GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

Similar documents
GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

HELKAMA. Optical Fibre Cables

Duct Cable GYTS-144B1.3

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Ø 1000 * 588 mm 50 kg

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Fibre Optic Cable. Catalogue.

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Fiber Optic Distribution Cables (6-144 Fibers)

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Fibre Specification Standards

Fibre optic media options and trends

industry solutions: military

SPECIAL ELECTRICAL AND OPTICAL CABLES

Special Provision No. 683S28 December 2017

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Flame Retardant Overall Screened Instrumentation Cables (multicore)

DNVGL-CP-0402 Edition February 2016

FIRE RESISTANT CABLES

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

STANDARD CONFORMANCE

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Caledonian Flame Retardant Coaxial Cables

Fiber Optics for Todays Industry Applications

Compact Module. Category 6A FTP Cabling System 1.1

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Fibre (TIA) Field Test Specification

High Performance LSZH Fire Resistant Cable

Catalogue Telecommunication Cables INTRODUCCIÓN

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

CATEGORY 6A FTP RJ45 SOLUTION

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

fire resistant cables

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Fiber Optic Patch Cord and Pigtails

Detection of Solvents using a Distributed Fibre Optic Sensor

Introduction.

ENHANCED FIRE PERFORMANCE CABLE

Caledonian Fire resistant Coaxial Cables

Traction Cable Radox 3 GKW

PRODUCT CATALOGUE Norröna

Hands-On CAT 5/6 & Fiber Optic Installer

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

Basic Professional Fiber Optic Installation

MT-RJ Optical Fiber System Field Testing

Telecommunication Cables

FIRE PERFORMANCE CABLE

Photovoltaic Cables EN H1Z2Z2-K

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Clearlite Photonic Fibers

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Lloyd s Register Type Approval System Test Specification Number 3

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

This document is a preview generated by EVS

Fibre Optic Basics FIA Summer Seminar 2014

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Cable technology for highest safety requirements

Certified Fibre Optic Specialist - Testing

Product Catalogue. External Management

Multi-Core Fire Resistant Cable

Transcription:

GOF Indoor and Outdoor Cables Documentation VWL 064.504 Version 2.2 Source Code R

GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini- Breakout Central Loose Tube Stranded Loose Tube Central Loose Tube Stranded Loose Tube Central Loose Tube CST I-V(ZN)HH I-V(ZN=B)H I/A-DQ(ZN=B)H I/A-DQ(ZN=B)H A-DQ(ZN)B2Y A-DQ(ZN)B2Y A-D(ZN)W2Y Stranded Loose Tube CST A-DF(ZN) 2YW2Y Stranded Loose Tube ADSS A-DF(ZN) 2YQ(ZN)2Y Fiber count 2-24 2-24 2-24 12-216 2-24 12-216 2-24 6-96 6-96 General Outer sheath FireRes (LSZH) FireBur (LSZH) FireBur (LSZH) FireBur (LSZH) LLDPE MDPE MDPE MDPE HDPE Sheath color green green green green black black black black black Armouring Aramid Glass yarn Glass yarn Glass yarn Glass yarn Glass yarn Corrugated steel Corrugated steel Aramid Application Laying procedure Termination Rodent Protection - + + + ++ ++ +++ +++ - Tertiary cabling Building backbone Campus backbone WAN Trunking Ducts, Trays Building riser raised floor Empty tube Ducts Directly in the ground Blowing On site termination Splicing VARIOline VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

