Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions

Similar documents
Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Experimental Study and Analysis of Condenser Performance under Dual Backpressure Operation Mode

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Parametric Analysis of Surface Condenser for Thermal Power Plant

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Analysis to speed up of the start-up of steam boiler OP-380

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

A Simulation Study on the Energy Efficiency of Gas-Burned Boilers in Heating Systems

Influence of Feed Water Heaters on the Performance of Coal Fired Power Plants

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Minimization of Mass Flow in District Heating Network Equipped with One Stage Domestic Hot Water Production Substations

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Chapter 10 VAPOR AND COMBINED POWER CYCLES

Compression of Fins pipe and simple Heat pipe Using CFD

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

THERMAL ANALYSIS OF CAR AIR COOLER

GPPS-2017-Put 4 digit paper number here

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance


Key Words: Microalgae; Solar Dryer; Exergy Analysis; Energy Analysis;

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Thermodynamic Analysis of Combined Vapor Compression and Vapor Absorption Refrigeration System ABSTRACT

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Steam Power Cycles Part II

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

Thermodynamic Analysis of Ammonia-Water Absorption Refrigeration System with Ejector

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

American International Journal of Research in Science, Technology, Engineering & Mathematics

Effect of Magnetic Field on Convective Drying Of Ceramic Clay

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Falling Film Heat Exchangers for Solar Water Heaters

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Evaluation of HCFC Alternative Refrigerants

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

ENSC 388: Engineering Thermodynamics and Heat Transfer

COMPARISON OF HIGH TEMPERATURE HEAT PUMPS ON 4-TH GENERATION REFRIGERANTS

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Passive cooling of telecommunication outdoor cabinets for mobile base station

η second law = Second law efficiency

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Chapter 8. Production of Power from Heat

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

CASE STUDY REGARDING ENERGY EFFICIENCY OF A VENTILATION SYSTEM WITH RECUPERATIVE HEAT RECOVERY

Experimental Investigation of Tube Configuration for a Surface Condenser

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Andrzej Kesy Kazimierz Pulaski University of Technology and Humanities, Radom, Poland, and

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Transcription:

American Journal of Energy Research, 215, Vol. 3, No. 1, 13-18 Available online at http://pubs.sciepub.com/ajer/3/1/3 Science and Education Publishing DOI:1.12691/ajer-3-1-3 Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions Rafał Laskowski, Adam Smyk, Janusz Lewandowski, Artur Rusowicz * Warsaw University of Technology, Institute of Heat Engineering, Warsaw, Poland *Corresponding author: rusowicz@itc.pw.edu.pl Received December 27, 214; Revised March 31, 215; Accepted May 12, 215 Abstract A steam condenser is an important component of a power plant, in which the heat of condensation is discharged to the environment. Changes of inlet temperature and mass flow rate of cooling water affect the steam pressure, which has a significant impact on the efficiency and power generated in the low-pressure (LP) part of the steam turbine. On the basis of data obtained from a simulator of the steam condenser and the actual measurement data from a 2-MW power plant, an analysis was performed of how the inlet cooling water temperature, the cooling water mass flow rate, and the steam mass flow rate affect the steam condenser effectiveness, the heat flow, the steam pressure in the condenser, and the efficiency and power of the LP part of the steam turbine. In the case of heat exchangers with a condensation zone, e.g. in a regenerative heat exchanger, the maximum value of the effectiveness ε means obtaining the maximum value of the heated fluid temperature at the outlet. Since the role of the steam condenser (providing the lowest possible vacuum) is slightly different from the role of a classical heat exchanger, increasing the value of ε does not mean better performance of the steam condenser. An even greater disparity exists in the evaluation of the performance of a system comprising the steam condenser and the LP part of the steam turbine. It was therefore suggested to evaluate the performance of the steam condenser and the LP part of the steam turbine using the parameter of efficacy, defined as: δ=(1-ε)=δt min / T max. Moreover, for practical purposes, the relation (6) was given for the power of the LP part of the steam turbine as a function of the cooling water mass flow rate and its temperature at the inlet to the steam condenser. Knowing the characteristics of the LP part of the steam turbine and of the steam condenser, one can optimize operating conditions of the system. Keywords: steam condenser effectiveness, low-pressure part of the steam turbine, steam condenser efficacy Cite This Article: Rafał Laskowski, Adam Smyk, Janusz Lewandowski, and Artur Rusowicz, Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions. American Journal of Energy Research, vol. 3, no. 1 (215): 13-18. doi: 1.12691/ajer-3-1-3. 1. Introduction Condensers are the largest heat exchangers in power plants, where the steam flowing from the low-pressure (LP) part of the steam turbine is condensed. To cool down the steam, water, taken from rivers, lakes or cooled in cooling towers, is most often used. Condensers are normally shell and tube heat exchangers. The cooling water flows inside the tubes, and the steam condenses on their outer surface. The application of the condenser allows to close the thermal cycle and transfer the heat of condensation to the environment [1,1]. A diagram of the steam condenser, its location in the heat system, the notation used and a sample temperature distribution along the heat transfer surface are shown in Figure 1. Within the steam condenser, the cooling water temperature at the inlet (T c1 ) and outlet (T c2 ) of the condenser, the cooling water mass flow rate ( m w ) and the steam pressure (p h ) are most often measured. Figure 1. A location of the steam condenser in the heat system with a sample temperature distribution

