination. Table 2. TTSIM-1A communication status indications (only active if connected to a network) TX RX INDICATION FLASH FLASH Unit is communicating normally with TTDM-128 or host. OFF FLASH Unit is receiving communication from TTDM-128 or host, but is not responding. OFF ON RS-485 communication wires are reversed OFF OFF Unit is not communicating with TTDM-128 or host. Tyco Thermal Controls Worldwide Headquarters 300 Constitution Drive Menlo Park, CA 94025-1164 USA Tel: (650) 216-1526 Fax: (650) 474-7513 E-mail: info@tracetek.com www.tracetek.com Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranty as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. Tyco, TraceTek and the TraceTek logo are trademarks of Tyco Thermal Controls LLC or its affiliates. 2003 Tyco Thermal Controls LLC H57338 08/03