... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Similar documents
BENSON.... Variante3 Fired Unit Heaters...

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

... UDSA - UDSBD Gas fired unit heaters...

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

PREEVA air handling unit

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

Gas-fired unit heaters for indoor installation

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

RHC & RHCE gas fired heating coils

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

CP+ Gas & Oil Cabinet Heater Range

... DF / IDF Gas fired combined heating and ventilation ...

... Air Conditioners & Heat Pumps Light Commercial ...

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

OUH Suspended Oil Unit Heater

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

DF-IDF air handling units

RHC GAS FIRED HEATING COILS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Winterwarm Agri UK. Winterwarm. Winterwarm heating solutions ... Winterwarm-quality. heating solutions

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

AMBIRAD.... Vision Radiant Tube Heating Systems...

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Application instructions

Gas-Fired Indoor and Outdoor Duct Furnaces

G34M Bulletin #69/ August 2003

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

AB RANGE GAS FIRED ROOM SEALED AIR CURTAIN INSTALLATION AND OPERATING MANUAL

GAS UNIT HEATERS ARM RANGE

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

LARGE CAPACITY HEATERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Rapid. Suspended Warm Air Heater. Caring for the environment!

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

SUBMITTAL SCHEDULE & DATA

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

GAS AIR HEATER RANGE

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Sirius FS. Working towards a cleaner future

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Installation and Operating Manual Drying Cabinet

Products and prices. CLIMATE TECHNOLOGY feels better, works better.

BENSON VARIANTE 2 RANGE

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

RAYPAK HOT WATER & HEATING

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

UDSA-4. Gas fired Balanced flue / Fan assisted flue unit heater with BMBC burner relay INSTALLATION COMMISSIONING SERVICING

FMH Range Hoods. Installation, Operation & Maintenance Instructions

PT Radiant Heater Range

AB-2 RANGE GAS FIRED AIR CURTAIN

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

BENSON GAS UNIT HEATERS

Sirius WH. Working towards a cleaner future

BENSON LINEAR RADIANT TUBE

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Gas heaters and convectors ROBUR

HEM Heat Exchange Modules

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Powrmatic PZN / PZN X Hot Water Heater

STATIONARY HEATERS 2011/

NVx Suspended Gas Unit Heater Range

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

BENSON VARIANTE 2 RANGE

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

MEC MEC C

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Warm Air Cabinet Heaters

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Transcription:

LCSA - LCSBD - LCSC Gas Fired Unit Heaters

LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial and commercial buildings. Using wall or roof mountings, the heaters are available for either room sealed or conventional power flue applications. Cabinet Specification Formed from sheet steel and painted ivory white to give a robust and durable finish. Louvres painted burgundy red. Model Range > > LCSA axial fan > > LCSBD bi-directional axial fans > > LCSC centrifugal fan These gas fired units are available with eleven heat outputs for use on natural gas (G20) as standard, but alternatively can be specified for use on propane (G31). LCSA heaters are fitted with axial fans and discharge warm air through a front outlet fitted with both horizontal and vertical louvers. Units can be turned through 0 and blow vertically downwards when using the rear mounted suspension points. Burner In-shot burner type with automatic spark ignition and full safety flame proving. On/ Off control is supplied as standard with High/Low and modulating control optional. LCSBD heaters discharge warm air in two opposing directions potentially enhancing distribution whilst reducing capital and installation costs for certain applications. LCSC heaters are fitted with direct drive centrifugal fans and discharge warm air via a duct spigot on the outlet (optional louvers are available for free-blowing applications). For applications requiring a ducted connection on the inlet, an optional blower cabinet for the LCSC is available, which can also be fitted with filters with filters and/or mixing dampers if required. Heat Exchanger Tubular four-pass serpentine arrangement manufactured as standard from alumised steel with stainless steel option. Power Venter Flue Fan These unit heaters are fitted with a powerful venter fan that enables exhaust & combustion air to be run up to a maximum of m each.

Gas Fired Unit Heaters... Options > > Top flue outlet (LCSA) LCSBD with bi-directional axial fans > > Stainless steel heat exchanger > > High/low or modulating burner > > 30 or 60 downflow heads > > Wall brackets (LCSA) > > Destratification thermostat > > Blower cabinet > > Filters (LCSC) > > Mixing dampers with either two position or modulating damper motor (LCSC) LCSC complete with horizontal and optional vertical louvres for free blowing application LCSC complete with mixing box and duct spigot outlet for ducted application Electric Motors All electric motors are ErP compliant where necessary. Efficiency Each heater has been designed and developed with fuel efficiency in mind with efficiencies exceeding the mandatory requirements of building regulations. Fuel Heaters are supplied for use with natural gas (G20) as standard, however propane (G31) is available upon request. Sealed Combustion Circuit The heaters are factory fitted with a power flue venter that enables the heater to be operated in either room sealed or fan assisted flue mode. The flue fan is safety interlocked with the burner control system via a pressure differential sensor. A single phase electrical supply is required to each unit except the LCSC60 which is three phase. This supply should not be switched off except for maintenance

