PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

Similar documents
PRODUCT SPECIFICATION FireMaster Plus

PRODUCT SPECIFICATION FireMaster Plus Concertina

PRODUCT SPECIFICATION FireMaster Concertina

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

FIREMASTER CONCERTINA TM

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

FIRE & SMOKE CURTAINS

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

FIRE & SMOKE CURTAINS

Smoke and Fire Curtains

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

1 P age w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

Architectural Specification Sheet

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

A. Section Masonry Assemblies: Anchor placement in masonry.

Abrasion Resistance of Fluoropolymer and polyester Coatings

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

Technical Manual (European Standards)

Operation & Maintenance Manual

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

Firetex steel fire shutters

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Classification of Fire Performance of Wall and Ceiling Lining Materials

UNIFIED FACILITIES GUIDE SPECIFICATIONS

WALLCOVERINGS WALLCOVERINGS

A REVOLUTIONARY APPROACH TO FIRE SAFETY

SECTION AUTOMATIC TRANSFER SWITCHES

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION AIR DOORS

SECTION AUTOMATIC TRANSFER SWITCHES

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

FIRE & LIFE SAFTEY STANDARD

LaserFOCUS VLF-250 Engineering Specification

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION SECURITY TESTING AND COMMISSIONING

Condensing Units CUS 15-60

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

Electrical Safety Policy and Management System

CI/Sfb ( ) smoke stop. Smoke Barriers for all applications... Swiss Re London. Lane Crawford Singapore. London.

SECTION PACKAGED HEAT TRANSFER SYSTEM

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

ACTIVE FIRE CURTAINS INTISI7

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION FIRE DETECTION AND ALARM

WITH OMRON E5CC CONTROL

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

SMOKE AND FIRE CURTAINS

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

R OL L ING F IR E DOOR T E S T ING P R OGR AM

Intumescent Fire Dampers

The EN54 Part 2 and 4 Fire System

Remote Control Garage Doors

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Fire alarm system specification for multiple tenant retail buildings

BLE Smoke and Fire Curtains

Fire detection and alarm

UNIFIED FACILITIES GUIDE SPECIFICATIONS

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

1.3 REFERENCE STANDARDS

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

SECTION AUTOMATIC TRANSFER SWITCHES

UFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

B SERIES ELECTRIC FURNACE

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Transcription:

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex 1 GENERAL 1.1 Scope Coopers FireMaster NVS Horizontal Simplex active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated, delivered, installed and commissioned with all required components as outlined in this specification. 1.2 Design Criteria The designer must consider the following: Ø Structural movement of the building Ø Building tolerance Ø Fire resistance requirements Ø Activation requirements for the fire barriers Ø Optional items that are required with the product Ø Maintaining the area underneath the curtain as clear from obstructions 1.3 Related Works Co-ordination is required with the following trades: Ø Structure Steel or formwork Headbox must be installed level to 2mm tolerance across the entire width of the headbox Ø Ceilings & Partitions Ø Floor Ø Handrails/balustrades Ø Electrical 240V 20A power supply to each curtain controller Ø Dry Fire Normally closed volt free alarm signal to each curtain controller 1.4 Submittals Shop drawings detailing the location, size, requirements by others and design of the Coopers FireMaster NVS Horizontal Simplex Fire Curtains shall be submitted to the Principal Contractor and the drawings approved prior to the commencement of the manufacture process. If required in the architectural specification, samples of the fabric and components will be delivered to the Principal Contractor on request. 1.5 Quality Assurance Materials and work shall conform to the latest edition of reference specifications and the manufacturer shall implement and operate an approved Quality Assurance system for the product, complying with the requirements of ISO 9001: 2008. 1.6 Relevant Standards Coopers FireMaster NVS Horizontal Simplex automatic fire barriers have been tested by an approved industrial research and testing organisations registered by the National Association of Testing Laboratories (NATA) to the following Standards: Ø AS/NZS 1530.3: 1999 : Methods for fire tests on building materials, components and structures - Simultaneous determination of ignitability, flame propagation, heat release and smoke release Ø AS 1530.4: 2005 : Methods for fire tests on building materials, components and structures - Fire-resistance test of elements of construction Ø ISO 9001: 2008: Quality management systems Product Specification - FireMaster NVS Horizontal Simplex Page 1 of 5

