Commissioning of the ASTA Photoinjector Laser System

Similar documents
Laser Safety Self-Audit Checklist

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Laser Safety Part III Administration

Laser Safety Part III Administration

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

G4 Pulsed Fiber Laser

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

LASER SAFETY PROGRAM

The FEL Facility Optical Diagnostics and FEL Characterization

A. Martinez, A. L. Klebaner, J. C. Theilacker, B. D. DeGraff, and J. Leibfritz. Fermi National Accelerator Laboratory Batavia, IL, 60510, USA

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

G4 Pulsed Fiber Laser

Diode-Pumped Solid-State Blue Lasers

Inspection Detail. General Questions for Laser Labs

Laser & Ultraviolet Light Sources Safety

LASER SAFETY BARRIER

Lessons Learned Events at SLAC. Mike Woods, SLAC National Accelerator Laboratory

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

DUQUESNE UNIVERSITY. Laser Safety Program

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Laser Safety Orientation. Laser Safety Administration

Laser Standard Operating Procedure

Standard Operating Procedure LIGO 700 mw NPRO Laser in Optics Laboratory

Recommended Work Area Controls

Laser Specifications and Characteristics:

The Laser System Supervisor (LSS) is John Hansknecht. Extension: 7096

University of North Florida Laser Safety Manual. Environmental Health and Safety Department

Laser Safety Program ELI-NP

NEED FOR LASER SAFETY

Rice University Laser Safety Manual

PURPOSE OF THE PROCEDURE

Laser Use Registration & Application (L.U.R.)

Laser Safety Training

Information for Proper Posting & Laser Area Sign Templates

3kW 6kW, QUBE Fiber Lasers

North Dakota State University Laser Safety

Particle Accelerators - Their Hazards and the Perception of Safety

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

MME Standard Operating Procedure (SOP)

DOE EFCOG Laser Safety Task Group Benchmark Study of ANSI Z136.1 (2014) Controls Requirements

Laser Registration Requirements: EH&S must be notified after the purchase any class 3B or 4 lasers through the online Laser Registration Form.

Laser Safety Citations

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

PROCEEDINGS OF SPIE. ANSI laser standards, education (Z136.5), research, development or testing (Z136.8)

Laser Safety Program

Important Safety Notice

Fiber Tower Desktop SAFETY & OPERATION MANUAL

Basic Laser Safety Training

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

All personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab.

2018 DOE Laser Worker Survey Results. Matthew Quinn 12 th DOE LSO Workshop 9 May 2018

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Laser Safety Training Guide

Class 1 laser beam sensor safe for your eyes

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

Staying Safely on Target! Laser Safety. Chuck Paulausky, CHMM, LSO

The Laser System Supervisor (LSS) is John Hansknecht. Extension: 7096

Laser Safety Task Group (LSTG) Report

Control Considerations for Safe Laser Alignment

Laser Safety Management

Rutgers Environmental Health and Safety (REHS)

West Virginia University Laser Safety Program

Spectrum Detector, Inc.

Class 1 laser beam sensor safe for your eyes

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

Local Rules for the Use of the Raman Spectroscopy Lab

Lasers and Laser Safety

Gas Temperature Measurements with High Temporal Resolution

Laser Use Authorization

*For inquiries and questions about lasers, see the Yellow-Page.

Why is Laser Safety Important Laser usage is growing rapidly Industrial applications Heavy use now in laboratories for research, analysis Many

McGill University 1/10/2013

Environmental Health and Safety Office North Service Building 3401 North Tillotson Avenue Muncie, Indiana 47306

Laser Class 4 Laser Type Nd-YAG Laser Manufacturer New Wave Research Laser Model SoloII-30 PIV Laser Serial / Id # Serial number 16582

UC IRVINE LASER SAFETY PROGRAM

Review of Recent Laser Incidents at DOE facilities. Joanna Casson Los Alamos National Laboratory

Laser Safety Manual. for. Bowling Green State University

Laser Safety. The George Washington University Office of Laboratory Safety Ross Hall, Suite B

Directive on Laser Safety. NRC Occupational Safety and Health Manual

Laser Safety Policy Statement...2 Laser Safety Program...2 Related Laser Safety Program Documents... 2 Additional Resources... 2

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

Hands-On Laser Beam Path Alignment Practical. Environment, Safety, Health & Quality Office SERF E141 Last updated: 12/28/2017

American National Standard

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

THE UNIVERSITY OF TEXAS RIO GRANDE VALLEY LASER SAFETY MANUAL. August 2016

Non Ionizing Radiation Audit checklist

Laser Safety Products. Edition 20

Class 1 laser beam sensor safe for your eyes

UNIVERSITY OF KANSAS LAWRENCE CAMPUS

Available online at ScienceDirect. Physics Procedia 67 (2015 )

The University of Mississippi BASIC LASER SAFETY

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

ENVIRONMENTAL HEALTH AND SAFETY STANDARD OPERATING PROCEDURES

Safety Manual Section 15 Radiation Safety

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Fibre Optic Basics FIA Summer Seminar 2014

Laser Safety Program Manual

Transcription:

Commissioning of the ASTA Photoinjector Laser System Jamie Santucci Advanced Accelerator R & D Fermi National Accelerator Laboratory DOE LSO Workshop, September 11, 2013

