The Plastimo range provides a stylish, efficient and mechanically resistant answer MADA18

Similar documents
5 - Ventilation - Exterior Vents

Bilge Pumps. Pump 925C & 1038C compact with integrated handle. Option

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

HATCHES & VENTS. Roof hatches - Camec Roof hatches Vents and cowls...208

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

Instruction Manual. AquaT Marine Toilet. Manual Operated. Toa_manual_ indd :17:35

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST EARLY 1955 CHEVROLET PICKUP

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

abt W Lamp Paraffine Oil n. 0,125 l/h 12 V = (11-14,5 V) 220 x 285 x 115 mm

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

HEATING AND AIR CONDITIONING

CAPILLARY SAMPLING INTRODUCTION. Page 1 CAPILLARY SAMPLING

REPLACEMENT PARTS MANUAL

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

REPLACEMENT PARTS MANUAL

Handshower, Hose & Handshower Accessories

Harvey Chemiclave EC Series Sterilizers

REPLACEMENT PARTS MANUAL

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

Home Stack Washer/Dryers

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Homestyle Stack Washer/Dryers

COMPACT 3020 HE COMBI BOILERS

Enzo Concealed Shower Mixing Valve

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

Flush Jet Technology. Technical Specifications and Installers Manual

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

Hydrotherapy Jets (Remote Water Quality System)

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Home Stacked Washer/Dryer

Home Stack Washer/Dryers

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

2 Premium metal sheds

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

TIMES SQUARE TWO-HANDLE THERMOSTAT

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

WALL MOUNT AUTOPSY STATION CENTER SINK

CYCLONE XHE - MODEL BTH-300A/400A See Page 2

MODEL WALL MOUNT AUTOPSY STATION DOUBLE SINK

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

SAFETY PRODUCTS CATALOG

Energysaver Space Heater Co-Axial Flue System Installation Manual

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

new new Industrial plugs and sockets

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

Style Line Series Vinyl Windows & Doors

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

an ISO 9001:2015 Registered Company

Homestyle Stacked Washer/Dryer

PRODUCT CATALOGUE 2011

NERGYTOWER. energytower Leader in style, quality and safety. ground distribution turrets

Parts Catalogue. /

SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

WARNING SYMBOLS CHECKLIST (CRAFT)

Kiko Concealed Shower Mixing Valve KK80010CP

Power Direct Vent PDV(S&T) Models

FORENSICS GLASS BLOCK MANIFOLD INNOVATION THROUGH CHEMISTRY

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

Pool Protector OPERATING INSTRUCTIONS MANUAL

VA175 SOLDAVAC. Air and Vacuum Pick-Up System

DATA SHEET No SN35 Narrowboat Installation Package

Humidifiers Dealer Parts List Model 400/400M Humidifiers

Heater with Air Conditioning. E-Series Ford Aeromaster

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

1300W Pressure Washer RACHP133A

Husky Diaphragm Pump Suction Kits

A wide range of recreational vehicle exterior utilities sockets featuring unique Whale Easi-Slide Lid.

Installation & User Guide

OPERATIONS MANUAL REV A

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

Suits all KPF849 models

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INVERTER SPLIT - TYPE

Test Unit GTL 100 for Fire Detectors

EDGE PATIO HEATER. User Manual. English

User manual. Kabola HRE serie. Kabola Heating Systems BV Placotiweg 1E 4131 NL Vianen (Utr.) Nederland

Centrif Duo & Centrif Duo Plus

GLASS DECORATIVE COOKER HOOD INSTRUCTION MANUAL READ AND SAVE THE MANUAL BEFORE INSTALLATION AND USE

E C O L O G I C A L C O O L E R S INTELLIGENT PLUS PARTS CATALOGUE

WPLED 26W INSTALLATION INSTRUCTIONS

BUILT-IN CENTRAL CLEANING SYSTEM

a space for all reasons a room for all seasons visit us at for more info

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

TOP AND CABINET PARTS

SUPPLEMENTARY INSTRUCTIONS

HP310-C EXTRACTOR 120V

Owner s Manual. Installation. Instructions. Operating. Maintenance. Troubleshooting

