Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Similar documents
The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

25 th November Title:

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

BS EN ISO : 2010

BS 476: Part 6: 1989+A1:2009

BS EN : 2001 & IEC :2000

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS EN ISO : 2010

BS EN ISO : 2010

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

BS 476: Part 6: 1989+A1:2009

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

NF X : Parts 1, 2, 3, 4 & 5

Review Fire Test Report

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

IMO Resolution MSC 61(67): Annex 1: Part 2

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

FTSG RESOLUTIONS. This document of FTSG resolutions was issued by the Company Secretary 20 July 2012.

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

CERTIFICATE OF COMPLIANCE

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

Fire Test Reports for Interpon D Powder Coatings

Fire Collars for Floor Wastes Understanding BCA Compliance Options

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

Electromagnetic Locking Devices Performance Requirements

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 136

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

Department for Communities and Local Government Research Report:

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

Life Safety and Fire Resistant Glazing Systems

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

CERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Exova Warringtonfire - Expert Witness Directory 2018

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

CERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC

THE HOME OF REACTIVE PROTECTION SYSTEMS

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

Guide to the use of Smoke Seals in Doorsets

CERTIFICATE OF APPROVAL No ME 5085

Guide to interpreting Markings for Single Axis Fire Doors Hinges

Loss Prevention Standard

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

Test Report No: ICL/H17/7967

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

Practice Guidee No.1. of the

CERTIFICATE OF FIRE APPROVAL

PQS Independent type-testing protocol

Introduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets

Test Report: ICL/H18/9039 Rev 1

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

Transcription:

Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Title: The Fire Resistance Performance of a Single- Acting, Single-Leaf modified Doorset Referenced X285, if Tested in Accordance with BS 476: Part 22: 1987 WF Assessment Report No. 389688B Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, 1-38062 Arco (TN), Italy Date: 20 th October 2017 Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429

Page 2 of 20 SECTION TABLE OF CONTENTS PAGE Executive Summary... 3 Introduction... 4 Assumptions... 4 Proposals... 4 Basic Test Evidence... 5 Assessed Performance... 5 Validity... 9 Summary of Primary Supporting Data... 10 Declaration by CHEMOLLI S.A.S. di Eros Chemolli & C.... 11 Signatories... 12 Annex A... 13

Page 3 of 20 Executive Summary Objective This report presents an appraisal of the fire resistance performance of a modified single-acting, single-leaf doorset referenced X285, if subjected to a fire resistance test in accordance with Clause 6 of BS 476: Part 22: 1987. Sponsor CHEMOLLI S.A.S. di Eros Chemolli & C. Address Summary of Conclusions Via Fitta, 1-38062 Arco (TN), Italy It can be concluded that the proposed modified doorset should be capable of providing at least 30 minutes integrity and insulation performance, if subjected to a fire resistance test in accordance with Clause 6 of BS 476: Part 22: 1987, from each direction separately. Valid until 21 st October 2022 This report may only be reproduced in full. Extracts or abridgements of reports shall not be published without permission of Exova Warringtonfire.

Page 4 of 20 Introduction This report presents an appraisal of the fire resistance performance of a modified single-acting; single-leaf doorset referenced X285. The doorset is required to provide at least 30 minutes integrity and insulation performance, if subjected to a fire resistance test in accordance with Clause 6 of BS 476: Part 22: 1987, from each direction separately. FTSG The data referred to in the supporting data section has been considered for the purpose of this appraisal which has been prepared in accordance with the Fire Test Study Group Resolution No. 82: 2001. Assumptions General Construction Supporting Construction Door Gaps Installation It is assumed that the general construction of the doorset and the materials used in the construction will, unless specifically detailed in this report, be identical to those of the tested assembly. The doorset shall also be constructed in a similar manner, with regards to the attachment of various parts. It is assumed that the doorset shall be fixed to a masonry or reinforced concrete supporting construction which is capable of maintaining adequate support for the required period of 30 minutes. It is assumed that the door leaf to frame clearance gaps shall not exceed those of the previously fire tested assembly. It is assumed that the doorset will be installed by competent installers in a similar manner to that used when installing the fire tested assembly. Proposals The test referenced RINA0116FR was performed in accordance with UNI EN 1634-1: 2014, on two specimens of the proposed single-acting, single-leaf doorset referenced X285, one opening towards and other opening away from the heating conditions of the test. It is proposed that the tested X285 doorset is assessed to provide increased leaf dimensions of up to 2768 mm high (at 1024 mm wide) or 1177 mm wide (at 2407 mm high) subject to a maximum leaf area of 2.83m 2 with a reduced 30 minutes integrity and insulation performance criteria in accordance with Clause 6 of BS 476: Part 22: 1987 It is further proposed that the assessed doorset will include an arched head and face fixed mirrors to the closing face to provide 30 minutes integrity and insulation performance criteria in accordance with Clause 6 of BS 476: Part 22: 1987. Details of the proposed 30 minutes doorset as previously discussed are included within Annex A

Page 5 of 20 Basic Test Evidence RINA0116FR A fire resistance test in accordance with UNI EN 1634-1 on two specimens of a single-acting, single-leaf doorset referenced X285, one inward opening and one outward opening. Assessed Performance The doorsets were of identical specification and both had overall nominal dimensions of 2450 mm high by 1100 mm wide, with a door leaf having dimensions of 2407 mm high by 1024 mm by 70 mm thick. Both the inward opening and outward opening doorsets satisfied the integrity and insulation (I 1 ) performance criteria for a period of 69 minutes at which time the test was discontinued without failure. The previous fire test was performed in accordance with EN 1634-1. Testing experience has demonstrated that this represents a more arduous test compared with BS 476: Part 22: 1987. Heating Conditions Furnace Pressure Performance Criteria Although the two test methods specify a near identical temperature/time heating curve, the furnace thermocouples specified by the EN test method are less responsive to temperature rise compared with those specified for a test to BS 476: Part 22: 1987. The consequence of this is that it is necessary for the furnace to be worked harder for a test to EN 1634-1 in order to maintain the specified furnace temperature, particularly during the early stages of the test due to the required rapid temperature increase. EN 1634-1 requires the neutral pressure axis within the furnace to be maintained at a height of 500 mm above the threshold of the doorset. For a test in accordance with BS 476 the neutral pressure axis is specified at a height of 1000 mm. Based a furnace pressure gradient of 8.5 Pa per metre height (as assumed by both test methods), the pressure across the upper edge of a doorset for a test in accordance with EN 1634-1 would therefore be nominally 4.25 Pa greater than for the same test performed in accordance with BS 476: Part 22: 1987. The integrity performance criteria of both test methods are near identical, both requiring the specimen to be evaluated for sustained flaming and for impermeability using the cotton pad and the 6 mm and 25 mm gap gauges. The insulation performance criteria specified for I 1 within EN 1634-1 imposes a limitation on the mean temperature rise of the door leaf of 140 o C. Any individual temperature rise recorded on the door leaf or frame must not exceed 180 o C. The same temperature rise limitations are imposed by BS 476: Part 22: 1987. For the I 1 performance criteria specified within EN 1634-1, the thermocouples shall be placed no closer than 25 mm to the edge of the door leaf. Under BS 476: Part 22: 1987, this distance is increased to 50 mm.

Page 6 of 20 Although the temperature rise requirements of the two standards are therefore identical, the option for the thermocouples to be positioned in closer to proximity to the edge of the door leaf results in a potential reduction in the period of insulation performance under EN 1634-1, compared with BS 476: Part 22: 1987. Summary of Comparison The two test methods are very similar in most respects but differences in the furnace instrumentation, the specified furnace pressure and different surface thermocouple positioning requirements result in a more onerous testing regime under EN 1634-1. The previously tested doorset would therefore be expected to provide at least 30 minutes integrity and insulation performance if subjected to a fire test in accordance with Clause 6 of BS 476: Part 22: 1987, from each direction separately. Leaf Sizes The doorset tested under the reference RINA0116FR incorporated two specimens of a single-acting, single-leaf doorset referenced X285, one inward opening and one outward opening. Each leaf had dimensions of 2407 mm high by 1024 mm wide by 70 mm thick and both demonstrated their ability to provide 69 minutes integrity and insulation performance in accordance with UNI EN 1634-1 It is proposed that the maximum leaf dimensions may be increased, to 2768 mm high (at 1024 mm wide) or 1177 mm wide (at 2407 mm high), subject to a maximum area of 2.83 m 2 for an integrity period of 30 minutes. The doorsets tested under reference RINA0116FR achieved 69 minutes integrity and insulation performance when tested in accordance with UNI EN 1634-1. This represents an overrun for the required 30 minutes of 130 %. The distortion data recorded at 30 minutes noted a maximum overall distortion of 6 mm measured at point B located at the top lock edge corner of the inward opening door leaf. Taking into account both the overrun and the distortion data in accordance with the PFPF rules we can permit an increase in leaf width, leaf height and leaf area as follows: 2768 mm high (at 1024 mm wide) or 1177 mm wide (at 2407 mm high), subject to a maximum area of 2.83 m 2 Arched head The proposed door leaf design incorporates and arched head detail utilising 170 mm radii to the top hang and lock edge corners as shown below:

