Air Conditioners. Technical Data FBQ-C

Similar documents
technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data FTXS-G

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

EEDEN technical data ERHQ AA. Altherma. Altherma

TABLE OF CONTENTS RMXS-E8V1B

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

TABLE OF CONTENTS ERSQ-AAY1

Air Conditioners Technical Data

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air Conditioners Technical Data

Air Conditioners. Technical Data FTY-H

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

for the retail market, hotels, restaurants and offices

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

Air Conditioners Technical Data

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Heating. Technical Data EEDEN ERRQ-AY1

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

Air Conditioning Technical Data RZAG-MV1

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

Air Conditioners Technical Data

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Air Conditioners. Technical Data RZQG-L

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Daikin air conditioners for your home, shops, restaurants and offices

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Purifiers. Technical Data MC70L

Fan Coil Units. Technical Data FWC-BT/BF

Air Conditioning Technical Data RZASG-MV1

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioners Technical Data

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air conditioners, heating & cooling for shops,restaurants and offices

Air Conditioners Heating & Cooling

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

EEDEN technical data EKRTR. Altherma. Altherma

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air conditioners, heating & cooling for the retailmarket and offices

for small rooms in multi application

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

technical data air conditioning systems RZQ B8W1B Split Sky Air

AIR CONDITIONERS, HEATING & COOLING for your home

TABLE OF CONTENTS ERHQ BAV3

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Air Conditioners Heating & Cooling

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Air Conditioners Heating & Cooling

Daikin leads the way:

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Concealed ceiling unit with medium ESP

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioners Heating & Cooling

Air Conditioning Technical Data AZAS-MY1

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

for your home FLXS-B Flexi type unit air to air heat pumps

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

for your home FTYN-GX FT(Y)N-F

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

EEDEN technical data ERHQ AA

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B

Daikin air conditioners for shops, restaurant and offices

Air Conditioners Heating & Cooling

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

w w w. d a i k i n. e u ATXS-E

Concealed ceiling units

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Chillers. Technical Data. EWYD-BZ 250~580 kw

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air conditioners Heating & Cooling

Commercial and Technical Data

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Transcription:

Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C

Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C

Indoor Units R-410A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB 1 Features............................................................. 2 2 Specifications....................................................... 3 For indoor units only................................................. 3 Technical Specifications............................................. 3 3 Safety device settings............................................. 5 4 Options.............................................................. 5 5 Dimensional drawing & centre of gravity........................ 7 Dimensional drawing................................................. 7 Centre of gravity.................................................... 10 6 Piping diagram..................................................... 11 7 Wiring diagram..................................................... 12 Wiring diagram...................................................... 12 8 Sound data......................................................... 13 Sound pressure spectrum........................................... 13 Sound power spectrum............................................. 15 9 Fan characteristics................................................ 17 10 Installation.......................................................... 20 Installation method.................................................. 20 Filter installation method............................................ 21 Switch box connection.............................................. 22 Split Sky Air Indoor Units 1

t i y n k r 7t o 0 i o 1- ld 4 np - FI Indoor Units R-410A FBQ-C7VEB 1 Features BU S E V a C Q B RS Reduction in power consumption thanks to DC inverter fans Improved comfort thanks to 3-step airflow control Maximum external static pressure (ESP) is 100Pa Possibility to change ESP through wired remote control allows optimisation of the supply air volume Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Energy efficient: up to class A energy labels Home leave operation saves energy during absence Whisper quiet operation: down to 26 dba sound pressure level Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Easy installation thanks to automatic air flow adjustment towards nominal air flow rate Built-in drain pump as standard increases reliability of the drain system optional standard 3 steps via wired remote control optional 2 Split Sky Air Indoor Units

