THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

Syclone Amalgam Separator Installation and operating guide

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

Industrial Vacuums, Inc

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Owner s. 18 Misting MF18W. To view

FLASH XTRACTOR II NEXT GENERATION SUB-SURFACE FLOOD EXTRACTION TOOL AC002

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

O w n e r s M a n u a l

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

Xaact Spot. Xaact Hot Spot

Manual Parts Washer. Operating Instructions & Warranty Information

Ozone + UV Sanitation

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Owner s Manual Hydro-X Vacuum Pac

Wax Base Heater & Dispenser

MDV. Mixing Degas Vessel. For Spa Ozone Generators Installation & Operations Manual Rev.C

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

A2Z Ozone, Inc. PRODUCT MANUAL

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION

(The chances are you re never going to read me) Owner s Manual.

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC015 - AC016 - AC018

Owner s. Coolerr. comply. To view

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

Owner s Manual. Terpene Trap CF 1000

MaxLite LED MICRO-T PANEL

Sound Cover [ , , , ]

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

O w n e r s M a n u a l 1

Navigator Upright Vacuum NV70 Series

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

C-Box 100, H-Box 200 & H-Box 500

Manual Feed Slot Opening. Wastebin. Credit Card Casters

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

Model 9000 Countertop Steam Distiller

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

TUBULAR LLdia-PUMPyy INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

(The chances are you re never going to read me) Owner s Manual.


OWNE R S MA N UA L. Made in USA. September 2015

Nilfisk Model VHS255 Drum Top Vacuum

ELECTRIC STOVE HEATER Models: FS2213B

OWNER S MANUAL & WARRANTY

MODEL 7000 SUCTION UNIT


Home Theater Interface Plate INSTALLATION INSTRUCTION

O w n e r s M a n u a l

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

ULTRASONIC humidifier

O w n e r s M a n u a l 1

2001 Smith Eastern Corporation

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

DUST FREE CARBON Whole House Air Purifier

Instruction Manual for Meat Grinder XMCA-SS

HW-17 Record Cleaning Machine Setup and Instruction Manual

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

DEHUMIDIFIER. User Manual 50BT, 70BT

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

SINGLE MOTOR UPRIGHT VACUUM CLEANER MODEL C

ion Genesis Pump Controller

SeaLand. GRAVITY DISCHARGE Toilet WARNING. SeaLand Toilet Models 110 and 210

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

InstructIon Manual KrEs EQuIPMEnt stands

6 Sheet Strip-Cut Shredder for Home/Office

V. (Versus ) Bare Floor Vacuum

IMPORTANT! ank You! Model: Twist-In 100 GPD, 3-Stage RO Unit. Installation, Operation & Maintenance Guide

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

No Touch Door Release Exit Sensor ACA-NTEB

GETZ MANUFACTURING PART # CYLINDER DRYER

FREESTYLE PRO CORDLESS SV1112. Series INSTRUCTIONS. sharkclean.com

IC6-B, IC6-MB, IC6-BB, IC8-B, IC8-MB, IC8-BB, ICA6-B, ICA6-MB, ICA6-BB, IC6DVC-B, BS650 ICS6-MB, ICS8-MB

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

TrueClean ToteCleaner

2h 4h 6h. Ultrasonic Humidifier CAUTION: READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION.

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Instruction Manual for Meat Grinder XMCA-SS

H-16.5 Record Cleaning Machine Setup and Instruction Manual

Product View. Assembly. Operation. Maintenance and Care. Troubleshooting. Consumer Services. Replacement Parts. Additional Accessories.

