Energy Efficiency Business Rebates Natural Gas Catalog

Similar documents
Boilers and Water Heating Rebate Catalog Saving energy for a brighter future.

Energy Efficiency Business Rebates Product Catalog

SDG&E s Business Energy Solutions Program 2018 Product Catalog

2018 Midstream Lighting Product Catalog

2010 Home Energy-Efficiency Rebate Program

Multifamily Energy Efficiency Rebates Application Package

2018 Instant Lighting Rebates Product Catalog

Prescriptive Program Rebate Application

2019 BUSINESS REBATE GUIDE AND APPLICATION

Application Information

2013 REPOWER INCENTIVE GUIDE

Nicor Gas Energy Efficiency Program. Business Customer Offerings

COMMERCIAL Washington Incentives

Application and Terms and Conditions

Summary of 60-Day Notice: Heating Efficiency

Incentives Existing Multifamily Properties

Get Wise to ThermWise. An Insider s Guide to ThermWise Rebates

HEATING AND COOLING REBATES

HEATING AND COOLING REBATES

Residential Rebate Program Available to NYSEG and RG&E residential natural gas and electric customers.

HEATING AND COOLING REBATES

Save energy at home residential natural gas rebate form

SEE WHAT SAVING ENERGY AND MONEY CAN DO FOR YOUR BUSINESS.

2011 NATURAL GAS EFFICIENCY REBATE APPLICATION

HIGH-EFFICIENCY EQUIPMENT TECHNICAL SHEET

EXISTING MULTIFAMILY OREGON CASH INCENTIVES. Standard Incentives SAVE MONEY AND ENERGY NOW AND FOR YEARS TO COME.

Ozone Laundry Fundamentals. Special guest: DEL Clean Ozone Laundry Systems

PG&E 2014 Title 24 Extension Products Products were extended through July 1, 2014

2015 NATURAL GAS EFFICIENCY REBATE APPLICATION

RESIDENTIAL REBATE FORM

Pacific Gas and Electric Company Energy-Efficiency Rebates for Your Business. New Construction Catalog Saving energy for a brighter future

Prescriptive Rebate Application

Home Improvement Rebates

National Grid s Direct Install Program for Commercial Customers

Gaining Efficiencies Through Hot Water

Save energy at home residential natural gas rebate form

2018 Rebate Catalog and Application

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications

ENERGY STAR Program Requirements Product Specification for Commercial Water Heaters. Eligibility Criteria Version 1.0: Draft 1

Pacific Gas and Electric Company Energy-Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

SBEC Residential Energy Efficiency Rebate Programs for New Homes

HEATING NATURAL GAS FURNACES, BOILERS AND ECM FURNACE FANS 2018 IOWA FOR YOUR BUSINESS REBATE APPLICATION

Consumers Energy Business Solutions Program

Rebate Catalog. Save money on qualified Home Cooling Systems, Appliances and more. Read about rebates for your home and business at mid.

Food Service Technology Center

Solar Water Heating Basics for Homeowners

PROPOSED October 15, 2013

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

EXHIBIT 1. Washington Home Energy Savings

Audit Date: Auditor: Sarah Hayden Client Name: College of St Benedict Audit Phone:

Residential rebate application instructions

EXHIBIT 1. California Home Energy Savings Program Measures, Incentives, and Qualifications

2018 Rebate Catalog and Application

SBEC Residential Energy Efficiency 2019 Rebate Programs for Existing Homes

2019 Smart Energy Existing Homes Program Manual

Installation address City State ZIP. Complete all felds for each piece of equipment purchased and installed. Natural Gas Furnace Information I I

ThermWise Update. SWEEP Conference November 9, 2009

Pacific Gas and Electric Company Product Changes

Heating Efficiency Program COLORADO

SBEC Residential Energy Efficiency 2019 Rebate Programs for New Homes

LACLEDE ENERGY EFFICIENCY PROGRAMS

Food Service Technology Center

WATER HEATING PAGETTE

Pacific Gas and Electric Company Energy-Efficiency Rebates for Your Business. Heavy Industrial Rebate Catalog Saving energy for a brighter future

Consumer Rebate Program

Customer Name: (as it appears on account) Account Number: Service Address: Mailing Address: City: Zip: Phone Number: (

HEATING NATURAL GAS FURNACES, BOILERS AND ECM FURNACE FANS 2017 ILLINOIS FOR YOUR BUSINESS REBATE APPLICATION

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

Residential HVAC Program Guide WARMAdvantage & COOLAdvantage Programs. For Fiscal Year 2018 (7/1/2017 through 6/30/2018)