2 Specifications Indoor Units R-410A FBQ-C7VEB 2-1 For indoor units only FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB Nominal input (Indoor only) Cooling kw 0.14 0.14 0.35 0.35 0.35 0.35 0.35 Heating kw 0.14 0.14 0.35 0.35 0.35 0.35 0.35 2-2 Technical Specifications FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB Casing Colour Non painted Material Galvanised steel Dimensions Packing Height mm 355 355 355 355 355 355 355 Width mm 920 920 1,220 1,220 1,620 1,620 1,620 Depth mm 900 900 900 900 900 900 900 Unit Height mm 300 300 300 300 300 300 300 Width mm 700 700 1,000 1,000 1,400 1,400 1,400 Depth mm 700 700 700 700 700 700 700 Weight Unit kg 25 25 34 34 45 45 45 Packed Unit kg 28 28 41 41 53 53 53 Required Ceiling Void mm >350 Heat Exchanger Dimensions Length mm 440 440 740 740 1,140 1,140 1,140 Nr of Rows 3 3 3 3 3 3 3 Fin Pitch mm 1.75 1.75 1.75 1.75 1.75 1.75 1.75 Nr of Passes 4 4 7 7 11 11 11 Face Area m² 0.148 0.148 0.249 0.249 0.383 0.383 0.383 Nr of Stages 16 16 16 16 16 16 16 Tube type Hi-XSS (7) Fin Type Symmetric waffle louvre Treatment Hydrophilic Fan Type Sirocco fan Quantity 1 1 2 2 3 3 3 Air Flow Rate Cooling High m³/min 16 16 18 18 32 39 39 Low m³/min 11 11 15 15 23 28 28 Heating High m³/min 16 16 18 18 32 39 41 Low m³/min 11 11 15 15 23 28 29 Fan Max High Pa 100 100 100 100 120 120 120 Standard Pa 30 30 30 30 40 50 50 Motor Quantity 1 1 1 1 1 1 1 Model Brushless DC Number of steps 10 10 8 8 9 9 9 Motor Speed (cooling) High rpm 1,186 1,186 942 942 1,060 1,218 1,218 Low rpm 875 875 823 823 813 920 920 Speed (heating) High rpm 1,186 1,186 942 942 1,060 1,218 1,280 Low rpm 875 875 823 823 813 920 967 Fan Motor Output (high) W 140 140 350 350 350 350 350 Drive Direct drive Cooling Sound Power High dba 63 63 57 57 61 66 66 Sound Pressure High dba 37 37 37 37 38 40 40 Low dba 29 29 29 29 32 33 33 Heating Sound Pressure High dba 37 37 37 37 38 40 41 Low dba 29 29 29 29 32 33 34 Refrigerant Type R-410A Piping connections Liquid (OD) Type Flare connection Diameter (OD) mm 6.35 6.35 6.35 9.52 9.52 9.52 9.52 Gas Type Flare connection Diameter (OD) mm 9.52 12.7 12.7 15.9 15.9 15.9 15.9 Drain Diameter (OD) mm VP25 (O.D. 32 / I.D. 25) Heat Insulation Both liquid and gas pipes Drain-up Height mm 625 625 625 625 625 625 625 Split Sky Air Indoor Units 3

2 Specifications Indoor Units R-410A FBQ-C7VEB 2-2 Technical Specifications FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB Decoration Panel Model BYBS45DJW1 BYBS45DJW1 BYBS71DJW1 BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1 Colour White (10Y9/0,5) Dimensions H mm 55 55 55 55 55 55 55 W mm 800 800 1,100 1,100 1,500 1,500 1,500 D mm 500 500 500 500 500 500 500 Weight kg 3.5 3.5 4.5 4.5 6.5 6.5 6.5 Air Filter Resin net with mold resistance Safety Devices PC board fuse PC board fuse (fan driver) Drain pump fuse Notes Nominal cooling capacities are based on : indoor temperature : 27 CDB, 19 CWB, outdoor temperature : 35 CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on : indoor temperature : 20 CDB, outdoor temperature : 7 CDB, 6 CWB, equivalent refrigerant piping : 7.5m, level difference : 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction Remote Control Wired BRC1D528 4 Split Sky Air Indoor Units