Washable HEPA Air Cleaner with PlasmaWave Technology

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

OPERATION, SERVICE & PARTS MANUAL

Here is what comes in your box:

Transcription:

Hg5 Amalgam Separator Installation and Operations Manual

Thoroughly read and understand instructions prior to installing, operating and servicing the RAMVAC Hg5 Amalgam Separator. These instructions are also available on our website at www.dentalez.com/downloads. 2 The waste stream treated by the RAMVAC Hg5 is discharge from a dental vacuum system and as such may contain concentrations of solid and soluble mercury and silver. Always wear protective gear when handling full RAMVAC Hg5 collection containers (latex gloves, safety glasses or face shield) and dispose of per local regulations and codes. Warranty WARNING Full collection containers should be handled, stored and disposed of according to regulations applying to hazardous waste containing mercury. Any spills should be considered hazardous and should be handled in accordance with standard hazardous materials handling procedures. Limitations of Warranty! RAMVAC Hg5 Air Water Separators are warranted against defects in material and workmanship for a period of two (2) years from the date of purchase, established by proof of purchase or formal warranty registration. During the warranty period, DentalEZ will at its option repair or replace products that prove to be defective. RAMVAC Hg5 Collection Containers are warranted against defects in material and workmanship for a period of one (1) year from the date of purchase, established by proof of purchase or formal warranty registration. During the warranty period, DentalEZ will at its option repair or replace products that prove to be defective. Labor, transportation and service charges are not included. The warranty shall not apply to defects resulting from improper installation, maintenance, abuse, unauthorized modification, or operation outside of the environmental specifications for the product or damages that occur due to improper repackaging of equipment for return to DentalEZ. Use of third party collection containers or line cleaners having a ph less than 6 or greater than 10 will void these warranties. Solmetex approves RAMVAC Slugbuster line Cleaner Formulated for amalgam separator systems and is Manufactured by DentalEZ. No other warranty is expressed or implied. DentalEZ specifically disclaims the implied warranties of merchantability and fitness for particular purpose.

RAMVAC Hg5 Amalgam Separator Initial Set-Up The RAMVAC Hg5 Amalgam Separator is a Type 2 device with a maximum flow of 1000 ml/min and maximum fillable volume of 950 ml 1. TOP BRACKET Leave bolts loose enough to adjust bracket height. BOTTOM BRACKET Slide to highest position and tighten until snug. 2. A. Engage slot on pin (see detail). Rotate assembly into place (keeping slot engaged on pin). Push top bracket down over tabs until unit is secured in place. B. Tighten top bracket bolts until snug. 3. When installing the collection container: remove red caps from the top of the collection container, if applicable. Detail: Slot must fully engage pin on lower bracket. Attach collection container to Hg5 Lock into place with retaining pins. RAMVAC Hg5 Amalgam Separator 3

RAMVAC Hg5 Installation tips Installation tips: Place in an easily accessed location for replacement of collection container. Place between treatment rooms and vacuum source. DO NOT connect to outlet of separating tank or water ring pump. The RAMVAC Hg5 should be installed so that the outlet is higher than the tank or pump inlet. Use provided inlet and outlet couplings. DO NOT glue plumbing to the RAMVAC Hg5 inlet and outlet. Securely mount or support the baseplate. If mounting to a wall, use the four (4) plastic standoffs (included), one on the back of each hole in the baseplate. If attaching to the floor, the four (4) plastic standoffs will not be required to be used. Write the installation date on the collection container. Complete the registration form and return. Environmental Specifications: Overall Dimensions: 11" W x 29" H x 8" D One RAMVAC Hg5 will serve up to 10 chairs. Minimize water lift height. Maximum Temperature = 120 o F (52 o C) Maximum Vacuum = 15" Hg (51 kpa) For dental use ONLY. Treatment Rooms Hg5 Inlet Tank Inlet DO NOT connect Hg5 to outlet of tank. Dry Vacuum Unit OR Functional with 15, 30, or 50 Gallon Tank And with Single or Dual Wet Ring Pumps Hg5 Outlet Pump Inlet 4 DO NOT connect Hg5 to outlet of the water ring pump.

