* TEST REPORT. Çağlayan Basım Yayın Dağıtım Amb. san. Tic. A.Ş. Page 1 of 5 APPLICANT NAME

Similar documents
Cem Kırt.Büro Malz.ve Gıda Tic. Ltd. Şti.

TEST REPORT Page 1 of 28. Uçar Oyuncak San.ve Tic.Ltd.Şti.

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

Sýnishorn ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014

ENGINEERING EVALUATION

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Procedure for the Approval of New Fire Detection and Alarm Technologies

ISO Textiles Domestic washing and drying procedures for textile testing

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps

SOUTH AFRICAN NATIONAL STANDARD

This document is a preview generated by EVS

BOARD OF COUNTY COMMISSIONERS

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

ISO 6396 INTERNATIONAL STANDARD. Earth-moving machinery Determination of emission sound pressure level at operator's position Dynamic test conditions

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

GS-12 GREEN SEAL STANDARD FOR OCCUPANCY SENSORS FIRST EDITION FEBRUARY 14, 1997

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 2: Performance criteria

PQS performance specification

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements

ISO INTERNATIONAL STANDARD

ISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

SOUTH AFRICAN NATIONAL STANDARD

American National Standard

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

ISO/TS TECHNICAL SPECIFICATION

INTERNATIONAL STANDARD

Energy Efficiency Schemes Brief Introduction

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

BUSINESS PLAN CEN/TC 79 RESPIRATORY PROTECTIVE DEVICES EXECUTIVE SUMMARY

ISO 2896 INTERNATIONAL STANDARD. Rigid cellular plastics Determination of water absorption

Grower Summary PO 005

INTERNATIONAL STANDARD

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion

American National Standard. for Roadway and Area Lighting Equipment Solar Lighting Systems ANSI C Secretariat:

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

INTERNATIONAL STANDARD

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

Verification & Testing for Conformity Assessment / EC Verification. NB-Rail (ERTMS Group)

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

ISO INTERNATIONAL STANDARD

Type 5 Certifications:

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

INTERNATIONAL STANDARD

IECRE OPERATIONAL DOCUMENT

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

The European Vending Association TEMPERATURE MEASUREMENT PROTOCOL

ISO INTERNATIONAL STANDARD. Footwear Test methods for whole shoe Washability in a domestic washing machine

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 2: Performance criteria

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

ISO INTERNATIONAL STANDARD. Road vehicles Alarm systems for buses and commercial vehicles of maximum authorized total mass greater than 3,5 t

SOUTH AFRICAN NATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Safety identification Escape and evacuation plan signs. Identification de sécurité Plans d'évacuation et de secours

ISO 3858 INTERNATIONAL STANDARD. Rubber compounding ingredients Carbon black Determination of light transmittance of toluene extract

SIGMADEK, LTD. FIRE TEST REPORT

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS (EEHA) TESTING STANDARD

This is a preview - click here to buy the full publication COMMISSION ELECTROTECHNIQUE INTERNATIONALE INTERNATIONAL ELECTROTECHNICAL COMMISSION

ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 1: Electrical cone and piezocone penetration test

ISO 7779 INTERNATIONAL STANDARD. Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

ISO INTERNATIONAL STANDARD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ANSI C Revision of ANSI C National Electrical Manufacturers Association. American National Standards Institute, Inc.

FUNDERMAX GMBH FIRE TEST REPORT

Test Report Garvan Enterprises Limited

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation

Advokatfirmaet BAHR AS - ENGAGEMENT TERMS

PQS performance specification

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Petroleum and natural gas industries Subsurface safety valve systems Design, installation, operation and redress

AMCA Publication

TEST REPORT No

BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS EXECUTIVE SUMMARY

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Test Report. Appliance EMF Testing

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

GUIDELINE FOR THE APPLICATION OF SRPS CEN/TS WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES

ISO INTERNATIONAL STANDARD

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

ISO INTERNATIONAL STANDARD

esense CO2 Transmitter and Alarm

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

PQS Independent type-testing protocol

Transcription:

Form LG.044/Rev.1 TEST REPORT Page 1 of 5 REPORT NUMBER : APPLICANT NAME ADDRESS SAMPLE DESCRIPTION : BUYER : TURT180148844 Çağlayan Basım Yayın Dağıtım Amb. san. Tic. A.Ş Sarnıç Yolu No:7 Gaziemir / İzmir Tel: 0232 274 22 15 Fax: 0232 274 22 84 Attention : İNFO,Yalçın Eryılmaz (infocaglayan@caglayanmatbaasi.com;yalcin.eryilmaz@alfadefter.com) SPIRAL CARTOON COVER BOOK & PAINT BOOK TÜKID DATE IN : 03 August, 2018 (10:42) RESUBMIT DATE : 09 August, 2018 DATE OUT : 17 August, 2018 Uğur Yılmaz Customer Care Executive Zeynep Akın Chemical Laboratory Manager *180148844 180148844* 180148844

R E S U L T S Page 2 of 5 PHOTO OF PRODUCT TESTED :