14 American Journal of Energy Research The steam mass flow rate ( m p ) is usually calculated from the energy balance. For water-cooled condensers with river or lake water, the temperature at the inlet to the condenser varies in summer and winter months. The cooling water mass flow rate can be adjusted by setting the blade angle in a pump [5,8,14]. Changes in the cooling conditions and the inert gas removal efficiency affect the performance of the steam condenser [4,8,12,13] and the condensing steam pressure [2,5,1,14,16,17], which in turn affects the operating conditions of the LP part of the steam turbine, and the internal power it achieves [11]. This article analyses how changes in water temperature at the inlet to the condenser and the cooling water and steam mass flow rates affect the steam condenser effectiveness, the heat flow, and the pressure in the steam condenser, and how changes in these values affect the efficiency and electrical power output of the LP part of the steam turbine. For heat exchangers with a phase change of one fluid, the heat exchanger effectiveness is defined as [2,6,7,13] ka c2 Tc1 mc cw T ε = = 1 e T T h c1 (1) where: k overall heat transfer coefficient, A heat transfer surface area, c w water specific heat, m w mass flow rate of cooling water, T h steam temperature, T c1 water temperature at the inlet to the steam condenser, T c2 water temperature at the outlet of the steam condenser (Figure 1). effectiveness,685,68,675,67,665,66,655,65,645,64 275 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 inlet cooling water C effectiveness Q Figure 2. Change in the steam condenser effectiveness and heat flow as a function of water temperature at the inlet to the steam condenser steam pressure bar,7,365,65,36,6,355,55,35,5,345,45,34,4,335,35,33,3,325,25,32,2,315 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 inlet cooling water C pressure efficacy Figure 3. Steam pressure and efficacy of the steam condenser as a function of water temperature at the inlet to the steam condenser For steam condensers, the parameter ε is not an unambiguous measure for assessing their role in the 284 283 282 281 28 279 278 277 276 efficacy cooling system of a power plant. From a comparison between Figure 2 and Figure 3, it can be seen that the increase in the steam condenser effectiveness is followed by an increase in the steam pressure in the condenser. Higher pressure means the deterioration in the performance of the steam condenser, whose main task is to receive heat from the condensing steam and ensuring the lowest possible vacuum in the steam condenser. It appears that a better parameter to evaluate the steam condenser performance is the difference δ=1-ε. An increase in the value of the parameter δ corresponds to a decrease in the steam pressure in the steam condenser, and lower vacuum means higher power of the turbine. Given that δt min =T h -T c2 and T max =T h -T c1, we can express a modified effectiveness of the condenser, called efficacy, with the relation: ka δt 1 min mc δ = ε = = e cw (2) Tmax where: δt min terminal temperature difference, T max maximum temperature difference, ε steam condenser effectiveness, δ efficacy of the steam condenser. To illustrate the analysis, including the evaluation of the steam condenser efficacy expressed with the equation (2), data obtained from a steam condenser simulator and measurement data for the steam condenser and the LP part of the turbine in a 2-MW power plant were used. 2. Steam Condenser Data from a Simulator The steam condenser simulator was developed based on a steady state zero-dimensional model, and relations known in the literature for heat transfer coefficients for water and steam [2,3,5,9] were used. The input parameters to the simulator are: water temperature at the inlet to the steam condenser, cooling water mass flow rate, and steam mass flow rate. The output parameters are: water temperature at the outlet of the steam condenser, and steam pressure (temperature). The following design parameters of the steam condenser were assumed: cooling water mass flow rate of 7995 kg/s, cooling water temperature of 17 C, steam pressure of.414 bar and temperature of 29.56 C, and steam mass flow rate of 123 kg/s. By changing these three input parameters, a set of data for off-design operating conditions of the steam condenser was obtained, as illustrated in Figure 2 to Figure 7. 2.1. Change in the Cooling Water Temperature at the Inlet to the Steam Condenser In the first case, the temperature of the cooling water at the inlet to the steam condenser was changed from 1 C to 25 C, in one degree Celsius increments. The cooling water and steam mass flow rates were constant and equal to the nominal values. The influence of the change in the cooling water inlet temperature on the steam condenser effectiveness and the transferred heat flow is shown in Figure 2, and on the steam pressure and the efficacy of the steam condenser in Figure 3.

