Home Inspection Report

Similar documents
Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Home Inspection Report

Home Inspection Report

American Property Inspectors of Northwest Florida, Inc.

Home Inspection Report

Home Inspection Report

Property Condition Report

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

All Around Home Inspections Ltd 1346 Hurford Ave Courtenay, BC. 123 Sample 6 Plex

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Jeff Brown Inspections

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Canadian Property Inspections

Inspection Report 123 My Street Midland, GA

Attention To Detail Home Inspections, LLC Marchester Dr. Wesley Chapel, FL Report prepared by: Steven Milek Certified NACHI Inspector

Axiom Property Inspections

Extra Mile Inspection, Inc.

Inside Out Home Inspections

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

Inspector FX Field Forms

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

Excellent Home Inspection Services, LLC

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Watson Home Inspection Services, LLC.

Bayshore House Inspections LLC

I. STRUCTURAL SYSTEMS

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Inspector Gadget Homes

Canadian Property Inspections

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

fieldwork report contains the Functional

Troy's Home Inspection Services LLC

Peconic Home Inspections, LLC Inspection Report. 123 Lane Suffolk, New York 11900

McKinney Inspection Company

Doyle Home Inspections

This Report Was Prepared For: Property Address Inspected:

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

Hope Home Inspections LLC rd Ln E Sarasota, FL

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

RW West Consultants. Property Inspection Report

Home Inspection Report

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

All In One Home Inspections

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

Maintence/Renewal Report

Tennessee Valley Property Inspections

52245 E 144th Ave. Prepared for Ed & Jane Allard Prepared by Ryan Goeglein Equity Home Inspections

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

Steve Ramsey Home Inspections

Cascade Inspection Services, LLC

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

CMHC HOME MAINTENANCE CHECKLIST

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

National Property Inspections

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

Inspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc.

Hearth and Homes Inspections, llc

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

MHI Services Inc. Property Inspection Report

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

Space Coast Home Inspections LLC

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

SPS Home Inspections, LLC

Residential Construction and Remodeling Estimates. compliments of. pillartopost.com

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

Patriot Home Inspections

Examples of Acclaim s Energy-Efficiency Green Technology

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

Residential * Commercial * Mobile Homes * New Construction

FAIRA TRANSPARENCY REPORTS nd Ave SE, Renton, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

Property Inspection Report

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

Home Inspection Report

The Ultimate Home Maintenance Schedule

C omplete H ome I nspections

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

Inspection Report. Property Address: XXXX Sondrio Dr Las Vegas NV Skye Canyon Home Inspection Services

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

Transcription:

21351 Village Green Circle Germantown, MD 20876 Inspector Pete Jung ph 301 351-1113 fax 301 542-0100 Home Inspection Report 1234 Any Street Pleasantville, MD or VA 54321

15:18 October 10, 2009 Page 1 of 17 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior Surface and Components 3 Roof 4 Garage/Carport 5 Electrical 5 Structure 6 Attic 6 Basement 7 Air Conditioning 7 Fireplace/Wood Stove 8 Heating System 8 Plumbing 9 Bathroom 9 Kitchen 12 Laundry Room/Area 13 Summary 14

15:18 October 10, 2009 Page 2 of 17 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection A Acceptable Functional with no obvious signs of defect. NP Not Present Item not present or not found. NI Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. M Marginal Item is not fully functional and requires repair or servicing. D Defective Item needs immediate repair or replacement. It is unable to perform its intended function. Property Address 1234 Any Street City Pleasantville State MD or VA Zip Contact Name Excellent Realtor Phone Fax Client Name Mr. & Mrs. Client Client Address City State Zip Phone Fax E-Mail nicepeople@hotmail.com Inspector Name Pete Jung Company Name Hinson & Jung, LLC Company Address 21351 Village Green Circle City Germantown State MD Zip 20876 Phone 301 351-1113 Fax E-Mail petejung1@msn.com File Number 1234 sample Amount Received Check or credit card General Information Property Information Client Information Inspection Company Conditions Others Present Buyer's Agent Property Occupied Yes Estimated Age 28 years old Entrance Faces South south east Inspection Date Start Time 9:00 am End Time 12:30 pm Electric On Yes No Not Applicable Gas/Oil On Yes No Not Applicable Water On Yes No Not Applicable Temperature 60F Weather Cloudy Soil Conditions Damp Space Below Grade Basement Building Type Single family Garage Attached Sewage Disposal City How Verified Visual observation Water Source City How Verified Visual observation Additions/Modifications Possibly the deck Permits Obtained Unknown How Verified N/A

