TDE, TDE-10M, TDE-15M, TDE-S3, TDE-S4 Temperature Sensor

Similar documents
DDC111 and DDC111-2 room control modulel

Technology for building automation. Ambient Air Humidity and Temperature Probes HT12 and HTF12. Device Description. Contents

Instruction manual EN

PFAFF. 560/580 steam ironer. Service Manual. german engineering

EN Instruction manual

VISION H. Instruction manual

MANUAL Overflow sensor NVF-104/34-PF

Engineering Guideline. pac- Carriers Type Universal

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

Installation instructions

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

EXTERNAL VENETIAN BLIND

R4952. SELECT wash basin lifter. Operation and maintenance manual

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Temperature Sensor TRG Original Installation Instructions English

Translation of the assembly instructions with operating instructions and technical appendix

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

FSW300 Series Flow Switch

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

JOKE Basic-Clean. Ultrasonic cleaners. Instruction Manual

Operating instructions

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Speedpocket. Sewing unit for runstitching of rectangular piped pockets. Operating Instructions. Installation Instructions. Service Instructions

VIESMANN. Installation instructions VITODENS 200-W. for contractors

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

8.0 Table of Contents. Monitoring system WIREM

OPERATION AND INSTALLATION MANUAL GUÍA DE OPERACIÓN E INSTALACIÓN MODE D EMPLOI ET MANUEL D INSTALLATION

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

Product Manual Glue Applicators MS 80 and MS 200

Operating and installation instructions

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Technical Data. Dimensions

OPERATING MANUAL RAY-NC 1000 SERIES

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

EN Z Subject to change due to technical improvements! Operating instructions

Mobile measurement technology for HV components

Operating Manual. VIENNA Hot Display

Automatic switch attachment Standard Installation Instructions

Room Temperature Sensor

Thermocouples and Resistance Thermometers

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

Operating Instructions

Conductivity Electrode LRG Original Installation Instructions English

50 - WMS // Straight resistance thermometers with a metal thermowell and a built-in measurement insert

Operating instructions Mini Jet Ionisator. Air Line V01

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Operation Manual Airbrush Compressor AH28A ARTICLE 34247

RAR... Photocell Detectors. Building Technologies Division

3-way switching valve

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

Operation and installation

Operating Manual MS220DA

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

Cutting Tools. Hydraulic cutting heads Hydraulic drive units Hydraulic systems

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Duct Air Quality Sensors

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation instructions PYROMAT ECO. for contractors PYROMAT ECO GB 8/2012 Dispose after installation.

marvac The innovative system for efficient smoke evacuation

Liebherr's engineering excellence in Germany provides the largest selection of freezers, refrigerators and wine refrigerators worldwide.

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Instruction Manual. Electronic gas and smoke detector GRM

Gas cylinder scale Model GCS-1

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

PEPPERL+FUCHS GmbH

Installation, Operation & Service Manual

Room Air Quality Sensors

Digital Display DS 52 in wall housing. Order no

ECV SP GUE ALO CAT ICAL TECHN

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Operating Guide Safe Torque Off

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

HSGM Heißschneide-Geräte

NiteCool TCC-100/RCC-100

Supplement to operating and installation manual no for the VR 81 remote control unit

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Installation Instruction

Read these instructions before using and keep them available at all times!

Transcription:

Issue 2009-05-15 Datasheet 1.10-12.010-11-EN Temperature Sensor Temperature sensors TDE, TDE-10M, TDE-15M, TDE-S3 and TDE-S4 can be used in existing thermowells with an internal diameter from 6.5 mm. The temperature sensors are used to measure the temperature for all controllers und controller systems that have a sensor connection for the KP10 measuring element. Contents Page Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...3 ccessories (included in delivery)...3 ccessories (not included in delivery)...4 Installation...5 Installation...6 Connection...6 Temperature/voltage table for KP10, temperature range -20 C to 130 C...7 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения - Kieback&Peter GmbH & Co. KG Tempelhofer Weg 50, 12347 Berlin/Germany Telefon: +49 30 60095-0, Telefax: +49 30 60095-164 www.kieback-peter.de, info@kieback-peter.com

Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "TDE, TDE-10M, TDE-15M, TDE-S3, TDE-S4". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer. If the product is not used in accordance with this data sheet, the protection provided will be impaired. pplicable regulations must be observed when installing and using the device. Within the EU, these include regulations regarding occupational safety and accident prevention as well as those from the VDE (ssociation for Electrical, Electronic & Information Technologies). If the device is used in other countries, it is the responsibility of the system installer or operator to comply with local regulations. Mounting, installation and commissioning work on the devices may only be carried out by qualified technicians. Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recognize possible dangers due to technical training, knowledge and experience as well as knowledge of the appropriate regulations. Meaning of the Symbols WRNING Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided. CUTION Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided.! NOTICE Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not avoided. Note Indicates additional information that can simplify the work with the product for you. Notes on Disposal For disposal, the product is considered waste from electrical and electronic equipment (electronic waste) and must not be disposed of as household waste. Special treatment for specific components may be legally binding or ecologically sensible. The local and currently applicable legislation must be observed. Page 2 / 8

