Course outline: 311 Cable Selection G107A UEENEEG107A - Select wiring systems and cables for low voltage general electrical installations

Similar documents
Course outline: 442 Capstone G105A UEENEEG105A - Verify compliance and functionality of low voltage general electrical installations

NZQA registered unit standard version 1 Page 1 of 5

UEE30811 Q-Tracker Work Tasks

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

ER 52 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) EA 147M(c)(i) (1 mark) EA 147M(c)(ii)

Neil Hewitt Electrical & Air Conditioning P/L

Australian/New Zealand Standard

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET

Electrical Management

Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734

ES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

Unit and Assessment Specification

Training, Assessment, Consultants for Hazardous & Industrial Areas

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

Qualifications Handbook. Fire and Rescue Services in the Community

NZQA registered unit standard version 1 Page 1 of 5

Qualification Specification Highfield Level 1 Award in the Principles of Fire Safety Awareness (RQF)

Guide to Membership Assessments

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of electrical installations in special situations

COMPETENCE. Lead Fire Warden. Standard Title Lead Fire Warden Competence Assessment Standard Lead Fire Warden Competence Assessment Standard

User Information Sheet 008 : 2010

Fire prevention and protection

NZQA unit standard version 2 Page 1 of 6. Perform installation and maintenance of telecommunications radio systems and services

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

Electrical Safety Requirements

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

Other Name. Country of Birth Are you an Australian Resident Y N

Level 3 NVQ Diploma in Heating and Ventilating Industrial and Commercial Installation ( )

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

Fire prevention and protection

Fire Safety. A TUC guide for trade union activists

National Certificate in Fire Detection and Alarm Systems (Level 4) Level 4

Information for persons seeking acceptance as Independent Qualified Persons (IQP)

QUALIFICATION SPECIFICATION

NZECP 19: 1994 ISSN COVER PAGE

Fire Protection Accreditation Scheme (FPAS)

NZQA registered unit standard version 2 Page 1 of 5. Use painting and decorating tools and equipment

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Prereq: FOD 131 or Instructor Permission

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

Interior design. Some people look for a beautiful place, others make a place beautiful RTO hazrat inayat khan

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 7 May 2016 QUESTION AND ANSWER BOOKLET

Australian/New Zealand Standard

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

EMERGENCY LIGHTING COMPLETION CERTIFICATE For small installations and verification of existing installations

WER Training Program. Level 4

Level 3 NVQ Diplomas in Heating and Ventilating ( /31/32)

NZQA registered unit standard 5897 version 3 Page 1 of 5. Design electronic security intruder alarm systems

1. EXPLORE A CAREER PLAN IN DESIGN AND MERCHANDISING

AS/NZS IEC :2013

Electrical Protection and Transportation Installations for Non-domestic Buildings

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Interior Industrial Fire Brigade Member- NFPA 1081, 2007

Prerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing instrument.

Transition to NFPA Professional Qualifications Standards: OFMEM Grandfathering Policy. Office of the Fire Marshal and Emergency Management (OFMEM)

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

Qualification Specification. Fire Marshall I N G A W A R D S I N T R A S A F E T Y S R D S A F E T Y T A W A. Version

Fire Protection, Inspection and Testing Qualifications Forums. Jeremy Rose (Artibus Innovation) Chris Wyborn (FPA Australia)

If there are more than ten people working other than on the ground floor,

Fire Safety Policy Date: 0

NZQA registered unit standard version 4 Page 1 of 5

Eaton training solutions Accredited CPD seminars. LED Emergency and Mains Lighting Contents. Knowledge for your business

National Certificate in Fire and Rescue Services (Vegetation) (Level 4)

WER Training Program. Level 3

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

Requirements for Electrical Installations

Electronic Fire and Security Systems: Intruder and Hold-Up Alarm Systems Installation (SCQF level 6)

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018.

Upon completion of this course, the student will be able to:

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

Fire Safety Awareness

No previous protocol.

CHAPTER Committee Substitute for Committee Substitute for Senate Bill No. 562

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Safety Strategy

PERIODIC ELECTRICAL TESTING POLICY

Information Bulletin

BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

NZQA registered unit standard 5881 version 6 Page 1 of 5. Demonstrate knowledge of electronic security devices

AS/NZS :2008

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Electronic Fire and Security Systems: Fire Alarm Systems Installation (SCQF level 6)

Model Curriculum Airport Fire Prevention Crew

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

SYLLABUS. Departmental Syllabus. Fire Protection Equipment Alarm Systems. Departmental Syllabus. Departmental Syllabus. Departmental Syllabus

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

Transcription:

RTO Code 41319 Course outline: 311 Cable Selection G107A UEENEEG107A - Select wiring systems and cables for low voltage general installations Qualification: Applicable to: Unit of competency: Related policies: Monitor and review: Responsibility: Certificate III in Electrotechnology Electrician - UEE30811 Learners, industry/employers, governments, community and Global Energy Training Solutions as the provider Accessible from: http://training.gov.au/training/details/ueeneeg107a Policy & Procedure 1 Enrolment Policy Policy & Procedure 2 Credit Transfer & Recognition of Prior Learning Policy & Procedure 3 Learner Support Policy & Procedure 4 Assessment Policy & Procedure 5 Academic Misconduct Policy & Procedure 6 Alcohol & Other Drugs Policy & Procedure 7 Access, Equity & Diversity Policy & Procedure 8 Vulnerable People Policy & Procedure 9 Work, Health & Safety Policy & Procedure 10 Incident, Injury & Rehabilitation Policy & Procedure 11 Competency, & Qualification Assessment Decisions Policy & Procedure 12 Complaints & Appeals Policy & Procedure 13 Privacy Policy & Procedure 14 Fees Policy & Procedure 15 Industry & Employer Engagement Policy & Procedure 16 Trainers & Assessors Policy & Procedure 17 Administration & Other Staff Policy & Procedure 18 Quality Assurance Policy & Procedure 19 Business & Financial Risk Management Policy & Procedure 20 Changes to Qualifications or Business Policy & Procedure 21 Conflict of Interest Policy & Procedure 22 Records Management Policy & Procedure 23 Marketing & Advertising Policy & Procedure 18 Quality Assurance Ben Murphy as Proprietor Questions/queries: Feedback and suggestions welcomed: office@gets.com.au (+61) 02 6262 0077 07/02/2017 311_Cable Selection_G107A_Course outline_v2 Page 1/5

Table of Contents 1. Material requirements...2 2. Session summaries...2 Day 1...2 Day 2...3 Day 3...3 Day 4...3 Day 5...3 Day 6...4 Day 7...4 3. Elements and Performance Criteria...4 4. Assessments...5 5. Version control...5 1. Material requirements AS/NZS 3000:2007 incorporating amendment 1 and 2 Scientific calculator, ruler, pens and pencils Note book Hand tools Covered footwear Internet access (provided) 2. Session summaries T1 Day 1 Performance requirements - design and safety encompassing: harmful effects against which the design of an installation must provide protection. performance standards of a correctly functioning installation. supply characteristics that shall be considered when designing an installation. acceptable methods for determining the maximum demand in consumer's mains and submains. AS/NZS 3000 requirements limiting voltage drop in an installation. reason for dividing installations into circuits and the factors that shall determine their number and type. typical external factors that may damage an installation and that shall be considered in the installation design. methods for protecting persons and livestock against direct and indirect contact with conductive parts and the typical application of each. acceptable methods of protection against the risks of ignition of flammable materials and injury by burns from the thermal effects of current, in normal service. likely sources of unwanted voltages and the methods for dealing with this potential hazard. acceptable methods for protecting persons and livestock against injury and property against damage from the effects of over current. requirement for protection against fault current. requirement for protection against the harmful effects of faults between live parts of circuits supplied at different voltages. need for protection against injury from mechanical movement and how this may be achieved. 07/02/2017 311_Cable Selection_G107A_Course outline_v2 Page 2/5

features of 'fire rated construction' and how the integrity of the fire rating can be maintained in relation to installation. T2 Day 2 Final subcircuit arrangements encompassing: factors that shall be considered in determining the number and type of circuits required for an installation. daily and seasonal demand for lighting, power, heating and other loads in a given installation. number and types of circuits required or a particular installation. current requirements for given final subcircuits. layout/schedule of circuits for given installations. T3 T4 Day 3 Factors affecting the suitability of wiring systems encompassing: wiring systems typically used with various construction methods and particular environments. installation conditions that may affect the current-carrying capacity of cables. external influences that may affect the current-carrying capacity and/or may cause damage to the wiring system. AS/NZS 3000 requirements for selecting wiring systems for a range of circuits, installation conditions and construction methods into which the wiring system is to be installed. Note: Wiring systems include cable enclosures, underground wiring, aerial wiring, catenary support, emergency systems, busbar trunking and earth sheath return. Day 4 Maximum demand on consumer s mains/submains encompassing: acceptable methods for determining the maximum demand on an installation s consumer s mains and submains. maximum demand for the consumer's mains for given installations up to 400 A per phase. maximum demand for given submains. T5 Cable selection based on current carrying capacity requirements encompassing: installation conditions for a range of wiring systems and applications. external influences that require the use of a derating factor. AS/NZS 3000 requirements for coordination of cables and protection devices. AS/NZS 3008 used to select conductor size based on the maximum current requirement for a given installation condition including any applicable derating factors. T6 Day 5 Cable selection based on voltage drop requirements encompassing: AS/NZS 3000 requirements for maximum voltage drop in an installation. relevant tables in AS/NZS 3008 for unit values of voltage drop. calculation of the expected voltage drop in a given circuit. selecting cables to satisfy voltage drop requirements in addition to current carrying capacity requirements. T7 Cable selection based on fault loop impedance requirements encompassing: AS/NZS 3000 requirements for maximum fault loop impedance in an installation. relevant tables in AS/NZS 3008 to determine cable impedances. calculation of the expected fault loop impedance for a given circuit arrangement. selecting cables to satisfy fault loop impedance requirements in addition to current carrying capacity requirements and voltage drop requirements. 07/02/2017 311_Cable Selection_G107A_Course outline_v2 Page 3/5

T8 Day 6 Selecting protection devices encompassing: acceptable methods of protection against indirect contact. AS/NZS 3000 requirements for selecting methods and devices to protect against indirect contact for a range of installation types and conditions. coordination between conductors and protection devices to ensures the protection of cables from over heating due to over current. possible injuries to persons and livestock from hazards due to a short circuit. AS/NZS 3000 requirements for selecting devices to protect against overload current for a range of circuits and loads. AS/NZS 3000 requirements for selecting devices to protect against short-circuit current for a range of installation conditions. T9 Selecting devices for isolation and switching encompassing: requirements for the provision of the isolation of every circuit in an installation. need for protection against mechanical movement of ly activated equipment. AS/NZS 3000 requirements for selecting devices for isolation and switching for a range of installations and conditions. Day 7 T10 Switchboards encompassing: AS/NZS 3000 and local supply authority requirements for switchboards. tariff structures for the supply of electricity. equipment installed at the main switchboards with capacities up to 400 A per phase. layout of a main switchboard for an installation supplied with single phase single tariff whole current metering. layout of a main switchboard for an installation supplied with single phase multiple tariff whole current metering. layout of a main switchboard for an installation supplied with multiphase single tariff whole current metering. layout of a main switchboard for an installation supplied with multiphase multiple tariff whole current metering. layout of a main switchboard for a multiple tenancy installation with whole current metering. layout of a main switchboard, including metering, for an installation supplied with three phase CT metering. local supply authority requirements for connection of an installation to the supply system 3. Elements and Performance Criteria Elements and Performance Criteria require practice and demonstration in the work place. Element Performance Criteria Work Performance 1:Prepare to select wiring systems and cables for general installations. 1.1 1.2 1.3 The extent and nature of the installation is determined from job specifications. Safety and other regulatory requirements to which the installation shall comply area are identified, obtained and understood. Cable routes, the route lengths of cables and the conditions in which the wiring system is to operate is determined from job specifications or from consultation with appropriate persons. 07/02/2017 311_Cable Selection_G107A_Course outline_v2 Page 4/5

2.1 Wiring systems are selected for suitability for the environments in which they are to operate. 2:Select wiring systems and cables for general installations. 2.2 2.3 2.4 Cable conductor sizes are selected to meet current-carrying capacity requirements and voltage-drop and earth fault-loop impedance limitations. Circuit protective devices are selected to meet requirement for coordination with conductor current-carrying capacity. Earthing system components are selected to meet requirements of an MEN system. 2.5 Evidence is obtained that equipment selected complies with safety requirements. 3.1 Evidence is obtained from manufacturers/suppliers that equipment selected complies with safety requirements. 3:Document installation. 3.2 Reasons for selections made, including calculations, are documented in accordance with established procedures. 3.3 Electrical installation arrangement and specifications for all selected items are documented in accordance with established procedures and forwarded to appropriate person(s). 4. Assessments Assessment When Satisfactory mark/outcome Theory assessment 1 Day 4 70% Theory assessment 2 Day 5 70% Theory assessment 3 Day 6 70% Theory assessment 4 Day 7 70% Practical assessment 1 Day 7 100% Workplace Observation Employer Competency report Structured workplace experience interview After theory and practical assessments Must be valid, sufficient, authentic and current Note: Once all theory, practical and on-site assessments are complete, competency assessment decisions can be made in conjunction with the learner, employer and registered training organisation. 5. Version control Version Date of release Author Authorised by Position Rational for change V1 5/10/2015 Ben Murphy Ben Murphy Proprietor Initial release V2 7/2/2017 Ben Murphy Ben Murphy Proprietor Added Elements and Performance Criteria 07/02/2017 311_Cable Selection_G107A_Course outline_v2 Page 5/5