15:18 October 10, 2009 Page 3 of 17 Lots and Grounds Report Limitations- This report is intended only as a general guide to help the client make his/her own evaluation of the overall condition of the home, and is not intended to reflect the value of the premises, nor make any representation as to the advisability of purchase. The report expresses the personal opinions of the inspector, based upon his visual impressions of the conditions that existed at the time of the inspection only. The inspection and report are not intended to be technically exhaustive, or to imply that every component was inspected, or that every possible defect was discovered. No disassembly or equipment, opening of walls, moving of furniture, appliances or stored items, or excavation was performed. All components and conditions which by the nature of their location are concealed, camouflaged or difficult to inspect are excluded from the report. 1. Walks: Concrete 2. Steps/Stoops: Concrete 3. Deck: Stained wood Unless the deck was part of the original construction, evidence of its having been inspected by the County is needed 4. Vegetation: Shrubs and plants Shrubs too close to the cladding; recommend it be trimmed back at least 6". Keep mulch and all growth at least 6 inches away from the foundation wall. 5. Grading: Minor slope to flat It is important that the slope is sufficient to ensure that water does not pool against the foundation wall. 6. Driveway: Asphalt Common cracks Exterior Surface and Components Whole house Exterior Surface 1. Type: Brick and wood Wood siding needs to be checked thoroughly to ensure that there is no wood rot. There are several areas near the brick chimney, left side of the house that need attention. Recommend a licensed contractor to make necessary repairs. 2. Trim: Wood Trim near the left side of the garage has peeling paint. Check for wood rot and replace if necessary. Scraping and painting advised. 3. Fascia: Wood 4. Soffits: Aluminum and wood 5. Door Bell: Hard wired

15:18 October 10, 2009 Page 4 of 17 Exterior Surface and Components (Continued) 6. Entry Doors: Wood 7. Patio Door: Sliding glass doors Screen has several holes in it. Recommend it be replaced. 8. Windows: Single pane wood frame with storm window Several windows are painted shut. They all need to be operable. 9. Window Screens: Functional 10. Basement Windows: Aluminum slider 11. Exterior Lighting: Surface mount 12. Exterior Electric Outlets: 110 VAC GFCI 13. Hose Bibs: Appears serviceable. 14. Gas Meter: Right side of house Roof Main Roof Surface 1. Method of Inspection: Viewed from the ground with binoculars (these inspections are limited)* 2. Material: Asphalt/Composite Shingle 3. Type: Gable 4. Approx Age: 6 years old (per owner) 5. Plumbing Vents: PVC DWV 6. Gutters: Adequate 7. Downspouts: Adequate except as noted Several downspouts have been squashed so they almost shut. They should be straightened or replaced. 8. Leader/Extension: Splash blocks Relocate splash blocks to make them effective, many are not under the downspouts. Left Chimney 9. Chimney: Brick 10. Flue/Flue Cap: Tile 11. Chimney Flashing: Adequate Rear Chimney 12. Chimney: Metal pipe 13. Flue/Flue Cap: Metal 14. Chimney Flashing: Adequate

15:18 October 10, 2009 Page 5 of 17 Garage/Carport Front entry Garage 1. Type of Structure: Attached Car Spaces: 2 2. Garage Doors: Functional 3. Door Operation: Mechanized 4. Door Opener: Automatic reverse operated 5. Service Doors: Fire rated 6. Ceiling: Dry wall 7. Walls: Dry wall 8. Floor/Foundation: Poured slab 9. Electrical: GFCI Electrical 1. Service Size Amps: 200 Volts: 220-240 VAC 2. Service: Aluminum Underground 3. 120 VAC Branch Circuits: Copper 4. 240 VAC Branch Circuits: Copper 5. Conductor Type: Non-metallic sheathed cable 6. Smoke Detectors: Present on all levels of the home NFPA recommends replacing if over 10 years old, Recommend adding a carbon monoxide detector. Hard wire with a battery back up. The best location (if only 1 detector) is in the hall way outside the sleeping rooms. Basement Electric Panel 7. Manufacturer: Gould Hot(live) wire open inside the panel. Recommend corrective action by a licensed electrician. 8. Max Capacity: 200 Amps 9. Main Breaker Size: 200 Amps 10. Breakers: CU Several breakers not labeled correctly at the panel. Many just say 'lights'. 11. Is the panel bonded? Yes No Basement Electric Panel 12. Manufacturer: Cutler-Hammer 13. Breakers: CU 14. Is the panel bonded? Yes No

15:18 October 10, 2009 Page 6 of 17 Structure Areas hidden from view by finished walls or stored items can not be judged and are not a part of this inspection. Minor cracks are typical in many foundations and most do not represent a structural problem. If major cracks are present along with bowing, we routinely recommend further evaluation by a qualified structural engineer. All exterior grades should allow for surface and roof water to flow away from the foundation. All concrete floor slabs experience some degree of cracking due to shrinkage in the drying process. In most instances floor coverings and stored items prevent recognition of cracks or settlement in all but the most severe cases. Where carpeting and other floor coverings are installed, the materials and condition of the flooring underneath cannot be determined. Most basements are not completely water proof. Indications of dampness can be difficult to detect during the inspection especially when there has not been any significant rain prior to the inspection. Even if the basement is perfectly clean and dry at the time of the inspection, basements should be regarded as likely sources of water entry around the foundation or through the floor. Check with the present owners as to any past or present water or dampness in the basement or crawl space. Any areas of staining or discoloration which based on other factors such as evidence of moisture intrusion in the general area, could be a possible fungal/mold/mildew contamination and should be reviewed by a qualified professional trained to work with this environmental concern. 1. Structure Type: Wood frame 2. Foundation: Poured concrete 3. Joists/Trusses: Joists Mostly not visible 4. Floor/Slab: Poured slab Mostly not visible Attic Main Attic 1. Method of Inspection: Entered attic 2. Roof Framing: 2x4 Truss 3. Sheathing: Plywood 4. Ventilation: Gable and soffit vents Evidence of a mold like substance on several of the 2X4's of the truss system. I do recommend that it be remediated. This is also an indication that there is not adequate ventilation in this attic. It is important that the attic fan is working when the attic temperature reaches 110F. 5. Insulation: Batts of fiberglass 6. Insulation Depth: 0" to 6" Recommend additional insulation be installed; total of 12" needed. There should be as much insulation over the top of the attic stairs as found elsewhere in the attic. Sometimes a light wood frame is built with hinges on one side. Insulation is fastened to the top and it is pushed to the side when entering the attic. 7. Attic Fan: Thermostatically controlled Unable to reach thermostat to test if the attic fan is working. Thermostat should be set between 110F and 120F. Note the open junction box. This is a safety concern. Recommend repairs/replacement by a licensed electrician.

15:18 October 10, 2009 Page 7 of 17 Attic (Continued) 8. House Fan: Not energy efficient recommend not using. Recommend adding a wood cover in the attic and covering it with insulation. 9. Wiring/Lighting: 110 VAC lighting circuit 10. Bathroom Fan Venting: Not properly vented The duct work needs to be vented to the exterior to comply with the building code. Basement Main Basement 1. Ceiling: Dry wall 2. Walls: Paint 3. Floors: Carpet and concrete 4. Floor Drain: Surface drain 5. Doors: Sliding glass 6. Windows: Sliding with aluminum frame. 7. Electrical: 110 and 240 V 8. HVAC Source: Ducted air system 9. Bsmt Stairs/Railings: Carpeted stairs Air Conditioning right side of home AC System 1. A/C System Operation: Functional Does not appear to have been serviced during the past year per the manufacturer's recommendation. The unit is near the end of its normal life expectancy of 10 to 15 years 2. Condensate Removal: PVC 3. Exterior Unit: Frigidaire 4. Model Number: FS3BA-042KA Serial Number: FSAO10506095 5. Area Served: Whole house Approximate Age: 13 years old (Mfr 1995) 6. Fuel Type: 208-230 VAC Temperature Differential: 14 degrees 7. Type: Central A/C Capacity: 3 1/2 ton 8. Refrigerant Lines: Low pressure and high pressure 9. Electrical Disconnect: Properly located 10. Exposed Ductwork: Metal 11. Blower Fan/Filters: Same blower for heating and cooling system 12. Thermostats: Same thermostat for both cooling and heating

15:18 October 10, 2009 Page 8 of 17 Family Room Fireplace 1. Fireplace Construction: Stone Fireplace/Wood Stove 2. Type: Wood burning 3. Smoke Chamber: Fire brick 4. Flue: Tile 5. Damper: Metal 6. Hearth: Flush mounted Heating System Utility room Heating System 1. Heating System Operation: Appears functional System does not appear to have been serviced per manufacturer's instructions, within the last year.* 2. Manufacturer: Carrier 3. Model Number: 58TUA100-20 Serial Number: 1402A61313 4. Type: Forced air/ ducted system Capacity: 100,000 btu 5. Area Served: Whole house Approximate Age: 19 years old (Mfr 14th week of 1992) 6. Fuel Type: Natural gas 7. Heat Exchanger: 5 Burner 8. Unable to Inspect: 80% 9. Blower Fan/Filter: Blower fan operating properly at time of inspection Filter was dirty; replaced by this inspector at the time of the inspection. 10. Distribution: Air duct system 11. Flue Pipe: Single wall 12. Humidifier: The only recommended type of whole house humidifier has a metal mesh pad with water trickling over it and hot air blowing across the mesh or the 2008 steam humidifiers. Inspecting the operability of the humidifier is not part of this inspection. 13. Thermostats: Same thermostat for both cooling and heating

15:18 October 10, 2009 Page 9 of 17 Plumbing The inspector does not operate water supply or emergency pressure valves since turning them on or off may cause them to begin leaking. The inspector does not evaluate underground pipes or pipes inside walls for size, leaks or corrosion; nor perform tests for gas leaks. Water quality is not part of this inspection. that have been turned off, or otherwise disabled. The inspector does not light pilot lights or operate systems 1. Service Line: copper 2. Main Water Shutoff: Basement 3. Water Lines: Copper Minor corrosion* 4. Drain Pipes: PVC DWV 5. Vent Pipes: PVC DWV 6. Gas Service Lines: Black steel pipe Basement Water Heater 7. Water Heater Operation: Functional at time of inspection Water heater has exceeded its life span (8 to 12 years for gas and electric), Recommend planning on replacing the water heater in the near future. 8. Manufacturer: Kenmore (Sears) 9. Model Number: 153.338750 Serial Number: M96406852 10. Type: Natural gas Capacity: 75 gallon 11. Approximate Age: 13 years old (Mfr 1996) Area Served: Entire home 12. Flue Pipe: Single wall 13. TPRV and Drain Tube: Copper Bathroom Basement Bathroom 1. Ceiling: Dry wall 2. Walls: Paint 3. Floor: Ceramic tile Cracked tile 4. Doors: Hollow wood 5. Electrical: GFCI GFCI will not reset, Suggest repairs/replacement by a licensed electrician 6. Counter/Cabinet: Composite and wood

15:18 October 10, 2009 Page 10 of 17 Bathroom (Continued) 7. Sink/Basin: Molded single bowl 8. Faucets/Traps: Single lever faucet 9. Tub/Surround: Fiberglass tub/shower one piece Drain plug missing 10. Toilets: American Standard 11. Ventilation: Exhaust fan Metal duct does not terminate outdoors as required by the building code. (photo taken in the utility room) Also note the junction box in need of a cover. This is a safety concern and an electrical code requirement. 1st floor Bathroom 12. Ceiling: Dry wall 13. Walls: Paint 14. Floor: Ceramic tile 15. Doors: Hollow wood 16. Electrical: GFCI 17. Counter/Cabinet: Composite and wood 18. Sink/Basin: Molded single bowl 19. Faucets/Traps: Hot and Cold water faucet 20. Toilets: Kohler 21. HVAC Source: Ducted air system 22. Ventilation: Exhaust fan 2nd floor master Bathroom 23. Ceiling: Dry wall 24. Walls: Paint 25. Floor: Ceramic tile 26. Doors: Pocket Door will not close properly 27. Windows: Single pane with storm window The window will not open 28. Electrical: GFCI Outlets loose on the wall. (both on the same wall) Recommend licensed electrician. 29. Counter/Cabinet: Composite and wood 30. Sink/Basin: Molded dual bowl 31. Faucets/Traps: Single lever faucet 32. Shower/Surround: Ceramic tile Regrouting is needed, Caulking need at shower base 33. Toilets: American Standard 34. HVAC Source: Ducted air system 35. Ventilation: Exhaust fan 2nd floor front- middle Bathroom 36. Ceiling: Dry wall 37. Walls: Wallpaper 38. Floor: Ceramic tile

15:18 October 10, 2009 Page 11 of 17 Bathroom (Continued) 39. Doors: Hollow wood 40. Windows: Single pane with storm window The window will not open 41. Electrical: GFCI Please note the GFCI reset also will reset the duplex outlet in the first floor bathroom. 42. Counter/Cabinet: Composite and wood 43. Sink/Basin: Molded dual bowl 44. Faucets/Traps: Single lever faucet 45. Tub/Surround: Plastic tub and surround Tub/shower fixture is leaking. Also no control (on and off switch) was found for the whirlpool tub. Recommend a licensed plumber 46. Toilets: Kohler 47. HVAC Source: Ducted air system No damper on this partial register. Ensure duct does not extend behind the bathroom cabinet. Modifications may be necessary. 48. Ventilation: Exhaust fan 2nd floor front- far left Bathroom 49. Ceiling: Dry wall 50. Walls: Paint 51. Floor: Ceramic tile 52. Doors: Hollow wood 53. Electrical: GFCI 54. Counter/Cabinet: Composite and wood 55. Sink/Basin: Molded dual bowl 56. Faucets/Traps: Single lever faucet 57. Shower/Surround: Plastic surround Unable to get warm water. Valve may need adjustment. Recommend corrective action by a licensed plumber. 58. Toilets: American Standard 59. Ventilation: Exhaust fan Duct work needs to be vented to the outdoors.

15:18 October 10, 2009 Page 12 of 17 Kitchen 1st Floor Kitchen 1. Cooking Appliances: Thermador and Kenmore Gas surface unit by Thermador, Electric oven by Kenmore. 2. Ventilator: Non Duct microwave vent 3. Disposal: In-Sinkerator 4. Dishwasher: Miele 5. Air Gap Present? Yes No 6. Refrigerator: Sub-Zero This large green filter holder is found in the utility room (near the water heater). Recommend getting all information about this filter from the home owner. It appears to be a filter for the ice maker. 7. Microwave: Kenmore 8. Sink: SS single basin 9. Electrical: GFCI 10. Plumbing/Fixtures: Single lever faucet There is also an Insinkerator Instant Hot that is functional. Under the sink is a filter for the drinking water tap located to the right of the kitchen sink faucet. 11. Counter Tops: Corian 12. Cabinets: Cabinets appear to be in serviceable condition 13. Ceiling: Dry wall 14. Walls: Paint 15. Floor: Ceramic tile 16. Windows: Casement No screen, also unable to open the window. 17. HVAC Source: Ducted air system

15:18 October 10, 2009 Page 13 of 17 Laundry Room/Area 1st Floor Laundry Room/Area 1. Ceiling: Dry wall 2. Walls: Paint 3. Floors: Ceramic tile 4. Electrical: 110 and 240 V 5. HVAC Source: Ducted air system 6. Laundry Tub: PVC 7. Laundry Tub Drain: PVC DWV 8. Washer Hose Bib: Appears serviceable. 9. Washer and Dryer Electrical: Not conveying 10. Dryer Vent: Metal flex Vent will not close on the outside rear of the home. 11. Washer Drain: Wall mounted drain Final Comments There are several electric heaters in this home. They are all in working order. Some are wall mounted and have the thermostats on the unit. Others are electric baseboard (found in some of the bedrooms). These heaters are supplemental. The central gas fired heating furnace should provide adequate heat. Perhaps they were needed when there was a heat pump system that may have been installed prior to the gas fired furnace.