American Journal of Energy Research 15 The increase in water temperature at the inlet to the steam condenser causes an increase in the effectiveness, a decrease in the heat flow, and an increase in the steam pressure. the transferred heat flow is shown in Figure 6, and on the steam pressure and the efficacy of the steam condenser in Figure 7.,74 282 2.2. Change in the Mass Flow Rate of Steam Flowing from the LP Part of the Turbine to the Steam Condenser In the second case, the steam mass flow rate was changed from 7 kg/s to 15 kg/s, in 1kg/s increments. effectiveness,72,7,68,66,64 281 28 279 278 277 effectiveness,68,67,66,65,64,63,62,61,6 375 35 325 3 275 25 225 2 175,62,6 275 6 65 7 75 8 85 9 95 1 15 cooling water mass flow rate kg/s effectiveness Q Figure 6. Steam condenser effectiveness and the heat flow as a function of the cooling water mass flow rate,5 276,5,59 15 7 8 9 1 11 12 13 14 15 steam mass flow rate kg/s effectiveness Q Figure 4. Steam condenser effectiveness and the heat flow as a function of the steam mass flow rate,5,45 steam pressure bar,45,4,35,3,25,45,4,35,3,25 efficacy steam pressure bar,45,4,35,3,25,35,25,2,15 7 8 9 1 11 12 13 14 15 steam mass flow rate kg/s pressure efficacy Figure 5. Steam pressure and efficacy of the condenser as a function of the mass flow rate The temperature of cooling water at the inlet to the steam condenser and its mass flow rate were constant and equal to the nominal values. The influence of the change in the steam mass flow rate on the steam condenser effectiveness and the transferred heat flow is shown in Figure 4, and on the steam pressure and the efficacy of the steam condenser in Figure 5. The increase in the steam mass flow rate causes an increase in all the analysed variables: the steam condenser effectiveness, the transferred heat flow, and the steam pressure in the condenser. 2.3. Change in the cooling water mass flow rate In the third case, the cooling water mass flow rate was changed from 6, kg/s to 1,5 kg/s, in 5 kg/s increments. The cooling water temperature and the steam mass flow rate were constant and equal to the nominal values. The influence of the change in the cooling water mass flow rate on the steam condenser effectiveness and,4,3,2 efficacy,2,2 6 65 7 75 8 85 9 95 1 15 cooling water mass flow rate kg/s pressure efficacy Figure 7. Steam pressure and the efficacy of the steam condenser as a function of the cooling water mass flow rate The increase in the cooling water mass flow rate causes a decrease in the steam condenser effectiveness, an increase in the transferred heat flow, and a drop in the steam pressure in the condenser. From among the parameters analysed, the steam pressure in the condenser is the one that has the biggest impact on the performance (efficiency and power output) of the LP part of the steam turbine. With the increase in the steam pressure, which was observed in the first case (the cooling water temperature at the inlet to the condenser increasing) and the second case (the steam mass flow rate increasing), the actual enthalpy drop should decrease, because steam expands to a higher pressure. Due to the "shorter" expansion curve, less losses are generated, hence the efficiency of the LP part of the steam turbine should increase. The correctness of this thesis was verified based on actual data for the 2-MW power plant. 3. Steam condenser measured data On the basis of hourly average data obtained from a Distributed Control System (DCS) of a national power plant, an analysis of changes in the parameters of the system comprising the steam condenser and the LP part of the steam turbine was performed for two months: January and July. These two months were chosen due to a significant change in the cooling water temperature at the inlet to the steam condenser in winter and summer seasons.

