Queensland Academy. for Science, Mathematics and Technology" Aryaman Sud Solar-Powered Bushfire Detection System Prototype. 4 Perfect IB Scores

Similar documents
Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

BOILED WATER TEMPERATURE MEASUREMENT SYSTEM USING PIC MICROCONTROLLER

ENACTMENT OF SCADA SYSTEM FOR JUDICIOUS DWELLING

CBI-064. User Manual. Caddx to KNX-BUS Interface

Firefighting Robot. I. Introduction

International Journal of Scientific Research and Reviews

Android Controlled Fire Fighting Robot

ESF 15: EMERGENCY PUBLIC INFORMATION

Emergency Response Plan

GSM RFID VOICE Alarm System

Petrol Bunk Automation with Prepaid Card using GSM Identification

Break-in Detector and Alarm System

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

XBee Based Industrial And Home Security System

Required Materials For complete material(s) information, refer to

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

Industrial and home safety Management using GSM

LIQUEFIED PETROLEUM GAS DIFFUSER Home automation based fire security.

Installation, Operating and Maintenance Manual

International Journal of Computer Engineering and Applications, Volume XII, Special Issue, March 18, ISSN

BURGLAR ALARM USING ARDUINO AND PIR SENSOR WITH SMS ALERT Burgoji Santhosh Kumar 1, S.Ramesh 2 1

Smart Gas Booking and LPG Leakage Detection System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Wireless Notice Board using GSM with Fire Detector

Implementation of Artificial Neural Fuzzy Inference System in a Real Time Fire Detection Mechanism

Automated Medication Kit

SIMULATION OF THERMAL SYSTEMS

Global Water Instrumentation, Inc.

Australian/New Zealand Standard

Railway Fault Detection System using Mobile Communication and Sensor Technology

Intelligent monitoring system for automobiles

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Microcontroller based design for Tele-sensing and extinguishing fire

SAFETY PRE-ALARM MONITOR SYSTEM BASED ON GSM AND ARM

PTE0705 Electric Fence Monitor

Gmini 100. User Guide INTELEC SYSTEMS Intelligent Electronic Systems. Web:

Part 1: Playing with Electricity

FIRE AND GAS DETECTION WITH GSM ALERT

Operation System of Washing Machine with Fuzzy Logic Control System and Construction of Detergent box

Guillermo Alberto Pérez Guillen Automation Home

Added password for IP setup page : Password must be in IP format!

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

JOURNAL OF ADVANCEMENT IN ENGINEERING AND TECHNOLOGY

POWER PLANT MONITORING AND CONTROL USING GSM MODEM Syed Zeeshan Ali* 1, Abhijeet Bajpayee 2

Useful Notes: TDM Type S2

2G & 3G GSM Wireless Beam Alarm

ACTIVE INFRARED BARRIER

A Cost Effective Embedded Design for Security and Automation in Industries

Affordable wireless monitoring without compromise

V.ARCHITECTURE IV.IMPLEMENTATION. Battery. Fig.1.Block diagram

DRAGER MONITORING, DETECTION OF GAS HAZARDOUS AND AUTOMATIC BOOKING

Android Operated Intelligent Fire Extinguishing Vehicle

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Construction of An Automatic Power Switch using Infrared Motion Sensor

Designing A Home Automation System by Using RF Receivers

Automatic Customer Counter and Payment Tool for Shopping Centers and commercial spaces

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

System Layout Annotated Instructor s Guide

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Publications and Training Solutions Course Syllabus:

Deluge/Preaction Systems Annotated Instructor s Guide

Australian/New Zealand Standard

Deluge/Preaction Systems Annotated Instructor s Guide

International Journal of Advancements in Research & Technology, Volume 2, Issue4, April ISSN

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

INSTRUMENTATION AND CONTROL TECHNICIAN TRADE REGULATION

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Design and Implementation of Wireless Fire Fighting System

Prototype of Gas Leak Detector System Using Microcontroller and SMS Gateway

Hazardous Gas Detection using ARDUINO

MOBILE CALL GSM Alarm System User s Manual

Consultant Specification AGILE Wireless Fire Detection System

Mukwonago Community Library Emergency Procedures

System. For a better understanding of this product, please read this user manual thoroughly before using it.

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

Design and Development of General Purpose Alarm Generator for Automated System

Campers Alert TM Portable System Hunters Alert TM Portable System

Implementation of an Embedded Microcontroller-Based Intrusion Detection System

Fall Detection and Alert

Accident Prevention System for Boats in Maritime

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

International Journal of Scientific & Engineering Research Volume 9, Issue 2, February-2018 ISSN

Ammonia Detection System Codes and Design Specifications

The WAVE Plus Instant Notification System for Schools and Colleges

DEVELOPMENT OF WIRELESS GAS SENSING SYSTEM FOR HOME SAFETY

Group A Carlos Castro, Courtnie Coleman, Lucas Plager, Patrick Schexnayder

HILLS Series LCD Code Pad User Manual

GAI-Tronics Corporation. Serverless Page Party (SP2) Publication : SP2 Intelligent Intra-Plant Communication and Emergency Notification System

Fire Protection Systems FST 209. COURSE SYLLABUS Fire Protection Systems FST 209 [Semester] CRN 3 Credits

NetworX Series NX-4V2 Control Panel Installation and Startup

School of Engineering Science Simon Fraser University Burnaby, BC V5A 1S6

Department of Fire Safety Policy and Procedures for Fire Watch, Preformed by Residence Education and Services Staff

Transcription:

Queensland Academy for Science, Mathematics and Technology" Aryaman Sud Solar-Powered Bushfire Detection System Prototype 4 Perfect IB Scores

The History of Bushfire Prevention! Fire towers and physical patrols by fire fighters at the scene Utilisation of satellite infra-red scanners is prevalent The advantages of deploying UAVs as a swarm include massive scalability, low communication overheads, reduced need for human supervision, and resilience against individual failure.

Prototyping a Solar-Powered Bushfire Detection System! Research Question How can a rise in temperature be used as an indicator to initiate preventative measures for bushfires in rural areas? Context Bushfires are becoming a regular occurrence in regional Queensland, New South Wales and other international destinations. With the aid of this technology, an increase in temperature will alert the fire brigade of the increased likelihood of bushfires in rural localities.

Basic Functionalities! When the sensor records a temperature above 39 degrees Celsius (Australia-wide agreed temperature that is deemed dangerous), a siren will sound and a red LED will illuminate. Subsequently, a Bluetooth notification will be sent to the paired mobile from the Bluetoothenabled module. The block diagram below shows the elements of the circuitry.

Variables! Independent Dependent Controlled -Nil- Whether each component delivered the desired output Same parts were used The amount of voltage and current flowing through the circuitry.

Materials! Power Supply: Solar Panels Controller: 8051 V2 Bluetooth Transmitter: HC-05 ADC (Analogue to Digital Converters): ADC0809 Temperature Sensor: LM35 Buzzer: 3V 20V Wires x 20 LCD Display: LCD-016M002D Rechargeable Battery: FG20121 800mA Low-Dropout Linear Regulator: LM1117 ATMEL 8-bit Microcontroller with 8K Bytes: AT 89S52 General Purpose Rectifiers (Glass Passivated): 1N4001 Printed Circuit Board (PCB) x 3 Resistors x 5 Green LED x 1 Red LED x 1 Orange LED x 1

Methodology Phase 1: Designing the System" Prior to purchasing the required parts, drawing a schematic diagram was key. Using the online Proteus Schematic software, the following electrical diagram was developed.

Methodology Phase 2 : Constructing the Prototype" Understanding the electrical requirements of the system allowed the commencement of the construction phase after the appropriate parts were acquired. (Parts sourced from S.P. Laboratories Bengaluru, India) Using the previously developed schematic diagram, the physical construction involved the programming of the ATMEL 8-bit Microcontroller through Embedded-C (computer programming language) The following code was programmed into the microcontroller: #include <lcd.h> #include <uart.h> #include <adc.h> char text[]={"solar POWERED THERMAL HEAT SENSOR"}; void main() { // unsigned int i; // int j=0; lcd_ini(); uart_ini(); adc_ini(); buz=0; lcd_cmd(0x80); lcd_string("solar HEAT DET."); //lcd_cmd(0xc0); // lcd_string("detect:"); /*i=0; while(text[i]!='\0') { lcd_data(text[i]); lcd_delay(100); // lcd_cmd(0x18); }*/ while (1) //lcd_delay(300); i++; { //for(i=0x80;i<=0x8f;i++); /* for(i=0;i<34;i++)

Methodology Phase 3: Assembling the Hardware" While providing an understanding of the design of the circuitry, the schematic diagram clarified how it was to be wired. From the diagram, the following instructions were derived: I. The 8051 is powered up by connecting the solar panels to it. II. The ADC0809 is powered up by connecting 5V and ground. III. ADC Clock Pin is connected to P0.0 pin of 8051 IV. ADC OE pin connected to P0.1 pin of 8051 V. ADC ALE pin connected to P3.7 pin of 8051 VI. ADC ST pin connected to P3.5 pin of 8051 VII. ADC A2 pin connected to P3.4 pin of 8051 VIII. ADC A1 pin connected to P3.4 pin of 8051 IX. ADC A0 pin connected to P3.2 pin of 8051 X. Data pins of ADC D0-D7 is connected to P1.0-P1.7 respectively. (example: ADC D0 connects to P1.0) XI. Temperature Sensor (LM 35) is powered up by connecting 5V and ground. XII. Temperature Sensor (LM 35) output is connected to S1 pin of ADC XIII. Bluetooth Module () is powered up by connecting 5V and ground XIV. Bluetooth module TX pin is connected to P3.0 pin of 8051 XV. Bluetooth module RX pin is connected to P3.1 pin of 8051 XVI. Buzzer is connected to P0.3 8051 and another pin is connected to ground

Methodology Phase 4: The Untested Model"

Bluetooth Pairing! 1) Open the Bluetooth Terminal HC-05 app and press the scan button. 2) Select the device HC-05 and enter the code 1234 and then enter. 3) You will return to the homepage. After returning, press the HC-05 button and you will be directed to a black dialogue box. Bluetooth Terminal application

Temperature Emulation Testing (steam testing)! 1. Place the sensor under direct sunlight or a sunlight emulating device. 2. Boil 500mL of distilled water. 3. Hold the temperature sensor into the steam of the boiled water and watch the LCD display show an increased temperature value. 4. Once the temperature value is greater than 39 C, watch the red LED illuminate and listen for a sounding siren. 5. Once the siren sounds, maintain the temperature sensor in the steam and watch the paired device relay the pre-programmed notification. 6. Once the siren has finished sounding, remove the temperature sensor out of the steam and wait until the LCD Display shows a temperature less than 39 C and the LED to stop flashing. 7. If any of the above reactions do not take place or are delayed, note the delay or absence of the reaction for troubleshooting purposes. 8. Repeat steps 3 7 thrice to ensure that each component remains entirely functional.

Testing Data Phase I:! (a) Component Testing in Relation to Temperature Changes Qualita4ve Observa4on: Each component returned the desired output and therefore, the circuit worked completely with negligible delays (< 1 second).

Testing Data Phase II:! (b) Boundary Case Testing Boiled Water Method Trial 1: Tes4ng (Sound) T<38 T<38 38 39 40 >40 >40 No No No Trial 2: Tes4ng (Sound) No T<38 T<38 38 39 40 >40 >40 No No No Trial 3: Tes4ng (Sound) No T<38 T<38 38 39 40 >40 >40 No No No No

Data Analysis & Areas for Improvement! q The overarching aim of the model is to notify the residents and emergency services. q As stated in the preamble, the model induces many limitations that hinder its viability in today s society. q Additional sensors of other bushfire indicators should be added. An example of this is a humidity or smoke sensor. q Using this inexpensive technology, we can reduce the reliance of residents on weather bureaus in areas prone to bushfires like regional Queensland and New South Wales in Australia. q As the harsh terrain of bushfire-prone areas is often a victim of torrential rain, it is essential that a water-proofed body requires to be developed to ensure smoother industrial utilisation.

Evaluation of the Prototype & Scope for Future Research:! q The range of the Bluetooth module is a mere 30m. To ensure that assets (homes, farms and gardens) are not reduced to ashes, GSM technology, radio and televised broadcasts of messages can aid in doing so. q When testing the device we used boiling water. This increased the temperature rapidly and reduced accuracy in testing. q To ensure better testing of the device for industrial usage, it will be better tested under the natural heat of the sun to test the gradual increase in temperature as oppose to an unrealistic increase in temperature. q Develop a water-proof (rain-proof) body for the device. q Look for alternative ways to avoid falsealarms (i.e. from campfires or cigarettes)

The Economic Viability! There lies a benefit of the model since its components are rather inexpensive. This would result in an increased demand as a result of the inexpensive nature of the prototype. If the aforementioned additions are implemented, successful utilization of the prototype is bound to occur.

Conclusion! q The system can successfully detect analogue signals and convert them to digital signals to attain actionable information. q It completes the 3-step DCC principle of detect, comprehend and communicate. q Families can be saved from losing their lives to the heat-induced phenomena while not fuelling the ever-evolving fire of climate change.

Acknowledgements! q S.P. Laboratories for providing information and sourcing appropriate parts that were required to produce the prototype. q Dr. Kirsten Hogg for her continued guidance throughout the development of the system and the quality creation of the poster. q Deanna - for the creative design of the poster.

Bibliography! q Behera, S. (2010). Welcome to S P LABORATORY Bangalore::- Science Projects. Retrieved from http://www.splaboratory.org/scienceproj.html q Proteus - PCB Design, Layout & Simulation software - Labcenter Electronics. (2018). Retrieved from https://www.labcenter.com/ q Welch, M. (2005). Solar Electric Power System Basics Home Power Magazine. Retrieved from https://www.homepower.com/articles/solar-electricity/basics/whatsolar-electricity