15:18 October 10, 2009 Page 14 of 17 Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds 1. Vegetation: Shrubs and plants Shrubs too close to the cladding; recommend it be trimmed back at least 6". Keep mulch and all growth at least 6 inches away from the foundation wall. 2. Grading: Minor slope to flat It is important that the slope is sufficient to ensure that water does not pool against the foundation wall. Exterior Surface and Components 3. Whole house Exterior Surface Type: Brick and wood Wood siding needs to be checked thoroughly to ensure that there is no wood rot. There are several areas near the brick chimney, left side of the house that need attention. Recommend a licensed contractor to make necessary repairs. 4. Trim: Wood Trim near the left side of the garage has peeling paint. Check for wood rot and replace if necessary. Scraping and painting advised. 5. Patio Door: Sliding glass doors Screen has several holes in it. Recommend it be replaced. 6. Windows: Single pane wood frame with storm window Several windows are painted shut. They all need to be operable. Roof 7. Downspouts: Adequate except as noted Several downspouts have been squashed so they almost shut. They should be straightened or replaced. 8. Leader/Extension: Splash blocks Relocate splash blocks to make them effective, many are not under the downspouts. Electrical 9. Basement Electric Panel Manufacturer: Gould Hot(live) wire open inside the panel. Recommend corrective action by a licensed electrician.

15:18 October 10, 2009 Page 15 of 17 Marginal Summary (Continued) 10. Basement Electric Panel Breakers: CU Several breakers not labeled correctly at the panel. Many just say 'lights'. Attic 11. Main Attic Ventilation: Gable and soffit vents Evidence of a mold like substance on several of the 2X4's of the truss system. I do recommend that it be remediated. This is also an indication that there is not adequate ventilation in this attic. It is important that the attic fan is working when the attic temperature reaches 110F. 12. Main Attic Insulation Depth: 0" to 6" Recommend additional insulation be installed; total of 12" needed. There should be as much insulation over the top of the attic stairs as found elsewhere in the attic. Sometimes a light wood frame is built with hinges on one side. Insulation is fastened to the top and it is pushed to the side when entering the attic. 13. Main Attic Attic Fan: Thermostatically controlled Unable to reach thermostat to test if the attic fan is working. Thermostat should be set between 110F and 120F. Note the open junction box. This is a safety concern. Recommend repairs/replacement by a licensed electrician. Heating System 14. Utility room Heating System Blower Fan/Filter: Blower fan operating properly at time of inspection Filter was dirty; replaced by this inspector at the time of the inspection. Bathroom 15. Basement Bathroom Floor: Ceramic tile Cracked tile 16. Basement Bathroom Tub/Surround: Fiberglass tub/shower one piece Drain plug missing

15:18 October 10, 2009 Page 16 of 17 Marginal Summary (Continued) 17. 2nd floor master Bathroom Doors: Pocket Door will not close properly 18. 2nd floor master Bathroom Windows: Single pane with storm window The window will not open 19. 2nd floor master Bathroom Electrical: GFCI Outlets loose on the wall. (both on the same wall) Recommend licensed electrician. 20. 2nd floor master Bathroom Shower/Surround: Ceramic tile Regrouting is needed, Caulking need at shower base 21. 2nd floor front- middle Bathroom Windows: Single pane with storm window The window will not open 22. 2nd floor front- middle Bathroom Tub/Surround: Plastic tub and surround Tub/shower fixture is leaking. Also no control (on and off switch) was found for the whirlpool tub. Recommend a licensed plumber 23. 2nd floor front- middle Bathroom HVAC Source: Ducted air system No damper on this partial register. Ensure duct does not extend behind the bathroom cabinet. Modifications may be necessary. 24. 2nd floor front- far left Bathroom Shower/Surround: Plastic surround Unable to get warm water. Valve may need adjustment. Recommend corrective action by a licensed plumber. Kitchen 25. 1st Floor Kitchen Windows: Casement No screen, also unable to open the window. Laundry Room/Area 26. 1st Floor Laundry Room/Area Dryer Vent: Metal flex Vent will not close on the outside rear of the home.

15:18 October 10, 2009 Page 17 of 17 Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Attic 1. Main Attic Bathroom Fan Venting: Not properly vented The duct work needs to be vented to the exterior to comply with the building code. Bathroom 2. Basement Bathroom Electrical: GFCI GFCI will not reset, Suggest repairs/replacement by a licensed electrician 3. Basement Bathroom Ventilation: Exhaust fan Metal duct does not terminate outdoors as required by the building code. (photo taken in the utility room) Also note the junction box in need of a cover. This is a safety concern and an electrical code requirement. 4. 2nd floor front- far left Bathroom Ventilation: Exhaust fan Duct work needs to be vented to the outdoors.