Anti-sweat Energy Saver Installation guide

Similar documents
MT-374B/364B Operation User s Guide. The Anti-Sweat Energy Saving Controller user s manual

Refrigerant Leak Detector Manual

Ammonia Leak Detector Manual

MT Alliance Refrigeration Technician s Manual

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

Dryer Controller M720

Data Aire DAP TM III. LonWorks Protocol Integration Information

User Manual. Dryer Controller M720

Data Aire DAP TM III. LonWorks Protocol Integration Information

AxxonSoft. Operation Manual TROMBONE. Fire and Security Alarm Integration Module. Version 1.1. Moscow

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

Remote NAC Power Supply D7038

I/O ZONE 560/583 AND OPERATION MANUAL

Refrigerated air dryers

DESCRIPTION NOTE. Temperature and Humidity Sensors MODEL 1260B

RangerNET Network Ready Constant Monitor Model CM2815

Added password for IP setup page : Password must be in IP format!

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

OVEN INDUSTRIES, INC.

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Tachometer/Hourmeter/Trip. Installation and Operation Manual

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Roth Touchline. German quality since Quick and easy user manual 1/10

Configuration and Operation Manual for the Unipos

ACTIVE INFRARED BARRIER

DESCRIPTION MODEL 1205/1205HA NOTE

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

East Central College

Remote Sensor Module: EB-RSM-01

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Substation Monitoring System

EasyTronic III MANUAL SERVICE

C-Bus Four Channel Analogue Output Unit Installation Instructions

Interfacing with the ADAM Module

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

General The Dryer Programmer for Windows Computers

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Operation & Maintenance Manual

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

RCS Residential Control Systems Inc.

Model 4880 Status Output Display Module Manual

Flostop TS D7E and A8E. Operation Manual

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

ProStar 325 UV-Vis Detector

2012 Toolbar & NH3 Operators Manual

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Flopurge TS. Operation Manual

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Dry Contact Probe DCP (#30008)

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

Manage Alarms. Before You Begin CHAPTER

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Monitoring Software for NPBC-V3M-1 User Manual

EBDSPIR-PRM-LV Product Guide

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features


Concord 5 TouchScreen Installation Sheet

Application Guide. CCU2 Chiller Controller. Self-Contained Interoperable Controller Model UCP-1 for Software Version 2.

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

METEOROLOGICAL INSTRUMENTS

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

OPERATING MANUAL Enertronic Control System 2

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Network Hardware and wiring (quiz)...

P/N f. HomeWorks QS Palladiom Thermostat Configuration Guide

MODEL DZSP/ SZSP-1440 AIRCELL

VH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, R7)

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

LMS-188-4P 4 POINT DIGITAL MONITOR/ALARM OPERATING INSTRUCTIONS

Planning Elevator Relay Groups Programming Millenium for Windows Software

OPERATING MANUAL Enertronic Control System 2

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Wireless High Voltage Digital Thermostat

Danfoss gas detection unit Type GD Heavy Duty

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

1.0 Digital Controller

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

NT DUAL CHANNEL DISPLAY. User Guide

Installation, Operating and Maintenance Manual

2704 Controller Melt Pressure Controller

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Transcription:

