NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Similar documents
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

Installation Instructions

Door Release Power Supply

SDR-WEXT Wired Siren Installation Guide

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

Installation Manual. Odyssey X Series INS627-2

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

USER MANUAL CEF AP28 CONTROL PANEL

SECURIT 700L PLUS ENGINEERING MANUAL

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

External Wireless Sounder

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

NRB100. Installation and Programming Manual INSTALLATION NRB100 AND PROGRAMMING MANUAL

DOLKPL1KB DOLKPS1KB DOLKSF1KB

Operating Guide. English Version 3.3

User Operation Guide Document: VI49.2

Polycarbonate External Sounder & Strobe Unit

KM300 Carbon Monoxide Detection System Installation Manual

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Model 3.6m. User Manual Original instructions

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

ELECTRONIC SOUNDER STROBE Model : AVD-C407

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Keep this guide in a safe place. Contents

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

External Wireless Sounder

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

D-Tect 2 GJD300 Quad PIR Movement Detector

INSTRUCTION & SERVICE MANUAL

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

AXS Strikemaster Engineering Manual

Control Panel Engineering and Commissioning Instructions

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

2-ZONE EASYFIT INTRUDER ALARM

The Remote alarm Panel, TYPE RAPv2

SA SIREN AMPLIFIER

5000 SERIES 8 ZONE INSTRUCTION MANUAL

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

BX444-Mc Gas Detector

Intruder - Fire - Water Combined Alarm

CONTENTS NBM-06 Bell (6") Page 1

C2 Compact Range Installation & Programming Manual

External Sounder and Strobe Units

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION & SERVICE MANUAL

TECHNICAL DATA OBSOLETE

EXTINGUISHING AGENT RELEASE MODULE

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

HARDWIRED CONTROL PANELS

Intelligent Security & Fire Ltd

Intruder alarm system Operating Instructions

External Sounder and Strobe Units

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Electronic Fire and Security Systems: Intruder and Hold-Up Alarm Systems Installation (SCQF level 6)

Installation & Operating Instructions

2-ZONE EASYFIT INTRUDER ALARM

INSTALLATION GUIDE. For products. Gardtec 370 & 581

636 and 646 Keypads. User s Manual

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

installation & operation manual

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

INSTALLATION INSTRUCTIONS

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

USER GUIDE HARDWIRED CONTROL PANELS

SPECTRA 1727 USER S GUIDE

Installation Manual RINS1211-4

FEC400 Series. Installation Manual

Deaf & Hearing Impaired RadioLINK Alarm System

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Excellence in Level Measurement

RE-PR3-E-27 3-Phase Panel Mount 27kW

ADE Gen4. Speech Dialler Engineering Information. Description. Features

LS800S Intruder Alarm System. Engineering Manual

SECURIT 703 USER MANUAL

C106 Coded Access Keypad

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Conventional Fire Detection

Control Panel User Guide

DI601AM Outdoor PIR/AM Detector Installation Sheet

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

HARDWIRED CONTROL PANELS

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Disabled Persons Toilet Alarm Kit

Instructions for the fan motor control system with integrated wiring terminals SILVER C

SECURIT 700L USER MANUAL

Transcription:

VI64 Version:1.1 Issued 06/12/2007

INTRODUCTION Ventcroft s external sounder/strobes offer an unsurpassed range of models which provide for virtually any installation need. Most models feature a robust housing to conform to BS4737 PD6662 & BSEN50131 and have a loud Piezo sounder, high intensity strobe, twin status LED s, multiple tamper, re-chargeable battery, and a dual safe cut-off timer incorporating an engineer sounder hold off. The nt model provides negative trigger for the sounder and strobe, and negative tamper return, and provides the most competitive option. uk models provide for the same as nt but the tamper return is switched via relay contacts, designed to provide a higher level of security monitoring. Important Note: The use of stranded steel cable or aluminium copper coated stranded cable or cable which has a resistance value of more than 120 Ohms per kilometre will invalidate the warranty of the sounder. WIRING CONNECTIONS + These terminals provide the inputs to SUPPLY the SAB/SCB circuitry with 12V constant Hold off un-switched supply. The positive terminal is also used to provide the positive supply for the - - strobe circuitry. The negative terminal commons as part of the tamper return. If either the positive or negative supply is removed the sounder will cease to be held off and begin to sound. On nt models if negative hold off is removed the tamper return signal will be removed. On uk models if either positive or negative hold off is removed the tamper return signal will be removed. TRG - STB - RTN - Provides the input for the negative applied signal used by the control panel to TRIGGER the sounder i.e. an intruder activation. In the UK the signal is normally a switched negative to activate the sounder. Provides the input from the control panel for the negative applied signal, which is required to activate the xenon STROBE. This input is independent of the sounder input, normally used by the control panel to allow the strobe to continue flashing after the sounder has stopped. In the UK this signal is normally negative applied. During operation the xenon tube utilises a high voltage across its terminals to create the intense flash. This voltage can exceed 250V DC and the strobe tube should never be touched. A high voltage can remain across the strobe for some time after the supply has been removed. NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK. Provides the switched negative RETURN signal, required by the control panel indicating that the tamper switch is closed, when closed the signal is a constant negative. nt models provide this signal directly through the micro-switch, which is also removed when Hold-off negative is disconnected. uk models provide this signal switched via a relay, which is removed with disconnection of either Hold-off positive or negative. + Sounder output, these terminals are high voltage and are only suitable for driving the Piezo Sounder sounder provided. NEVER connect any other wires to these terminals, or touch these - terminals if the sounder is activated as there is a risk of electric shock. + Provides the terminals to connect the backup rechargeable battery required to Battery activate the SAB/SCB circuit if the "Hold-Off" Voltage is removed. To activate the battery - the battery jumper must be connected to complete the installation. Rechargeable batteries generally require replacing every three to five years to ensure correct SAB/SCB function. STB + If this option is fitted a positive supply must be applied either by connecting to strobe positive in the control panel or by linking STB+ to hold off + in the sounder. Pg 2