16 American Journal of Energy Research Using these data, the effect of the increase in the cooling water temperature on the performance of the steam condenser and the LP part of the steam turbine was analysed. Figure 8 shows the range of changes in the cooling water temperature at the inlet to the steam condenser for January and July. The cooling water temperature varied between 9 and 14 C in January, and between 2 and 26 C in July. The average increase in water temperature at the inlet to the steam condenser for July, as compared to January, is about 1 C, which means considerable variation in the operating conditions of the steam condenser. With the increase in the cooling water temperature at the inlet to the steam condenser, an increase in the steam temperature (and the corresponding pressure) is observed (Figure 9). inlet cooling water temperature C 3 25 2 15 1 5 Figure 8. Change in the cooling water inlet temperature in January and July steam temperature C 55 5 45 4 35 3 25 2 15 1 5 Figure 9. Change in the steam temperature (pressure) in the condenser in January and July Following the increase in the steam temperature in the condenser, the steam in the LP part of the turbine expands to a higher pressure, so the enthalpy drop is smaller (Figure 1). At the same time, smaller losses are generated in particular groups of stages, resulting in an increase in the efficiency of the LP part of the turbine (Figure 11). With the increase in the steam pressure, the quality (dryness) of the steam is also increasing (Figure 12). The values of the efficiency of the LP part of the turbine, presented in Figure 11, are relatively high, perhaps because of the way of balancing the whole turbine set, according to which the balance of the LP part is a closure of the entire turbine. The influence of changes in the cooling water parameters (including the inlet temperature according to Figure 8) on the steam condenser effectiveness is shown in Figure 13. steam enthalpy drop kj/kg efficiency of the LP part of the turbine % steam quality 5 45 4 35 3 25 2 15 1 5 Figure 1. Steam enthalpy drop in the LP part of the turbine 1 95 9 85 8 75 7 January July Figure 11. Change in the efficiency of the LP part of the turbine,97,95,93,91,89,87,85 Figure 12. Change in the steam quality (dryness) at the outlet of the LP part of the turbine steam condenser effectiveness,9,8,7,6,5,4,3,2,1 Figure 13. Change in the steam condenser effectiveness due to the increase in the cooling water inlet temperature Figure 14 to Figure 16 present the changes in the performance of the steam condenser and the LP part of the turbine in the two periods. Figure 14 shows the change in the mass flow rate of steam flowing from the LP part to

American Journal of Energy Research 17 the steam condenser. The steam mass flow rate varied from 27 to 45 t/h, i.e. within 6 and 95% of the power range of the power plant. Figure 15 illustrates the change in the heat flow transferred in the condenser, and Figure 16 shows the change in the power of the LP part of the turbine, which varied from 3 to 55 MW. The nominal power of the LP part of the steam turbine is around 6 MW [1]. steam mass flow rate t/h 6 5 4 3 2 1 45 4 35 3 25 2 15 1 5 Figure 14. Change in the steam mass flow rate Figure 15. Change in the heat flow transferred in the steam condenser According to the analysis carried out based on the data from the steam condenser simulator, the increase in the cooling water inlet temperature should cause a decrease in the heat flow transferred in the steam condenser (Figure 2). In contrast, in Figure 15 an increase in the transferred heat flow is observed, which can be explained by a slight increase in the steam mass flow rate (Figure 14); this corresponds to the second case for the data obtained from the steam condenser simulator (Figure 4). The final result of the increase in the cooling water inlet temperature (Figure 8) is a decrease in the actual power of the LP part of the turbine (Figure 16). power of the LP part of the turbine MW 8 7 6 5 4 3 2 1 Figure 16. Change in the power of the LP part of the turbine The power of the LP part of the turbine is LP = p s LP (3) P m hη where: hs isentropic enthalpy drop, η LP efficiency of the LP part of steam turbine. By analysing the changes in the power of the LP part of the turbine (3), one can see that it mainly depends on the inlet and outlet parameters of the LP part of the turbine which are related to the working parameters of the steam condenser [18,19]. The steam pressure in the condenser is a function of the following parameters [15,16]: (, α, α, ), ( 1,, ) PLP = f m p p T ph ph = f Tc m w m p (4) where: pα, Tα inlet steam pressure and temperature to the LP part, of steam turbine. Assuming that the steam pressure and temperature at the inlet to the LP part of the turbine and the cooling water mass flow rate vary within a narrow range, one can finally write ( 1, ) PLP = f Tc m p (5) The power of the LP part of the turbine as a function of these two parameters with indicated trend lines is presented in Figure 17. The increase in the cooling water temperature at the inlet to the steam condenser of about 1 C causes a decrease of around 5 MW in the power of the LP part of the turbine. The power of the LP part of the steam turbine is a linear function of the steam mass flow rate [18,19], which is confirmed in Figure 17. Directional coefficients of the trend lines of the two months analysed, January and July, are similar in value, which implies that the power of the LP part of the turbine is also a linear function of the cooling water temperature at the inlet to the condenser. power of the LP part of the turbine MW 6 55 5 45 4 35 3 25 y =,1333x - 3,377 y =,1195x - 2,4517 2 2 25 3 35 4 45 5 steam mass flow rate t/h inlet cooling water temperature - July inlet cooling water temperature - January Figure 17. Power of the LP part of the turbine as a function of the cooling water temperature at the inlet to the condenser and the steam mass flow rate Therefore, it is proposed to provide the power of the LP part of the turbine as a linear function with respect to the steam mass flow rate and the inlet cooling water temperature to the condenser in the form LP = 1 p + 2 c1+ 3 (6) P am at a The coefficients in the equation (6) were determined by means of the least squares method. A comparison between the power of the LP part of the turbine as obtained from DCS and calculated from the proposed equation (6) is