Colour code fibers Source code: R Fiber DIN VDE0888 Fiber colour 1 red 13 gelb w/mark per 70 mm 2 green 14 white w/mark per 70 mm 3 blue 15 grey w/mark per 70 mm 4 yellow 16 türquoise w/mark per 70 mm 5 white 17 orange w/mark per 70 mm 6 grey 18 pink w/mark per 70 mm 7 brown 19 gelb w/mark per 35 mm 8 violet 20 white w/mark per 35 mm 9 turquoise 21 grey w/mark per 35 mm 10 black 22 türquoise w/mark per 35 mm 11 orange 23 orange w/mark per 35 mm 12 pink 24 pink w/mark per 35 mm VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Installation Cables FO cable marking / 300306 R&Mfreenet <Sheath> <DIN> <n> x <m> <Fiber> <Category> <Spec> <Manf. Ref.> <source code> <Meter marking> Digit Description <Sheath> Outer sheath material <DIN> Cable type designation based on DIN VDE 0888 <n> <m> <Fiber> A = outdoor cable I = indoor cable V = 900µm tight buffer fibre D = loose tube with jelly filling Q = swelling tape / swell able glass yarn F = water blocked cable core Y = PVC Number of tubes if loose tube cable Number of fibers (per tube if loose tube) Fiber type ZN = glass yarn reinforcement B = non-metallic rodent protection 2Y = outer sheath PE H = outer sheath halogen free (LSZH) HH = halogen free breakout cable (LSZH) W = corrugated steel armouring 11Y = Polyurethane G50/125 = 50/125µm multimode fiber H200/230 = 200/2300 polymer cald fiber (PCF) G62.5/125 = 62.5/125µm multimode fiber P980/1000 = 980/1000 polymer optical fiber (POF) E9/125 = E9/125µm singlemode fiber <Category> Fiber category according ISO/IEC 11801:2002 <Spec> Source code <Manf. Ref.> <Meter marking> OM1 / OM2 / OM3 = multimode fiber OH1 = PCF OS1(G.652.D) = singlemode fiber OP1 = POF Single fiber specification according datasheet Manufacturer. The logic is: if MM (GOF) fibre Attenuation / window / bandwidth Example for OM3: 3.0B1500 1.0F500 Attenuation is 3.0dB/km @ 850nm and 1.0dB/km @1300nm bandwidth is 1500Mhz km @ 850nm and 500Mhz km @ 1300nm if SM fibre Attenuation / window / chrom. dispersion Example for OS1: 0.39F3 0.25H18 Attenuation is 0.39dB/km @ 1310nm and 0.25dB/km @1550nm Chrom. dispersion is 3ps/km nm @1310nm and 18ps/km nm @1550nm if PCF or POF Not applicable R for Draka Denmark Number index for the traceability Cable is produced with a meter marking VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Breakout Cables I- V (ZN) HH / D03-050714 Source code: R Indoor cables Fiber count 2-24 Enhanced fire resistance Number code for individual breakout identification Suitable for direct connector fitting UV stabilized LSZH sheath (color green) 900 µm tight buffered fibre Aramid yarn LSZH sheath Central strength member ø 2 mm Break out unit Wrapping Ripcord 1.1 mm FireRes sheath Fiber count 2 / 4 6 8 12 16 24 Nominal cable Ø (mm) 7.5 8.5 10 12.5 12 14.5 Nominal weight (kg/km) 60 90 100 145 150 170 Maximum tensile strength (N) during installation 900 1200 1600 2300 2000 3000 IEC 60794-1-2 E1 in operation 450 600 800 1150 1000 1500 IEC 60794-1-2 E1 Minimum bending radius (mm) during installation 75 100 100 150 140 175 IEC 60794-1-2 E11 in operation 130 150 150 250 240 280 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 1500 1500 1500 1500 1500 1500 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 20 up to plus 70 IEC 60794-1-2 F1 in operation minus 20 up to plus 70 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 870 1200 1500 2500 2500 3600 Properties in case of fire IEC 60332-1 IEC 60332-3C IEC 61034 IEC 60754-2 Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 2 R314458 R314465 R314472 R314479 4 R314459 R314466 R314473 R314480 6 R314460 R314467 R314474 R314481 8 R314239 R314240 R314241 R314248 12 R314242 R314243 R341244 R314249 16 R314463 R314470 R314477 R314484 24 R314245 R314246 R314247 R314250 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Mini Breakout Cables I- V (ZN=B) H / D12-050714 Source code: R Indoor cables Fiber count 2-24 Good fire resistance Glass yarn strength members Suitable for direct connector fitting UV stabilized LSZH sheath (color green) 900 µm tight buffer fibre Glass yarns FireBur sheath Fiber count 2 / 4 6 8 12 16 24 Nominal cable Ø (mm) 6 6 6 6.5 7.5 8.5 Nominal weight (kg/km) 30/35 40 50 55 60 90 Maximum tensile strength (N) during installation 1500 1500 1500 1500 2100 2400 IEC 60794-1-2 E1 in operation 500 500 500 500 700 800 IEC 60794-1-2 E1 Short time tensile strength (N) some days 1000 1000 1000 1000 1400 1600 IEC 60794-1-2 E1 Minimum bending radius (mm) during installation 50 50 50 75 75 115 IEC 60794-1-2 E11 in operation 100 100 100 130 130 230 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 3000 3000 3000 3000 3000 3000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 20 up to plus 70 IEC 60794-1-2 F1 in operation minus 20 up to plus 70 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 660 a) 845 970 1180 1400 1700 Impact (J (Nm)) 20 20 20 20 20 20 IEC 60794-1-2 E4 Torsion 5 cycles ± 1 turn IEC 60794-1-2 E7 Properties in case of fire IEC 60332-1 IEC 61034 IEC 60754-2 a) Heat of combustion with 4 Fibers is 760 MJ/km Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 2 R314486 R314488 R314490 R314492 4 R304081 R304073 R308315 R304135 6 R304082 R304074 R308316 R304136 8 R304083 R304075 R308313 R304137 12 R304084 304076 R308318 R304138 16 R314487 R314489 R314491 R314493 24 R304086 R304078 R308317 R304140 