WARNING FIRE DOOR CLOSING

Similar documents
PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

FirePro control MANUAL

Installation, Operating and Maintenance Manual

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Application, Installation, Operation & Maintenance Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

5000 SERIES 8 ZONE INSTRUCTION MANUAL

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Premier Hazard STC Instructions

Reflective Optical Beam Smoke Detector User Guide

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Intelligent Security & Fire Ltd

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

Silent Alert Fire Safe System

169MHz Telecare Devices Gas & Carbon Monoxide Detector

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Door Release Power Supply

New Silent Alert Fire Safe System

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

RS-1 Roller Door Remote Control Unit

Installation & Programming Guide

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

FIRERAY 5000 range USER GUIDE

CONTROL DEVICE SLIDETRONIC HD

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 USER S MANUAL

DYGIZONE GJD910 Lighting Controller & Enunciator

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

TABLE OF CONTENTS TABLE OF CONTENTS 1

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Instructions for the fan motor control system with integrated wiring terminals SILVER C

FEC400 Series. Installation Manual

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

OPERATION AND INSTALLATION MANUAL

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Programming the Vi+ using a Series Telephone. Tunstall Vi+

Scantronic Leading the way in security

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

HILLS Series LED Code Pad User Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

User s Information Guide R2A

EXTINGUISHING AGENT RELEASE MODULE

169MHz Telecare Devices. Gas Detector

System Introduction. 1.1 Specifications S E C T I O N 1

Salamander User Guide

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Emerald 3000 MK3 GJD010 Lighting Controller

Secure WANDERING INSTALLATION AND USAGE GUIDE

Excel-EN Conventional Fire Control Panel

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

Control Panel User Guide

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

AL600ULADA. NAC Power Extender. Installation Guide

CA60Plus. Installation manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Auto Dialer. Manual E-921APQ E-921GPQ

Fire Control Panel FS4000

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Intruder - Fire - Water Combined Alarm

Operation and Maintenance Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Please read this sheet as it contains important information

GAS SUPRESSION CONTROL PANEL:

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

FIRE ALARM CONTROL PANEL FVC01-08

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Radio fire warning panel SRC 3000

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Fire Command Keypad. XR5 User s Guide

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

LEAKSTOPPER RANGE Multizone water leak detection systems

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

Transcription:

PRODUCT INSTRUCTIS Stock Code: 088 FCP - Lite Floats Road, Wythenshawe Manchester, M 9WB Tel: + (0) 9 Fax: + (0) 9 Doc No PI - 88 Iss:.0 WARNING FIRE DOOR CLOSING STOP

Contents ) Blank ) Features and Specification... ) Installation... ) General Board layout... ) Connections.... 0V Mains Power. 0V Tube Motor. External Push Button (When mounted at High Level). External Key Switch (When mounted at High Level). Keypad (GEBA Quadraline). Radio Control (GEBA).7 Photocell.8 8k Resistive Safety Edge.9 Optical Safety Edge.0 N/O Fire Signal (Normally Open). N/C Fire Signal (Normally Closed). Panic Button. Fire Alarm Auxiliary Relay. Door Travel Status Relay ) Operation.... Motor Set Up Feature 7) Switch Settings... 7. General Functions 7. Run Timer 7. Auto Close Delay Timer 7. Audio Visual Delay Timer 8) Display Status... 9) Troubleshooting...