18 American Journal of Energy Research presented in Figure 18. Points in Figure 18 are arranged along a straight line y = x, which indicates a good accuracy and correctness of the proposed equation (6). power of the LP part of the turbine obtained from DCS 6 55 5 45 4 35 y = x + 4E-6 3 3 35 4 45 5 55 6 power of the LP part of the turbine calculated from the equation (6) Figure 18. Comparison between the power of the LP part of the turbine as obtained from DCS and calculated from the equation (6) 4. Conclusions The changes in water-side parameters affect the characteristic parameters which describe the condenser performance, such as the effectiveness, the transferred heat flow, and the steam pressure, which has a significant influence on the performance (efficiency and power) of the LP part of the turbine. Based on the data obtained from the steam condenser simulator, changes in the condenser effectiveness, the transferred heat flow, and the steam pressure in the condenser were analysed for three cases: for the change in the cooling water temperature at the inlet to the condenser, for the change in the cooling water mass flow rate, and for the change in the steam mass flow rate. The effect of these three parameters on the characteristic values that describe the steam condenser performance is presented in Table 1. With the increase in the steam condenser effectiveness, an increase in the steam pressure and a decrease in the power of the LP part of the turbine is observed. This is the case when the water temperature at the inlet to the condenser is increasing, and when the steam mass flow rate is increasing. With the increase in the steam temperature/pressure, we can see some positive effects, such as an increase in the efficiency of the LP part of the turbine (Figure 11), and an increase in the quality (dryness) of steam (Figure 12), but also strongly negative effects, such as a lower actual drop in the steam enthalpy (Figure 1) leading to the lower power of the LP part of the turbine (Figure 16). Thus, according to the authors, the steam condenser effectiveness is not a good parameter to describe the performance of the steam condenser nor the system comprising the steam condenser and the LP part of the turbine. Such a parameter, however, may be the proposed efficacy of the steam condenser δ whose increase means better vacuum (Table 1). Table 1. Effect of the change in the inlet cooling water temperature, and the steam and cooling water mass flow rates on the characteristic values describing the performance of the condenser Parameter Heat exchanger effectiveness ε Heat flow Q Pressure in the steam condenser p h Efficacy of the steam condenser δ=(1-ε) Tc1 m p m c Moreover, for practical purposes, the relation (6) was given for the power of the LP part of the steam turbine as a linear function of the cooling water mass flow rate and its temperature at the inlet to the steam condenser with three constant coefficients. References [1] Laudyn D., Pawlik M., Strzelczyk F.: Power plants (in Polish, WNT Warsaw 29). [2] Szkłowier G., Milman O.: Issledowanije i rasczot kondensacionnych ustrojstw parowych turbin (Energoatomizdat. Moskow 1985). [3] Rusowicz A.: Issues concerning mathematical modelling of power condensers (in Polish, Warsaw University of Technologies, 213) [4] Saari J., Kairko J., Vakkilainen E., Savolainen S.: Comparison of power plant steam condenser heat transfer models for on-line condition monitoring (Applied Thermal Engineering 62 pp 37-47, 214). [5] Smyk A.: The influence of thermodynamic parameters of a heat cogeneration system of the nuclear heat power plant on fuel saving in energy system (Warsaw University of Technologies, 1999). [6] Kostowski E.: Heat Transfer (in Polish, WPŚ Gliwice, 2). [7] Cengel Y.: Heat and mass transfer (McGraw-Hill, 27). [8] Salij A.: The impact of the quality and reliability of the steam condensers system on the operation conditions of power plant (Warsaw University of Technologies, 211). [9] Grzebielec A., Rusowicz A.: Thermal Resistance of Steam Condensation in Horizontal Tube Bundles (Journal of Power Technologies. Vol.91, No 1 pp.41-48, 211). [1] Chmielniak T., Trela M.: Diagnostics of New-Generation Thermal Power Plants (Gdańsk, 28). [11] Wróblewski W., Dykas S., Rulik S.: Selection of the cooling system configuration for an ultra-critical coal-fired power plant (3rd International Conference on Contemporary Problems of Thermal Engineering CPOTE, Gliwice, Poland, 212). [12] Haseli Y., Dincer I., Naterer G.: Optimum temperatures in a shell and tube condenser with respect to exergy (International Journal of Heat and Mass Transfer 51 pp 2462-247, 28). [13] Anozie A., Odejobi O.: The search for optimum condenser cooling water flow rate in a thermal power plant (Applied Thermal Engineering 31 pp 483-49, 211). [14] Gardzilewicz A., Błaszczyk A., Głuch J.: Economic and ecological aspects of cooling water control for large power steam turbines (in Polish, Archives of Energetics, Vol. XXXVIII nr 2, pp 83-95, 28). [15] Laskowski R., Lewandowski J.: Simplified and approximated relations of heat transfer effectiveness for a steam condenser (Journal of Power Technologies 92 (4) pp 258-265, 212). [16] Laskowski R., Smyk A.: Analysis of the working conditions of a steam condenser using measurements and an approximation model, (Energy Market 1 (11) pp 11-115, 214). [17] Krzyżanowski J., Głuch J.: Thermo-flow diagnostics of power plants (Gdańsk, 24). [18] Lewandowski J.: Issues of identification of steam turbines (Warsaw University of Technology, 199). [19] Miller A., Lewandowski J.: Operation of steam turbines in offdesign conditions (WPW Warsaw, 1992).