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Central Loose Tube Cables I/A- DQ (ZN=B) H / E14-051006 Source code: R Indoor as well as outdoor use Central loose tube with 2-24 fibers Individually color coded fibers for identification Slight rodent protection through reinforced glass yarn UV stabilized LSZH sheath (color green) Central Loose Tube Swell able Glass strength member 1.0 mm FireBur Sheath Fiber count 2 to 16 18 to 24 Nominal cable Ø (mm) 6.0 6.5 Nominal weight (kg/km) 40 45 Maximum tensile strength (N) during installation 1000 1000 IEC 60794-1-2 E1 in operation 500 500 IEC 60794-1-2 E1 Short time tensile strength (N) some days 750 750 IEC 60794-1-2 E1 Minimum bending radius (mm) loaded 100 100 IEC 60794-1-2 E11 unloaded 60 60 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 1500 1500 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 60 IEC 60794-1-2 F1 during installation minus 30 up to plus 40 IEC 60794-1-2 F1 in operation minus 30 up to plus 60 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 630 800 Impact (J (Nm)) 15 15 IEC 60794-1-2 E4 Torsion 5 cycles ± 1 turn IEC 60794-1-2 E7 Kink The cables do not form a kink when a IEC 60794-1-2 E10 loop is drawn together to a diameter of 100 mm Water penetration no water on free end IEC 60794-1-2 F5B Properties in case of fire IEC 60332-1 IEC 61034 IEC 60754-2 Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 R304093 R304088 R308217 R304143 6 R304094 R304089 R308310 R304145 8 R304095 R304090 R308218 R304146 12 R304096 R304091 R308214 R304147 24 R304097 R304092 R308215 R304148 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables I/A- DQ (ZN=B) H / N05-050720 Source code: R Indoor as well as outdoor use Fiber count 12-216 (stranded loose tube) Excellent mechanical properties Water tight thanks to swelling tape Slight rodent protection through reinforced glass yarn UV stabilized LSZH sheath (color green) Ripcord ø 2.5 mm FRP strength member ø 2.3 mm loose tubes with jelly filling Swelling tape Glass yarn reinforcement 1.5 mm green FireBur sheath Fiber count 12-72 84-96 108-120 132-216 Nominal cable Ø (mm) 11 ± 0.5 13 ± 0.5 14 ± 0.5 15.5 ± 0.5 Nominal weight (kg/km) 130 165 200 240 Maximum tensile strength (N) during installation > 4800 > 4800 > 4800 > 4800 IEC 60794-1-2 E1 in operation > 3400 > 3400 > 3400 > 3400 IEC 60794-1-2 E1 Minimum bending radius (mm) loaded 150 180 200 220 IEC 60794-1-2 E11 unloaded 150 180 200 220 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 3000 3000 3000 3000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 40 up to plus 70 IEC 60794-1-2 F1 in operation minus 40 up to plus 60 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 2000 2700 3500 4000 Impact (J (Nm)) 20 20 20 20 IEC 60794-1-2 E4 Torsion 5 cycles ± 1 turn IEC 60794-1-2 E7 Kink The cables do not form a kink when a IEC 60794-1-2 E10 loop is drawn together to a diameter 12 times the cable nominal diameter Water penetration no water on free end IEC 60794-1-2 F5B Properties in case of fire IEC 60332-1 IEC 61034 IEC 60754-2 Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 314494 314501 314507 314513 2 x 12 314495 314502 314508 314514 4 x 12 314497 314503 314509 314515 6 x 12 314498 314504 314510 314516 8 x 12 314499 314505 314511 314517 12 x 12 314500 314506 314512 314518 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Central Loose Tube Cables Rodent Protection A- DQ (ZN) B2Y / E08-051006 Source code: R Outdoor cables Central loose tube with 2-24 fibers Individually color coded fibers for identification Glass yarn rodent protection UV stabilized LLDPE sheath (color black) Central Loose Tube Swell able Glass fibre yarns 1.2 mm black LLDPE sheath Fiber count 2 to 16 18 to 24 Nominal cable Ø (mm) 6.5 7.0 Nominal weight (kg/km) 40 45 Maximum tensile strength (N) during installation 1500 1500 IEC 60794-1-2 E1 in operation 700 700 IEC 60794-1-2 E1 Short time tensile strength (N) some days 1000 1000 IEC 60794-1-2 E1 Minimum bending radius (mm) loaded 100 100 IEC 60794-1-2 E11 unloaded 60 60 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 2000 2000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 60 IEC 60794-1-2 F1 during installation minus 15 up to plus 40 IEC 60794-1-2 F1 in operation minus 30 up to plus 60 IEC 60794-1-2 F1 Impact (J (Nm)) 20 20 IEC 60794-1-2 E4 Torsion 5 cycles ± 1 turn IEC 60794-1-2 E7 Kink The cables do not form a kink when a IEC 60794-1-2 E10 loop is drawn together to a diameter of 200 mm Water penetration no water on free end IEC 60794-1-2 F5B Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 R314519 R314521 R314523 R314525 6 R312789 R312791 R312792 R312797 8 R314520 R314522 R314524 R314526 12 R304153 R304150 R311387 R304156 24 R304154 R304151 R311388 R304157 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables Rodent Protection A- DQ (ZN) B2Y / H08-041117 Source code: R Outdoor cables Fiber count 12-216 (stranded loose tube) Excellent mechanical properties Water tight thanks to swelling tape Glass yarn rodent protection UV stabilized MDPE sheath (color black) Ripcord ø 2.5 mm FRP strength member ø 2.3 mm loose tubes with jelly filling Swelling tape Glass yarn reinforcement 1.5 mm black MDPE sheath Fiber count 12-72 84-96 108-120 132-216 Nominal cable Ø (mm) 11 ± 0.5 13 ± 0.5 14 ± 0.5 15.5 ± 0.5 Nominal weight (kg/km) 120 155 185 220 Maximum