Outline Fermilab ASTA Photoinjector Laser Laser System Control System Safety System

Fermilab Overview DOE Particle Physics Energy, Intensity, Cosmic Tevatron Neutrino Experiments Muon Campus IARC LHC R&D Dark Energy & Dark Matter AAR&D ASTA

ASTA Overview e- LINAC (ILC type) MeV GeV beams (5-50MeV / 300-1500MeV) High rep-rate (1-3MHz 1.3GHz, 1-5Hz CW) High brightness (peak & average) Extremely stable beam (spatially & temporally) Storage ring (IOTA) (50-100MeV/e-, 2.5MeV/p) Photoinjector: 3ps/3MHz/1ms/5Hz, 5-50MeV e- SRF (Superconducting RF accel. cavities) Experiment Areas (Low E & High E)

ASTA Campus

Injector Overview

Drive Laser System illab Injector Laser Lab Laser System Fiber Seed DPSS Amps 4HG

Drive Laser System -illab 500ft 2 Class 10,000 Cleanroom Climate Controlled to 1 degf rms 16ft Main Table, 12ft Secondarys

Drive Laser System Main Table

Drive Laser System -Overview

Drive Laser System -Seed YbFA Seed Calmar Lasers inc. 1053nm Fiber Laser 1.3 GHz Mode-locked <0.2 ps jitter 81 MHz Pulse Picked Fiber Amplified 500 mw to Free-space

Drive Laser System -Amps Nd:YLF DPSS Amps DPMP Cavity 1 uj DP2P Stations 9 uj NG-CEO 180 uj

Drive Laser System -4HG 4HG BBO: IR Green 527nm 80 uj BBO: Green UV 263nm 25uJ

Drive Laser System -Pulsetrain 5% rms Amplitude Jitter 300us Train Attained Working Towards 1ms

ACNET Analog Control System Settings Readbacks Digital Control Status Parameters Scaling Datalogging Sequencing S&R

Synoptic Laser Interface Controls GUI

Synoptic Laser Interface (cont.) GUI Subpages

Interlocks Class III & IV Enclosures Administrative Controls PPE Laser Safety System

Laser Safety System (cont.) Interlocks FNAL Accelerator ESS Hardware Loops A&B Software Loops A&B Safety Rated PLC Siemens Module 315F Laser Lab, Transport, Cave

Laser Safety System (cont.) Logic Diagram Overviews & Status

Laser Safety System (cont.) Controlled Access Storeroom Lock Unique Keys Laser PS Contactor Fire Key

Laser Safety System (cont.) Class IV enclosures (NHZ) Laser lab Locked Metal Box Sealed Penetrations Transport GV & Vacuum Switch Cave 9WX Optics Box Locks e- Beam Vacuum System

Laser Safety System (cont.) IR DPSS Containment

Laser Safety System (cont.) 4HG and UV Containment

Laser Transport Polycarbonate Stainless Steel Vacuum ABS & Aluminum

Laser Safety System (cont.) Administrative Controls ES&H Training IIIb & IV Accounting SOP With Sign-offs OJT With Sign-offs Locks and Safety Screws Signage

VISIBLE AND/OR VISIBLE INVISIBLE AND/OR LASER INVISIBLE RADIATION LASER AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION RADIATION AVOID EYE OR SKIN CLASS 4 LASER PRODUCT FNAL/AD/NML LASER ROOM IN ANY EMERGENCY DIAL 3131 PROPER EYE PROTECTION REQUIRED EXPOSURE LASER TRAINING TO DIRECT AND EYE OR EXAM SCATTERED REQUIRED RADIATION PROPER EYE PROTECTION REQUIRED POWER/ LASER MEDIUM REQ. OD λ ENERGY Calmar/NG Yb fiber/ylf 6 1030-1060nm 300μJ Dilas Diodes Diode 6 808 nm 200W 2HG BBO 3.8 527 nm 40μJ 4HG BBO 7.2 263 nm 10μJ

Laser Safety System (cont.) PPE Laser Eyewear Clothing Requirements Face Shields Gloves Misc. Electrical Kentek C505C Newport UV gloves

THANK YOU NML Contacts and References: Fermilab, http://www.fnal.gov/ ASTA, http://asta.fnal.gov/ Laser Jamie Santucci, santucci@fnal.gov Jinhao Ruan, jhruan@fnal.gov Safety System Randy Zifko, rmzifko@fnal.gov Controls Chip Edstrom, edstrom@fnal.gov Synoptic, http://synoptic.fnal.gov/

Backup Slides Synoptic Architecture Fermilab 3 Frontiers ASTA Parameters ASTA Overview Laser / e- Beam Parameters

The Synoptic Architecture

Fermilab Three Frontiers Energy Intensity Cosmic Accelerator Stewardship

ASTA Parameters (a) Optical pulse stacking methods or field-emission sources could lead to smaller bunch separation. (b) normalized rms values for an uncompressed beam (c) nominal value corresponds to a 3.2-nC compressed bunch without operation of CAV39

ASTA Overview (cont.)

Laser / e- beam parameters Transverse spot size available: 0.2-6mm Bunch = 3ps (rms) 1/fb = 3MHz 1/fmac = 5Hz Charge = 0.05-3.2 pc

Laser Safety System (cont.)