CONTENTS. Product Specification..1 Refrigeration Diagram.. 3 Wiring Diagram.6 Troubleshooting Guide...9

Similar documents
KSIA SERIES SPLIT TYPE ROOM AIR CONDITIONER. For Split Wall Mounted Series R410a Inverter Model Type For F

Technical Manual of AUX Air Conditioner CONTENTS. Product Specification...1. Refrigeration Diagram...3. Introductions of Installation.

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING

KSIM20912-H216 KSIM30912-H216 KSIM40912-H216

Mobile Type Air Conditioner

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SERVICE MANUAL PORTABLE AIR CONDITIONER WAP-237EB NEW WIDETECH V 50Hz

Fast Track Troubleshooting

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

SERVICE MANUAL PORTABLE AIR CONDITIONER PAC-10000DB NEW WIDETECH V 50Hz

Fast Track Troubleshooting

Service manual. MIV V4+ Mini

Fast Track Troubleshooting

Fast Track Troubleshooting

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

PC20-AMFII / PC40-AMF USER MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SPLIT TYPE AC AND MULTI SPLIT AC SERVICE MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTALLATION INSTRUCTIONS R 410A

ACCESSORIES INCLUDED

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

USER MANUAL TPS-M5/M55/M555

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Fast Track Troubleshooting

Service Manual. Contents. 1.Important Notice Technical Specification Operation Details Wiring Diagram...

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Automatic Ice Maker. Service Manual VT ICEMAKER 15

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Fast Track Troubleshooting

Note: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

DEHUMIDIFIER INSTRUCTION MANUAL

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

MeacoCool MC Series Portable Air Conditioner

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Owner's Manual TABLE OF CONTENTS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

MODEL: DC10RCDH / DC12RCDH

PORTABLE AIR CONDITIONER

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Ducted inverter reverse cycle air conditioning

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Fast Track Troubleshooting

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Portable Air Conditioner. Instruction Manual

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Troubleshooting & Reference

Local Air Conditioner

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

OWNER S MANUAL VMH 09/12/18/24

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

Container Refrigeration

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Portable Air Conditioner Instruction Manual

BTU Units WORKING PROGRAM MANUAL

Inverter Split-type Room Air Conditioner

Owner's Manual TABLE OF CONTENTS

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

P O R T A B L E Air Conditioner

Otherwise, you can continue reading the file on the following pages.

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Ductless Split Air Conditioner

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Installation Instructions

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

5) Do not start or stop the unit by inserting or pulling out the power plug.

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

KMIR218-H221 / KMIR327-H217 / KMIR436-H217 / KMIR545-H219

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

Transcription:

E E e i e M nu l I OO I O I IO or it ount d ri In rt r od or I I I O I I I O I I I O I I I O le se Please read e this t is owner o ne s manual s m nu l carefully e ull and n t o ou l thoroughly before e o e operating o e tin the unit! t e unit T e Take care e of o this t is manual m nu l for future o utu e reference. e e en e.

CONTENTS Product Specification..1 Refrigeration Diagram.. 3 Wiring Diagram.6 Troubleshooting Guide...9

1.2 Outline Dimensions Indoor Unit H D W MODEL W in D in H in 9000BTU 12000BTU 18000BTU 24000BTU 29.5 29.5 35.4 30.6 10 10 12.2 9.3 7.9 7.9 10 8.8 Outdoor Unit H D W MODEL W in D in H in 9000BTU 12000BTU 18000BTU 24000BTU 28.3 28.3 22.7 31.5 10.2 10.2 11.7 11.8 21.3 21.3 21 27.2 3

Chapter 2 Refrigeration Diagrams 2.1 Cooling Only Cooling Mode Cooling Cycle Indoor heat exchanger (Evaporation) Steam-gas of low pressure Compressor (Compression) Liquid of low pressure (also a little gas) Gas of high pressure & temperature Capillary (Throttling) Super cooled liquid of high pressure Outdoor heat exchanger (Condensation) 4

2.2 Cooling & Heating Cooling Mode Cooling Cycle Indoor heat exchanger (Evaporation) Steam-gas of low pressure Compressor (Compression) Liquid of low pressure (also a little gas) Capillary (Throttling) Super cooled liquid of high pressure 4-way valve (Heat pump only) Gas of high pressure & temperature Outdoor heat exchanger (Condensation) 5

Heating Mode Heating Cycle Indoor heat exchanger (Condensation) Gas of high Pressure & temperature Compressor (Compression) Super cooled liquid of low pressure 4-way valve (Heat pump only) Capillary (Throttling) Super cooled liquid of high pressure Steam-gas of low pressure Outdoor heat exchanger (Evaporation) 6

Chapter 3 Wiring Diagram Indoor unit Electric chart for 09/12/18/24K 7

Outdoor unit Electric chart for 09/12/18K 8

Outdoor unit Electric chart for 24K 9

Chapter 4 Troubleshooting Guide 4.1 Error Code No. Error Code Problem 1 E1 Room temperature sensor fault 2 E2 Outdoor coil temperature sensor fault 3 E3 Indoor coil temperature sensor fault 4 E4 Indoor fan motor or DC motor feedback fault 5 E5 Indoor & outdoor communication fault 6 F0 Outdoor DC Fan motor fault 7 F1 IPM modular fault 8 F2 PFC modular fault 9 F3 Compressor operation fault 10 F4 Exhaust Temperature sensor fault 11 F5 Compressor top cover protection 12 F6 Outdoor ambient temp sensor fault 13 F7 Over/under voltage protection 14 F8 Outdoor modular communication fault 15 F9 Outdoor E²PROM fault 16 FA Suction temperature sensor fault (4-way valve swich failure) 10

4.2 Troubleshooting Guide 1. The Foremost Inspecting Items ⑴The input voltage must be within +10% tolerance of the rated Voltage. If it is not the case, the air-conditioner will probably not work normally. ⑵Check the connecting cord between indoor unit and outdoor unit to see if it is properly connected. The connecting must be done according to the wiring diagram, please also notice that even different models may have the connecting cord of the same specification. Please check if the marks at the connecting terminal and the marks on the cord can match, otherwise, the air-conditioner will not work normally. ⑶If the following phenomena are found, the problem is not from the air-conditioner itself. 11

NO. Problems Causes 1 2 3 4 5 The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature. The compressor works discontinuously at dehumidifying mode. The air-conditioner does not work while the LED display is on. The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down. Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received. If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set. The air-conditioner will automatically control the working of the compressor according to the inside temperature The TIMER is set with the air-conditioner; it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen. 12

2. No Power Display ⑴Items a) Check if the input voltage is correct? b) Check if the AC power supply connecting is correct? c) Check if the output voltage of the manostat L7805 (IC2) is correct? ⑵Trouble shooting procedure 13

3. The Indoor Fan Motor Does Not Work ⑴Items a) Check if the indoor fan motor is connected correctly to the connector (CN8)? b) Check if the AC input voltage is correct? c) Check if the IC of indoor fan motor is connected correctly to the connector (CN2)? d) Check if the capacity of indoor fan motor is connected correctly to the connector (CN8)? ⑵Trouble shooting procedure 14

4. The Outdoor Unit Does Not Work ⑴Items a) Check if the input voltage is correct? b) Check if the wire connection of the outdoor connecting terminal is correct? ⑵Trouble shooting procedure 15

5. The Step Motor Does Not Work ⑴Items a) Check if the input voltage is correct? b) Check if the step motor controlling the up-down movement firmly connected to Cn2? ⑵Trouble shooting procedure 16

6. Heating Mode Can Work, But No Hot Air Blow ⑴Check if the set temperature is lower than the indoor temperature? ⑵Check if the indoor PCB is connected to the terminal correctly? 17

7. Remote Control Can Not Work Trouble shooting rocedure 18

The Klimaire logo is a registered Trademark of Klimaire Products Inc. Copyright 2016 Klimaire Products Inc.