i00, Gen II i50, Gen II Submittal Data Date: Project Name: Project #: Bid Date: Fuel Type: Natural Gas Propane Model Selection: i00 i50 City State Zip: Engineer: Contractor: KEY FEATURES Stainless (36L) Heat Exchanger Flexible-Floating Design, stress-relieving and thermal shock resistant Multi-Unit - Masterless cascading with common venting Gas Pressures - Operates on gas pressure range of.5"- 4" w.c. Designed and Built in the U.S. 3.5" Color Touch Screen - access to usage data, troubleshooting, and parts wear PERFORMANCE Turndown Ratio of 7: (i00) & 8.3: (i50) per unit. Cascade up to 0 units with common venting for a total of over 500MBH and a 83: total turndown ratio Model Temperature Rise (ΔT) F 40 50 60 70 80 90 00 Flow (GPM) i00 9.4 7.5 6.3 5.4 4.7 4. 3.8 i50.7 9.3 7.8 6.7 5.8 5. 4.7
i00, Gen II i50, Gen II Specifications PARAMETERS MODEL i00, Gen II i50, Gen II Type Fuel Indoor/Outdoor, Wall-Hung, Fully Condensing, Direct Ignition Preset for NG / LP Convertible Minimum / Maximum Input (BTU/hr) 30,000 / 99,950 30,000 / 50,000 Thermal Efficiency 94% 9% Energy Factor 0.93 N/A Dimensions H X W X D (Inches) Weight (LBS) Water and Gas Connections Minimum Flow Rate Venting Materials 6. X 7.7 X 5 (3.9 CU. FT) 93 LBS 3/4" NPT 0.6 GPM Sch. 40 PVC, Sch. 40 CPVC, Polypropylene, Stainless Steel (AL9-4C) Max 3 Vent Length - Single Pipe / Power Vent 00 ft, deduct 5 ft per 90 elbow 30 ft, deduct 5 ft per 90 elbow Max 3 Vent Length - Two Pipe / Direct Vent 00 ft, deduct 5 ft per 90 elbow 65 ft, deduct 5 ft per 90 elbow Max Vent Length - Single Pipe / Power Vent ( not allowed at elevations above 4,000 ft) Max Vent Length - Two Pipe / Direct Vent ( not allowed at elevations above 4,000 ft) 6 ft, deduct 5 ft per 90 elbow N/A ft, deduct 5 ft per 90 elbow N/A Installation Location Ambient Temperature 40 F 30 F Safety Flame Rod, Thermal Fuse, Overheat Prevention Device, Fan Speed Monitor, Flue Temperature Monitor, Blocked Vent Detector, Water Shut-Off Valve, X0A Fuse, Dual Flame Sensing Water Pressure Min / Max (PSI) 30 / 50 NG/LP - Minimum Static Gas Pressure / Black Iron (non-corrugated) 5 6 NG/LP - Minimum Static Gas Pressure 3/4 Black Iron (non-corrugated).5 NG/LP - Minimum Dynamic Pressure at Full Firing Rate 0.5 NG/LP - Maximum Static Gas Pressure 4 Gas Pressure for Adjustments Electrical Power Consumption 8 for NG, for LP 0V AC, 60 Hz 500W (Max 4. Amps), 8W (Standby) FEATURES & PERFORMANCE i00, Gen II i50, Gen II Cascading Heat Exchanger Masterless, 0 units Stainless 36L Hot Water Capacity (35F Rise) 0.8 3. Hot Water Capacity (45F Rise) 8.4 0.3 Hot Water Capacity (77F Rise) 5.0 6.0 Domestic Hot Water Temperature Settings 00 85 F Warranty (with recirculation, and unlimited thermal cycles) Commercial: Heat Exchanger Coil 6 years, Parts year Residential: Heat Exchanger Coil 5 years, Parts 5 years, Labor year
7.8 [98] 4.6 [7].9 [74] 0.6 [4] MOUNTING WALL SURFACE 5.0 [380] 4.3 [363] Dimensions Shown Are In Inches (mm) i00, Gen II i50, Gen II Dimensional Specifications.4 [37] 7.8 [45] 6.4 [670] BOTTOM MOUNTING BRACKET.9 [74] 6.6 [68] POWER CORD CONDENSATE DRAIN FRONT VIEW 3/4" DRAIN SIDE VIEW POWER CORD 6.6 [68] l Specifications.9 [74].0 [5] CONDENSATE DRAIN Dimensions Shown Are In Inches (mm) 3.0 [75] BOTTOM VIEW 5.0 [380] 4.3 [363] 7.8 [45].4 [37]
8.5 External Recirculation The following illustrations provide possible external recirculation options. Recirculation is required for system to function properly. i00, Gen II i50, Gen II External Recirculation Recirculation Line Recirculation Line Hot Water Return Hot Water Return HOT WATER FIXTURES HOT WATER FIXTURES Cold Water Cold Supply Water Supply Gas Supply Gas Supply Expansion Expansion Tank Tank Hot Water Supply Hot Water Supply "RESTAURANT" OPTION WITH NO BUILDING RECIRCULATION HOT WATER FIXTURES Cold Water Supply Min. 3 gpm @ ft. of Head Gas Supply Expansion Tank Hot Water Supply 3 iq5 Water Connections May 08 - Revision 0
i00, Gen II i50, Gen II Pressure Drop & Clearance Requirements 3. High Elevation Installations 5 57.8 0 46. 5 34.7 0 3. 5.6 0 For operation at elevations above,000 feet, the hot0 water delivery output should be reduced by 4% for each,000 feet above sea level. 3 4 5 6 7 8 Pressure Drop (ft of Head) Pressure Drop (psi) Pressure Drop 0 Flow Rate (gpm) 3.3 Clearance Requirements In order for the water heater to operate properly and efficiently, the clearances specified in the table are required. Location Clearances Required Recommended From From Non Service Clearance Top 6 (5 mm) (50.8 mm) (305 mm) Back Sides (5.4 mm) / (.7 mm) Required Mounting Clearances Front (5 mm) (50.8 mm) 30 (76 mm) Location From From NonBottom (305 mm) (305 mm) (305 mm) Service clearances aretop suggested to allow for normal service. 6 (5. cm) (50.8 cm) Mounting bracket automatically sets 5/8 this dimension.. (5.8 mm) Back Front Bottom Required Location Recommended From From Non Service Clearance Back Sides (5.4 mm) / (.7 mm) (5.4 mm) (5. cm) (5. cm) 30 (76. cm) 5/8 (5 / (.7 mm) 5/8 (5 (5. cm) (5. cm) 30 (76 (30.4 cm) (30.4 cm) (30 (5.4 mm) Service clearances are suggested to allow for normal Mounting bracket automatically sets this dimension. i00, Gen II i50, Gen II Electrical Data Electrical power required for the water heater is 0V AC, 60 Hz. The circuit breaker shall be a minimum of 5 amps. Only one 6 (5. cm) (50.8 cm) (30.4 cm) water heater should be plugged into an outlet. Please ensure correct polarity of outlet before plugging in heater. Top Front Bottom Electrical Data (30.4 cm) (30.4 cm) (30.4 cm) Service clearances are suggested to allow for normal service. Mounting bracket automatically sets this distance. 3.4 Connections Electrical power required for the water heater is 0V AC, 60 Hz. The circuit breaker shall be a minimum of 5 amps. Only one water heater should be plugged into an outlet. Please ensure correct polarity of outlet before plugging in heater 3.5 Exhaust Gas Standards Connections Item Description Specification (30 Sides Serv Clear
Number of Units 3 4 5 6 7 8 9 0 PV = Power Vent DV = Direct Vent Venting Maximum Vent Lengths (ft) Maximum Pipe Length in Feet i00, Gen II i50, Gen II Venting Venting " Diameter 3" Diameter Duct 4" Diameter 6" Diameter 8" Diameter Type Number Venting " 3" 4" 6" 8" i00 i00 Size i50 i00 i50 i00 i50 i00 i50 Of Units Type pipe - PV 6 00 Model 30 i00 i00 i50 30i00 i50 - i00 i50 - i00 -i50 - pipe - DV Pipe-PV 00 65 6 00 00 30 6500 30 - - - - pipe - PV - Pipe-DV - - 00 00 65 3000 65- - - - pipe - DV - Pipe-PV - - 00 6500 30 - - - - pipe - PV - Pipe-DV - - 00 3000 6500 30 - - pipe - DV - Pipe-PV - - 50 3000 3000 00 30 3 65 - - pipe - PV - Pipe-DV - - - - 50 3000 00 30 65 - - pipe - DV - Pipe-PV - - - - 00 00 30 4 65 - - pipe - PV - Pipe-DV - - - - 00 00 30 65 - - Pipe-PV 00 30 pipe - DV 5- - - - - 00 65 - - Pipe-DV 00 65 pipe - PV - - - - - 00 30 - - Pipe-PV 00 30 pipe - DV 6- - - - - 00 65 - - Pipe-DV 00 65 pipe - PV - - - - - 50 45 - - Pipe-PV 50 45 pipe - DV 7- - - - - 75 45 - - Pipe-DV 75 45 pipe - PV - - - - - 00 30 00 30 Pipe-PV 00 30 00 30 pipe - DV 8- - - - - 50 30 00 65 Pipe-DV 50 30 00 65 pipe - PV - - - - - - - 00 30 Pipe-PV 00 30 pipe - DV 9- - - - - - - 00 65 Pipe-DV 00 65 pipe - PV - - - - - - - 00 30 Pipe-PV 00 30 pipe - DV 0 - - - - - - - 00 65 Pipe-DV 00 65 Note: Reduce the maximum equivalent length above by 5 feet per 90 elbow and by Note: Reduce the maximum equivalent feet per length 45 above elbow. by Do 5 feet not exceed per 90 above elbow limits. and by feet per 45 elbow. Do not exceed above limits. Exhaust Exhaust Exhaust Intake Air -Pipe Direct Vent -Pipe Direct Vent Version 8.8