tensile strength (N) during installation > 4800 > 4800 > 4800 > 4800 IEC 60794-1-2 E1 in operation > 3400 > 3400 > 3400 > 3400 IEC 60794-1-2 E1 Minimum bending radius (mm) loaded 150 180 200 220 IEC 60794-1-2 E11 unloaded 150 180 200 220 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 3000 3000 3000 3000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 60 IEC 60794-1-2 F1 during installation minus 40 up to plus 60 IEC 60794-1-2 F1 in operation minus 40 up to plus 60 IEC 60794-1-2 F1 Impact (J (Nm)) 20 20 20 20 IEC 60794-1-2 E4 Torsion 5 cycles ± 1 turn IEC 60794-1-2 E7 Kink The cables do not form a kink when a IEC 60794-1-2 E10 loop is drawn together to a diameter 12 times the cable nominal diameter Water penetration no water on free end IEC 60794-1-2 F5B Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 314527 314532 314537 314542 2 x 12 314528 314533 314538 314451 4 x 12 304155 304152 311389 304158 6 x 12 314529 314534 314539 314452 8 x 12 314530 314535 314540 314453 12 x 12 314531 314536 314541 314454 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Central Loose Tube Cables Steel-Armored A- D (ZN) W2Y / E06-050719 Source code: R Outdoor cable for application in harsh conditions Central loose tube with 2-24 fibers Individually color coded fibers for identification Reinforced rodent protection with corrugated steel CST UV stabilized MDPE sheath (color black) Fibres Central UNI tube Strength members 0.155 mm corrugated steel tape 1.5 mm black MDPE sheath Fiber count 2 to 16 18 to 24 Nominal cable Ø (mm) 8.5 9.5 Nominal weight (kg/km) 75 80 Maximum tensile strength (N) during installation 1000 1000 IEC 60794-1-2 E1 in operation 500 500 IEC 60794-1-2 E1 Minimum bending radius (mm) loaded 110 110 IEC 60794-1-2 E11 unloaded 55 55 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 2000 2000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 40 up to plus 70 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Impact (J (Nm)) 10 10 IEC 60794-1-2 E4 Torsion 5 cycles ± 1 turn IEC 60794-1-2 E7 Kink The cables do not form a kink when a loop is drawn together to a diameter of 100 mm IEC 60794-1-2 E10 Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 6 312796 312795 312794 312793 8 314455 314456 314457 314543 12 304213 304210 311390 304216 24 304214 304211 311391 304217 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables Steel-Armored A- DF (ZN) 2YW2Y / I07-050720 Source code: R Outdoor cable for direct ground installations Fiber count 6-96 (stranded loose tube) Water tight cable core Reinforced rodent protection with corrugated steel CST UV stabilized MDPE sheath (color black) ø 2.5 mm FRP strength member ø 2.3 mm loose tubes with jelly filling Jelly filling Polyester wrapping tape 1.3 mm black MDPE sheath Corrugated steel as rodent protection 1.5 mm black MDPE sheath Fiber count 8 to 72 84 to 96 Nominal cable Ø (mm) 14.5 16 Nominal weight (kg/km) 215 255 Maximum tensile strength (N) during installation 1800 1800 IEC 60794-1-2 E1 in operation 1200 1200 IEC 60794-1-2 E1 Minimum bending radius (mm) loaded 290 320 IEC 60794-1-2 E11 unloaded 290 320 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 3000 3000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 60 up to plus 60 IEC 60794-1-2 F1 during installation minus 30 up to plus 60 IEC 60794-1-2 F1 in operation minus 60 up to plus 70 IEC 60794-1-2 F1 Impact (J (Nm)) 20 20 IEC 60794-1-2 E4 Torsion 5 cycles ± 1 turn IEC 60794-1-2 E7 Kink The cables do not form a kink when a IEC 60794-1-2 E10 loop is drawn together to a diameter 12 times the cable nominal diameter Water penetration no water on free end (core only) IEC 60794-1-2 F5B Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 R314544 R314548 R314552 R314556 2 x 12 R314545 R314549 R314553 R314557 4 x 12 R304215 R304212 R311392 R304218 6 x 12 R314546 R314550 R314554 R314558 8 x 12 R314547 R314551 R314555 R314559 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables Aerial ADSS A- DF (ZN) 2Y Q (ZN) 2Y / O04A-020603 Source code: R Dielectric aerial cables ADSS Fiber count 6-96 (stranded loose tube) Water tight cable core Suitable for all standard span equipment High-voltage resistance of up to 132kV UV resistant HDPE sheath (color black) ø 3.0 mm FRP rod ø 2.8 mm loose tubes Jelly filling Polyester wrapping tape 1.3 mm black inner PE sheath Swelling tape Aramid strength member Black outer PE sheath Fiber count / loose tubes 4 to 72 / 6 4 to 96 / 8 Nominal cable Ø (mm) 16.5 18.5 Nominal weight (kg/km) 220 255 Maximum tensile strength (N) during installation 21000 21000 IEC 60794-1-2 E1 in operation 14500 14500 IEC 60794-1-2 E1 Cable breaking strength UTS (N) > 45000 > 45000 (IEC 60794-1-2 E1) Cable stiffness EA (kn) 1900 1900 (IEC 60794-1-2 E1) Minimum bending radius (mm) loaded 330 370 IEC 60794-1-2 E11 unloaded 330 370 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 3000 3000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 40 up to plus 70 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Impact (J (Nm)) 25 25 IEC 60794-1-2 E4 Torsion 1/m 5 times IEC 60794-1-2 E7 Coefficient of thermal expansion 6.2 x 10-6 7.9 x 10-6 Water penetration no water on free end IEC 60794-1-2 F5 Stringing example for 250 m span External loading for 250 m span and 2% (=5 m) initial sag Number of optical units in cable (Fiber