Collection Container Your collection container must be changed once every twelve (12) months or when the sediment level reaches the full line, whichever occurs first. Check the sediment level of the collection container weekly. Maintenance Line rinsing & vacuum line cleaners - cleaners should be: Non-foaming, de-odorizing, sanitizing & ph between 6 and 10. Using Line Cleaners outside of this ph range will void the warranty. Solmetex approves RAMVAC Slugbuster line Cleaner Formulated for amalgam separator systems and is Manufactured by DentalEZ. With Dental Vacuum Systems: Follow manufacturers instructions. Plan to rinse no more than 5 chairs every 10 minutes. Limit the total maximum flow to the RAMVAC Hg5 during rinsing to 1 liter per minute. Rinsing too much or too rapidly can overfill the RAMVAC Hg5 and could affect the unit s efficiency. Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. DentalEZ shall not be liable for any direct, indirect, special, incidental or consequential damages, whether based on contract, tort or any other legal theory. Service The RAMVAC Hg5 is designed to provide years of trouble-free service, with minimal attention. In the unlikely event of system related problems, please review the Q&A or troubleshooting section. Q&A: Little or no vacuum at the hand piece. 1. Check sediment level of collection container, if full change the collection container. 2. If the vacuum gauge reads normal but there is little or no vacuum to the hand piece, there is probably a clog or a leak between the hand piece and the RAMVAC Hg5. 3. If the vacuum gauge reads lower than normal these are the possible causes: Did you just replace the collection container? Yes: Check installation of the new collection container. If the vacuum is low there is a possibility that the o-rings on the collection container did not seal into the receivers. With the vacuum running, remove the collection container, check the o-rings and re-install per the collection container installation procedure. No: If you have a solids collection cup (installed by others) - check & clean or replace element/screen if necessary. RAMVAC Hg5 Amalgam Separator 5

6 Service continued Check operation of the vacuum pump. Listen for vacuum leaks. Check all connections for breaks or cracks. Check all flexible hose for kinks, breaks, or loose clamps. Q&A: Water in the upper chamber (Air Water Separator) 1. Check sediment level of collection container, if full change collection container. 2. Check the ph of vacuum line cleaner, if below 6 or above 10 change collection container and line cleaner. RAMVAC Slugbuster line Cleaner is an appoved line cleaner. 3. Call or email your dental dealer for support if the problem cannot be solved easily. Troubleshooting NOTICE Refer to RAMVAC Hg5 Collection Container Replacement & Recycle Procedure manual at www.dentalez.com/hg5 for removal of container. Always wear protective gear when handling full RAMVAC Hg5 collection containers. Keep the vacuum system running during the entire collection container replacement procedure. This procedure should be performed only when no operatories are being used as loss of chairside vacuum may occur. Solids reach full line of collection container. Change the collection container. Solids are above full line of collection container. Change the collection container. Inspect the top chamber for solids. Top chamber has some solids. System is backed up. Turn on vacuum Remove pins Tilt container towards manifold to allow air into top chamber Place container back on and insert pins Top chamber is full with solids. System is in bypass. Reduction in suction Solids released into waste stream and environment Top chamber needs to be replaced Full top chamber needs to be recycled The equipment/utility room has poor lighting. Bring a flashlight to check the container. Using a flashlight from the backside of the system and shining it forward will help determine the level of sedimentation. This can also be used to inspect the top chamber using the same procedure.

Visual Inspection Log Visual Inspection Log for monthly maintenance reporting. Easy to use, print the pdf document and place next to your RAMVAC Hg5 system to be dated and signed once a month. This will help keep the dental office in compliance with amalgam waste management. Document can be found on http://www.dentalez.com/downloads Visual Inspection Log Operations and Maintenance Plan Use for the RAMVAC Utility Hg5 Amalgam Separator to ensure proper operation and maintenance plan. Visual inspection of separator once a month with date and signature. Collection container to be replaced when solids reach the full line or once a year, whichever comes first. Office Name: Account Number: Hg5 Series of Amalgam Separators Date (MM/DD/YYYY) Signature 866-DTE-INFO, Opt 4 Additional documents: www.dentalez.com/hg5log RAMVAC Visual Inspect 061516 RAMVAC Hg5 Amalgam Separator 7

866.DTE.INFO, opt. 4 Ramvac Hg5 Install Ops Manual 2016 Rev 3 Hg5 is a registered trademark of Solmetex LLC