Promo With heating regulation up to 250 C for welas aerosol sensors

Similar documents
Product data sheet Palas Promo 2000

AEROSOL SPECTROMETERS

Product data sheet Palas Fidas 200 S

FIDAS FINE DUST MONITORING SYSTEMS

The New DUSTTRAK II and DRX Aerosol Monitors

The New DUSTTRAK II and DRX Aerosol Monitors

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

CONFIRMATION of Product Conformity (QAL1)

ISO INTERNATIONAL STANDARD

Simultaneous Real-Time Dust Mass Measurement with the

Infrared Moisture Balance (FD-660)

Praetorian Fibre Optic Sensing

PSA Series. Particle Size Analyzer

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Mercury Vapor Monitor VM-3000

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

1,000W (DAP-60K: 100 W per digestion vessel)

VM-3000 Mercury Vapor Monitor

THE NEW GENERATION VACUUM PUMP SYSTEM SC

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Praetorian Fibre Optic Sensing

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Constant climate chambers

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Process Alarm Solutions

WG Buried Cable Perimeter Detection System

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Environmental simulation chamber for complex alternating climate profiles

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

Constant climate chamber with humidity

Compact Ultra Low Temperature Chamber

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

AV6419 BOTDR. Product Overview. Main Features

Dew point set DS 400

XSD Dry Cabinet

Fibre Optic Basics FIA Summer Seminar 2014

VM-3000 Mercury Vapor Monitor

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

CEIA THS/PH21. series. High Performance Pharmaceutical Metal Detection Systems. Superior and Consistent Detection

Praetorian Fibre Optic Sensing

Drying and heating chambers

Vacuum drying oven for non-flammable solvents

Continuous, real-time detection, alarming and analysis of partial discharge events

XSD Dry Cabinet

CEIA THS/PH21. series HIGH PERFORMANCE PHARMACEUTICAL METAL DETECTION SYSTEMS. Superior and Consistent Detection Enhanced Product Throughput Rate

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Reproducible Climate...

Constant climate chamber with ICH-compliant illumination

Certificate: _01 / 22 March 2013

VARIO The sleek, switching light curtain for reliable object detection and area monitoring


Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION STEAM TRAP INSPECTION VALVE INSPECTION TIGHTNESS TESTING DETECTION OF PARTIAL DISCHARGES

Constant climate chambers

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

MINI2 MOST ACCURATE COMPACT OTDR

THS 21 SERIES. Quality Control at its finest MULTI-SPECTRUM INDUSTRIAL METAL DETECTORS FEATURES

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

Panel Mounted Fault Annunciator Series

Constant climate chambers

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Automatic Isokinetic Sampler ST5

ß-Aerosolmonitor FHT 59 C

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

(Inside illumination as option available.) Biogas Batch Fermentation System. With Automatic Data Logging in Real Time

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Constant climate chambers

Filters & Centrifugal Separators

Remote alarm indicator and test combination MK2430

SHAKING WATER BATHS ENGLISH

Contamination Control for Electronic and Semiconductor Applications

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

Lighting of the future

CERTIFICATE of Product Conformity (QAL1)

Air & Water Heat Pump R832

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Technical Specification PILATUS 100K Detector System

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

gas monitoring system

Universal fault annunciator for panel mounting

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

Audit Report. Global GAW station Pallas, Finland

Nardalert S3 TM Non-Ionizing Radiation Monitor

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Specifications Wavelength Range: 190 nm to 800 nm continuous

Transcription:

Scattered-light aerosol spectrometer system for process measurement technology and monitoring applicationswith light wave conductor technology Model Variations H With heating regulation up to 250 C for welas aerosol sensors HP With automatic regulation of the sampling flow through the welas aerosol sensorsatanoverpressureof2to10barorintemperaturesupto120 C P With automatic regulation of the sampling flow through the welas aerosol sensorsatanoverpressureupto10bar Page1of7