) Features and Specification Control System for Roller Shutters and Smoke curtains Features Large visual warning 'FIRE SHUTTER CLOSING' and 90 db sounder Asymmetrical box for top or bottom cable entry Operation by either on membrane buttons or External push button / key-switch connection Operation by "Impulse Open / Close for use with safety devices or "Impulse" Open / "Dead-man Close if no safety devices are present "Dead-man" Open / Close feature to assist motor limit set up Low Voltage control circuit Easy to program using switches Motor Run Timer up to 9 sec's for extra motor protection Automatic closing facility with Delay Time up to 9 sec's Keypad Input option (090) Status relay for door running Radio control option (Receiver 8) (transmitter: ch - 8, ch - 8,or ch - 8) Door closing under Mains Power in the event of a fire Audio/Visual Warning activation for up to sec's Panic Button option for emergency escape Choice of fire signal activation either by Normally Open (N/O) or Normally Closed (N/C) contact Fire Alarm Conformation Relay Internal status and fault code display Conforms to EN Power Supply Requirements A 0v AC 0Hz Mains power supply must be provided for the unit to operate This can be supplied by: A direct connection to a A fused spur (or) A suitable sized Battery Back Up Unit sized correctly for the Tube motor to give a emergency supply A total loss of 0v mains power will prevent any motor operation, even in the event of a fire Normal Operating Conditions Opening and closing the shutter on a normal day to day operation will be carried out either by: An external Key-Switch or Push Button station if mounted at High Level The membrane push buttons fixed to to the lid if mounted at low level and local to the shutter Shutter control in either Impulse Open/ Close or Impulse Open/Dead-man Close modes Fire Condition By activation of a connected "normally open" (N/O) or "normally closed" N/C volt free fire signal, the panel will begin an audio/visual warning This warning will continue for a pre-set delay time (up to sec's) during in which time no motor action will take place Upon expiry of the warning, the shutter will begin to drive down and stop at the bottom position All safety devices will be disabled At the closed position the audio/ visual warning will stop The shutter will remain closed all the time the fire alarm signal is present and cannot be re-opened by any normal controls e.g Key-Switch, Pushbutton station except by the panic button facility (if fitted) Power Supply 0v - 0Hz Max Motor Load A @ 0v, 0 Watts Max Accessories Load 0mA @ v d.c Working Temp -0 to + C IP Transmitter Qty 0 Transmitter Frequency No of possible Keypad codes ( or digit) Dimensions (mm) Weight (Kg).9MHz 0 0 (l) x (w) x (h). (Approx)

) Installation Mounting Mount the unit using the fixing holes provided (Fig.) WARNING FIRE DOOR CLOSING 70 X STOP Cable Entry The "FCP Lite" is designed so the cable entry can be positioned at the top or bottom of the panel by means of removing the PCB fixing screws, then rotating either board or box 80 and refitting (Fig.) UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open OUT X OUT 7 7 The enclosure should be mounted vertically and secured using the provided fixing holes (see fig.) Consideration must be given to the incoming cables and the panel rotated accordingly to give top or bottom entry (see fig.) To protect both motor and personnel, this product must be connected to a suitable EARTH point All electrical work should be undertaken by a suitable competent person Lid Removal To Remove Lid remove Fixing screws 'A' (Fig.) 'A' 'A' 'A' 'A' 'B' 'B' 'B' 'B' UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open 'B' N L PE PE N L C UP DWN Motor M Light 'B' 'B' N L PE PE N L C UP DWN Motor M Light 'B' BOTTOM CABLE ENTRY TOP CABLE ENTRY

) General Board Layout Function Settings Run Time Settings Fire Alarm Condition Settings Auto-Close Timer Settings Radio Reciever (GEBA) 7 X Panic Button Fire Alarm Signal Program Button Membrane Push Button Close Open UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Safety Edge Photocell Key pad (GEBA) Ext. PushButton / Keyswitch Connections OUT Fire Alarm Auxiliary Relay Door Travel Status Relay N L PE PE N L C UP DWN Light Motor M Mains Power Supply 0v AC 0Hz Motor Control Connection

) Connections.) 0 Volt Mains Power N L PE Mains Power Connection PE = EARTH (Grn/Yel) L = LIVE (Brown) N = NEUTRAL (Blue) Use these terminals as a direct connection for 0v (ph) Mains power supply to the 'FCP Lite' Controller This connection should connected to a be fused spur or outlets rated at A (max) 0V Mains Supply.) 0v Tube Motor Connection Connection to a typical 0v Tube Motor PE = EARTH (Grn/Yel) N = NEUTRAL (Blue) UP = OPEN DIRECTI (Brown) DWN = CLOSE DIRECTI (Black) PE N L C UP DWN Motor M Black Brown Blue Green / Yellow }Tube Motor Use these terminals as a direct connection for a tube motor to the 'FCP Lite' Controller Note: The voltage feed link between "L" and "C" must remain fitted 7

Open UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open Close Stop Common Remove factory fitted link and connect Push Button Station X.) Ext. Push Button Control (Optional) Push Button Notes Normal Operation. An external connected "Push Button Station" will fully control the operation of the shutter OPEN, STOP, CLOSE. It will remain "continually" active during normal operation Fire Condition Operation. On receipt of a fire signal, the "Push Button Station" is "disabled" and the shutter will continue to run to the fully closed position. There will be no function from "any button pressed" this includes the STOP button. The "Push Button Station" will remain inactive until the Fire Signal is removed or reset 8

.) Ext. Key-Switch (Optional) UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open X Keep factory fitted link and connect Keyswitch Common Close Open Key-Switch Notes Normal Operation. An external connected "Key-Switch" will fully control the operation of the shutter OPEN, and CLOSE. It will remain "continually" active during normal operation Fire Condition Operation. On receipt of a fire signal, the "Key-Switch" is "disabled" and the shutter will continue to run to the fully closed position. There will be no function in any direction selected by the "Key-Switch". The "Key-Switch" will remain inactive until the Fire Signal is removed or reset 9

.) Keypad (optional) UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open X GEBA Quadraline Keypad 0 STOP 7 8 9 Turn (switch ) =, when complete Enter chosen code ( or digit) and press once, unit will emit bleeps The entered code will briefly show in the display then return to the next memory location Turn (switch ) =, display will show available memory location, e.g 0 To Program Keypad - Notes Normal Operation. Upon entering a chosen code, the "Keypad" will OPEN, STOP or CLOSE a door. To operate enter code then press the "key" button (This will keep the "Keypad" active for 0 seconds). Press either 9 to OPEN, 7 to CLOSE, STOP or to STOP 0 Fire Condition Operation. On receipt of a fire signal, the "Keypad" is "disabled" and the shutter will continue to run to the fully closed position. There will be no function in any direction selected by the keypad. The "Keypad" will remain inactive until the Fire Signal is removed or reset 0

.) Radio Control operation (optional) Transmitter programming 7 T Radio Reciever. V Emerg GND SKS V Prelim Close Open X Plug in the "Radio Receiver" where shown Turn (Switch ) to The display now shows Press and hold the button on the "Transmitter" for second, the DC will bleep once The "Transmitter" is stored and the display will advance by one digit this is the next location to be used Repeat for each "Transmitter" to a maximum of 0 handsets Note: Number 0 transmitter location will be shown as thus Radio Control is only available if all safety devices are connected Once all "Transmitters" have been entered switch must be switched off Transmitter deleting 7 T Radio Reciever. V Emerg GND SKS V Prelim Close Open X Turn (switch ) to The display now shows the last location to be used e.g.. 7 Using the programming button T on the DC controller, scroll through the display to the location to be deleted Press and hold the programming button T the DC will bleep twice this location is now empty Repeat as necessary Programming Button

UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open Black Grey not used White com n/c Brown Blue +v dc 0v Note: Wire colour may vary White Black Brown Blue Remove factory fitted link from N/C terminals and connect Photocell X.7) Photocell Connection (Optional) Photocell Notes Normal Operation. The "Photocell" will stop and re-open a closing door. It will remain active for the length of the "Run Time" set by ( ),. It is recommended the "Run Time" is set sec's longer than the actual Door Travel Fire Condition Operation. On receipt of a fire signal, the "Photocell" is "disabled" and the shutter will continue to run to the fully closed position. The "Photocell" will remain inactive until the Fire Signal is removed or reset

.8) 8k Resistive Safety Edge Connection (Optional) UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open X Note: Wire colour may vary Brown White For 8k Resistive Safety Edge = 8.k Remove factory fitted resistor and connect safety edge Switch (prog I) = 8k Resistive Safety Edge Notes Normal Operation. The "8k Resistive Safety Edge" will stop and re-open a closing door. Should the Auto-close delay timer be set the door will then re-close. If the obstruction is detected consecutive times before before the close position is reached - then on the next detection the door will re-open a short distance and stop, the obstacle must then be removed before any further operation Fire Condition Operation. On receipt of a fire signal, the "8k Resistive Safety Edge" is "disabled" and the shutter will continue to run to the fully closed position. The "8k Resistive Safety Edge" will remain inactive until the Fire Signal is removed or reset

UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open Switch (prog I) = Remove factory fitted resistor and connect safety edge Transmitter Receiver White Green Brown X For Optical Safety Edge =.9) Optical Safety Edge Connection (Optional) Optical Safety Edge Notes Normal Operation. The "Optical Safety Edge" will stop and re-open a closing door. Should the Auto-close delay timer be set the door will then re-close. If the obstruction is detected consecutive times before before the close position is reached - then on the next detection the door will re-open a short distance and stop, the obstacle must then be removed before any further operation Fire Condition Operation. On receipt of a fire signal, the "Optical Safety Edge" is "disabled" and the shutter will continue to run to the fully closed position. The "Optical Safety Edge" will remain inactive until the Fire Signal is removed or reset

.0) Fire Signal connection Normally Open (N/O) Volt Free signal N/O volt Free Signal UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open X 7 7 = N/O (normally open) Volt Free Fire Signal - Notes Fire Condition Operation. This signal is selected by (7 = ). On receipt of a fire signal, all directional controls and the photocell is "disabled". The panel will being flashing and emit an audible tone. This Audio visual warning will continue for the time set by (switches - ). When this time has elapsed the shutter will begin to close and will continue to drive to the fully close position or as far as practical (should an obstruction be present), there will be no means of interruption providing the mains power supply remains

UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open 7 = 7 X N/C volt Free Signal.) Fire Signal connection Normally Closed (N/C) Volt Free signal N/C (normally closed) Volt Free Fire Signal - Notes Fire Condition Operation. This signal is selected by (7 = ). On receipt of a fire signal, all directional controls and the photocell is "disabled". The panel will being flashing and emit an audible tone. This Audio visual warning will continue for the time set by (switches - ). When this time has elapsed the shutter will begin to close and will continue to drive to the fully close position or as far as practical (should an obstruction be present), there will be no means of interruption providing the mains power supply remains

.) Panic Button Connection (optional) Panic Button UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Open Panic Button Notes Normal Operation. The "Panic Button" is "disabled" during Normal Operation and will not function Fire Condition Operation. The "Panic Button" will only become operational in a fire condition. On receipt of a fire signal the shutter will drive to the fully closed position and the "Run Time" set by (Switches - ) must be expired. Upon pressing the Panic Button the shutter will re-open to the fully open and the "Run Time" set by (Switches - ) must be expired. The shutter will pause for seconds, then re-close Once the fire alarm signal is reset the "Panic Button" will no longer function X 7 7 = 7

X UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close N/O contact going closed upon receipt of fire signal.) Fire Alarm Auxiliary Relay Connection (optional) Fire Alarm Auxiliary Relay" Notes Normal Operation. The "Fire Alarm Auxiliary Relay" is "disabled" during Normal Operation and will not operate Fire Condition Operation. The "Fire Alarm Auxiliary Relay" will only become operational in a fire condition. Immediately upon receipt of a fire signal the relay will switch N/C This signal can be used to:. Trigger a second Panel etc. Provide an activation status. Switch on a device 8

.) Door Travel Status Relay connection (optional) Door Travel Status Relay Notes Normal Operation. The "Door Travel Status Relay" is "active" during Normal Operation and will only operate when the door is running Fire Condition Operation. The "Door Travel Status Relay" will be disabled in a fire condition This signal can be used to:. Activate a external sounder or Beacon to indicate the door is traveling. Trigger a second Panel etc. Switch on a device X UP DWN STOP C IMPULSE IN IN NC GND V Emerg GND SKS V Prelim Close Relay function when door running:- Flashing - (switch ) = Constant - (switch ) = N/O contact closing in normal operation 9

) Operation.) Motor Set Up feature 7 X = Prelim Close Open Motor Limit Set Up By selecting (switch = ) this sets the panel in Dead-man OPEN / CLOSE operation to give a more accurate control when setting the open and close travel positions for the motor Please note: Once the Travel Limits have been correctly set, switch must be turned back off, it must not be left on for normal operation Set ( Switch ) RT -"RUN TIMER" to correspond with door travel (see table for times ) 0

7) Switch Functions 7.) General functions Selects safety edge type Not used - keep in position Not used - keep in position Not used - keep in position Radio Transmitter Programming Keypad Programming Only use switches highlited 8k Safety Edge Optical safety Edge Not used - keep in position Extended Run TIme Scale (For UK) Not used - keep in position Constant Flashing Deadman operation for Motor Set Up Only use switches highlited Door Run Time (see Table "RT") Select as per table Door Auto-Close Delay Time (see Table "CT") Select as per table Only to be used if safety devices are fitted 7 7 Fire Alarm Delay Time (see Table) N/O Fire Signal N/C Fire Signal Select as per table

0" 7" 0" " " 9" " " 8" " " 7" 0" " " 9" 7.) Motor Run Timer The run time must be set slightly longer than the door travel " " 8" " " 7" 70" 7" 7" 79" 8" 8" 88" 9" 9" 97" " " 9" " " 0" 7" " " 8" " " 09" 0" 00" To set: (switch = ) Use "RT" (switch's - ) to select time 8" " " 7" 0" " " 9" 7" 7" 78" 8" 8" 90" 9" 9" 9"

To set: (switch = ) 7" 0" " " 9" " " 8" " " 7" 0" " " 9" " " 8" " " 7" 70" 7" 7" 79" 8" 8" 88" 9" 9" 97" 00" 0" 0" 09" " " 8" " " 7" 0" " " 9" " " Use "CT" (switch's - ) to select time 8" " " 7" 0" " " 9" 7" 7" 78" 8" 8" 90" 9" 9" 7.) Auto - Close Delay Timer This feature must only be used if " forms" of safety devices are fitted

0" " " " 8" " " 0" " 8" " " 0" 8" " " 0" 7.) Audio/Visual Warning Timer time 08" " 7" 7" 8" 88" 9" 9" 00" 0" " " 80" 8" Sets the Audio/Visualwarning 88" 8" 80" 7" 7" 8" " 0" " " 8" " 0" " " 8" 7 9" 00" 0" " " 0" " 8" " 0" " 8" " " 08" 9" Use (switch's - ) to select time To set:

8) Display Status Normal Operating Status Display Status Notes Door ready for operation (normally shows after power on) Door travelling in the OPEN direction Door at TOP position with RUN TIMER expired STOPPED Door travelling in the CLOSE direction Stop Button Pressed while the shutter is moving Open Button released while the shutter was moving in dead-man Down Button released while the shutter was moving in dead-man Door at BOTTOM position with RUN TIMER expired Fire Condition Status Display Status Notes Fire signal received Panel in Fire Condition If Shutter is closed - no audio/visual warning is activated If Shutter is open - audio/visual warning is activated

9) Troubleshooting Trouble shooting. Display Fault Cause Solution External Stop Button Pressed Release External Stop Button Door will not operate after power up Run Timer (RT) Switches not set Set Run Timer (RT) to correspond with door height Door Travels in "Dead-man" OPEN and CLOSE (prog) switch is Turn (prog) switch = Photocell activated or open circuit Check Allignment Check For Obstructions Door Travels in "Impulse" OPEN and "Dead-man" CLOSE Safety Edge activated or defective Check 8k resistor fitted to (GND) & (SIG) Check (prog) switch = Check Optical Safety Edge Check (prog) switch = Photocell or Safety device purposely disconnected to achieve this condition Run Time is shorter than shown in the table "RT" (prog) switch is Turn (prog) switch = (Extended run time for UK) Upon reciept of fire signal No Audio/Visual Warning with door in closed position Fire Alarm Activated Display Fault Possible Cause Emergency Stop Button Check and release any emergency stop buttons Check Factory fitted link Safety Edge Activated or Defective Factory fitted resistor disconnected (Switch ) wrong setting Safety Edge activated or defective Photocell Activated or Defective Factory fitted link disconnected Photocell activated or defective Relays Damaged Replace Unit

7