Gas fired unit heaters... Versatile Flue Installation The balanced flue terminal provides both the combustion air inlet and flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall outlet or roof outlet. Additional flue and combustion air pipes may be added, up to a maximum of nine metres of flue pipe, plus nine metres of combustion air pipe. (This reduces by 1.5 metres for every 0 bend fitted). Installation Units may be suspended or alternatively mounted on a suitable non-combustible support. Integral suspension points complete with an M10 female thread are provided to each heater. Balanced flue wall outlet (type C12) eliminates expensive roof opening and flashing Balanced flue roof outlet (type C32) A single phase electrical supply is required to each unit except the LCSC60 which is three phase. This supply should not be switched off except for maintenance. Min 300 mm Units must not be installed in atmospheres containing flammable or explosive vapours, combustible dust, halogenated hydrocarbons or chlorinated vapours. They are also unsuitable for areas where contaminants may affect electrical motors or connections. Combustion air through wall, flue outlet through the roof (C52) Separate combustion air and flue pipes (type C12) for applications where wall thickness exceeds maximum length shown in flue dimension table Heater positions and flue arrangements illustrate LCSA models and are indicative only. For heater and flue clearances please refer to the appliance installation and maintenance instructions. To complement these units heaters, a versatile range of SmartCom control panels are available Optimised Control > > Self adapting optimum start and stop > > Easy set overtime and holiday periods Remote burner reset facility > > Password protection to prevent unauthorised adjustment > > Simple user friendly programming > > Individual seven day programming > > Day, night and frost (5 C) temperature settings > > Three on/off periods per day > > Hours run and service data logging > > Battery back up in the event of mains failure > > High / low or modulating burner control (SmartCom MZ required) Optional SmartCom MZ panel allows up to 16 panels to be linked for centralised control

Gas Fired Unit Heaters LCSA Technical Data Nominal heat output Airflow Temperature rise kw m 3 /h K Model Ref 12 20 30 35 45 50 60 75 120 145 11.1 1 30 21.8 2045 31 25. 2326 33 36.2 3170 33 44.6 4270 31 50.7 5012 30 60. 5214 34.1 72 2 4.5 8024 34 11.3 10764 32 Throw m.5 13.0 17.0 24.0 25.0 23.0 30.0 32.0 31.0 38.0 3.0 Gas Consumption Natural gas G20 Propane G31 Gas connection m 3 /h kg/h Rc 1.27 NA ½ 2.52 1.86 ½ 3.02 2.22 ½ 4.1 3.0 5.1 3. 5. 4.2 Electrical Supply V/ph/hz 230/240V 1N ~ 50Hz Mounting height(s) m 2.5 3.0 4.0 4.0 4.0 4.0 5.0 5.0 5.0 6.0 6.0 Flue diameter nom Combustion air diameter nom Maximum horizontal run Maximum vertical run mmø mmø m m 80 80 Noise level (1) db(a) 43 4 54 55 55 52 61 62 60 61 62 Net weight kg 5 5 64 4 114 114 126 184 242 27 Sound pressure level in db(a), measured at 5 metres from the unit with A=160m² and Q=2 Throw is based upon a terminal velocity of 0.5m/s and is dependent upon mounting height, room temperature & louvre settings. Gas consumption & outputs based upon natural gas G20 having a calorific value of 10.5kWh/m3 GCV & Propane G31 14.0kWh/kg GCV Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. Gas connection size is not supply line size. LCSA 6.8 5.15 8.38 6.17 10.5 8.24 13.80 10.17 137.3 11400 35 15.77 11.62 LCSA Dimensions Model Ref 12 20 30 35 45 50 60 75 120 145 Unit Width A 65 65 65 65 65 128 128 128 128 0 0 Unit Height B 567 567 567 845 845 845 845 845 54 80 1 Unit Depth C 652 652 652 652 652 652 652 652 807 846 846 Overall Depth J 7 785 1 4 4 4 4 4 1022 1057 1057 Suspension Points Suspension Centres Flue & combustion air spigots Clearances (minimum) Top Rear of Fan Bottom Non Access Side Access Side T U V dia P Q R S M N 80 134 211 134 211 M10 Female 42 450 800 42 42 42 550 608 833 180 20 42 770 55 75 160 256 0 20 42 770 6 36 160 256 0 177