Installation Instructions

SAN JUAN FRESH WATER COOLING SYSTEMS

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

Transcription:

64 Ventilation Ventilator range covering most mounting possibilities typically encountered on a boat. The Plastimo range provides a stylish, efficient and mechanically resistant answer. Ventilator 3 ventilator, can be used on its own to ventilate a locker, or in conjunction with the stiffening adaptor for connection to a hose. Locker ventilation: Drill a 73 mm hole with a hole saw, apply sealant and pushin the ventilation grid. When used in conjunction with a hose to ventilate an inside locker: the ventilation grid is simply clipped on the stiffening adaptor (ref. 47514), requiring no glue nor mechanical fixture. No screws required: neat aesthetics and time-saving assembly. Grid is manufactured from PT, resistant to UV-rays. It is compatible with common sealants and impervious to acetic acids. Resistant to distortion resulting from hygrometry fluctuations. Stiffening adaptor 47514 MD18 Ventilation is ensured by a louvred opening, which also prevents heavy water intrusion. The adaptor can be used on its own to help support a hose along a bulkhead, or can be associated to a ventilator. Manufactured from polypropylene, it is extremely shock and load resistant, and impervious to acetic acids. Suitable for hose 3 () and 70 mm (C). Two lugs (D) hold the hose, while waiting to be secured with stainless steel hose clips (not supplied). Drill a 76 mm hole. Notches () ensure the perfect hold of the adaptor in the bulkhead. C D E Secure the adaptor with 4 x M4 screws and apply sealant for waterproofness (all sealants are suitable). Moulded-in ribs and clips (E) ensure the ventilator s secured position. Some helpful hints When installing a blower, we recommend to place the exhaust louvred ventilator in a reasonably protected area (for example, in the cockpit rather than on the transom), so as to prevent water intrusion into the ventilation circuit. n extra precaution consists in building an elbow in the hose. Use Locker ventilation No mechanical strain exerted on ventilator Locker ventilation in conjunction with a hose Mechanical strain exerted on ventilator Concealed opening (ex. under a cockpit bench) Locker ventilation in conjunction with a hose Mechanical strain exerted on ventilator Visible opening Reference Ventilator 3 daptor alone Ventilator + adaptor White: 47515 MVENO6 Grey: 47516 MVEN07 lack: 47517 MVEN08 47514 MD18

Ventilation 65 Electric blower. Leglatin ccessories 200 mm 160 mm 70 mm 170 mm Flanged adaptor 16276 Mada19 Selected by boatbuilders for its sturdy construction and durability. Suitable for use in the engine compartment, cabins and damp closets or areas. In the engine compartment: it is essential to start the blower 5 minutes before starting the engine. Its compact design allows installation in different positions and in space restricted areas. Can be mounted along or through a bulkhead, horizontally or vertically. n optional mounting bracket adapts the blower to all mounting possibilities. Sturdy polyamide housing for good shock resistance. No polarities. Supplied with 2 black wires, to be connected to either Plus or Minus battery poles. long the bulkhead. Through the bulkhead. Gasket 17642 MSTR50 Exhaust hose: int.: 70mm. Reference Voltage Output Consumption 16274 ml005 12 V 5m 3 /min. 5 mp 16275 Ml004 24 V 4m 3 /min. 2 mp Mounting bracket. Ventilators: see previous pages. ll 70mm Plastimo ventilators are suitable Mounting bracket: 39154 MR25 see diagram