1.7 Warranty Coopers Fire Pty Limited warrants that its FireMaster NVS Horizontal Simplex Fire Curtains are free from manufacturing defects for a period of not less than five (5) years when installed, maintained and used in accordance with Coopers specifications and operational manuals. 2 Product 2.1 Approved Manufacturer Coopers Fire Pty Limited Unit 4 36-44 Atkinson Road, Caringbah NSW 2229, Australia Tel: +61 2 9526 3100, Fax: +61 2 9526 3111 Email: info@coopersfire.com.au, Web: www.coopersfire.com.au Coopers Fire Limited Edward House, Penner Road, Havant, HANTS PO9 1QZ, England Tel: +44 23 9245 4405, Fax: +44 23 9249 2732 Email: info@coopersfire.com, Web: www.coopersfire.com 2.2 Location Coopers FireMaster NVS Horizontal Simplex fire curtains are to be installed in the locations shown on the Architectural drawings. 2.3 Proprietary Item Coopers FireMaster NVS Horizontal Simplex Fire Curtains including Ø Galvanised mild steel boxing, tubular Gravity Fail Safe DC geared motor with brake, fire resistant fabric, galvanised mild steel bottom bar, galvanised mild steel side guide boxing, guidance wheels, pulleys including metal strapping, motor controller, power and fire zone controller incorporating battery backup and emergency power supply Ø The boxing fixes back to the building structure and frames the horizontal opening that is to be fire protected. All components required to support, or allow the operation of the horizontal fire curtain will be within the mild steel boxing and there will be NO SUPPORTS between the boxes. Specifically there will be no support wires that cross the void to support or operate the fabric when the curtain is deployed. Ø Complete product testing and certification to AS 1530.4(2005) to an FRL of -/120/- clearly showing the maximum allowable size for the curtain and this maximum size shall not be less than the installed sizes required. Ø Maximum size of the product is 6 meters width x 10 meters draw Ø Complete product testing and certification to AS/NZ 1530.3(1999) with an index rating not greater than: Ignitability 0 Spread of Flame 0 Heat Evolved 0 Smoke Developed 3 2.4 System Components 2.4.1 Fabric Roller Boxing The fire curtain is concealed in a galvanised mild steel headbox of size 400mm x 225mm x 1.2mm thick which provides protection for the barrier (curtain) and acts as a fixing element to the building structure. This can be powder coated to a standard RAL colour. 2.4.2 Receiver Boxing The receiver boxing houses the parts of the pulley and strapping system and provides a location for the bottom bar to close to when activated. It is a 250mm x 225mm x 1.2mm thick galvanised mild steel boxing which provides protection for the barrier (curtain) and acts as a fixing element to the building structure. This can be powder coated to a standard RAL colour. 2.4.3 Motor The motor consists of a 24V DC motor inclusive of the required internal gears and torque to lift the curtain and descend at the required speed. It will also have a separate 24V DC brake which will hold open the curtain drawing minimal power. The motor must allow for the curtain to descend at the required speed when all consumable power sources are removed (Gravity Fail Safe). Internal travel or limit switches are not to be incorporated within the motor system that requires ongoing service and maintenance. The motor is required to be instructed when to stop from the controls. Product Specification - FireMaster NVS Horizontal Simplex Page 2 of 5