R E S U L T S Page 3 of 5 Part No Tested Sample 1 Multicolor square (blue/green) designed cover 2 Multicolor square (yellow/orange) designed cover 3 Multicolor feather designed cover 4 Multicolor bird designed cover 5 Multicolor (pink/green) designed cover 6 Multicolor (purple/white/blue) designed cover 7 Multicolor (grey/green) designed small cover 8 Multicolor (green/pink/beige) designed small cover 9 Multicolor square (orange/blue) small cover 10 Pink/blue printed white paper 11 Grey printed small white paper 12 White coated of metal spiral string 13 Silver metal spiral string RESULTS : Analysis Parameter Determination of Cadmium Content Determination of Total Lead (Pb) Content Reference Analysis Method BS EN 1122:2001 (Method B) With reference to USEPA 3050B / USEPA 3051 /USEPA 3051A/ US EPA 3052,by acid digestion and determinated by ICP-OES PASS FAIL Norm Limit P - 1000 ppm (0.1%) for painted products 100 ppm (0.01%) for plastic materials Standard for Norm Limit Tested Sample 91/338/EEC Part 1-12 P - <500 ppm (0.05%) REACH Part 1-13 P = MEETS BUYER' S REQUIREMENT / F = DOES NOT MEET BUYER' S REQUIREMENT / NR = NO REQUIREMENT / SC=STILL CONTINUES / X=NOT PERFORMED / LS = LACK OF SAMPLE This report (including any enclosures and attachments) are prepared for the exclusive use of the Customer(s) named in the report and solely for the purpose for which it is provided and on the basis of instructions and information and/or materials supplied by Intertek s Customer. The test results relate only to the specific items tested and are not intended to be a recommendation for any particular course of action. Customer is responsible for acting as it sees fit on the basis of such results. Unless Intertek provide express prior written consent, no part of this report should be reproduced, distributed or communicated to any third party. Intertek do not accept any liability if this report is used for an alternative purpose from which it is intended, nor do Intertek owe any duty of care to any third party in respect of this report. Except where explicitly agreed in writing, all work and services performed is governed by Intertek Standard Terms and Conditions of Service which is available on request or can be obtained at http://www.intertek.com/terms. The reported uncertainity is based on a standard uncertainity multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%. The uncertainity evaluation has been carried out in accordance with ISO/IEC 17025 and TÜRKAK accreditation requirements. Unless otherwise is specified, all Pass or Fail results are given without uncertainity considered. When uncertainity is taken into account, the result may be borderline. Borderline results need to be re-tested to determine their disposition up to customer s decision. Opinions and interpretations expressed herein are outside the scope of TÜRKAK accreditation. Tests marked (*) in this test report are not included in the TÜRKAK accreditation schedule for this laboratory.

R E S U L T S Page 4 of 5 Determination of Cadmium Content BS EN 1122:2001 (Method B) and IHTM AL.2.004 : 2001 using microwave or acid digestion Part 1 <5 ppm 100 ppm (0.01%) Part 2 <5 ppm 100 ppm (0.01%) Part 3 <5 ppm 100 ppm (0.01%) Part 4 <5 ppm 100 ppm (0.01%) Part 5 <5 ppm 100 ppm (0.01%) Part 6 <5 ppm 100 ppm (0.01%) Part 7 <5 ppm 100 ppm (0.01%) Part 8 <5 ppm 100 ppm (0.01%) Part 9 <5 ppm 100 ppm (0.01%) Part 10 <5 ppm 100 ppm (0.01%) Part 11 <5 ppm 100 ppm (0.01%) Part 12 <5 ppm 100 ppm (0.01%) ppm (part per million) =mg / kg Detection Limit =5 ppm < =Less Than % =Percentage based on dry weight of sample REMARK : As per Cadmium Content Requirement in Annex XVII item 23 of the REACH Regulation (EC) No: 1907/2006 (Formerly Known as Directive 91/338/EEC), Acid Digestion Method was used Total Cadmium Content was determined by ICP-OES Estimated Total Uncertainty = ±4%

R E S U L T S Page 5 of 5 Determination of Totel Lead (Pb) Content With reference to USEPA 3050B / USEPA 3051 /USEPA 3051A/ US EPA 3052,by acid digestion and determinated by ICP-OES Part 1 Not Detected <500 ppm (0.05%) Part 2 Not Detected <500 ppm (0.05%) Part 3 Not Detected <500 ppm (0.05%) Part 4 Not Detected <500 ppm (0.05%) Part 5 Not Detected <500 ppm (0.05%) Part 6 Not Detected <500 ppm (0.05%) Part 7 Not Detected <500 ppm (0.05%) Part 8 Not Detected <500 ppm (0.05%) Part 9 Not Detected <500 ppm (0.05%) Part 10 Not Detected <500 ppm (0.05%) Part 11 Not Detected <500 ppm (0.05%) Part 12 Not Detected <500 ppm (0.05%) Part 13 Not Detected <500 ppm (0.05%) ppm (part per million) =mg / kg < =Less Than Detection Limit =5 ppm Estimated Total Uncertainty = ±8% ## END OF TEST REPORT ##