Flammable and Combustible Liquids Checklist

Similar documents
Flammable and Combustible Liquids

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Working safely with flammable liquids

Flammable and Combustible Liquids: Storage and Handling

Flammable Liquids!!!!!

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

Flammable Materials SC-127

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Element 14.7 Fire Prevention and Control 2018

FACT SHEET Program: Lab Fire Safety

CHAPTER 9 FIRE PROTECTION AND PREVENTION PROGRAM

Flammable Liquid Storage

Stillwater Area Community Services Center Inc.

Above Ground Fuel Tank Requirements

Laboratories and Hazardous Materials. Company Overview

Chapter 34 Flammable and Combustible Liquids

Electron Microscopy Sciences

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Fire Prevention Plan Program

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Consumer Fireworks Retail Sales (CFRS) Facility Requirements.

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

Special Occupancy Requirements

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

Fire and Life Safety Review Form

Fire Protection and Prevention

SEMICONDUCTOR FABRICATION FACILITIES

This policy is applicable to all DMS-owned, -leased and -managed facilities.

Checklist For Building Inspection & Fire Safety

ANALYSIS OF THE STORAGE, DISPENSING, AND TRANSFER OF FLAMMABLE AND COMBUSTIBLE LIQUID FLAVORINGS AT THE CITY BREWING COMPANY, LLC. Michael J.

Explosion-proof Duct Heaters

Consider This HEALTH & SAFETY NEWSLETTER OCTOBER Work Safe. Live Safe. Stay Safe. Issue 4 April Deadline GHS.

Fire Prevention Plan

Fluid Collections at the Smithsonian. Michael Kilby, P.E. Joshua Stewart, P.E. Office of Safety, Health & Environmental Management (OSHEM)

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

New Facilities. Minimum Requirements

NFPA 1124 (2006 Edition) Compliance List. Permanent Facility

Chemical Safety and Security Training Balitvet Indonesian Institute for Veterinary Science July 25-27, 2011

Fire Prevention Plan

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

-SAMPLE- Safety Inspection Checklist: Manufacturing

Family Foster Home Fire Safety Evaluation Checklist Instructions

NFPA 1124 (2006 Edition) Compliance List. Permanent Store

Hazardous Waste Self Audit

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE CONSTRUCTION SAFETY STANDARDS

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Department Of Public Works: Internal Operations

SEMICONDUCTOR FABRICATION FACILITIES

EXAMPLE FIRE PREVENTION AND PROTECTION PLAN WORKSHEET

Exhibits and Trade Shows Permit Application

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION


Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

OUTLINE FOR FIRE PREVENTION ACTIVITY

SBS-H2 Hydrogen Gas Detector Kit

Warehouse Operations Safety Inspection Checklist

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

SEMICONDUCTOR FABRICATION FACILITIES

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

Committee Input No. 60-NFPA [ Sections , ]

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS

Fire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc.

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Camden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA

Part I Extraction Process Equipment

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

CHAPTER 7 ALTERATIONS LEVEL

ESD3000IR ESD3000IR. Infrared Gas Detector

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Spray Painting and Coating

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Monitoring for Toxic VOCs in Oil Industry Applications

Tents and Temporary Membrane Structures Packet

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

(h) Pesticide Application.

Los Angeles International Airport Rules and Regulations SECTION 08 FIRE AND SAFETY

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST

SEMICONDUCTOR FABRICATION FACILITIES

City of Grover Beach Building Division Fire & Life Safety Requirements CANNABIS CULTIVATION, MANUFACTURING AND LABORATORY FACILITIES

Safe Schools: A Health and Safety Check

Agency for Health Care Administration

Department of Public Safety

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

Correctly Classifying and Determining Fire Protection Requirements for High- Hazard Group H Occupancies in New York State (2010 codes)

Permitting and Licensing for Hazardous Material Use and Storage

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Tents and Temporary Membrane Structures Permit Procedure

EM Nov 11. EM Nov 14. Section: TABLE OF CONTENTS Fire Prevention and Protection. 09.A General

SECTION 9. Fire Prevention and Protection

Transcription:

Flammable and Combustible Liquids Checklist This checklist covers the storage and use of flammable or combustible liquids in drums or other containers not exceeding 60 gallons individual capacity. Dispensing and Use Yes No 1. Are only approved pumps, drawing from the top of the storage containers, used to transfer flammable liquids? 2. Are only approved self-closing valves or faucets used in gravity transfer of flammable liquids from storage containers? 3. Is air or gas pressure prohibited for transfer of flammable or combustible liquids unless the tank, drum or container has been approved as a pressure vessel? 4. Are containers and portable tanks used for flammable liquids electrically bonded or grounded during transfers? 5. Are leaks and spills of flammable or combustible liquids disposed of promptly and safely? 6. Are spills of flammable or combustible liquids cleaned up promptly? 7. Is the use of flames or sources of ignition prohibited in areas where flammable vapors may be present? Note: 29 CFR 1926.152(f)(3) requires a distance of at least 50 feet between any source of ignition and flammable liquids. Storage and Use Quantities Yes No 8. Is storage of flammable and combustible liquids limited to that required for current activities and maintenance? 9. Outside of approved cabinets or storage rooms, are containers of Class I liquids limited to a capacity of one gallon, or two gallons, if safety cans are used? 10. Are fewer than 10 gallons of Class I and Class II liquids stored outside of an approved storage cabinet or interior storage room (except in safety cans)? 11. Are fewer than 25 gallons of flammable liquids stored in safety cans outside of an approved storage cabinet or interior storage room?

12. Are fewer than 60 gallons of Class IIIA liquids stored outside of an approved storage cabinet or interior storage room? Note: OSHA under 29 CFR 1926.152(b)(1) does not permit more than 25 gallons of combustible liquids stored outside of an approved storage cabinet or interior storage room. Design and Capacity of Containers Yes No 13. Are only approved containers used for storing flammable or combustible liquids? Note: All gasoline must be stored in approved containers. 14. Are flammable and combustible liquid containers stored in accordance with the requirements of Table 1? Design, Construction, and Capacity of Storage Cabinets Yes No 15. Is storage in cabinets restricted to not more than 60 gallons of Class I or Class II liquids and not more than 120 gallons of Class III liquids? 16. Are all cabinets labeled in conspicuous lettering: "FLAMMABLE-KEEP FIRE AWAY"? 17. Are metal cabinets constructed so that the top, sides and door are at least #18 gauge sheet iron and double-spaced wall with 1-1/2 inch air space? 18. Is the door provided with a three point lock and a sill raised at least 2 inches above the bottom of the cabinet? 19. Are wooden cabinets constructed so that the bottom, sides and top are of approved grade plywood at least 1 inch thick? 20. Are all wooden cabinet joints rabbeted and fastened in two directions with flathead wood screws? 21. When more than one door is used on wooden cabinets, is there a rabbeted overlap of not less than 1 inch? 22. Are no more than three (3) cabinets located in one fire area? 23. Are cabinet vents sealed unless vented to the outdoors? Design and Construction of Inside Storage Room Yes No 24. Are openings to other rooms or buildings from flammable/combustible liquids storage rooms provided with a noncombustible liquid-tight raised sill or ramp at least 4 inches in height Note: Alternatively, the floor of the storage area shall be at least 4 inches below the surrounding floor.

25. Are openings to storage rooms provided with approved self-closing fire doors? 26. Does storage in inside rooms comply with the requirements of Table 2? 27. Is the room liquid-tight where the wall joins the floor? Note: A permissible alternative to the sill or ramp is an open-grated trench inside the room which drains to a safe location 28. Is the electrical wiring and equipment located inside the storage room especially designed to prevent possible ignition of any released flammable vapors Note: Anything which looks like normal household wiring including switches, plugs, lighting or any normal equipment such as radios are not permitted. 29. Is every inside storage room provided with either a gravity or mechanical exhaust ventilation system? 30. Does the ventilation system have an exhaust not more than 12 inches off the floor? 31. Does the ventilation system provide for a complete change of air within the room at least six times per hour? 32. If a mechanical exhaust system is used, is the switch located outside of the door? 33. Are ventilation equipment and lighting fixtures operated by the same switch? 34. When gravity ventilation is provided, are the fresh air intake, as well as the exhaust outlet from the room, located on the exterior of the building in which the room is located? 35. Is there a 3 foot wide clearance in the aisle in every storage room? 36. Is stacking of 30 gallon capacity containers prohibited? General Storage Inside and Outside Buildings Yes No 37. Is the storage of flammable or combustible liquids prohibited near exits, stairways, or areas normally used for the safe exit of people?

38. Is the storage of flammable or combustible liquids prohibited in office areas except that required for maintenance and operation of building and operation of equipment? Note: Permitted materials shall be stored in safety cans, in closed metal containers inside storage cabinets, or in an inside storage room that does not open into public areas of the building. 39. Are portable fire extinguishers available at locations where flammable or combustible liquids are stored? Note: OSHA requires that at least one portable fire extinguisher having a rating of not less than 20-B units be located not less than 25 feet, nor more than 75 feet, from any flammable liquid storage area located outside. 40. Are containers of flammable and combustible liquids closed when not in use? 41. Are combustible waste materials and residues kept to a minimum, stored in covered metal receptacles, and disposed of daily? 42. Are flammable and combustible liquids stored in their original container or in an approved safety can? 43. Unless the original container is designed to be used, are flammable or combustible liquids transferred to an approved safety can prior to use? 44. Are open flames and smoking prohibited in flammable or combustible liquids storage areas? 45. Are storage areas for flammable or combustible liquids kept free from combustible materials? Date of Inspection: Location of Inspection: Signature of Inspector:

Table 1: Maximum Allowable Size of Containers and Portable Tanks Container Type * Flammable Liquids Combustible liquids Class IA Class IB Class IC Class II Class III Glass or approved plastic 1 pt 1 pt 1 gal 1 gal 1 gal Metal (other than DOT drums) 1 gal 5 gal 5 gal 5 gal 5 gal Safety cans 2 gal 5 gal 5 gal 5 gal 5 gal Metal drums (DOT specifications) 60 gal 60 gal 60 gal 60 gal 60 gal Approved portable tanks 660 gal 660 gal 660 gal 660 gal 660 gal * Note: Container exemptions: medicines, beverages, foodstuffs, cosmetics, and other common consumer items, when packaged according to commonly accepted practices. Table 2: Storage in Inside Rooms Fire Protection Provided 1 Fire Resistance Maximum Size Total Allowable Quantities 2 Yes 2 hours 500 sq. ft. 10 No 2 hours 500 sq. ft. 5 Yes 1 hour 150 sq. ft. 4 No 1 hour 150 sq. ft. 2 1 Fire protection system shall be sprinkler, water spray, carbon dioxide, or other system. 2 (gals/sq. ft/floor area) Definitions Approved: approved or listed by a nationally recognized testing laboratory. Class I liquids: flammable liquids (see definition of flammable liquids). Class I liquids: flammable liquids having a flash point below 73ºF and a boiling point below 100ºF. Typical Class IA liquids include: acetaldehyde, ethyl ether, methyl ethyl ether, pentane, and petroleum ether.

Class IB liquids: flammable liquids having a flash point below 73ºF and having boiling points at or above 100ºF. Typical Class IB liquids include: acetone, benzene, butyl acetate, denatured alcohol, ethyl alcohol, gasoline, gin (ethyl alcohol and water), heptane, hexane, isopropyl alcohol, methyl alcohol, methyl ethyl ketone, toluene, and jet fuels. Class IC liquids: flammable liquids having flash points at or above 73ºF and below 100ºF. Typical Class IC liquids include: banana oil (isoamyl acetate), butyl alcohol, propyl alcohol, styrene, turpentine, and xylene. Class II liquids: flammable liquids with flash points at or above 100ºF and below 140ºF. Typical Class II liquids include: diesel fuel, fuel oils, kerosene, Stoddard solvent, anchor-type car wash, and mineral spirits. Class III liquids: flammable liquids with flash points at or above 140ºF. Class III liquids are subdivided into two subclasses: Class IIIA liquids include those with flashpoints at or above 140ºF and below 200ºF, except any mixture having components with flashpoints of 200ºF, or higher, the total volume of which make up 99% of more of the total volume of the mixture. Class IIIB liquids include those with flashpoints at or above 200ºF. This section does not cover Class IIIB liquids. Class IIIA liquids: flammable liquids with flash points at or above 140ºF. Combustible liquid: any liquid having a flash point at or above 100ºF. Combustible liquids are known as Class II and Class III liquids. Flammable liquid: any liquid having a flash point below 100ºF and a vapor pressure not exceeding 40 psia (pounds per square inch absolute) at 100ºF. Flammable liquids are known as Class I liquids and can be divided into Class IA, IB and IC. Flash point: the minimum temperature in degrees Fahrenheit at which a flammable liquid will give off sufficient vapors to form an ignitable mixture with air near the surface or in the container, but will not sustain combustion. KEMI does not assume liability for the content of information contained herein. Safety and health remain your responsibility. This information is to be used for informational purposes only and not intended to be exhaustive or a substitute for proper training, supervision or manufacturers instructions/recommendations. KEMI, by publication of this information, does not assume liability for damage or injury arising from reliance upon it. Compliance with this information is not a guarantee or warranty that you will be in conformity with any laws or regulations nor does it ensure the absolute safety of any person, place or object, including, but not limited to, you, your occupation, employees, customers or place of business.