66 Ventilation DORDE OXES Yvan Zedda «Cool n Dry» dorade box Perfect ventilation on board is indispensable to your comfort and contributes to the extended lifetime of your cabin equipment (cushions, cooker, lifejackets...) which are often damaged by humidity and mildew. Plastimo innovation, protected by 2 patents 1 2 Hence an essential question: how can you ensure a permanent ventilation while keeping your boat totally safe and absolutely free from any water intrusion? The «Cool n Dry» dorade box is the answer: its exclusive patented system provides constant ventilation inside the boat, even in very bad weather conditions. Continuous ventilation : when sailing, on a mooring or wintering, the dorade box remains constantly open. No water entry, thanks to the exclusive shut-off system, which closes automatically in the event of a heavy rain or very strong wave. Manual closing by simple finger pressure. Rugged, weatherproof construction: soft PVC vent and S dorade Driling 90 mm 200 mm box, both UV-treated. 16 70 mm 3 4 heavy rain or strong wave (2) shuts off the damper temporarily, preventing any water intrusion in the cabin. s water evacuates (3), the damper lifts up automatically, to allow air circulation again (4).

Ventilation 67 Cool n Dry complete set (vent + dorade) lue Cowl Replacement vent lue Cowl 160 47820 MOX11 17641 MCOW01 If your boat is already equipped with vents, you can increase their ventilation capacity significantly, by simply adding Cool n Dry dorade boxes (ref. 31392 and 31393). Special order only. 295 Dorade box 47824 MOX13 31751 MVEN12 Dorade box in rigid S, flexible vent in soft PVC. Impervious to UV-rays. The Dorade box is supplied complete, with: Flexible cowl vent. Screw-type storm cap. Deck screw-on cover. Cut-out sleeve. Deckhead protection sleeve. Dorade ox lue cowl Length overall Width overall Cut-out ir flow Max. deck thickness 150 16932 MOX09 260 mm 160 mm 77 mm 62 mm 40 mm 205 16933 MOX10 335 mm 200 mm 90 mm 80 mm 60 mm Cut-out protection sleeves Male sleeve Female sleeve Small model 16934 20394 Large model 16928 20306 Germán Seró - Navegar

68 Ventilation E. Y. Leglatin Manufacturing flexible vents stems from Plastimo s 40-year experience in PVC dip-moulding ; this process is also used for the manufacture of rigging screw covers, compass covers and binocular holders. The largest and most prestigious boat builders have made the right choice : they trust Plastimo for the constant quality supply of several flexible vents per year. The most essential features of Plastimo vents are : material softness, resistance to UV-rays, easy mounting, smooth and shiny aspect. C D 230 150 90 Model Vent, complete (includes deck plate + watertight sealing cover) lue cowl Overall width Cut-out ir flow Spare cowl alone (without deck plate) lue cowl 16922 MVEN04 170 mm 75 mm 60 mm 17641 MCOW01 16923 MVEN05 190 mm 90 mm 80 mm 17640 MVEN11 16924 MVEN09 120 mm 75 mm 60 mm 17639 MVESP1 ccessories Deck ring and screw-on cover S. - for vents and C: 16930 Height 22 mm, cut-out 75 mm. - for vents and D: 16929 Height 17 mm, cut-out 90 mm. Cover for vent E: 12809 Soft PVC. C 300 235 D 16926 MVEN03 140 mm 90 mm 80 mm 17649 17628 MVEN10 200 mm 120 mm 120 mm nti-water intrusion sleeve for vents and D: 16927 Height 125 mm, air flow 90 mm. E

Ventilation 69. Leglatin Only 85 mm above deck. S dorade box, shock and UV resistant. Opening and shut-off system operated from the cabin. Equally suitable to allow air in and out. Prevents accidental water intrusion. Streamlined Dorade box 51637 mbox18 Supplied complete with: Dorade body, shut-off system, 85 mm sleeve, white flange. IR IR ccessories Streamlined dorade, cover alone: 51654 IR Ventilation device is open and cabin in ventilated. Ventilation/shut-off unit: 51638 85 mm air flow sleeve: 51639 Flange for above sleeve White: 51640 Wood: 51641 Chrome: 51642 In case of heavy rain or strong wave, the ventilation device is shut off from the cabin. WTER 75 mm 85 mm Once ventilation is shut off, water evacuates along the sides of the dorade box. 120 110 100 90 80 70 30 20 10 Drilling : 90 mm 224 mm 263 mm 5 mm 120 mm 130 mm IR IR IR Equally suitable to allow air in and out.