Indoor Units R-410A FBQ-C7VEB 3 Safety device settings FBQ Safety devices 35 50 60 71 100 125 140 PC Board Fuse 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A PC Board Fuse (Fan Driver) 250V 5A 250V 5A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A Fan Motor Thermal Protector C Drain Pump Fuse C 145 145 145 145 145 145 145 4 Options FBQ35-140C Options Item FBQ35,50 FBQ60,71 FBQ100,125,140 Panel related Decoration panel (*4) BYBS45D BYBS71D BYBS125D Air inlet and air discharge outlet related Air discharge adapter for round duct KDAJ25K56A KDAJ25K71A KDAJ25K140A Panel related Decoration panel option EKBYBSD Operation Control Item FBQ35,50 FBQ60,71 FBQ100,125,140 Remote Control Wired Type BRC1D528 / BRC1E51A Wireless Type HP BRC4C65 CO BRC4C66 Option BCB for external el. heater, humidifier and/or hour meter (*1), (*3) EKRP1B2A Adapter for wiring (interlock for fresh air intake fan) (*3) KRP1C64 Wiring adapter for electrical appendices (*3) KRP4A51 Remote sensor KRCS01-4B Central remote control DCS302CA51 Unified ON/OFF controller DCS301BA51 Schedule timer DST301BA51 Remote ON/OFF and FORCED OFF kit EKRORO3 Mounting plate for adapter PCB KRP4A96 (*1): Electrical heater and humidifier are field supply. These parts should not be installed inside the equipment (refer to installation manual EKRP1B2A) (*2): If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for each indoor unit is required. (*3): Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB s can be mounted. (*4): Decoration panel option EKBYBSD is required for direct mounting of the decoration panel on the unit. Contents of accessory bag Description Quantity FBQ35,50,60,71,100,125,140 Hexagon tapping screw (M5x16) 16 Round plain washer for wood 8 Installation and operation manual 1 Hose band 1 Insulation for joint (GAS) 1 Insulation for joint (LIQUID) 1 Drain hose 1 Drain hose sealing material 1 Sealing material 2 3TW31279-3D Split Sky Air Indoor Units 5

Indoor Units R-410A FBQ-C7VEB 4 Options EKRORO3 Wire specifications Operating method On Terminal X2M Screw to control box replacing the original terminal Connector (White) connect to indoor PCB (X30A) unit INPUT T1,T2Switch Off Remote controller Standard setting: forced off Alternative setting: on/off On Off On Off On Off Input ON = closed contact. Forced off Input on stops operation + disables control Input off enables control On/off operation Input off on: starts operation, remote control is still enabled. Input on off: stops operation, remote control is still enabled. Selection of FORCED OFF and ON/OFF operation Setting Mode No. First code NO Second code NO Forced off 01 12 (22) 1 On/off operation 02 3TW31601-1 6 Split Sky Air Indoor Units

Indoor Units R-410A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing FBQ35C View A-A Detail B 1 Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing (Knock out hole) Fresh air intake position suspension bolt 75 or more (service space) (On circumference) 500 or more (service space) Detail B (Suspension position) 631 (suspension position) Item Name Description 1 Liquid pipe connection Ø6.35 flare connection 2 Gas pipe connection Ø9.52 flare connection 3 Drain pipe connection VP25 (OD Ø32, ID Ø25) 4 Remote control wiring connection - 5 Power supply connection - 6 Drain hole VP25 (OD Ø32, ID Ø25) 7 Air filter - 8 Air suction side - 9 Air discharge side - 10 Nameplate - 3TW31274-1A FBQ50C View A-A Detail B Nr Name Description 1 Liquid pipe connection ø 6.35 flare (connection) 2 Gas pipe connection ø 12.70 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 10 Nameplate Suspension bolt (Knock out hole) Fresh air intake position 350 or more (Service space) (On circumference) or more (Service space) Detail B (Suspension position) (Suspension position) NOTE 1 Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW31214-1A Split Sky Air Indoor Units 7

Indoor Units R-410A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing FBQ60C View A-A Detail B Suspension bolt 350 or more (Service space) or more (Service space) Detail B (Suspension position) (Suspension position) Nr Name Description 1 Liquid pipe connection ø 6.35 flare (connection) 2 Gas pipe connection ø 12.70 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 10 Nameplate NOTE 1 Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW31294-1 FBQ71C View A-A Detail B Nr Name Description 1 Liquid pipe connection ø 9.52 flare (connection) 2 Gas pipe connection ø 15.90 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 10 Nameplate (Knock out hole) Fresh air intake position Suspension bolt (On circumference) 350 or more (Service space) or more (Service space) Detail B (Suspension position) (Suspension position) NOTE 1 Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW31234-1A 8 Split Sky Air Indoor Units

Indoor Units R-410A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing FBQ100-140C View A-A Detail B Nr Name Description 1 Liquid pipe connection ø 9.52 flare (connection) 2 Gas pipe connection ø 15.90 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 10 Nameplate (Knock out hole) Fresh air intake position Suspension bolt 350 or more (Service space) (On circumference) 500 or more (Service space) Detail B (Suspension position) 631 (Suspension position) NOTE 1 Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW31254-1A Split Sky Air Indoor Units 9

Indoor Units R-410A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-2 Centre of gravity FBQ35-140C Model A B FBQ35,50 283 700 FBQ60,71 441 1000 FBQ100~140 619 1400 4TW31189-1B 10 Split Sky Air Indoor Units

Indoor Units R-410A FBQ-C7VEB 6 Piping diagram FBQ35-140C Heat exchanger Refrigerant flow Cooling Heating Refrigerant pipe connection port diameters Model Gas Liquid FBQ35C 9.52 6.35 FBQ50C 12.70 6.35 FBQ60C 12.70 6.35 FBQ71C 15.90 9.52 FBQ100C 15.90 9.52 FBQ125C 15.90 9.52 FBQ140C 15.90 9.52 Liquid pipe connection port Gas pipe connection port 3TW31275-1 Split Sky Air Indoor Units 11

7 Wiring diagram 7-1 Wiring diagram FBQ35-50C7VEB 1N~220-240V 50Hz 1N~220V 60Hz Indoor Units R-410A FBQ-C7VEB BLU : Blue wired remote control BRN : Brown (optional accessory) GRY : Gray Common ORG : Orange power supply PNK : Pink note 4 RED : Red WHT : White YLW : Yellow GRN : Green Switch box (indoor) Indoor unit M1F Motor (fan) SS1 Selector switch (emergency) TC Signal transmission circuit A1P Printed circuit board M1P Motor (drain pump) S1L Float switch Connector optional accessory A2P Printed circuit board (fan) PS Switching power supply V1R Diode bridge X28A Connector (Power supply for wiring) C1 Capacitor Q1DI Earth leak detector V2R Power module X33A Connector (for wiring) F1U, F2U Fuse (T, 5A, 250V) R1 Resistor (current limiting) X1M Terminal strip (power supply) X35A Connector (adapter) F4U Fuse (T, 6.3A, 250V) R2 Current sensing device X2M Terminal strip (control) X85A Connector (for multi zoning) HAP Light emitting diode (Service monitor green) R1T Thermistor (suction air) Z1C Noise filter (ferrite core) X33A Connector (for wiring) KPR, K1R Magnetic relay R2T Thermistor (liquid) Z1F Noise filter Wired remote control L1R Reactor R3T Thermistor (gas) RC Signal receiver circuit SS1 Selector switch (emergency) 1 Use copper conductors only. 2 When using the central remote controller, see manual for connection to the unit. 3 The remote control model varies according to the combination system. See technical materials and catalogues, etc. before connecting. 4 Refer to installation manual. indoor norm.emg Transmission wiring central remote control note 2, L N : Field wiring : Live : Neutral : Connector : Wire clamp : Protective earth (screw) Colors BLK : Black 2TW31276-1A FBQ60-140C7VEB 1N~220-240V 50Hz 1N~220V 60Hz BLU : Blue Wired remote control BRN : Brown (optional accessory) GRY : Gray Common ORG : Orange power supply PNK : Pink note 4 RED : Red WHT : White YLW : Yellow GRN : Green Switch box (indoor) Indoor unit L1R Reactor R3T Thermistor (gas) TC Terminal strip (control) A1P Printed circuit board M1F Motor (fan) R5T Thermistor NTC (Current limiting) Y1E Electronic expansion valve A2P Printed circuit board (fan) M1P Motor (drain pump) SS1 Selector switch (emergency) Connector optional accessory A3P Printed circuit board (capacitor) PS Switching power supply S1L Float switch X33A Connector (for wiring) C1, C2, C3 Capacitor Q1DI Earth leak detector V1R Diode bridge X35A Connector (adapter) F1U Fuse (T, 5A, 250V) R2 Current sensing device V2R Power module X38A Connector (for wiring) F3U Fuse (T, 6.3A, 250V) R3, R4 Resistor (electric discharge) Z1C Noise filter (ferrite core) Wired remote control HAP Light emitting diode (service monitor green) R1T Thermistor (suction air) Z1F Noise filter R1T Thermistor (air) KPR, K1R Magnetic relay R2T Thermistor (liquid) RC Terminal strip (power supply) SS1 Selector switch (main/sub) only for 60 class Transmission wiring central remote control note 2 1 Use copper conductors only. 2 When using the central remote controller, see manual for connection to the unit. 3 The remote control model varies according to the combination system. See technical materials and catalogues, etc. before connecting. 4 Refer to installation manual. only for 60 class NORM. EMG, L N : Field wiring : Live : Neutral : Connector : Wire clamp : Protective earth (screw) Colors BLK : Black 2TW31296-1A 12 Split Sky Air Indoor Units