Item TDE TDE-10M TDE-15M TDE-S3 TDE-S4 Measuring element KP10 in protective sleeve for 10 to 130 C, IP65 around the protective sleeve, silicon connection cable Measuring element KP10 in protective sleeve for 10 to 130 C, IP65 around the protective sleeve, silicon connection cable Measuring element KP10 in protective sleeve for 10 to 130 C, IP65 around the protective sleeve, silicon connection cable Measuring element KP10 in protective sleeve for -20 to 130 C, IP67 around the protective sleeve, silicon connection cable Measuring element KP10 in protective sleeve for 0 to 50 C, IP65 around the protective sleeve, silicon connection cable Technical Data Function Measured variable Measuring element Temperature voltage transmitter Temperature KP10, 2.731 V at 0 C, TC = 10 mv/k Measuring tolerance <0.2 K Measuring range TDE, TDE-10M, TDE-15M: 10 to 130 C TDE-S3: -20 to 130 C TDE-S4: 0 to 50 C Time constant Protective sleeve Connection 63 s Cu, not pressure-tight 2-wire connection, silicon connection cable TDE, TDE-S3, TDE-S4: approx. 1.5 m long TDE-10M: approx. 10 m long TDE-15M: approx. 15 m long Degree of protection TDE, TDE-10M, TDE-15M: IP65 around the protective sleeve mbient humidity TDE-S3: TDE-S4: 0 to 95% r.h. non-condensing IP67 around the protective sleeve IP65 around the protective sleeve Dimensions Ø 6,0 50 L= 1.500 (TDE, TDE-S3, TDE-S4) L=10.000 (TDE-10M) L=15.000 (TDE-15M) ccessories (included in delivery) Pressure spring for thermowells with interior diameter > 7.5 mm. Page 3 / 8

ccessories (not included in delivery) 218KD: Heat-conductive paste Z5/TD1..4: Thermowells Z6/TD1..4: Thermowells Z5/TD1..4 Z6/TD1..4 218KD 18 24 SW 27 100 R ½" 87/137/187/287/387 Ø 10 Page 4 / 8

Installation WRNING! Only qualified technicians may install or remove the device. In addition to the generally applicable installation guidelines for working on pipelines, the following must be observed: The temperature sensor must be pushed into the thermowell and sensor case deep enough to allow for fault-free and accurate measuring of the temperature of the medium. The measuring length is 14 mm measured from the bottom of the protective sleeve. For improved thermal transfer between the thermowell and the measuring element, the measuring element should be fed into the thermowell with the heat-conductive paste. The supplied pressure spring is to be used with thermowell with an interior diameter of over 7.5 mm, so that the measuring element touches the inner wall of the thermowell, see figure "For use in thermowells with interior diameter > 7.5 mm.". Installation position Z5/TD1..4 Z6/TD1..4 For use in thermowells with interior diameter > 7.5 mm. 1 2 3 1 Pressure spring 2 Temperature sensor 3 Thermowell Page 5 / 8

218KD Z5/TD1..4 Z6/TD1..4 1 2 3 4 TDE TDE-S3 TDE-S4 218KD 5 6 7 Installation CUTION Electrical installation and device connection may only be carried out by qualified technicians, e.g. an electrician. Ensure that this process complies with guidelines from the VDE (ssociation for Electrical, Electronic & Information Technologies) and local wiring regulations. The device must be connected in accordance with the applicable system wiring diagram. Note When connecting temperature sensors of type to the control system, be sure to observe the correct polarity. Connection KP10 BN BU Page 6 / 8

Temperature/voltage table for KP10, temperature range -20 C to 130 C T (C) U (V) T (C) U (V) T (C) U (V) T (C) U (V) T (C) U (V) -20 2.53 10 2.83 40 3.13 70 3.43 100 3.73-19 2.54 11 2.84 41 3.14 71 3.44 101 3.74-18 2.55 12 2.85 42 3.15 72 3.45 102 3.75-17 2.56 13 2.86 43 3.16 73 3.46 103 3.76-16 2.57 14 2.87 44 3.17 74 3.47 104 3.77-15 2.58 15 2.88 45 3.18 75 3.48 105 3.78-14 2.59 16 2.89 46 3.19 76 3.49 106 3.79-13 2.60 17 2.90 47 3.20 77 3.50 107 3.80-12 2.61 18 2.91 48 3.21 78 3.51 108 3.81-11 2.62 19 2.92 49 3.22 79 3.52 109 3.82-10 2.63 20 2.93 50 3.23 80 3.53 110 3.83-9 2.64 21 2.94 51 3.24 81 3.54 111 3.84-8 2.65 22 2.95 52 3.25 82 3.55 112 3.85-7 2.66 23 2.96 53 3.26 83 3.56 113 3.86-6 2.67 24 2.97 54 3.27 84 3.57 114 3.87-5 2.68 25 2.98 55 3.28 85 3.58 115 3.88-4 2.69 26 2.99 56 3.29 86 3.59 116 3.89-3 2.70 27 3.00 57 3.30 87 3.60 117 3.90-2 2.71 28 3.01 58 3.31 88 3.61 118 3.91-1 2.72 29 3.02 59 3.32 89 3.62 119 3.92 0 2.73 30 3.03 60 3.33 90 3.63 120 3.93 1 2.74 31 3.04 61 3.34 91 3.64 121 3.94 2 2.75 32 3.05 62 3.35 92 3.65 122 3.95 3 2.76 33 3.06 63 3.36 93 3.66 123 3.96 4 2.77 34 3.07 64 3.37 94 3.67 124 3.97 5 2.78 35 3.08 65 3.38 95 3.68 125 3.98 6 2.79 36 3.09 66 3.39 96 3.69 126 3.99 7 2.80 37 3.10 67 3.40 97 3.70 127 4.00 8 2.81 38 3.11 68 3.41 98 3.71 128 4.01 9 2.82 39 3.12 69 3.42 99 3.72 129 4.02 10 2.83 40 3.13 70 3.43 100 3.73 130 4.03 Page 7 / 8

Page 8 / 8