PRODUCT: SEL-SV-MCQ-O5- K6 VERSION 3. TECHNICAL SHEET /5 SAC 55 39-66 APPLICATION Flame presence signal sensor-transmitter recommended for single- or multiple-burner systems for industrial or commercial use of any kind of power, operating on gas, oil or any other fuel producing flame emitting or visible rays (yellow flame) either under continuous operation (switches burner on / off within a period of time longer than 24 hours). It is provided with sensor-transmitter fault self-diagnosis circuit at every 4 seconds operation (self-checking circuit). Item 4..4.4 of ABNT NBR 233 Standard establishes as mandatory the use of sensor with fault self-diagnosis on burners from, Kcal power operating for 24 hours or longer without at least one shutdown. This product meets the requirements of ABNT 233 standard Sept./2 revision. It is provided with independent sensor sensitivity setting, which facilitates using it in multiple-burner applications, for discrimination of adjacent flames and signal transmitting circuit, which enables its application at distances up to,3 meters between the sensor and the flame detector relay or programmer. The device is provided with two sensors: one ultraviolet (8 nm to 26 nm) and another infrared (5 nm to nm) sensor. The MCQ system is composed of the flame presence detector relay, sensor SEL-SV-MCQ and programmer / monitor. Refer to the MCQ system functional diagram. In the MCQ system, detector relay is MCQ system s master unit; it establishes communication to all other set units, processes and performs the operations required for providing the flame control. It processes the ultraviolet and infrared radiation sensor signals and other parameters as well. The signals are programmed and monitored through the programming / monitoring unit MCQ. accessory and stored in (non-volatile) flash memory of the CHM-F- Through the accessory, it enables control and signaling operations via keyboard and alphanumeric LCD display as well as programming mode (U, I, U and I, U or I) and U and I set point. It also enables monitoring absolute and percent values of and, self-check, temperature on SEL-SV-MCQ, events in progress, the latest 6 events occurred in sequential order with date / time, their code, event date and time and parameters programmed. It further allows applying test programs for the output relays as well as their LEDs. Velho São Paulo SP Tel/Fax: (55 ) 39-66 sheet when it deems it necessary Dec/2 /5
PRODUCT: SEL-SV-MCQ-O5- K6 VERSION 3. TECHNICAL SHEET 2/5 SAC 55 39-66 TECHNICAL DATA Micro-processed with watchdog - failsafe Version: 3. NOTE: VERSION 3. WAS CREATED FROM THE NEED OF TECHNOLOGICAL UPDATE IDENTIFIED WITH CUSTOMERS. VERSION 3. OPERATES ONLY WITH THE SYSTEM MCQ PRODUCTS IN THE SAME VERSION OR IN SUPERIOR VERSION (RELAY / SENSOR / PROGRAMMER). EQUIPMENT FROM PREVIOUS VERSIONS MAY BE UPDATED TO VERSION 3., IN WHICH EVENT CUSTOMER MUST SHIP THE SET OF PRODUCTS COMPOSING THE MCQ SYSTEM TO SELCON ON MANDATORY BASIS. THE VERSION 3. IDENTIFICATION IS SHOWN ON THE OUTSIDE OF SEL-SV-MCQ SENSOR AND SYSTEM CHM-F RELAY CASING. - Supply voltage: 5 VAC + -5%; 5 / 6Hz ± 3% - Power consumption (max): 6 VA - Internal fuse: 25 ma, source protection, retarded, mounted on socket, model MST 2, Fusibras Ltda. make or similar. - Failsafe: provided with fault self-checking system with 4-second cycles - Sensor: photocells sensitive to ultraviolet and/or visible / infrared radiation - Signaling (switched on) - OP (Vm) Indicates sensor in operation. Blinking: indicates system fault - (Vd) Indicates presence of ultraviolet radiation flame - (Vm) Indicates presence of flame by infrared radiation - LCOM (Am) Indicates communication deficiency or fault - Operation: over communication channel RS 485 with relay and programmer -. - Sensitivity setting: through programmer / supervisor - Plain (4x4 mm) or convex (4x3 mm) lens, quartz crystal, resistant to combustion chamber pressure up to 5 psi (344.75 kpa). - Ambient degree of protection: IP 66 - Connection to process: Collar with inner thread Rp (NBR 644), for connection to viewing tube - Electric connection: Three (3) ½ x 4 NPT inner thread holes for connection of flexible conduits - Wiring: 8 inner leads (7 ºC.33 mm² - 3 V) - Reduction tube (flame view): Provide tube (Fig 2) with diameter between./2 and 3, defined as function of its length and ability of emitting flame ultraviolet and/or infrared / visible radiation. - Maximum distance from sensor to flame presence detector relay :,3 meters - Weight: 3, grams - Operating ambient temperature: to 6 º C - Storage temperature: - 5 º C to 65 º C (dry heat) - Maximum operating relative ambient air humidity: 9% without condensation (NBR 529) - Casings: SAE 323 and SAE 359 cast aluminum alloy case - Painting: Epoxy powder, grey color - Identification tag: (stainless steel).5 mm thickness, 9 mm diameter, fastened by 2 screws. - Warranty: 2 months (see warranty certificate) Velho São Paulo SP Tel/Fax: (55 ) 39-66 sheet when it deems it necessary Dec/2 2/5
PRODUCT: SEL-SV-MCQ-O5- K6 VERSION 3. TECHNICAL SHEET 3/5 SAC 55 39-66 Dimensional Drawing (mm) 44,5 " Rp 29 ( NBR 644 ) 97 Thread depth 5mm Ø24 Connection to process 4,5 Ø2 ~85 INSTALLATION REFRACTORY REDUCTION TUBE ~9 3 x /2-4 NPT FIG NIPPLE SEL-SV-MCQ- 5-K6 P cam "Rp P ext Accessory: Articulate Connection ACS-CN-C(former SA-36-SE) Wiring diagrams COMBUSTION CHAMBER WALL FIG 2 Velho São Paulo SP Tel/Fax: (55 ) 39-66 sheet when it deems it necessary Dec/2 PURGE AIR P ext > P cam See item: Precautions 3/5
PRODUCT: SEL-SV-MCQ-O5- K6 VERSION 3. TECHNICAL SHEET 4/5 SAC 55 39-66 5V SEL-SV-MCQ SELCON LTDA. PRODUTO: Indústria Brasileira MODO RESET ACK TST VRF RELE DHS HFL 5 6 7 8 2 3 4 5 6 7 8 2 3 4 6 8 2 3 5 ON/OFF L2 F Rearm 5VAC Power Supply N (L) OBS.: PROVIDE SIMULTANEOUS ENERGIZING OF RELAY and SEL-SV-MCQ. CHM-F OUTPUT RELAY COIL? TRHTH TABLE OUTPUT RELAY CONTATS STATUS COMMENTS ACS-CN-C Q (K + K2) Flame Presence (control) (K3) Flame Presence (signaling) F2 F3 F4 F5 K2 K K3 (K4) Sistem Fail (control) 2 3 4 5 6 7 8 9 K4 ACK DHS SELCON LTDA. PRODUTO: Indústria Brasileira TST HFL VRF MODO RESET RELE No Yes Yes (K+K2) No (K4) No (K+K2) No (K4) Yes (K+K2) Yes (K3) Yes (K4) Yes Yes (3/4) Open (K+K2) No (K4) No (3/4) Open (8/9) Open (3/4) Open (8/9) Closed (3/4) Closed (5/6) Closed (8/9) Closed (8/9) Open terminals 3/4 - V No Flame+ operanting, terminals 3/4 - V Whit or without flame+ failed terminals 3/4 - V LOGIC UNIT + CMS - CMS ACS-CB-3 FEMALE CONNECTOR 2 3 4 5 6 7 8 9 2 ACS-CB-C427/457 = The status does not matter = Status OFF = Status ON NOTE: FOR EACH BURNER, PROVIDE AN MCQ SYSTEM; ECEPT PROGRAMMER, BECAUSE WITH ONE UNIT, "N" SYSTEM MAY BE PROGRAMMED/SUPERVISED (ONE AT A TIME). - + -4Vdc 4-2mA - + - C (FLAME PRESENCE DETECTOR RELAY) CH Local Flame Signaling FIELD PANEL ACS-CV -CMS +CMS K/K2 K3 K4-4v L CH CONTROL USAGE. SIGNALING USAGE. : SYSTEM FAIL - CONTROL USAGE. : PROPORTIONAL SIGNAL FOR FLAME SIGNALING : ENERGIZED SIGNALING. F L(max) : SYSTEM FAIL - : PRESENCE OF ULTRAVIOLET - : PRESENCE OF INFRARED - : MAIMUM DISTANCE BETWEEN and SEL-SV-MCQ = L(max) < 3 m Mode - proportional to the ultraviolet rays focusing on ultraviolet sensor. Mode - proportional to the infrared rays focusing on infrared sensor. and Mode - proportional to the focusing rays with lower number of incident rays. or Mode - proportional to the focusing rays with higher number of incident rays. Site: A E Site: A E FIG 3 ORDERING CODE: SEL-SV-MCQ-O5- K6 Velho São Paulo SP Tel/Fax: (55 ) 39-66 sheet when it deems it necessary Dec/2 4/5
PRODUCT: SEL-SV-MCQ-O5- K6 VERSION 3. TECHNICAL SHEET 5/5 SAC 55 39-66 SEL-SV-MCQ - LENS O OPTIONAL ITEMS CONNECTION TO PROCESS DEGREE OF PROTECTION VIEWING TUBE ADAPTER - (d) d2 = 5 (d3) K6 d = 2 => plane OR => RP With fault selfchecking d3 = => none OR IP 66 d = 3 => convex d3 = => RP(M) / NPT(F) NOTE: Use this sensor with relay and programmer, which shall be specified separately. WARNING: Install the sensor upside down to prevent dirt buildup and keep the sensor face clean. Attention: Provide cooling air inlet and inspection tube cleaning as depicted on the figure above. Use θ < 4º C clean and dry air; flow rate: > 5 scfm; pressure > than the combustion chamber pressure in at least 3 mm water column. The sensor must see the flame, if possible, on the first 3% of the same, from the burner nozzle where higher visible radiation emission exists. Use the sensor only with programmers and/or detector relays made by Selcon. OTHER PRODUCTS AND ACCESSORIES: Flame relays: CHM SE, CHM P, CHM M, CHM M IIIMe (with base) and CHM F Automatic valve proving control: CHM T Ignition and flame monitoring programmers: PRG SE, PRG E, PRG Ie, PRG-Ie IIIMe (with base), PRG I, PRG M and PRG M IIIMe (with base) Flame optical sensors: SEL- SV Ionization flame sensors and ignition electrodes: SEL HT (standard) and SEL HT E (sensors and electrodes mounted under drawing or customer sample- special); Flame signal transmitter: ACS T (up to 5 meters between sensor and relay or programmer) Flame signal converter for 4-2 ma: ACS CV Ignition transformers: ACS TE (for supply in VAC or VCC) Timed ignition panel: ACS IT Portable ignitor: ACS IP (operates on batteries) Ignition panel (operates on batteries): ACS PN E Ignition panel and flame monitoring: PRG-Ie/O3 Cables: ACS - CB (ignition / sensing / communication / control) Touch-sensitive connector and protector for ignition cable: ACS CP Articulate connection ACS CN Ignition and monitoring panel: ACS PN (on request) Reform service for pilot burners: on request PRODUCTION DATA SUPERVISOR LINE Velho São Paulo SP Tel/Fax: (55 ) 39-66 sheet when it deems it necessary Dec/2 5/5