count) Initial cable load without external load (N) Sag with external load (m) Cable load with external load (N) 90 km/h (25 m/s) wind load 6 ( 4 to 72) 3400 8.7 7500 8 (4 to 96) 3900 8.9 8300 180 km/h 50 m/s) wind load 6 ( 4 to 72) 3400 14.3 17900 a) 8 (4 to 96) 3900 14.8 19500 a) 1 kg/m ice load 6 ( 4 to 72) 3400 10.0 9500 8 (4 to 96) 3900 9.9 9800 2 kg/m ice load 6 ( 4 to 72) 3400 12.5 13900 8 (4 to 96) 3900 12.3 14300 a) The dynamic tensile strength may be used as maximum acceptable tension in this case Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 314560 314565 314570 314575 2 x 12 314561 314566 314571 314576 4 x 12 314562 314567 314572 314577 6 x 12 314563 314568 314573 314578 8 x 12 314564 314569 314574 314579 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Installation Cables Sheathing material / B05-030423 FireRes The FireRes sheathing material is a high performance state-of-the-art LSZH (Low Smoke Zero Halogen) material. The FireRes material is primary used where a very high resistance towards fire is needed. While the FireRes material implement improvements of Draka Comteq s well known multi purpose concept regarding performance in case of fire, the resistance towards the outdoor environment is retained: The FireRes material is UV resistant, and water resistant. The UV resistance is achieved using a selected type of hindered amine light stabilizer (HALS). Thus a long lifetime even in open air is assured. The FireRes material is non- toxic, non-corrosive and do not contain any halogens that could cause damage to equipment or the environments. Further in case of fire it generates only extremely low amount of smoke. The FireRes material fulfils all relevant international and national standards for this class of sheathing material, among them: EN 50290-2-27:2002 VDE 0207 part 24, type HM2 BS 7655 6.1 type LTS1 and LTS2 Cables made with our FireRes sheathing material is self-extinguishing and generally fulfils IEC 60332-3C. The FireRes material is used as part of the A.F.R. Technology to achieve fire resistance for PyroSafe cables. Typical properties Property Result Standard Density (kg/m 3 ) 1.6 ASTM D792 Tensile strength and elongation at break (MPa) Tensile strength: 11 Elongation: 170 % Tensile strength and elongation at break after ageing 7 days at 100 C (MPa) Change in tensile strength and elongation at break after 7 days at 23 C in ASTM oil no. 2 Change in tensile strength and elongation at break after 4 hours at 70 C in ASTM oil no. 2 (%) Change in tensile strength and elongation at break after 4 hours at 70 C in SAE 20 Oil (%) Change in tensile strength and elongation at break after 7 days at 23 C in Diesel (%) Tensile strength: 13 Elongation: 120 % Tensile strength: none Elongation: none Tensile strength: -20 Elongation: +10 Tensile strength: -25 Elongation: +15 Tensile strength: -35 Elongation: -20 IEC 60811-1-1 EN 60811-1-1 IEC 60811-1-2 EN 60811-1-2 IEC 60811-1-1-9 IEC 60811-1-1-9 IEC 60811-1-1-9 IEC 60811-1-1-9 Hot pressure at 80 C (%) 35 IEC 60811-3-1 Oxygen Index (%) 45 ISO 4589-2 Flammability temperature index ( C) 330 ISO 4589-3 Smoke density Pass IEC 61034 Halogen acid gas evolution None IEC 60754-1 Corrosively of gases (µs/cm) Pass: Conductivity 7.5 IEC 60754-2 (requirement < 100); PH = 5,5 (requirement ph > 3.5) Toxicity index 0.4 NES 713 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Installation Cables Sheathing material / B05-030423 FireBur The FireBur Low Smoke Zero Halogen material is produced from PE-copolymers and silicon elastomer with chalk as fire retardant filler. This sheathing compound is used for cables that are installed as indoor/outdoor cables, due to its very low water absorption. The cables made with this compound can be used outdoor installation in ducts (also flooded with water) as well as for direct burial. The FireBur sheathing material is UV stabilized using a selected type of hindered amine light stabilizer (HALS). Thus a long lifetime even in the open air is assured. Cables made with this material are self-extinguishing and fulfils IEC 60332-1. The material fulfils the requirements of: EN 50290-2-27:2002 VDE0207 part 24 (HM5) Typical properties Property Result Standard Density (kg/m 3 ) 1.2 ASTM D792 Tensile strength and elongation at break (MPa) Tensile strength: 11 Elongation: > 400 % IEC 60811-1-1 EN 60811-1-1 Water absorption after 10 days at 70 C (mg/cm 3 ) 0.11 IEC 60811-1-3 Flexural modulus (MPa) 205 ISO 178 Change in tensile strength and elongation at break after ageing 10 days at 100 C (%) UV and humility aging 240 days (20 hours UV light at 60 C and 4 hours damp heath at 50 C each day) (%) Acid and base resistance (28 days at 23 C) change at break: (%) HCL (37 %) NaCO 3 (ph 8) NH3 (10 %; PH 10 11) Acetic acid (20 %) Change in tensile strength and elongation at break after 4 hours at 70 C in ASTM oil no. 2 (%) Fluid resistance (24h at 49 C) change at break (%) Diesel Hydraulic oil Mil 5606 Fluid resistance (14 days at 23 C) change at break (%) Petrol Acetone Solvent resistance (14 days at 23 C) weight change (%) Iso Octane Kerosene, paraffin Ethanol Acetone 20 IEC 60811-1-2 EN 60811-1-2 Change in tensile strength: -9 Draka Change in elongation: -16 Tensile strength / Elongation -6 / -7-4 / -6-9 / -3-6 / -4 Tensile strength: -20 Elongation: -3 Tensile strength / Elongation -73 / -43-49 / -41 Tensile strength / Elongation -41 / -29-18 / -7 Small 10.5 1.0 3.0 IEC 60811--11-9 Hot pressure at 80 C (%) 25 IEC 60811-3-1 LOI (%) 32 BS 2782: Method 141:1986 Smoke density Pass IEC 61034 Smoke corrosively (µs/cm) Pass: Conductivity 1.5 IEC 60754-2 (requirement < 100); ph = 5.3 (requirement ph > 3.5) Heath of combustion (MJ/dm 3 ) 28 - Toxicity index 1.5 NES 713 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Installation Cables Sheathing material / B05-030423 LLDPE, black This is the alternative PE material for cables for outdoor use. The material is UV stabilised using 2.5 ± 0.5 % carbon black and have excellent weathering resistance. The LLDPE material is used for UNI tube cables and when specified according to customer request. The LDPE meets the requirements of a number of national and international standards: ISO 1872-PE, KCHL, 18 - D003 ANSI C 8.35 ASTM D1248-84: Type I, Class C, Cat 5, grade J3, E5 BS 6234 03C, TS1 DIN VDE 0207 type 2YM2 NF C 32-060 The LLDPE fulfils the requirements of IEC 708-1 (test according to IEC 811) MDDPE, black This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance. The MDPE has very good physical properties such as: Excellent abrasion resistance, high hardness, low dielectric constant and outstanding oxidation resistance. Compared with HDPE the MDPE has better resistance to stress cracking. Compared to LDPE the MDPE has a higher strength. The MDPE meets the requirements of a number of national and international standards: ISO 1872-PE, KGC, 40 - G200, C ASTM D1248-84: Type II, Class C, Cat 5 BS 6234 3C The MDPE fulfils the requirements of IEC 708-1 (test according to IEC 811) Corrugated steel tape armouring Corrugated steel tape armouring is used as rodent protection and as additional mechanical protection for outdoor cables for direct burial and for installation along railways and into sewers where the risk for rodent attack is high. Cables with corrugated steel tape and LDPE or HDPE jacket fulfils the requirements of: REA PE 90 (USA) As well as the requirements of several Railway administrations: Among them Banestyrelsen (Denmark), SNCF and RATP (France), BR (Great Britain). The steel tape is corrosion protected with a layer of chromium on both sides. The steel tape fulfils the requirements of: EN 10 202: 1989 ASTM A 657-87 The standard thickness of the steel tape is 0.155 mm ± 0.015 mm. Upon request tapes with a thickness of 0.250 mm may be supplied. There is a polymer film on both sides of the steel tape. The nominal thickness of the polymer film is 0.055 mm. The purpose of the polymer film is to ensure good adhesion between tape and outer (LDPE or MDPE) jacket and make the bonding of the overlap possible. The adhesion between steel tape and a polyethylene sheath is fulfilling the requirements of REA PE-90. A common trade name for this material is Zetabon. The steel tape is corrugated and folded over the cable core or an inner jacket. On top of the steel tape is extruded an outer polymer heath. Aramid yarns Aramid yarns are used as strength member for cables with tight buffered fibres, some cables with semi tight fibres and for UNI tube cable. Aramid yarns are also used in loose tube cables with central strength member as additional tensile reinforcement. There are no international or national standards for Aramid yarns. The most common trade names for Aramid yarns are Twaron and Kevlar. The tensile strength requirement for the cable determines the amount of Aramid yarn to be used. Glass yarns Glass yarns in the form of roving s are used as alternative strength member for UNI tube cables. Glass yarns are also used in loose tube cables with central strength member as additional tensile reinforcement. Thick layers of glaziers have appeared to be a good rodent protection scheme, however not as effective as steel armouring. VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Multi Mode Fiber 50/125 µm (OM3) / C12-060102 General information This fibre is a graded-index multimode fibre optimised for 10 Gb/s transmission speeds. It has a 50 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850, but can also be used at 1300 nm. The fibre is compliant with all relevant network standards. Range for 1000BASE SX: 1000 m Range for 10GBASE S: 300 m Specification Standards and norm Core Coating Optical properties Dimensional and mechanical properties This fibre fulfils the requirements of: IEC 60793-2-10; Category A1a.2; EN 60793-2-10; Category A1a.2; ITU Recommendation G.651 TIA/EIA-492AAAC Testing methods are in accordance with the following standards: IEC 60793-1-XX:2002 EN 60793-1-XX:2002 FOTP-220 (DMD) The core is germanium doped. When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN 50 173 :2002 category OM3. ISO/IEC 11801:2002 category OM3. IEEE 802.3 2002 with amendment 802.3ae 2002. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Bandwidth (OFL): At 850 nm: 3.0 db/km At 850 nm: 1500 MHz km At 1300 nm: 1.0 db/km At 1300 nm: 500 MHz km Fibre attenuation (for reference only) Effective Modal Bandwidth: At 850 nm: 2.5 db/km At 850 nm 2000 MHz km At 1300 nm: 0.7 db/km Numerical aperture: 0.200 ± 0.015. In homogeneity of OTDR trace for any two 1000 metre fibre lengths: Max.: 0.2 db/km. Note: Effective Modal Bandwidth is assured by means of differential mode delay (DMD) measurement as specified in IEC 60793-1-49. Group index of refraction: At 850 nm 1.482 At 1300 nm: 1.477 Core diameter (µm) 50 ± 2.5 IEC/EN 60793-1-20 Cladding diameter (µm) 125.0 ± 1.0 IEC/EN 60793-1-20 Cladding non-circularity (%) 1.0 IEC/EN 60793-1-20 Core non-circularity (%) 5 IEC/EN 60793-1-20 Core-cladding concentricity error (µm) 1.5 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 242 ± 7.0 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 10 IEC/EN 60793-1-21 Proof stress level (GPa) 0.7 ( 1 %) IEC/EN 60793-1-30 Typical average strip force (N) 1.7 IEC/EN 60793-1-32 Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN 60793-1-32 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Multi Mode Fiber 62.5/125 µm (OM1) / C02-060102 General information This fibre is a graded-index multimode fibre suitable for transmission speeds of up to 10 Gb/s. It has a 62.5 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850 and/or 1300 nm. This fibre is suitable for use in premises wiring application like LAN s with video, data and or voice services using LED, VCSEL and Fabry- Perot laser sources. The fibre is compliant with all relevant network standards. Specification Standards and norm Core Coating Optical properties This fibre fulfils the requirements of: IEC 60793-2-10 Category A1b; EN 60793-2-10: type A1b TIA/EIA-492AAAA Testing methods are in accordance with the following standards: IEC 60793-1-XX:2002 EN 60793-1-XX:2002 When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN 50 173:2002 category OM1. ISO/IEC 11801:2002 category OM1 IEEE 802.3-2002 with amendment 802.3ae - 2002. ANSI/TIA/EIA-568-B.3-2000 ANSI X3.166-1990 IEC 9314-3 IBM Fibre Optic Channel Links; ESCON The core is germanium doped. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Numerical aperture: 0.275 ± 0.015. At 850 nm: 3.2 db/km In homogeneity of OTDR trace for any two At 1300 nm: 1.0 db/km 1000 metre fibre lengths: Max.: 0.2 db/km. Bandwidth (OFL): At 850 nm: At 1300 nm: Dimensional and mechanical properties 200 MHz km 600 MHz km Group index of refraction: At 850 nm 1.496 At 1300 nm: 1.491 Core diameter (µm) 62.5 ± 2.5 IEC/EN 60793-1-20 Cladding diameter (µm) 125 ± 1.0 IEC/EN 60793-1-20 Cladding non-circularity (%) 1 IEC/EN 60793-1-20 Core non-circularity (%) 5 IEC/EN 60793-1-20 Core-cladding concentricity error (µm) 1.5 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 242 ± 7.0 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 10.0 IEC/EN 60793-1-21 Proof stress level (GPa) 0.7 ( 1 %) IEC/EN 60793-1-30 Typical average strip force (N) 1.7 IEC/EN 60793-1-32 Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN 60793-1-32 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Multi Mode Fiber 50/125 µm (OM2) / C01-060102 General information This fibre is a graded-index multimode fibre suitable for transmission speeds of up to 10 Gb/s. It has a 50 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850 and/or 1300 nm. This fibre is suitable for use in premises wiring application like LAN s with video, data and or voice services using LED, VCSEL and Fabry- Perot laser sources. The fibre is compliant with all relevant network standards. Specification Standards and norm Core Coating Optical properties This fibre fulfils the requirements of: IEC 60793-2-10 Category A1a; EN 60793-2-10: type A1a ITU Recommendation G.651 TIA/EIA-492AAAB Testing methods are in accordance with the following standards: IEC 60793-1-XX:2002 EN 60793-1-XX:2002 When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN 50 173:2002 category OM2. ISO/IEC 11801:2002 category OM2 IEEE 802.3-2002 with amendment 802.3ae - 2002. ANSI/TIA/EIA-568.B.3-2000 This fibre may be used as an alternative for 62.5 µm fibre according to: ANSI X3.166-1990 and IEC 9314-3 The core is germanium doped. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Numerical aperture: 0.200 ± 0.015 At 850 nm: 2.7 db/km In homogeneity of OTDR trace for any two At 1300 nm: 0.8 db/km 1000 metre fibre lengths: Max.: 0.2 db/km. Bandwidth (OFL): At 850 nm: At 1300 nm: Dimensional and mechanical properties 600 MHz km 1200 MHz km Group index of refraction: At 850 nm 1.482 At 1300 nm: 1.477 Core diameter (µm) 50 ± 2.5 IEC/EN 60793-1-20 Cladding diameter (µm) 125 ± 1.0 IEC/EN 60793-1-20 Cladding non-circularity (%) 1.0 IEC/EN 60793-1-20 Core non-circularity (%) 5 IEC/EN 60793-1-20 Core-cladding concentricity error (µm) 1.5 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 242 ± 0.7 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 10 IEC/EN 60793-1-21 Proof stress level (GPa) 0.7 ( 1 %) IEC/EN 60793-1-30 Typical average strip force (N) 1.7 IEC/EN 60793-1-32 Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN 60793-1-32 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Single Mode Fiber 9/125 µm (OS1, G.652.D) / C03e-060102 General information This enhanced Singlemode fibre provides improved performance across the entire 1260 nm to 1625 nm wavelength spectrum due to its low attenuation in 1383 nm the water-peak region. The fibre design is matched cladding. Specification Standards and norm Core Coating Optical properties Dimensional and mechanical properties This fibre fulfils the requirements of: IEC 60793-2-50 Category B.1.3 EN 60793-2-50: Class B1.3 ITU Recommendation G.652.D The older ITU designations A, B and C are also