2.4.4 Fabric Coopers EFP 4/1000 The curtain material is a satin weave fibreglass fabric with a silver polyurethane coating on both sides and integral stainless wire. It is 0.54mm thick, and weighs approximately 690g/m² in its finished form. The fabric is manufactured in widths of approximately 1.9m and is tested in the vertical orientation including the sewing yarns. 2.4.5 Barrel Assembly As a single barrel construction where maximum dimensions are assessed by a NATA accredited laboratory as 6m width x 10m draw. All barrels are fabricated of structural quality ERW galvanized steel seamless roller tube of minimum 70mm diameter with a wall thickness of not less than 1.5mm. 2.4.6 Bottom Bar The bottom bar assembly is attached to the lower edge of the fabric, and acts to keep the fabric taut, allowing correct operation of the curtain and minimising deflection. The bottom bar must form one continuous bar when installed. The bottom bar is galvanised mild steel and can be powder coated to a standard RAL colour. 2.4.7 Side Guide Boxing The fabric is withheld in a galvanised mild steel guide section which are within side guide boxing housing of size 150mm x 225mm x 1.2mm thickness. The side guide needs to be tested as part of the complete system and provide the required fire separation and acts as a fixing element to the building structure. The side guide boxing can be powder coated to a standard RAL colour. 2.4.8 Controls The barrier assemblies shall move to their fire operational position in a controlled manner, and shall be reliant upon a primary and auxiliary Battery Back Up (ERU) system in the event of a total mains failure. The auxiliary Battery Back Up (BBU-ERU) system shall be connected to an independent and maintain power circuit (provided by others) from the primary unit. The barrier assemblies must commence movement upon initiation and move to the fire operational position with velocities within the range of 0,06 m/s to 0,3 m/s using the unique VarioSpeed function. Speeds may be dictated by those authorities having jurisdiction for safety in use according to the location, nature or function of each unit. The barrier assemblies must show the ability to operate with the barrier retained in side channels to resist pressure (as standard 20 Pa and ad-hoc impact using a 50Kg weight dropped from a height of 1 m at the end of the fireresistance test. The barrier assembly shall have fail-safe with controlled braking system and drive mechanisms. All working parts shall be totally enclosed and protected within the steel roller and shall be tested as part of the complete assembly for fire resistance. Any combination of the alarm/control signal provided by the Electrical Subcontractor, and/or the specified fail-safe functions shall activate the system. See datasheet (VS6-ERU-CG-HORIZ) 2.5 Product Performance: The complete FireMaster NVS Horizontal Simplex product inclusive of fabric roller box, receiver box, side guide boxing, motor, fabric, and bottom bar is to be tested or assessed to AS1530.4 (2005) achieving an FRL of -/120/- clearly showing the maximum allowable size for the curtain and this maximum size shall not be less than the installed sizes required. The maximum size being 6 meters wide x 10 meters draw. The fabric must be tested to AS/NZ 1530.3(1999) with an index rating not greater than: Ignitability 0 Spread of Flame 0 Heat Evolved 0 Smoke Developed 3 The complete system is to be designed to operate for a minimum 1,000 cycles at normal ambient temperatures in the range from 0ºC to 60ºC, and to withstand fire at temperatures up to 1000 ºC for over 120 minutes once only. 2.6 Operation The fire curtain will remain retracted within its headbox until it is automatically activated by the fire alarm signal. Upon activation the fire curtain will move to its fire operation position, completely closing the opening and creating a fire compartment. Product Specification - FireMaster NVS Horizontal Simplex Page 3 of 5

Once the fire alarm signal is restored the FireMaster NVS Horizontal Simplex Fire Curtain is manually reset by pressing the reset button on its controller. This can be amended to automatic reset if requested.. 2.7 Labelling The Coopers FireMaster NVS Horizontal Simplex Fire Curtain must be labelled with a metal tag riveted to the bottom bar clearing showing the curtain details, manufacturer, installation date and FRL. 2.8 Optional Components 2.8.1 Visual Alert A red local flashing light will flash whilst the curtain is down or coming down. See datasheet (VS6-LWC) 2.8.2 Voice Warning This is an audio and/or spoken multi message facility. The unit can give one customised up to 16 second message relayed when the curtain system activates or two 8 second customised messages relayed at different system events e.g. one message when the curtain activates and a different message when emergency retract is used. The default message is Warning, fire curtain descending See datasheet (VS6-VWR) 2.8.3 Building Management System Outputs The status of the fire curtain system can be monitored by the building management system with the optional BMS outputs. The following will be monitored: Ø Mains power status Ø Alarm status Ø Battery condition Ø Curtain Up Ø Curtain Down Ø Curtain fault 3 EXECUTION 3.1 Installation Coopers FireMaster NVS Horizontal Simplex Fire Curtains shall be installed by Approved Installers in strict adherence with the manufacturer s guidelines and the advice (if required) of their official representative. Ensure that the structure being fixed to is suitably fire rated and to the manufacturer s specifications. All Coopers FireMaster NVS Horizontal Simplex Fire Curtains shall be carefully located in the positions indicated on the approved Shop Drawings in perfect alignment, plumb, level, straight and true. Adjust the active fire curtain barrier assemblies to provide uniform clearances and smooth non-binding operation. Install all wiring to active fire curtain barrier assemblies in strict accordance with the manufacturers written instructions and AS/NZS 3000:2007 Wiring Rules. 3.2 Commissioning The installer shall perform suitable tests to ensure that the Coopers FireMaster NVS Horizontal Simplex Fire Curtains operate in accordance with the Contract Documents and this specification. Complete interface testing shall be performed between all associated trades to ensure that the Coopers FireMaster NVS Horizontal Simplex Fire Curtains work correctly in fire mode. At a minimum this will be between the fire alarm/s and automatic fire barriers. Product Specification - FireMaster NVS Horizontal Simplex Page 4 of 5

3.3 Maintenance The Coopers FireMaster NVS Horizontal Simplex Fire Curtains shall be included in the required Fire Safety Measures for the building and must be maintained in accordance with the manufacturer s recommendations. At a minimum the automatic fire barriers shall be inspected and maintained in accordance with AS1851 (2012) Section 13 which requires 6 monthly intervals. Maintenance and inspections shall be performed by fully trained and competent technicians. Product Specification - FireMaster NVS Horizontal Simplex Page 5 of 5