Measuring Recording Online Monitoring Regulation Alarming

Similar documents
Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dew point set DS 400

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Monitoring Solutions

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Cold chain monitoring technologies. Facility monitoring

Smart Wireless Sensor

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Instructions for use

Smart Wireless Sensor

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

RACK MONITORING SYSTEM RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra

SCAN200E USER S MANUAL

EasyLog Data Logger Series

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

EasyLog Data Logger Series

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

DATAssure. Laboratory wireless alarm & monitoring system

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

D3 Wireless temperature alarm & monitoring system family. tek-troniks

EC-BOS-602/616 AX Security

Laboratory Refrigerator/Deep Freezer TC 802

YOUR PARTNER IN FIRE & GAS DETECTION

ACTIVE INFRARED BARRIER

CAN unit for Analog Sensors

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

REMOTE MONITORING AND ALARM SYSTEM

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

Combined CAN Sensor Unit Temperature, Humidity and Smoke

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

Specification for On-Line UPS Battery Monitoring and Data Management System

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Security designed for your lifestyle

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Complete packages with Software and Controller

Process Alarm Solutions

Typical applications include the vibration detector. Detection of vibrations and shocks

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Ontech GSM 9040/50. Reference Manual English -1 -

Solution F2. Fire Alarm Control Panels one step ahead.

securityprobe SNMP-based Environmental and Security Monitoring Solution

graphic indication of the dew point curve/ the switching behavior of the dryer over a longer period of time.

OPTIMUM APPLIED SYSTEMS,

AK-CS On Board Guide

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

SENSAPHONE 901 Tryens Road Aston, PA PH:

THX-DL Data Logger USER & INSTALLATION MANUAL V

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

Data Logging Solutions

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Outdoor Temperature Sensor

AirFlow Sensor for Dry Contact connection

IceSpy System5. A big deal in the world of large scale environmental monitoring INDUSTRY SPECIFIC PRODUCT SOLUTIONS HEALTHCARE.

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Part of the Crop Monitoring and Automatic control range. The most advanced automatic fan control and crop monitoring system available

NU2 Smart Power Supply (SPS) Manual

AirTest Technologies Inc.

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

Chromatographic Air circulated Refrigerator, two-door TC 603

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

The new generation of cold room solutions. CAMAlarm Alarm Alarm

Security Alarm Systems

Lift Station Level Controller

Panel Mounted Fault Annunciator Series

MiNi Server environment MoNitoriNg SySteM

WEBs AX Security. Integrated Security With Simple, Web-Based Management

SMS GSM Alarm Messenger

M1000 Alarm Annunciator

Remote fiber testing to improve SLA s

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

HRX Technical Manual. Version 1.2

portable gas analyser

SC-F3G User Manual 1.0

The EN54 Part 2, 4 and 13 Fire System

HOBO U30 Remote Monitoring Systems

Flair 500 Series Annunciators

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

RS485 MODBUS Module 8AI

Our Extended Personal Electronic Dosimeter (PED) Family

Why Choose Sensaphone? What Is A Sensaphone? If you have something important at a remote site, then you need a SENSAPHONE to watch it for you.

Advanced FireAlarm Panel 1-4Loop

RAYCHEM NGC-30 COMPONENTS

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Parameterisable compact fault annunciator with permanent display

Transcription:

Measuring Recording Online Monitoring Regulation Alarming Temperature Humidity CO 2 Dew point Atmospheric pressure Analog signals Two-state inputs Pulses

Battery operated recorders and printers Economical Dataloggers accurate measurement of - events nonvolatile memory for 32 000 values indication of alarm conditions via e-mail, SMS or visually software Comet Vision 2.0 for data analysis built-in printer (for selected models) communication interfaces - USB, RS232, GSM modem rugged design with protection up to IP67 battery life up to 7 years Battery operated recorders Premium Dataloggers accurate measurement of - current (4 20 ma) - voltage (0 5 V, 0 10 V) - pulses - events nonvolatile memory for 500 000 records visual and accoustic indication of alarm easy to use software Comet Vision 2.0 for data analysis USB-C communication interface rugged design long battery life up to 6 years logger deployment down to -40 C 3

Battery operated GSM modem Mobile Dataloggers Two buttons keypad for device control. Replaceable antenna. Large display for easier readabilitycurrent value, MIN/MAX value; alarm indication. 3-colour LED for alarm. accurate measurement of - events nonvolatile memory for 500 000 records indication of alarm via text massage, 3-colour LEDs, speaker easy to use software Comet Vision 2.0 for data analysis communication interfaces - USB-C snd GSM modem rugged design long battery life up to 6 years logger deployment down to -20 C Internal T/RH sensor protected by teflon foil. Connector USB-C for simple connection and battery charging (SMS and CO2 loggers). Connectors for removable and interchangeable probes. 5

Handheld for measuring and recording Commeter Temperature and humidity probe. Inputs for up to two temperature probe Ni1000. Commeter with record - D0211 and D0221 can also measure together with Pt1000 probes. Temperature and humidity probe on a cable. USB port for easy connection to a PC (D series only). Measured values are displayed on a backlit display. The device can be set from the keypad. The measured values are stored in the internal nonvolatile memory for 16 000 records. measuring and recording (probes Pt1000, Ni1000) - atmospheric pressure accurate measurement of up to two probes version of the device with memory and without memory audible and visual indication alarm conditions analytical software Comet Vision 2.0 for data processing and configuration the possibility of setting through a keypad USB communication interface backlit display Built-in acoustic alarm. Battery is included. 7