fulfilled. When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them is: EN 50 173-1: 2002, cat. OS1 + OS2 ISO/IEC 11801: 2002, cat. OS1 + OS2 IEEE 802.3-2002 incl. 802.3ae Testing methods are in accordance with the following standards: IEC 60793-1-XX: 2002 EN 60793-1-XX: 2002 The core is germanium doped. The fibre coating is dual layer UV curable acrylate. The fibre is coated using Draka Comteq s proprietary high quality coating systems. Attenuation (of cable with fibres): In the range 1310 nm - 1625 nm: 0.39 db/km At 1550 nm: 0.25 db/km In homogeneity of OTDR trace for any two 1000 metre fibre lengths Max.: 0.1 db/km Group index of refraction: At 1310 / 1550 / 1625 nm 1.467 Cladding diameter (µm) 125.0 ± 0.7 IEC/EN 60793-1-20 Cladding non-circularity (%) 0.7 IEC/EN 60793-1-20 Core (MFD) non-circularity (%) 6 IEC/EN 60793-1-20 Core (MDF) -cladding concentricity error (µm) 0.5 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 242 ± 7 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 12.0 IEC/EN 60793-1-21 Proof stress level (GPa) 0.7 ( 1 %) IEC/EN 60793-1-30 Strip force (peak) (N) 1.0 Fpeak.strip 8.9 IEC/EN 60793-1-32 Chromatic dispersion coefficient: In the interval 1285 nm 1330 nm (ps/km nm) At 1550 nm (ps/km nm) At 1625 nm (ps/km nm) Zero dispersion wavelength, λ 0 (nm) Zero dispersion slope (ps/(nm 2 km)) Cut-off wavelength (λ c nm) Cut-off wavelength (λ cc nm) Mode field diameter at 1310 nm (µm) Mode field diameter at 1550 nm (µm) Macrobending loss at 1550 nm, 100 turns on a ø 60 mm mandrel (db) 3 18.0 22.0 1312 ± 10 0.090 High limit: 1330 Low limit: 1150 1260 9.2 ± 0.4 10.3 ± 0.5 IEC/EN 60793-1-42 IEC/EN 60793-1-44 IEC/EN 60793-1-45 0.05 IEC/EN 60793-1-47 Polarisation mode dispersion (PMD) coefficient, cabled (ps/ km) 0.5 IEC/EN 60793-1-48 PMD Q Link Design Value (ps/ km) 0.2 IEC/EN 60794-3 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Cabling Standards ISO/IEC 11801:2002 Fiber optic categories The category defines the performance of a cabling component components to verify the compliance components to design a link/channel values for performance comparison Multimode fiber 850nm 1300nm category core - Ø db/km Mhz km launch db/km Mhz km launch OM1 50µm & 62.5µm 3.5 200 over filled 1.5 500 over filled OM2 50µm & 62.5µm 3.5 500 over filled 1.5 500 over filled 3.5 1500 over filled OM3 50µm 1.5 500 over filled 3.5 2000 restricted Singlemode fiber 1310nm 1550nm category core - Ø db/km Mhz km db/km Mhz km OS1 9µm 1.00 N.A 1.00 N.A Fiber optic classes The class defines end to end performance of a link its supporting cabling design of networking equipment values for certification of the installation Channel attenuation limits Class OF-300 channel supporting application over a min. length of 300m Class OF-500 channel supporting application over a min. length of 500m Class OF-2000 channel supporting application over a min. length of 2000m Note: Multimode Singlemode 850nm 1300nm 1310nm 1550nm 2.55dB 1.95dB 1.80dB 1.80dB 3.25dB 2.25dB 2.00dB 2.00dB 8.50dB 4.50dB 3.50dB 3.50dB The total values include 1.5dB for connecting hardware. Additional connectors and splices may be used if the power budget of the application allows. Models of vertical (backbone) and horizontal optical fiber cabling In order to accommodate increase quantities of mated connections and splices used within a channel of a given class, the total length of the channel may have to be reduced to accommodate the additional attenuation. Spliced combined Direct combined Patched combined VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Ethernet Applications Matrix ISO/IEC 11801:2002 / IEEE 802.3xx Applications according ISO/IEC 11801:2002 and EN 50173-1 (informative) Multimode Fast Ethernet 100Base-FX Gigabit Ethernet 1000Base-SX/LX 10Gbit Ethernet 10GBase-S 10Gbit Ethernet 10GBase-LX4 850nm 1300nm 850nm 1300nm 850nm 1300nm 850nm 1300nm OM1 N.A OF-2000 1) OF-500 N.A N.A N.A OF-300 OM2 N.A OF-2000 OF-500 OF-500 N.A N.A N.A OF-300 OM3 N.A OF-2000 OF-500 OF-500 OF-300 N.A N.A OF-300 Singlemode Gigabit Ethernet 1000Base-LX 10Gbit Ethernet 10GBase-LX4 10Gbit Ethernet 10GBase-L 10Gbit Ethernet 10GBase-E 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm OS1 OF-2000 N.A OF-2000 N.A OF-2000 N.A N.A OF-2000 1) Maximum Length (Channel) according IEEE 802.3z (275m) Standardized applications according IEEE 802.3xx 62.5/125 (OM1) 50/125 (OM2) 50/125 (OM3) Note: 9/125 (OS1) Multimode Fast Ethernet 100Base-FX Gigabit Ethernet 1000Base-SX/LX 10Gbit Ethernet 10GBase-S 10Gbit Ethernet 10GBase-LX4 850nm 1300nm 850nm 1300nm 850nm 1300nm 850nm 1300nm Max. Length (m) N.A 2 000 275 550 33 N.A N.A 300 Max. IL (db) N.A 11.0 2.53 2.32 1.6 N.A N.A 2.0 Max. Length (m) N.A 2 000 550 550 82 N.A N.A 300 Max. IL (db) N.A 6 3.43 2.32 1.8 N.A N.A 2.0 Max. Length (m) N.A 2 000 550 550 300 N.A N.A N.A Max. IL (db) N.A 6 3.43 2.32 2.6 N.A N.A N.A The total values include 1.5 db for connecting hardware. Additional connectors and splices may be used if the power budget of the application allows. Singlemode Max. Length (m) Max. IL (db) Gigabit Ethernet 1000Base-LX 1310n m 10Gbit Ethernet 10GBase-LX4 10Gbit Ethernet 10GBase-L 10Gbit Ethernet 10GBase-E 1550nm 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm 5 000 N.A 10 000 N.A 10 000 N.A N.A 40 000 4.5 N.A 6.2 N.A 6.2 N.A N.A 10.9 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice