PRODUCTS INSTALLATION INSTRUCTIONS NO. NAME MODEL: ERF999PL-B/B-IN Description:Pressure-raised Wall Mounted Shower Mixer QTY. Hand Shower Hand Shower Holder Plug Screw Handle 7 Cartridge 8 Fixed Seat Assembly 9 Body Assembly 0 Cartridge() Shower Hose 7 Air bag Cartridge() Handle Plug Can match the other 8 9 0 Can match the other NO. NAME Connectors Assembly A QTY. INSTALLATION DIMENSION Unit:mm 8
B HELPFUL TOOLS Pencil Impact Drill Tape Measure Spanner Screwdriver Flashlight Teflon tape Points for attention before installation Before installing the new mixer, it is essential that you thoroughly flush through the supply pipes in order to remove any remaining swarf, solder or other impurities. Failure to carry out this simple procedure could cause problems or damage to the workings of the mixer. Work water pressure: for cold water: min 0.0 MPa for hot water: min 0.0 MPa(.m Drop) If the pictures and statements in the Installation Specifications is unconfirmed with practicality, please take practicality as standard. C INSTALLATION STEP Installation step for exposed faucet 0.. Drill hole in wall refer to illustrated rough-in dimensions, insert the anchor and fix the fixed seats with screw. (Note: The left and right fixed seats should be in a horizontal position and center distance between them should be 0.mm.). Tighten connectors to fixed seats. (Note:Don't over tighten to avoid damage of thread). 8
H MAINTENANCE CAUTION: Always turn water OFF before removing existing or disassembing the faucet. faucet handles to relieve water pressure and insure that complete water shut-off has been accomplished.. Place washer into coupling nut, connect faucet to connectors and tighten them. To keep the surface clean and bright, please clean the faucet regularly,please abide by the following procedures:. Use rinsing water and soft cloth, clean bilge and bilge membrane on the surface to the best of the abilities.. Cleaned the residua with the following cleansers only. Soft liquid cleanser. Colorless glass cleanser, totally soluble powder cleanser without abrasive capability.(mixed by instructions.) No abrasive cleansers waxes. Never use cleanser, emery cloth or handkerchief which can rub. Never use cleaners containing abrasive cleansers, ammonia,bleach, acids, waxes, alcohol, solvents or other products not recommended for chrome.. (a)draw the install distance of hand shower holder with a pencil, and drill holes with impact drill.. After cleaning, use rinsing water to clean all cleanser immediately and drying with a soft cotton cloth.. Carefully dismantle the aerator regularly, rinse under clean running water until any loose debris is cleared to avoid the influence to water outflow. I (b)plug anchor into the holes, fix the hand shower holder on the wall. SPECIAL STATEMENT The products installation instruction is written in accordance with the latest product information, following the sustainable development strategy of the Company, to improve continually the produce's specification, performance etc.,subject to change without notice. (The Company reserves the right to interpret). (a)connect one end of shower hose to faucet, and the other end connect to hand shower after insert a washer. (b)connect the hot and cold supply to faucet, hot supply at left and cold at right,when facing the wall. (Note:Don't over tighten to avoid damage of thread.). With installation completed, check all connections for leaks. 0 8 8
Installation step for concealed faucet 0 70-. Refer to illustrated rough-in dimensions embed hot supply at left and cold at right, when facing the wall. (Note: The hot supply outlet and cold supply outlet should be in a horizontal position and center distance between them should be 70-0mm.) Question 8: What are the advantages compared with the normal hot and cold taps and thermostatic mixers? Answer: The normal hot and cold taps: Pros: Many optional products. Cons: The water flow rate will effect greatly by the temperature and pressure from the water inlet. Result in hot water can not be supply continuously. Thermostatic Faucet: Pros: A stable temperature of shower water. Cons: Normally in a high price with complex structure. The thermostatic Faucet needs higher requirement on the pressure than normal faucet. The pressure should greater than 0.MPa. (Note: 0.MPa equivalent to 0 meters height difference) Wall Mounted Shower Bar: There are no moving parts inside the Faucet. The reliable structure can be used in any environment, especially in the situation when the pressure only has 0.0MPa. (Note: 0.0MPa equivalent to. meters height difference) Wall Mounted Shower Bar not only ensures a stable water temperature, but also maintained the shower water at over -L/MIN, to meet the comfortable requirements of shower. G GB. (a)cover the escutcheons onto conectors. SPECIFICATION This technical product information is exclusively for the installer or trained specialists. Please pass these instructions on to the user. Application: Operation with unpressurized storage heaters is not possible. Use for indoor public places and common residence. (b)tighten connectors with teflon tape to water supplies. (c)rorate the escutcheons to against wall. Specifications Operating pressure: for cold water: for hot water: Test pressure: water inlet temperature: Environment temperature: (Note:Don't over tighten to avoid damage of thread). min 0.0 MPa min 0.0 MPa(.m Drop). MPa If static pressure exceeds bar, a pressure-reducing valve must be fitted. Avoid major pressure differences between hot and cold water supply. Installation: Flush piping system prior and after installation of fitting thoroughly (Consider EN 80)! Fitting a temperature limiter is possible. Function: Check connections for leaks and check function of fitting. Maintenance: Inspect and clean all components and replace if necessary. Shut off water supply for maintenance work. When installing the cartridge, ensure that the seals are correctly seated. Tighten the screws evenly and alternately. Replacement parts: see exploded drawing. Care: see Care Instructions.. Place washer into coupling nut, connect faucet to connectors and tighten them. 8 8 9