Solar Hot Water Heating Systems

Massachusetts COOL SMART

COMMERCIAL. Oregon Incentives

Heavy Industrial Rebate Catalog

REBATE. Ductless Mini-Split Heat Pump

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

2018 Agricultural Programs Rebate Application Federated Rural Electric, ATTN: Jon, P.O. Box 69, Jackson, MN 56143

Selecting a New Water Heater

Eligibility criteria

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

Minimizing the Cost Impact of Cap and Trade through Energy Efficiency. Jeff Blunt Energy Solutions Consultant - Enbridge Gas

Indoor Water Use SECTION 31 REGULATIONS AND CALGREEN CODE COMPLIANCE. Fixture & Appliance Requirements. Water Efficiency Review

Energize Connecticut Upstream Residential HVAC Program

2018 Program Manual. Lighting and Appliances Program Program Manual. Lighting and Appliances PREPARED BY:

Food Service Technology Center

Jefferson Cocke County Utility District Marketing Plan (July 1, 2008 through June 30, 2019) Revised effective July 01, 2016 A) Identify commercial

Lighting Catalog Energy Efficiency Rebates for Your Business

Insulate your exterior walls. Air seal and insulate your attic

M1200 Series Limited Warranty Dependability Promise

RESIDENTIAL HVAC & THERMOSTAT REBATES

DOWNLOAD OR READ : WATER GAS AND ELECTRIC LIGHT PLANTS UNDER PRIVATE AND MUNICIPAL OWNERSHIP PDF EBOOK EPUB MOBI

2018 Smart Energy Existing Homes Program Manual

Energy Upgrade California Home Upgrade Offered by The Energy Network

PART 5: HVAC & DHW SYSTEMS

2018 Commercial Lighting Retrofit Rebate Program

Clean Steam Generators

HERS Verified Single Dwelling Unit Hot Water System Distribution (Page 1 of 6)

Food Service Technology Center

ETG energysmart Program. Mary Patricia Keefe Vice President Regulatory Affairs

Residential Solar Water Heater

High Performance Building Guide 1

Transcription:

Energy Efficiency Business Rebates Natural Gas Catalog Solution Product Code Storage Water Heater G-A1 Storage Water Heater Natural Gas Products Product Description Units $/Unit Page # $2.00 3 Space Heating Boiler G-B1 Space Heating Boiler (Steam) $0.25 G-B2 Space Heating Boiler (Water) $0.25 3 G-B3 Space Heating Boiler (Large) $0.50 Commercial Boiler G-C1 Commercial Boiler $0.50 4 Instantaneous Water Heater Process Boiler Direct Contact Water Heater Instantaneous Water Heater, Small (less than or equal to 200 G-D1 MBtuh) MBtuh $2.00 G-D2 Instantaneous Water Heater, Large (greater than 200 MBtuh) $0.50 G-E1 Process Boiler (Steam) $0.50 G-E2 Process Boiler (Water) $0.50 G-G1 Direct Contact Water Heater, greater than 300 MBtuh $2.00 G-G2 Direct Contact Water Heater, less than or equal to 300 MBtuh $2.00 4 5 6 G-H11 Pipe Insulation Low Pressure (less than or equal to 15 psi) Steam Application less than 1 in $3.00 G-H21 Pipe Insulation Low Pressure (less than or equal to 15 psi) Steam Application greater than 1 in $3.00 Pipe Insulation Tank Insulation G-H31 Pipe Insulation Hot Water Application less than 1 in $3.00 Linear Foot G-H41 Pipe Insulation Hot Water Application greater than or equal 1 in $3.00 G-H51 G-H61 G-H71 G-I1 Pipe Insulation Medium Pressure (greater than 15 psi) Steam Application less than 1 in $4.00 Pipe Insulation Medium Pressure (greater than 15 psi) Steam Application greater than or equal to 1 in $4.00 Pipe Insulation High Pressure (greater than or equal to psi) Dry Cleaner Steam Application greater than or equal to 1 in $4.00 Tank Insulation High Temperature Application 1 in Square Foot $3.00 G-I2 Tank Insulation High Temperature Application 2 in $4.00 G-I3 Tank Insulation Low Temperature Application 1 in $2.00 G-I4 Tank Insulation Low Temperature Application 2 in $3.00 6 7 Residential Clothes Washer Steam Trap G-J1 High Efficiency Clothes Washer, CEE Tier 2 and 3A Models 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners 09162014 Page 1 Unit $35.00 G-J2 High Efficiency Clothes Washer, CEE Tier 3B Models $75.00 G-M1 Steam Trap Replacement, Large Commercial operating system 12-24 hrs./day Dry cleaners, Agricultural and Industrial accounts excluded $115.00 Ozone Laundry G-N11 Ozone Laundry System lb. $39.00 8 7 8

GENERAL REQUIREMENTS Customer must have a SDG&E commercial gas account if applying for a gas measure Everything must be installed and operational before a rebate application is submitted All rebates apply toward the purchase of new or replacement energy-efficient equipment, unless otherwise indicated. Used or rebuilt equipment is not eligible If you are uncertain whether equipment qualifies, contact a utility representative. The California Energy Commission (CEC) and/or Gas Appliance Manufacturers Association (GAMA) equipment efficiency listed ratings prevail over all submitted technical documentation, unless otherwise approved DEFINITIONS: Annual Fuel Utilization Efficiency (AFUE) Is the ratio of annual output energy to annual input energy Bubble Diffusion A method of inserting ozone into water by continuously bubbling ozone directly into the sump of the washer throughout the wash cycle Combustion Efficiency (CE) 100 times (1 - energy lost to flue) divided by input energy MBtuh 1,000 Btuh Thermal Efficiency (TE) 100 times useful energy output divided by input energy Total Washer Capacity Refers to rated capacity of installed and operating washing machine units that will be connected to the ozone laundry system(s) Venturi Injection A method of inserting ozone into water using very high pressure directly into the cold water supply line leading to the washer 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 2

Storage Water Heater Water heaters must meet efficiency requirements based on size, as shown in Table below. Equipment used for pools and spas does not qualify If the size and efficiency are not shown on the invoice, you must include a manufacturer s specification sheet documenting these characteristics Storage Water Heater Efficiency Requirements Table Input Rating Required Efficiency Less than or equal to 75,000 Btuh Energy Factor greater than or equal to 67% Greater than 75,000 Btuh Thermal Efficiency greater than or equal to 84% Storage Water Heater Table Product Code Description Rebate/Unit G-A1 Storage Water Heater $2.00/MBtuh Space Heating Boiler Boilers must meet efficiency requirements based on size and type as shown in Table below, Include a manufacturer s specification sheet documenting these characteristics. Equipment used for pools and spas does not qualify Boiler must be used for space heating for human comfort as defined by California Titles 20 & 24 standards In order to comply with SB 454, Must use a licensed contractor, as appropriate, and follow applicable permitting requirements for this installation. Ensure you have completed both the customer certification and the contractor certification in section 10 of the Energy Efficiency Business application for this HVAC related product Space Heating Boiler Table Product Code Type Input Rating Required Efficiency Rebate/Unit G-B1 Steam Less than 300 MBtuh Greater than or equal to 82% AFUE $0.25/MBtuh G-B2 Small Water Less than 300 MBtuh Greater than or equal to 84% AFUE $0.25/MBtuh G-B3 Large Greater than or equal to 300 MBtuh Greater than or equal to 85% Combustion Efficiency $0.50/MBtuh 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 3

Commercial Boiler (non-space Conditioning/non-Process Related) Only boilers > 75,000 Btuh qualify Must meet a minimum thermal efficiency of 84% Must Include a manufacturer s specification sheet documenting these characteristics Exclusions: Boiler must not be used for space conditioning for human comfort Boiler must not be used for industrial (process) end-use Equipment used for pools and spas does not qualify Industrial customers do not qualify Commercial Boiler (non-space Conditioning/non-Process Related) Table Product Code Description Rebate/Unit G-C1 Commercial Boiler $0.50/MBtuh Instantaneous (Tankless) Water Heater Water heaters must meet efficiency requirements based on size shown in Table below Only instantaneous water heaters (as defined by the California Energy Commission Title 20 & 24 standards) used for non-process hot water applications qualifies The manufacturer name and equipment model number must be provided Must provide proof of the tankless nature of the water heater (e.g., manufacturer equipment specification sheets) Instantaneous (Tankless) Water Heater Table Product Code Description Technical & Size Requirements Rebate/Unit G-D1 G-D2 Small Instantaneous Hot Water Heater Large Instantaneous Hot Water Heater Less than or equal to 200 MBtuh Energy Factor greater than or equal to 82% Greater than 200 MBtuh Thermal Efficiency greater than or equal to 82% $2.00/MBtuh $0.50/MBtuh 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 4

Process Boiler Manufacturing - involves the mechanical or chemical transformation of materials or substances into a new product which is neither a structure nor any other fixed improvement. Available to industrial end-use customers who manufacture a sellable product only (NAICS codes 31-33). Boilers primarily used for domestic hot water, space conditioning, pool or spa use do not qualify Boilers must meet efficiency requirements as shown in Table below The manufacturer name and equipment model number must be provided A flue gas analysis measured under full load conditions is required to document combustion efficiency after installation is complete Process Boiler Table Product Code Description Sub Category Size Category (input) <300,000 Btu/h Minimum Efficiency b,c 82% AFUE Rebate/Unit G-E1 Steam Process Boiler Gas-Fired 300,000 Btu/h and 2,500,000 Btu/h d 80%E t $0.50/MBtuh >2,500,000 Btu/h e 82%E c Gas-Fired <300,000 Btu/h 80% AFUE G-E2 Water Process Boiler Gas-Fired all, except natural draft Gas-Fired, natural draft 300,000 Btu/h and 2,500,000 Btu/h d 79%E t >2,500,000 Btu/h e 79%E t 300,000 Btu/h and 2,500,000 Btu/h d 77%E t >2,500,000 Btu/h e 77%E t $0.50/MBtuh 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 5

Direct Contact Water Heater In direct contact water heater system designs, heat from a flame comes into direct contact with small droplets of cold water which run through a stainless steel heat exchange media Only direct contact water heaters for process end-uses qualify (NAICS codes 31-33). Water heater primarily used for domestic hot water, space conditioning, pool or spa use do not qualify Boilers must meet efficiency requirements as shown in Table below Direct Contact Water Heater Table Product Code Required Efficiency Rebate/Unit G-G1 Greater than 300 MBtuh Greater than or equal to 90% Thermal Efficiency $2.00/MBtuh G-G2 Less than or equal to 300 MBtuh Greater than or equal to 88% AFUE $2.00/MBtuh Pipe Insulation (Non-space Conditioning) 1 or 2 of fiberglass, foam, or calcium silicate insulation must be added to existing nonresidential bare pipe systems which transfer fluid directly from gas-fired equipment The bare pipe diameter must be at least 1/2 inch Minimum insulation must be 1 to qualify Must submit manufacturer s name and insulation material type Must also provide proof of insulating values (e.g. Manufacturer s specification sheets) Exclusions: New pipe system replacement does not qualify Fuel switching application does not qualify Pipe Insulation (Non-Space Conditioning) Table Product Code Description & Technical Requirements Rebate/Unit G-H1 Pipe diameter less than 1"; Low pressure (less than or equal to 15 psi) Steam $3.00/Linear Foot G-H21 Pipe diameter more than or equal to 1"; Low pressure (less than or equal to 15 psi) Steam $3.00/Linear Foot G-H31 Pipe diameter less than 1"; Hot Water $3.00/Linear Foot G-H41 Pipe diameter greater than or equal to 1"; Hot Water $3.00/Linear Foot G-H51 Pipe diameter less than 1"; Medium pressure (greater than 15 psi) Steam $4.00/Linear Foot G-H61 Pipe diameter greater than or equal to 1"; Medium pressure (greater than 15 psi) Steam $4.00/Linear Foot G-H71 Pipe diameter greater than or equal to 1"; High pressure (greater than or equal to 15 psi) Steam (FOR CLEANER APPLICATION USE ONLY NAICS CODE 812320 $4.00/Linear Foot 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 6

Tank Insulation High temperature application: 170 200 degrees F solution; Low temperature application: 120 170 degrees F solution 1 or 2 of fiber glass or foam insulation must be added to existing bare liquid or solution storage or transfer tanks Tanks must be coupled to gas-fired commercial or industrial equipment that transfers heat to the liquid or solution Must provide the manufacturer s name and insulation material type Tank Insulation Table Product Code Description & Technical Requirements Rebate/Unit G-I1 Tank Insulation High Temperature (171 to 200 degrees F solution) 1" thick $3.00/square Foot G-I2 Tank Insulation High Temperature (171 to 200 degrees F solution) 2" thick $4.00/square Foot G-I3 Tank Insulation Low Temperature (120 to 170 degrees F solution) 1" thick $2.00/square foot G-I4 Tank Insulation Low Temperature (120 to 170 degrees F solution) 2" thick $3.00/square Foot Residential High Efficiency Clothes-washer Modified Energy Factor (MEF) - measures energy consumption of the total laundry cycle (washing and drying). It indicates how many cubic feet of laundry can be washed and dried with one kwh of electricity; the higher the number, the greater the efficiency. Water Factor (WF) - represents the number of gallons of water needed for each cubic foot of laundry. The lower number indicates lower consumption and more efficient use of water. Rebate is for a high-efficiency residential washer used at a business for onsite/in-house laundry. Commercial coin operated equipment does not qualify Must have either natural gas or electricity distributed to the installation address by SDG&E Qualifying clothes washers must have specific Modified Energy Factors (MEF) and Water Factors (WF) based on levels listed below Qualifying Level 1 residential clothes washers may be viewed at http://www.cee1.org/resid/seha/rwsh/rwsh-prod.pdf, Tier 2 and 3A Qualifying Level 2 residential clothes washers may be viewed at http://www.cee1.org/resid/seha/rwsh/rwshprod.pdf, Tier 3B Residential High Efficiency Clothes Washer Table Product Code Description & Technical Requirements Rebate/Unit G-J1 High Efficiency Clothes Washer, CEE Tier 2 and 3A models only MEF of 2.0 or greater and a WF of 6.0 or less $35.00/Unit G-I2 High Efficiency Clothes Washer, CEE Tier 3B models only MEF of 2.2 or greater and a WF of 4.5 or less $75.00/Unit 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 7

Steam Traps Must be a commercial facility that operates 12 hours or more. New construction is not eligible Steam traps must replace one-to-one an existing failed or older steam traps that have been in service for a minimum of five years For each steam trap being replaced must provide steam trap manufacturer, model number, specification sheet, paid purchase receipt with tax and proof of shipping Must provide operating pressure of steam system, and construction style (mechanical, thermostatic, or thermodynamic) May be asked to verify the location of the replaced steam trap(s) in steam loop Steam Traps Table Product Code Description & Technical Requirements Rebate/Unit G-M1 Large Commercial operating system 12-24 hrs./day Dry cleaners excluded Not available for Industrial and Agricultural Applications. $115.00/Unit Ozone Laundry System Must have a natural gas-fired boiler or natural gas water heater that supplies hot water to the on-premise laundry equipment This incentive only applies to hotels/motels with fewer than 250 guest rooms OR fitness and recreational sports centers that have on-premise laundry operations The ozone laundry system(s) must be a new purchased product and added-on to a new or existing commercial washing machine(s) The ozone laundry system(s) must transfer ozone into the water through Venturi Injection OR Bubble Diffusion. For hotel customers: The total number of guest rooms must be provided on the invoice Include a manufacturer s specification sheet documenting manufacturer name, equipment model, and ozone laundry system s serial number(s) Must provide total washer capacity in pounds for operating washer units with ozone laundry system(s) connected Additional Details: Hotels/motels with 250 guest rooms or more and other types of facilities may be considered under our Energy Efficiency Business Incentives Ozone Laundry System Table Product Code Description Rebate/Unit $39.00/lb. G-N1 Ozone Laundry System Washing Machine Capacity (Connected to Ozone Laundry System) 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 8

The selection, purchase, and ownership of goods and services are the sole responsibility of the customer. SDG&E makes no representations as to the safety, reliability, and/or efficiency of goods and services selected. SDG&E makes no warranty, whether express or implied, including warranty of merchantability or fitness for any particular purpose, use or application of selected goods and services. The program is funded by California utility customers and administered by SDG&E under the auspices of the California Public Utilities Commission (CPUC). Program funds will be made on a first- come, first-served basis until program funds are no longer available. This program may be modified or terminated without prior notice. The selection, purchase and ownership of goods and services are the sole responsibility of the customer. The web site links contained herein are provided for information purposes only. SDG&E does not endorse these web sites, or any goods or services ofoffered thereon. Particularly, SDG&E has not verified the privacy policies applicable to these web sites, or determined what actions will be taken by third parties regarding the privacy of visitors. In no event shall SDG&E be responsible for any third party web site policies or actions. 2013 San Diego Gas & Electric Company. All copyright and trademark rights reserved. Trademarks are property of their respective owners. 09162014 Page 9