Description is a light-scattering aerosol spectrometer system for particle size analysis and concentration determination that canbeequippedwithallwelas sensors. On, the welas sensors equipped with different measurement volumes, as required, can be easily connected via fiber optic cables and interchanged as required. These sensors allow reliable measurement in the concentration range from <1particle/cm 3 upto10 6 particles/cm 3 andareavailableformeasurementingases,aswellasinliquids.pleaseobservethe "welas sensors" product data sheet. Uniqueareuptofourmeasuringrangesinonlyonedevice: 0.2µm 10µm 0.3µm 17µm 0.6µm 40µm 2µm 100µm(additionallyforsensors2300and2500). Promo 2000isfamousforupto128sizechannelspermeasuringrangeandaconcentrationrangefrom<1particle/cm 3 to 10 6 particles/cm 3. A touch display ensures user-friendly operation. Measurements can be started easily, and all data, such as the current number distribution and the number concentration, as well as 24 further statistical values, can be evaluated and displayed in real time. With Promo as a standalone measuring device(i.e. without external computer) measurements are performed continuously. Allincomingdatacanbestoredwithamaximumtemporalresolutionof1s.Promo 2000canthereforemeasureandsave data over weeks independently. For data transfer, Promo can also be integrated into a company network. Promo 2000hasastandardinterfaceandcanbecontrolledbyaprocesscontrolsystemorbyasimpleLabviewprogram. For this reason, is especially well suited for control and monitoring applications. Temperature, humidity and pressure sensors can be connected. Palas offers remote maintenance for the device and data access via www.palas.de/user. The new measurement technology: Promo 2000offersanew,fast20MHzsignalprocessingprocessor,whichanalysestheprogressionofeachparticlesignal. This makes it possible to recognise coincidental events in light scattering measurement technology at the individual signal and correct them(according to Dr. Umhauer/ Prof. Dr. Sachweh). This way it is possible to increase the maximum concentration limitupto10 6 particles/cm 3 (welas 2070sensor).Alsoinlowconcentrations<1particle/cm 3 withthewelas 2500sensor, this leads to a higher measuring accuracy. High classification accuracy and high particle size resolution are guaranteed by the following special features(see Graph 1): White light and 90 light-scattering detection Unambiguous calibration curve Patented T-aperture Noborderzoneerror New digital individual signal processing Coincidence detection and correction of the individual signal making it possible to measure higher concentrations Page2of7

Graph 1: Example with 2200 sensor is characterized by its very high counting efficiency starting from 0.2 µm! Graph2:Examplewith2200sensor,inrelationtoLAS-XII The new : Page3of7

The is characterized by its optical fibre technology. The welas aerosol sensor is connected via a fiber optic cable withalengthupto30mwiththepromocontrolunit.thisleadstoaminimizationofparticlelossesinlongsamplinglinesby simply installing the sensor directly at the sampling location. Page4of7

Benefits Measuringrangeof0.2to100µm(4measuringrangesselectableinonedevice) Uptofourmeasuringrangesinonlyonedevice: 0,2µm 10µm 0,3µm 17µm 0,6µm 40µm 2µm 100µm(additionallyforsensors2300and2500) Upto128sizechannelspermeasuringrange Concentrationrangeof1particle/cm 3 to10 6 particles/cm 3 Calibration curves for different refractive indices Very high and reproducible counting efficiency rate starting at 0.2 µm Pressure-resistant up to 10 bar(optional) Heatable to 250 C(optional) Optical fibre technology Simple operation with a large touch display Calibration, cleaning and lamp replacement can all be performed independently by the customer ExternalcontrolbyRS232orEthernet With analysis software PDAnalyze Optional: Software PDControl for operation as welas digital available Low maintenance Reliable function Reduces your operating expenses Page5of7

Datasheet Parameter Description Interfaces USB, Ethernet, RS232/485, Wi-Fi Measurementrange(size) 0,2µm 10µm 0,3µm 17µm 0,6µm 40µm 2µm 100µm Size channels Up to 128(64/decade) Measuring principle Optical light-scattering Measurementrange(numberC N ) lt;1 10 6 particles/cm 3 Timeresolution Upto1s Thermodynamicconditions 10 40 C,-100 50mbar Volumeflow 5l/min Data acquisition 20 MHz processor, 256 raw data channels, digital Lightsource Xenonarclamp35W Power consumption 100 W User interface Touchscreen, 800 480 Pixel, 7" Powersupply 115 230V,50 60Hz Housing Table housing, optionally with mounting brackets for rack-mounting Dimensions 185 450 315mm(H W D)(19") Support options direct remote access, Palas webserver service Weight Approx. 8 kg(control unit), approx. 2.8 kg(sensor) Operating system Windows embedded Data logger storage 4 GB Compact Flash Software PDControl, FTControl, PDAnalyze Installation conditions +5 +40 C(control unit) Page6of7

Applications Emission monitoring of installations Control of grinding and classification processes Monitoring of production processes in the food, pharmaceuticals and chemicals industries Testing of complete filters, inertial and wet separators or electrostatic precipitators Palas GmbH Partikel- und Lasermesstechnik Greschbachstrasse 1 76229 Karlsruhe Germany Managing Partner: Dipl.-Ing.(FH) Leander Mölter Dr.-Ing. Maximilian Weiß Commercial Register: Mannheim HRB 103813 Place of Business: Karlsruhe USt-Id: DE 143585902 St-Nr: 3 4416/07832 Bank Data: BW-Bank Karlsruhe BIC: SOLADEST IBAN:DE77600501017495502659 Deutsche Bank Karlsruhe BIC: DEUTDESM660 IBAN:DE95660700040095946000 Contact: E-Mail: mail@palas.de Internet: www.palas.de Tel: +49(0)721 96213-0 Fax: +49(0)721 96213-33 Page7of7