Gas fired unit heaters LCSBD Technical Data Nominal heat output Airflow Temperature rise kw m 3 /h K 5 120 145 4.5 00 34 11.3 11088 32 Throw m 31.0 38.0 3.0 Gas Consumption Natural gas G20 Propane G31 Gas connection m 3 /h kg/h Rc 10.5 8.24 13.80 10.17 Electrical Supply V/ph/hz 230/240V 1N ~ 50Hz Mounting height(s) m 5.0 6.0 6.0 Flue diameter nom Combustion air diameter nom Maximum horizontal run Maximum vertical run Noise level (1) mmø mmø m m db(a) 144.0 13408 35 15.77 11.62 Net weight kg Sound pressure level in db(a), measured at 5 metres from the unit with A=160m² and Q=2 Throw is based upon a terminal velocity of 0.5m/s and is dependent upon mounting height, room temperature & louvre settings. Gas consumption & outputs based upon natural gas G20 having a calorific value of 10.5kWh/m3 GCV & Propane G31 14.0kWh/kg GCV Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. Gas connection size is not supply line size. LCSBD C A A B LCSBD Dimensions 5 120 145 Unit Width A 0 0 0 Unit Height B 800 80 1 Unit Depth C 810 810 810 Overall Depth J 1321 1321 1321 Suspension Points Suspension Centres Flue & combustion air spigots Clearances (minimum) Top Rear of Fan Bottom Non Access Side Access Side T U V dia P Q R S M N M10 Female

Gas fired unit heaters LCSC Technical Data Nominal Heat Output Airflow @ min static Airflow @ max static Min static pressure Max static pressure Gas Consumption Natural Gas G20 Propane G31 Electrical Supply kw Pa Pa kg/h Rc V/ph/Hz 20 30 45 60 75 22 2500 2250 50 200 2.52 1.86 1/2" 26 4200 2700 50 300 3.02 2.22 1/2" 230/240V 1N ~ 50Hz 45 5400 4000 50 200 5.1 3. 61 5600 200 6.8 5.15 400/415V 3P ~ 50Hz 7 350 8.38 6.17 5 8 300 11.1 8.24 230/240V 1N ~ 50Hz Blower Electrical Rating W 300 600 0 550 1800 1800 Total Electrical Rating W 453 753 1153 703 153 153 Maximum Flue Run m Noise level db(a) Net Weight kg 54 56 10 155 Min & max static pressure refers to external static pressure of ductwork (by others) Airflows & max static pressure quoted, exclude the use of optional filters and/or mixing dampers Gas consumption & outputs based upon natural gas G20 having a calorific value of 10.5kWh/m3 GCV & Propane G31 14.0kWh/kg GCV Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. Gas connection size is not supply line size. LCSC LCSC Dimensions Model 20 30 45 60 75 Unit Width A 65 65 65 128 128 128 Unit Height B 567 567 845 845 845 54 Unit Depth C 652 652 652 652 652 807 Overall Depth J 1105 1105 1215 1215 0 1455 Suspension Points Suspension Centres Flue & combustion air spigots Duct Outlet Spigot Clearances (minimum) Top Rear of Fan Bottom Non Access Side Access Side T U V dia P Q R S E F G H M N 70 12 307 3 372 134 211 116 607 M10 Female 250 800 42 153 515 42 116 607 42 550 608 833 72 810 180

LCSC with Cabinet Technical Data Nominal Heat Output Airflow @ min static Airflow @ max static kw 20 30 45 60 75 22 3 2 Max static pressure Pa 250 300 250 200 Gas Consumption Natural Gas G20 Propane G31 Electrical Supply kg/h Rc V/ph/Hz 2.52 1.86 1/2" 26 300 2300 3.02 2.22 1/2" 230/240V 1N ~ 50Hz 45 6200 5200 5.1 3. 61 6500 5700 6.8 5.15 400/415V 3P ~ 50Hz 600 7500 8.38 6.17 5 10500 8500 11.1 8.24 230/240V 1N ~ 50Hz Blower Electrical Rating W 300 600 0 550 1800 1800 Total Electrical Rating W 453 753 1153 703 153 153 Maximum Flue Run m Noise level db(a) Net Weight kg 5 5 64 4 114 Min & max static pressure refers to external static pressure of ductwork (by others) Airflows & max static pressure quoted, exclude the use of optional filters and/or mixing dampers Gas consumption & outputs based upon natural gas G20 having a calorific value of 10.5kWh/m3 GCV & Propane G31 14.0kWh/kg GCV Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. Gas connection size is not supply line size. LCSC with Cabinet LCSC with Cabinet Dimensions Nortek Global HVAC Belgium nv J&M Sabbestraat /A000 B-830 Menen Belgium Model 20 30 45 60 75 Unit Width A 65 65 65 128 128 128 Unit Height B 567 567 845 845 845 54 Unit Depth C 1677 1677 1842 2027 2027 21 Suspension Points Suspension Centres Flue & combustion air spigots Duct Outlet Spigot Clearances (minimum) Top Rear of Fan Bottom Non Access Side Access Side T U V W dia P Q R E F G H M N Tel. +32 (0)56 52 5 11 Fax. +32 (0)56 52 5 33 info.reznor@nortek.com www.reznor.eu M10 Female 42 42 42 550 80 70 12 307 3 372 116 607 250 800 153 515 116 607 72 810 Company Standards and Services: All products are tested and approved to CE standards. We are assessed to EN ISO 001 Quality Assurance. We offer a service to our customers; including budget schemes, on site technical support and a comprehensive after-sales package. We reserve the right to change specifications without prior notice. Errors and omissions excepted. Document reference number: GB/REZ/0071015