Battery operated 16 input-channel datalogger with Ethernet interface Temperature/relative humidity probe DigiS/M. Multilogger Temperature/relative humidity probe DigiL/M on the cable. 4 inputs Alarm indication by LEDs or graphical display. Removable probe holder. Measured values are stored internally in non-volatile memory. Battery and mains power supply. Measured values are shown on the graphical screen with backlight option and the ability to change the size of displayed digits. Optional cable length 1, 2, 5, 10, 15 metres. The device can be set from the keypad. You can set a password to prevent unauthorized access to the device settings. up to 6 hardware inputs for measuring and recording, 16 virtual channels - atmospheric pressure - current 0-20 ma and voltage 0-10 V (-60 to 140 mv) - two-state events - pulses - CO2 memory for 1 million values indication of alarm conditions via - e-mail - SMS - integrated acoustic siren LEDs - stwo-state output to control other devices analytical software for data processing and configuration - Comet Vision 2.0 communication interfaces - USB, RS232 and Ethernet (SNMPv1 and XML) Internal atmospheric pressure and / or CO2 concentration sensors. Built-in audio alarm. To communicate with a PC and other systems, the device is equipped with a USB port (located on the side of the device), RS232 and Ethernet. - send an e-mail when an alarm state starts or ends - use DATALINK: display current values or download values from device memory to your PC - view current measured values using your web browser - third-party applications to read the actual measured values using universal protocols SNMPv1 and XML - send data to COMET DATABASE software which contains many useful tools for data analysis - graphs, tables, statistics, etc. 9

Variable 16 input-channel datalogger Monitoring system OUTPUT SIDE INPUT SIDE software configurable or modular inputs for sensors Pt and Ni - thermocouples and thermistors - voltage and current - two-state events - frequency and pulses - resistance - sensors with RS485 output memory for 500 000 records with automatic downloading to PC alarm indication via integrated siren, e-mail, SMS and two-state output to control other devices software for data analysis on PC communication interface USB, RS232, relays, RS485 (Modbus RTU), ETHERNET (Modbus TCP, SOAP, etc.) 11

Internet of things sensors IoT-operated by Sigfox network RED SU MEA A DAT MS ALAR ALARMS Comet database viewer for data displaying on multiple PC accurate measurement of - barometric pressure - events cheap wireless communication for long distances indication of alarm via SMS easy to use database software for data analysis on PC data storage in the Comet cloude rugged design long battery life up to 5 years ng ta displayi ser for da Web brow 13

Outputs 4-20 ma, 0-10 V, RS232, RS485 and relays Sensors and regulators Terminal for power and signal RS485/RS232 for more details please see electrical wiring below on the page. LED signalization - visualization of binary inputs is done by three LED diodes. Other two diodes signed as ALARM 1 and 2 show alarm state and relay status. accurate measurement of - atmospheric pressure - two-state events - CO2 industrial design with protection up to IP65 - integrated sensors - with external probe - duct mount design interior design ATEX design for potentially explosive atmospheres (zone 2) on selected models relays output 250Vac / 8A or 50 V on selected models Design - measuring elements can be integrated into the body of device or may be on the cable with lengths of up to four meters. External probe may be designed for pressure of 25 bar. Relay - the device is equipped with two relay outputs for alarming or controlling of external devices. It is possible to assign any input value to each relay, to set comparing limit, delay, hysteresis, acoustic alarm or change its status by means of Modbus communication protocol. Keypad - two output relays can be configurated by means of keypad. Then any input value can be assigned, set comparing limits, hysteresis, delay or audible alarm. Acoustic alarm triggered alarm can be deactivated by pressing ESC. This possibility can be disabled and the acoustic alarm is active for the duration alarm condition. Three binary inputs these inputs are not galvanic isolated, connection terminals +U are internally connected to the device power supply i.e. the +U terminals provide the same voltage level as power supply. 15

Sensors with Ethernet output Web Sensors Chart with historical value Remote controlling of relay via internet Current measured values and sensor settings can be accessed directly through the web interface from your web browser. Graphs of actual values can also be displayed through a Web browser. You can display up to one thousand measured values. Export measured value to file Web browser interface Current measured values are available on-line directly on a web browser from anywhere, all you need to do is enter the IP address. Alarms are indicated by a red field. accurate measurement of - humidex - atmospheric pressure - two-state events - CO2 communication protocols - SNMP - Modbus TCP - SOAP - XML webserver to display current and the recorded values alarm indication via e-mail PoE on selected models data analysis software Comet Database Recorded events Sensor settings can also be done directly in a web browser in your PC, smartphone or tablet. All you need to do is enter the IP address of the sensor, open Settings and set up everything from communication to alarm e-mails. Software development kit available for SNMPv1 protocol ModbusTCP protocol XML file values.xml SOAP protocol Syslog list 17

Analytic and configuration software COMET Vision 2.0 Storage place for all COMET devices COMET Database software download analyse present data print out reports Online display Device list and device panel Recorded data Compatible devices Graphs by channels all dataloggers without printer Commeter Multilogger One software for all COMET products 24 hours supervision unlimited data storage simple and clear access to your measured values single repository for all devices COMET alarm SMS texts and e-mails acoustic and visual signalization of alarms 19

Measuring Recording Online Monitoring Regulation Alarming COMET SYSTEM, s.r.o. Bezrucova 2901 756 61 Roznov pod Radhostem CZECH REPUBLIC Tel: +420-571653990 Fax: +420-571653993 E-mail: info@cometsystem.com www.cometsystem.com Catalogue COMET - Professional measuting equipment 02/2018