MTA installation and operation Parker Hannifin Canada Micro Thermo Technologies TM 12855 Brault Street Mirabel, QC J7J 0C4 Office phone 450-668-3033 Introduction. Anti-sweat Energy Saver Installation guide The Anti-sweat Energy Saver model MT-374B is an MT-Alliance compatible controller that modulates the power delivered to a maximum of 4 anti-sweat heaters channels according to the dew point in the supermarket where the controller is installed. Temperature and humidity measurement are used to calculate how much heating it is required to avoid condensing on glass doors. The processor board work without local user interface when networked with an MT-Alliance computer but it can work as standalone with the Local User Interface MT-364B ordered separately. Wiring: 4 Outputs: 24Vdc pulsed 100mA Maximum Limited DATA A B C D DATA MT-3744 MT-374B HTR1+ HTR1- HTR2+ HTR2- HTR3+ HTR3- HTR4+ HTR4- Relay group 1 RELAIS 1 DU SWEATMISER Relay group 2 RELAIS 2 DU SWEATMISER Relay group 3 RELAIS 3 DU SWEATMISER Relay group 4 RELAIS 4 DU SWEATMISER + - THERM + - HUM GND 24Vdc SENSORS MANUAL BYPASS % SAVING %SAVING ALARM OUT E 24Vac 24Vac 0-5V Dry contact N/O POWER 24 Vac 1 Physical Installation: The Anti-sweat Energy Saving board comes on a snaptrack. Remove the board from the snaptrack and secure the snaptrack on a solid surface inside of an electric panel using screws. Put back the Anti-sweat Energy Saving board by clipping it on the snaptrack. Make all wiring connection accordingly to the diagram connection above or on a drawing provided from Parker Hannifin Engineering advisor. Use a Micro Thermo Temperature and Humidity combo sensor p/n 023-0026. A connection to earth ground must be made for proper 24VAC power filtering, and provide EMC and ESD protection for the FTT-10A transceiver. 2 MT-Alliance Installation: The MT-374B can be installed on MTA 7.2.3 or later but it is possible to install it on version 6.0 or later on certain conditions. Before installation in version 6.0 you must install the patch for MT-374B. If you are replacing a 3744 with a 374B on MTA before 7.2.3 you will need to install the patch before executing the replacement. From the moment the node is dropped and installed on a view, Dew Point Alarm is monitored by MTA, the optional Local User Interface will display measurements but controls will be locked. See also the Anti-sweat standalone User Manual PUID 75-PHW-1012 for standalone installation and configuration with the Local User Interface. 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 1 de 9

3 Alliance Configurations Step by step procedure In MT Alliance 7.3 you should create a view with the Configure - Views menu Select the Refrigeration subsystem then click Add, then Change Image, then select Anti-Sweat.bmp Then change the View identification for Anti-Sweat Example with Anti-Sweat.bmp If you have 2 Anti-Sweat controller you can use Anti-Sweat Dual.bmp If for any reason you may want blank point location you may change images for Anti-Sweat no nv.bmp or Anti-Sweat Dual no nv.bmp 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 2 de 9

Dropping the Node and Custom Points Place the point so nv info get hidden Drop a Custom Node on the Anti-Sweat view: Node type: - Custom Manufacturer: - Micro Thermo Model: - Gen Anti-sweat V7.0 First, you can drop an Electric Equipment to avoid to show a blank space in Overview mode Click Details tab of the node and enter Identification: AS3 Click Commands/Status and install it to get the node ready for configuration. Drop a custom point for Bypass Command: Point Type: - Command Physical Type: - Switch Identification: Leave default Custom node identification: AS3 Network Variable Input Name: nvibypassmode Off/On Description: Normal - Bypass Button color Off: Grey Off Glyph: Button color On: Green On Glyph: Drop a custom point for Output Status: Point Type: - Measure Physical Type: - Switch Identification: Leave default Custom node identification: AS3 Network Variable Input Name: nvibypassmode Off/On Description: Normal - Bypass Button color Off: Grey Off Glyph: Button color On: Green On Glyph: 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 3 de 9

Drop a custom point for Store Temperature: Point Type: - Mesure Physical Type: - Temperature Network Variable Output Name: nvotemperature Drop a custom point for Store Humidity: Point Type: - Measure Physical Type: - Humidity On the hardware tab: Network Variable Output Name: nvohumidity Drop a custom point for calculated Dew Point: Point Type: - Mesure Physical Type: - Temperature Network Variable Output Name: nvodewpt Drop a custom point for calculated Savings: Point Type: - Measure Physical Type: - Percent Network Variable Output Name: nvosmsaving Drop a custom point for Output Power: Point Type: - Measure Physical Type: - Percent Network Variable Output Name: nvosmstatus To use remote sensors you need to make these network connections from the Network menu: nvorh A\C-X -----------------------> Anti-sweat (AS3). nvihumidity nvotemp A\C-X ----------------------> Anti-sweat (AS3). nvitemperature If an nvi sensor is not bound the respective local sensor will be used automatically. If for any reason you may want blank point location you may change images for Anti-Sweat no nv.bmp or Anti- Sweat Dual no nv.bmp 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 4 de 9

4 Alarm Management From the moment the Anti-sweat Energy Saving node is dropped and installed on a view, Dew Point Alarm is monitored by MT Alliance and eventually appears on the Alarm panel. To change Dew Point alarm High Limit and Set Time you need to open the Anti_Sweat_Ctrl LonMark Objects in the Node Information window. Dew Point alarm High Limit is defined with UCPTDewPtAlarmSt1 with 0 2:0:0:0 as default value for 0 days, 2 hours, 0 minutes and 0 second. Dew Point Set Time is defined with UCPTDewPtHighLim1 with 25 C as default value. To change any of the CP, double click on it and change the appropriate value. Take special care to change Set Time as the structure is not explicitly shown: Days Mins Sec/10 Hours Secs Temperature and dew point values are available in Celsius only Click OK then Yes to Accept Changes and to program CPs when prompted 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 5 de 9

It is also possible to monitor nvosmsaving through an alarm config of a sensor of a Sensor Node. By example if you want an alarm in case of there is no saving for more than 24 continuous hours Set Low Limit to 1% and set time to 24h. 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 6 de 9

5 Transfer Function Parameter Setting. The transfer function of the control is based on two points (StPtMin, StPtMax) each one identified by two coordinates on a DEW/PWR graphic: StPtMin (DpMin, PwMin) and StPtMax (DpMax, PwMax) used to modulate the output power according to the dew point. Output chanel timing diagram 100 % PwMax (95%) Full Power StPtMax % Power (Default) 0 % PwMin (20%) -18 C DpMin (-1) StPtMin DpMax (13) Dew Point (Default) DPHL (25) 37 C If Dew Point < Dew1 then %Power = Pwr1, If Dew Point > Dew2 then % Power = Pwr2 If Dew1 Dew Point Dew2 then Pwr1 %Power Pwr2 If Dew Point > Alarm Dew Point High Limit then %Power = FP (FP = Full Power = 100%) 6 Operation Unless bypass is ON, at power up the UCPTSmOnDelay will prevent heating for 60 sec. When running it will pulse each heater channel sequentially with a duty cycle according to the % power. If dew point is higher than Dew Point High Limit (UCPTDewPtHighLim1) for longer than Dew Point Set Time (UCPTDewPtAlarmSt1) the output power will be forced to Full Power, Dew Point Alarm will appear on the Alarm Panel and the board normally open dry contact will remain close as long as the alarm status is ON. If thereafter the dew point becomes lower than the limit, the Alarm Status will remain but the output power for heating will not be forced to full any more. This alarm function can be used to detect persistent moisture problem. It is also possible to perform a manual bypass to force the Anti-sweat Energy Saver to run at Full Power until the bypass is released. Manual Bypass can be performed locally on the board or by the command point on the Anti-Sweat view either in Overview mode or Configuration mode If the temperature or the humidity value comes from the network via a SNVT and the communication fails, the reading will switch to a local sensor. If no remote sensor and no local sensor temperature or humidity is found the temperature sensor display and the dew point display will show "327.7C", the humidity sensor will show "163.8%", the system will put the Outputs to a full power 100% duty cycle and the Output Power will show "100%" and the %Saving will be 0%. You will get the alarm status after the Dew Point Set Time expires. Calibration can be done to the sensors using UCPTTempOffset and UCPTHumOffset. 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 7 de 9

Annex A LonMark Objects 72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 8 de 9

72-MTA-1037-R3.0 MTA 7.3 Anti-Sweat Installation Guide.docx RL 16-09-27 Page 9 de 9