F QUESTIONS AND ANSWERS Question : How to use Wall Mounted Shower Bar? Answer: Procedure (Please refer to Page : FLOW ADJUSTMENT INSTRUCTION) In the initial installation, adjust the maximum and minimum flow by setting the connector. Setting the connector of hot water: Rotate the temperature adjustment knob toward to + until reach MAX position. With the HOT water handle ONLY to MAX position, carefully advance the connector of hot water position to the lowest acceptable water flow rate by using screwdriver or a coin. As the temperature of water is in a high level temporarily, do not touch the water to avoid burn injury. Setting the connector of cold water: With both of HOT water and COLD water at MAX position, rotate the temperature adjustment knob from + toward to - until to reach acceptable temperature. Rotate the connector of COLD water position to reach an acceptable water flow rate by using screwdriver or a coin. Procedure (Please refer to Page : USAGE INSTRUCTION). Rotate the temperature adjustment knob toward to - until to MAX position;. Rotate the COLD water handle to MAX position;. Rotate the HOT water handle to MAX position;. Rotate the temperature adjustment knob slowly from - toward to + until reach an acceptable temperature. (Advance the knob clockwise to + will increase temperature, while advance counterclockwise to - will reduce temperature.. Rotate hot water handle to adjust flow rate while feeling too much water flow, then rotate the temperature adjustment knob to acceptable temperature.. (a)draw the install distance of hand shower holder with a pencil, and drill holes with impact drill. (b)plug anchor into the holes, fix the hand shower holder on the wall.. Connect one end of shower hose to faucet, and the other end connect to hand shower after insert a washer. Question : the temperature of shower water is not in an acceptable state? Answer: First check with rotating the temperature adjustment knob toward to + until to MAX position. If the temperature is still not acceptable, check the water temperature in the solar water heater storage. (Note:Don't over tighten to avoid damage of thread.) Question : Overload or little shower water flow rate? Answer: If the water supplied condition has changed greatly after installation, which result in an overload or little water flow rate. Please follow procedure to reset the cold and hot connector. Do not touch the water to avoid burn injury while adjusting. Question : The shower water flow rate is little after using the faucet for a while? Answer: As much water impurities existing in some region, it will stem in the filter of water inlet after longtime using. After adjusting the connector clockwise to close state, remove the other end of connector with a screwdriver or a coin, then take out the filter and rinsing with water. Re-assemble the filter and connectors. Please follow the procedures to reset the cold and hot water connector. Do not touch the water to avoid burn injury while adjusting. 关闭. With installation completed, check all connections for leaks. 打开 Question : Can we install the Wall Mounted Shower Bar in other places? Answer: The place can installed a normal cold and hot water faucet, also will suitable for Wall Mounted Shower Bar which can obtain an effect of low pressure with large flow rate. Question : If the shower head and hose can be replaced with other products? Answer: Please use the matching patented shower head and hose with this product, otherwise will affect the result. Question 7: How to do for the little hot water flow rate after setting the connector of hot water? Answer: Please inspect if the hot water pipe of the solar water heater is blocked with foreign matter or diameter is too small. 8 8 8
D E FLOW ADJUSTMENT INSTRUCTION USAGE INSTRUCTION Flow adjustment instruction for concealed faucet MAX MAX.Rotate the temperature adjustment knob toward to + until to MAX position..rotate the HOT water handle ONLY to MAX position..rotate the temperature adjustment knob toward to - until to MAX position. NOTE: CAUTION HOT WATER!.Rotate the COLD water handle to MAX position..rotate the HOT water handle to MAX position..rotate the connector of HOT water position to the lowest acceptable water flow rate. NOTE: CAUTION HOT WATER!.Rotate the temperature adjustment knob slowly from - toward to + until reach an acceptable temperature. (Advance the knob counterclockwise to + will increase temperature, while advance clockwise to - will reduce temperature.) Small Large.Rotate the COLD water handle to MAX position (both of HOT water and COLD water at MAX position). ter Acceptable Temperature.Please rotate hot water handle to adjust flow rate while feeling too much water flow, then rotate the temperature adjustment knob to acceptable temperature..rotate the temperature adjustment knob from + toward to - until to reach acceptable temperature. er.rotate the connector of COLD water position to acceptable water flow rate.. the HOT water. ter er 7. the COLD water. 7. the HOT water. Large 8. the COLD water. Small Adjust the flow 8 8 7