8 Sound data 8-1 Sound pressure spectrum Indoor Units R-410A FBQ-C7VEB FBQ35-50C FBQ60C Sound pressure level [db] Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW31217-2 High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW31297-2 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba= A-weighted sound pressure level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphone Suction Unit Discharge 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba= A-weighted sound pressure level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphone Suction Unit Discharge Microphone Microphone FBQ71C FBQ100C Sound pressure level [db] Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW31297-2 3TW31257-2 Notes 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction 1.5m Unit Discharge 2m 2m 1.5m Microphone 1m Notes 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction Unit Discharge 2m 2m 1.5m Microphone 1m 1.5m Split Sky Air Indoor Units 13

8 Sound data Indoor Units R-410A FBQ-C7VEB 8-1 Sound pressure spectrum FBQ125C FBQ140C Sound pressure level [db] Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW31267-2 3TW31337-2 Notes 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction 1.5m Unit Discharge 2m 2m 1.5m Microphone 1m Notes 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction Unit Discharge 2m 2m 1.5m Microphone 1m 1.5m 14 Split Sky Air Indoor Units

Indoor Units R-410A FBQ-C7VEB 8 Sound data 8-2 Sound power spectrum FBQ35-50C FBQ60C Sound power level [db] Sound power level [db] High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW31217-1 High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW31297-1 1 dba= A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6μW/m 2 3 Measured according to ISO 3744 1 dba= A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6μW/m 2 3 Measured according to ISO 3744 FBQ71C FBQ100C Sound pressure level [db] Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW31297-1 3TW31257-1 Notes 1 dba = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6μW/m 2 3 Measured according to ISO 3744 Notes 1 dba = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6μW/m 2 3 Measured according to ISO 3744 Split Sky Air Indoor Units 15

Indoor Units R-410A FBQ-C7VEB 8 Sound data 8-2 Sound power spectrum FBQ125-140C Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW31267-1 Notes 1 dba = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6μW/m 2 3 Measured according to ISO 3744 16 Split Sky Air Indoor Units

9 Fan characteristics Indoor Units R-410A FBQ-C7VEB FBQ35-50C Fan characteristics (1) Fan characteristics (3) (airflow auto adjustment) Upper limint of ESP (std ESP ) Upper limint of ESP (max ESP ) L (max ESP) L (std ESP) M (max ESP) M (std ESP) H (max ESP) H (std ESP) (std ESP) (max ESP) Upper limint of ESP L Upper limint of ESP by airflow auto adjustment M Upper limint of ESP by airflow auto adjustment H Airflow [m 3 /min] Airflow [m 3 /min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m 3 /min] 1 Fan characteristics as shown are in fan only mode. 2 ESP: External static pressure 3TW31218-1 FBQ60C Fan characteristics (1) Fan characteristics (3) (airflow auto adjustment) Upper limint of ESP (max ESP ) L (max ESP) Upper limint of ESP (std ESP ) M (max ESP) M (std ESP) H (max ESP) H (std ESP) (max ESP) Upper limint of ESP L Upper limint of ESP by airflow auto adjustment M Upper limint of ESP by airflow auto adjustment H L (std ESP) (std ESP) Airflow [m 3 /min] Airflow [m 3 /min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m 3 /min] 1 Fan characteristics as shown are in fan only mode. 2 ESP: External static pressure 3TW31298-1 Split Sky Air Indoor Units 17