INSTALLATION GUIDE Operation Step 1. Decide and select which features and modes are required, i.e., LED s either alternating or constant, sounder either high-low or sweep and mode either SAB or SCB. A detailed description of the options can be found on pages 4 and 5. 2. Drill all holes required for mounting the sounder. Insert suitable rawl plugs to provide a strong and secure installation. 3. Move the white Timer jumper link to the T position. Now move the red Battery jumper link to the on position, the sounder will now start and continue for 5 seconds, then silence. Once the sounder has silenced, move the white Timer jumper link back to the A position. The sounder will remain silenced allowing all work to be carried out without unnecessary noise. This operation also tests the action of the dual fail-safe timer. 4. Fix the back-plate assembly to the wall with suitable screws. Connect the wires necessary to the bell box, make a note of the colour and terminals for later. Do not connect to the control panel yet. 5. Fit the sounder front cover, ensure the micro-switch is operating correctly. As the Cover fixing bolt(s) is tightened, the micro-switch should be heard to click as the screw approaches the end of its travel. 6. Now wire to the control panel, the wire colours recorded in step 4 should aid in this process. A list of well known control panel connection diagrams can be found on pages 6 and 7. 7. It should now be possible to see the Amber and Red LED s in the bottom lens, they will either be flashing or constantly illuminated depending on the jumper link selection made earlier. Commissioning & Testing Operation Step 1. Unscrew the cover fixing bolt(s), the sounder should start and the red LED should extinguish. Ensure the sounder runs beyond the 5 seconds test this is to double check that the timer is not in T test position. Tighten the bolt(s) once again. The sounder should stop and the red LED should illuminate again. Some control panels may need resetting at this stage. 2. From the control panel, perform sounder and strobe tests. Most control panels have test modes detailed in their respective manuals. This test should be performed regularly to ensure correct and proper long term operation of the external sounder. Pg 3

SPECIAL FEATURES Selectable Options Timer Select - White Jumper - (Included on all Models) A Provides standard 15 minute cut-off timer. (Factory Default) T Provides a 5 second sounder and timer engineer test. During installation and service this feature can be used to quickly silence the sounder at anytime. Battery - Red Jumper - (Included on all Models) OFF ON In this position the battery is isolated, it can be used to quieten the sounder when no Hold- Off Voltage is present. (Factory Default) When in this position, the battery is connected in circuit, enabling the SAB/SCB Sounder circuit and battery charging circuit when Hold-Off Voltage is present. Sounder Mode - Blue Jumper (Inside Case) Some models may include a cut link to enable choice of sounder mode. SAB SCB This is the standard sounder operation mode. It stands for Self Activated Bell. When the sounder is activated, its current is drawn from the control panel, except if the Hold-Off Voltage is removed or is missing. It provides maximum sounder volume. (Factory Default) If this selectable feature is excluded, the sounder will be set to SAB only In this mode when the sounder is activated the current is provided from the on-board rechargeable battery, not from the control panel. This feature is ideal for secondary sounders where the control panel or power supply does not have sufficient current load capacity. LED Selector - Black Jumper (Inside case) (Not available on all models) ALT When selected the Status LED's alternate from side to side. (Factory Default) CONST When selected the red and amber Status LED's are illuminated constantly and do not flash Siren - Yellow Jumper (Inside case) (Some models have a cut link to choose Siren Sound options) Sweep Hi-Lo When the sounder is activated it sounds like an American fire engine. It provides a higher pitch sound very effective over shorter distances. It is perceived to have a higher volume over small distances. (Factory Default) When the sounder is activated it will sound like a British police car. It provides sound that travels well and is distinguished well from background noise. High Bright LED Status Indicators Provides a visual indication of the Sounder status and health, ideal for end user comfort, intruder deterrent and engineer feedback. These LED s display at all times regardless of the set or un-set condition of the Control Panel (Included on all Models) Amber LED Red LED Pg 4 Illuminates when the Hold-Off Voltage is connected correctly. Illuminates only when the tamper switches are closed correctly and the Hold-Off Voltage is present.

Engineer Sounder Hold off Facility This feature allows an engineer to work on the Sounder with as little noise as possible. To limit the alarm ring time to a maximum of 5 seconds, simply move the white jumper timer link to the "T" test position. In this position whenever the sounder is requested to ring, it will do so for a maximum of 5 seconds. During installation, this can be very useful. With this feature it is possible to completely install a Sounder without actually completing the wiring to the control panel, ideal for a first fix installation. Simply fit the timer link to "T" test position and turn the battery on by moving the battery link to "ON". The sounder will be activated for 5 seconds then stop. Move the timer link back to the 'A' position and leave the battery on, fit the Sounder making a note of the wire colours used. The completion of the control panel wiring to the Sounder may now be at the installer's discretion. Should the control panel not be wired for a number of days, the on-board battery may flatten and will take 24 hours to recharge. This is quite normal. Connecting Two Sounders is Simple The Easy Way, Bringing Both Sounder Cables Back to the Control Panel Simply run both sounder cables direct to the control panel. Connect both sounders in parallel to the control panel connections i.e. two wires in each terminal: reference diagrams above. Now from sounder ONE (Primary Sounder) remove the RTN wire from its terminal in the control panel and from sounder TWO remove the Hold OFF (-) from its terminal in the control panel. Finally now join the two loose wires together with a piece of connector strip. This completes the wire connections at the panel for the sounder. Pg 5

Connection Diagram Examples Please Note, whilst Ventcroft endeavour to provide exact reference connection diagrams, it is beyond the scope of these instructions to guarantee the exact terminal descriptions and positions as third party manufactures may make modifications without notice. Pg 6

Connection Diagram Examples Technical Help Line: 01928 581098 Please Note: Ventcroft Ltd. are pleased to include reference diagrams, but all information is given in good faith and without warranty. Trademarks are the property of the respective owners and all Trademarks are acknowledged. Pg 7

SPECIFICATIONS Housing The Cover, backplate and lens materials vary depending on model purchased please check sounder specific specifications Screen Printing Available Up to 3 Colours - including Metallic Tamper Actuation Screw / Back Return - nt Negative Via Tamper Switch - uk Negative Via Relay Contacts Hold-Off Working Voltage 13.2 V Nominal (10V - 15V) SAB Auto Activation 7V Nominal (5V - 8V) Standby Current Alternating LED s 42.3 ma Constant LED s 53.3 ma Xenon Strobe Working Voltage 13.2 V Nominal (10V 15V ) Current 130 ma Nominal (150 ma Max.) Tube 2W Linear Xenon Flash Rate 1 Hz Nominal (50-120 per min.) Trigger Negative Applied Sounder Current Single Piezo 125 ma (160mA Max.) Twin Piezo 265 ma (300 ma Max.) Sound Pressure Single Piezo 114 dba @ 1M (116 dba Peak@ 1M) Twin Piezo 117 dba @ 1M (119 dba Peak@ 1M) Trigger Negative Applied / Positive Removed Cut-Off Timer A 15 minutes Nominal T 5 Seconds Nominal Battery Voltage 6V Charge Current Trickle 5.5 ma Nominal From Discharged 13.8 ma Max. Charge Time Type 24 Hours NimH Product Coating Type HPA, High Performance Acrylic Military Approval MIL-1-46058C Temperature Storage -25 C to +60 C Working Electronics -25 C to +55 C Battery Nom. +15 C; Min. 0 C, Max.+65 C Standards European CE Safety Designed to Conform to European Union Low Voltage Directive (LVD) 73/23/EEC (amended by 89/336/EEC). EMC Designed to Conform European Union Electro-Magnetic Compatibility (EMC) Directive 89/336/EEC (amended by 92/31/EEC and 93/68/EEC). Warranty 2 Year (Return to Base) If you experience any difficulties with this product, please call our Technical Help-Line 01928 581098 or e-mail: tech.help@ventcroft.co.uk Who will be more than happy to assist you with any Ventcroft product query The Manufacturer shall have no liability for any death, personal and or bodily injury and or damage to property or other loss whether direct, indirect, incidental, consequential or otherwise, based on a claim that the Product failed to function. However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, the Manufacturer's maximum liability shall not in any case exceed the purchase price of the Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer. All information is given in good faith and without warranty. E & OE