Page 7 of 20 The arched head arrangement may experience greater fire induced distortions / deflections which can lead to a loss of impermeability between the leaf and frame. The use of the proposed 4No rails to the top edge of the door leaf in lieu of the previously tested 2No rails would be expected to result in a more dimensionally stable door leaf, which would be expected to experience smaller deflections / distortions during the required 30 minutes test period. Smaller deflections are considered beneficial since the vulnerable leaf / frame gaps will be less prone to detrimental erosion if they remain more stable. Furthermore a Chemolli Firebolt A2 thermal bolt has been included to each arched detail as shown below: It is therefore considered that the arched head arrangement to the X285 door leaf when modified as previously discussed would not be deleterious to the required 30 minutes integrity and insulation performance in accordance with BS 476: Part 22 and on this basis is positively appraised. Mirror It is further proposed that the modified X285 door leaf as previously discussed may be provided with the addition of a decorative mirror without detracting from the fire resistance performance for a period of 30 minutes. The proposal requires that a 6 mm thick mirror is bonded to the closing face of the door leaf with contact adhesive. The mirror will not extend beyond the closing face of the door leaf or return over the leaf edges, so will not interfere with the activation of effectiveness of the intumescent seals at the perimeter of the door leaf. Should the fire exposed face of the door leaf include the proposed 6 mm thick mirror it would initially inhibit the ignition of the door leaf face. Whilst this is only likely to occur for a few minutes, in doing so the charring of the exposed face of the door leaf will be delayed. The facing will eventually detach from the leaf and provide no further benefit after that time. As the mirror is bonded only to the door leaf it will eventually detach from the leaf itself and provide no further benefit after such time.

Page 8 of 20 Should the unexposed face of the door leaf include the proposed 6 mm thick mirror it would be expected to provide additional stiffness to the door leaf providing greater dimensional stability and resistance to bowing during exposure to fire. It is therefore considered that the inclusion of the mirror as previously discussed when positioned as shown below would not be deleterious to the required 30 minutes integrity and insulation performance required in accordance with BS 476: Part 22 and on this basis is positively appraised. Conclusion It can be concluded that the proposed modified X285 doorset should be capable of providing at least 30 minutes integrity and insulation performance, if subjected to a fire resistance test in accordance with Clause 6 of BS 476: Part 22: 1987, from each direction separately.

Page 9 of 20 Validity This assessment is issued on the basis of test data and information available at the time of issue. If contradictory evidence becomes available to Exova Warringtonfire the assessment will be unconditionally withdrawn and CHEMOLLI S.A.S. di Eros Chemolli & C. will be notified in writing. Similarly the assessment is invalidated if the assessed construction is subsequently tested because actual test data is deemed to take precedence over an expressed opinion. The assessment is valid initially for a period of five years i.e. until 21 st October 2022, after which time it is recommended that it be returned for re-appraisal. The appraisal is only valid provided that no other modifications are made to the tested construction other than those described in this report.

Page 10 of 20 Summary of Primary Supporting Data RINA0116FR A fire resistance test in accordance with UNI EN 1634-1 on two specimens of a single-acting, single-leaf doorset referenced X285, one inward opening and one outward opening. The doorset had overall nominal dimensions of 2450 mm high by 1100 mm wide, with a door leaf having dimensions of 2407 mm high by 1024 mm by 70 mm thick. The door leaf briefly comprised a 54 mm thick S2.54 Chemolli panel of 650 kg/m 3 nominal density surrounded by Oak stiles and rails of 760 kg/m 3 nominal density with facings to both sides comprising a central layer of 1 mm thick aluminium with a density of 2700 kg/m 3 sandwiched between 2No. layers of 3.5 mm thick MDF with a density of 800 kg/m 3. The door leaf was hung within a door frame comprising Oak sections. Intumescent seals referenced Promaseal LFCSK 15 x 1.8 mm were included within the assembly. The door leaf included four Chemolli Firebolt A1, three Chemolli Firebolt A2 and two Chemolli Firebolt A5 thermally activated bolts. Test Results: Doorset A Doorset B Integrity Sustained flaming 69 minutes* 69 minutes* Gap gauge 69 minutes* 69 minutes* Cotton Pad 69 minutes* 69 minutes* Insulation (I 1 ) 69 minutes* 69 minutes* (I 2 ) 69 minutes* 69 minutes* *The test was stopped at 69 minutes without failure to Doorset A or Doorset B Test date : 25 th September 2015 Test sponsor : Chemolli Fire

Page 11 of 20 Declaration by CHEMOLLI S.A.S. di Eros Chemolli & C. We the undersigned confirm that we have read and complied with the obligations placed on us by the UK Fire Test Study Group Resolution No. 82: 2001. We confirm that the component or element of structure, which is the subject of this assessment, has not to our knowledge been subjected to a fire test to the Standard against which the assessment is being made. We agree to withdraw this assessment from circulation should the component or element of structure be the subject of a fire test to the Standard against which this assessment is being made. We are not aware of any information that could adversely affect the conclusions of this assessment. If we subsequently become aware of any such information we agree to cease using the assessment and ask Exova Warringtonfire to withdraw the assessment. Signed: For and on behalf of:

Page 12 of 20 Signatories Responsible Officer M Tolan* - Certification Engineer Approved A Kearns * - Technical Manager * For and on behalf of Exova Warringtonfire. Report Issued: 20 th October 2017 This copy has been produced from a.pdf format electronic file that has been provided by Exova Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Exova Warringtonfire. The pdf copy supplied is the sole authentic version of this document. All pdf versions of this report bear authentic signatures of the responsible Exova Warringtonfire staff.