9 Fan characteristics Indoor Units R-410A FBQ-C7VEB FBQ71C Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) Upper limit of ESP (max. ESP) L (max. ESP) Upper limit of ESP (std. ESP) M (max. ESP) M (std ESP) H (max. ESP) H (std ESP) (max. ESP) Upper limit of ESP L Upper limit of ESP by airflow auto adjustment M by airflow auto adjustment H L (std ESP) (std. ESP) Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m³/min] 1 Fan characteristics as shown ar in fan only mode. 2 ESP: External static pressure 3TW31298-1 FBQ100C Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) L (max. ESP) Upper limit of ESP (std. ESP) L (std ESP) Upper limit of ESP (max. ESP) M (max. ESP) M (std ESP) H (max. ESP) H (std ESP) (max. ESP) (std. ESP) Upper limit of ESP L M Upper limit of ESP by airflow auto adjustment by airflow auto adjustment H Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m³/min] 1 Fan characteristics as shown ar in fan only mode. 2 ESP: External static pressure 3TW31258-1 18 Split Sky Air Indoor Units

9 Fan characteristics Indoor Units R-410A FBQ-C7VEB FBQ125C Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) Upper limit of ESP (std. ESP) L (max. ESP) Upper limit of ESP (max. ESP) L (std ESP) M (max. ESP) M (std ESP) H (max. ESP) H (std ESP) (std. ESP) (max. ESP) Upper limit of ESP L Upper limit of ESP by airflow auto adjustment M by airflow auto adjustment H Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m³/min] 1 Fan characteristics as shown ar in fan only mode. 2 ESP: External static pressure 3TW31268-1 FBQ140C Fan characteristics (1) Fan characteristics (3) (airflow auto adjustment) Upper limint of ESP (std ESP ) Upper limint of ESP (max ESP ) L (max ESP) L (std ESP) M (max ESP) M (std ESP) H (max ESP) H (std ESP) (std ESP) (max ESP) Upper limint of ESP L Upper limint of ESP by airflow auto adjustment M Upper limint of ESP by airflow auto adjustment H Airflow [m 3 /min] Airflow [m 3 /min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m 3 /min] 1 Fan characteristics as shown are in fan only mode. 2 ESP: External static pressure 3TW31268-1 Split Sky Air Indoor Units 19

10 Installation 10-1 Installation method FBQ35-140C Indoor Units R-410A FBQ-C7VEB Rear Suction Bottom Suction Ceiling return Ceiling return Drain pump up height Installation with duct Direct installation of inlet panel EKBYBSD is required for direct installation Wide variety of installation methods Number Description 1 Main body 2 Air outlet duct Field supply 3 Inlet panel Optional accessory 4 Acces panel optional accessory 5 Air inlet duct Field supply Easy modification from rear to bottom suction 3TW31183-1A 20 Split Sky Air Indoor Units

10 Installation 10-2 Filter installation method FBQ35-140C Indoor Units R-410A FBQ-C7VEB (or less) Installation without air inlet duct Installation with air inlet duct Nr. Description 1 When installing the unit with rear 1 Suspended Ceiling suction, a service opening is 2 Ceiling opening necessary for the maintenance of 3 Service access panel (optimal) the air filters. 4 Air filter 2 When installing the unit with a 5 Air inlet duct 6 Duct service opening suction duct. A service opening must be provided in the duct. 3TW31184-4 Split Sky Air Indoor Units 21

10 Installation 10-3 Switch box connection Indoor Units R-410A FBQ-C7VEB FXSQ35-140C Emerg. Norm. Common power supply FBQ 3TW31184-5A 22 Split Sky Air Indoor Units

Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN10-100 04/10 Copyright Daikin The present publication supersedes EEDEN09-100 Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environment is set in the EMAS and ISO 14001 systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende