OPERATING AND INSTALLATION MANUAL

Similar documents
Operation and Installation Manual. Accumulation Tanks. NADO 500/200v7 NADO 750/200v7 NADO 1000/200v7

StorMaxx CTEC Series Tanks

OPERATING AND INSTALLATION MANUAL

Storage Tanks Type NADO

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING and INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

17 OPERATING AND INSTALLATION MANUAL - EN

OPERATING AND INSTALLATION MANUAL

TANK TYPE INDIRECT WATER HEATERS

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

OPERATING and INSTALLATION MANUAL

ENAMELED INDIRECT WATER HEATERS

STORAGE TANKS NEWS WITH TRADITION

WATER HEATERS AND HOT WATER STORAGE TANKS

WATER HEATERS. Tradition from 1956

WATER HEATERS AND HOT WATER STORAGE TANKS

INDIRECT WATER HEATERS

Installation and Operating Manual

Page 1 SERVICE MANUAL. Little flow heaters SERVICE MANUAL

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

WATER HEATERS AND HOT WATER STORAGE TANKS

BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE BA-ST FE Hot Water Storage Tank with Coil

INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

Installer manual AHP/AHPS

16 XD Mk2 Inset Electric Fire

User and Installer manual NIBE UKV 20

Electric steam steriliser

Installer manual AHP/AHPS

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Nose and Ear Trimmer. 10,000 prize draw. Register online for NE3150. EXTRA year guarantee FREE rewards gallery

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

INSTALLATION AND OPERATION MANUAL

PANTHER P Automatic Boiler Operator's Manual

with insulated heating elements for water heaters INSTALLATION AND USER MANUAL WARRANTY CARD

TECHNOSKLO Ltd. Držkov

16 Ultiflame Inset Electric Fire

WATER HEATERS FOR CENTRAL UTILITY WATER ENSOL/1

Colt CoolStream Adiabatic Cooling & Ventilation System

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Specification / Type INTEGRA 400/100 INTEGRA 500/120 INTEGRA 800/200

ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26

Installation and operating instructions. DK energy storage and DK energy buffer

sustainable energy solutions

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

In cooperation with. sustainable energy solutions

Colt CoolStream Evaporative Cooling & Ventilation System

WATER HEATERS.

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE CONTROL

England. SMART CABIN kw. Purity to Nature Savings to Clients Comfort to Users

TECHNICAL PROPERTIES OF THE APPLIANCE

Components for solar heating systems

FIGARO. 08/52543/0 (UK) Issue 1

Leading European manufacturer of fireplace stoves and fireplace inserts

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

20L/D DEHUMIDIFIER Model Number: IG9800

Air-Water heat pump Small GT

Installation, operation and care. Pellmax UB. Burner not included Replaces:

FAVORIT W0P. EN User manual

INSTALLATION, OPERATION

High quality boiler stoves and fireplace inserts

WATER HEATERS EN - flyer 03/z/2018 Made in Poland

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Aquaflam Wood boiler stoves and fireplace inserts

FAVORIT W0P. EN User manual

02/ ver.1.1 WK 30M UK. Indesit Company UK Ltd Morley Way, Peterborough PE2 9JB

Condensing, pre-mixed, wall-hung gas boilers with water tank

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

The Professional s Choice

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Operating Instructions

KOSPEL S.A. UL. OLCHOWA KOSZALIN

STORM. Bottom-Load. Water Dispenser User Manual

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

FAVORIT 34502VI0. EN User manual

One Cup. Please read and keep these instructions for future use

Bottled Water Dispenser User Manual

PRO-Air Shine. 10,000 prize draw. Register online for D5215. EXTRA year guarantee FREE rewards gallery

K 2.50 M. Operating Instructions PRESSURE WASHER /03_

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

30L Mini Oven with Twin Hotplates. Model: MA0080MO READ AND FOLLOW THESE INSTRUCTIONS. RETAIN FOR FUTURE REFERENCE

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

Leading European manufacturer of fireplace stoves and fireplace inserts. Fireplace inserts

LBF RANGE BALANCED FLUED WATER HEATERS

CRU-S Series Stainless Steel Condensate Recovery Unit

10,000 prize draw. instructions. EXTRA year guarantee FREE rewards gallery. details. Register online now!

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER WITH RELAY CONTROL

Transcription:

OPERATING AND INSTALLATION MANUAL STORAGE TANKS NADO 800/35v9 NADO 1000/35v9 Družstevní závody Dražice-strojírna s.r.o. (Works Cooperative - Dražice - Machine Plant, Ltd.) Dražice 69, 294 71 Benátky nad Jizerou tel.: +420 / 326 370 911 fax: +420 / 326 370 980 e-mail: export@dzd.cz

CONTENTS 1 PRODUCT TECHNICAL SPECIFICATION... 4 1.1 FUNCTION DESCRIPTION... 4 1.2 DESIGNING THE SIZE AND CONNECTION OF STORAGE TANK TO THE HEATING SYSTEM... 4 2 TECHNICAL PARAMETERS... 5 3 IMPORTANT WARNING... 6 4 TECHNICAL DESCRIPTION... 7 5 DISPOSAL OF PACKAGING MATERIAL AND NON-FUNCTIONING PRODUCT... 9-2 -

CAREFULLY READ THIS MANUAL BEFORE INSTALLING THE TANK! Dear Customer, The Works Cooperative of Dražice - Machine Plant, Ltd., would like to thank you for your decision to use a product of our brand. The product is not intended to be controlled by a) people (including children) with reduced physical, sensual or mental capacities, or b) people with insufficient knowledge and experiences unless supervised by responsible person, or unless properly instructed by such responsible person. The manufacturer reserves the right for engineering modification of the product. The product is designed for permanent contact with drinkable water. It is recommended to use the product in indoor environment with air temperatures from +2 C to +45 C and a relative humidity up to 80 %. Product s reliability and safety is proven by tests implemented by the Engineering Test Institute in Brno. Made in the Czech Republic. Meaning of pictograms used in the Manual Important information for heater users. Abiding by the recommendations of the manufacturer serves to ensure trouble-free operation and the long service life of the product. Caution! Important notice to be observed. - 3 -

1 PRODUCT TECHNICAL SPECIFICATION 1.1 FUNCTION DESCRIPTION Storage tanks serve accumulation of excessive heat from its source. The source may be a solid fuel boiler, heat pump, solar collectors, fireplace inserts, etc. The NADO type storage tanks serve accumulation of heat in the heating system and allow heating or preheating of HSW (Hot Service Water) in an inner stainless tank. Incorporation of a storage tank in the heating system with a solid fuel boiler allows an ideal run of a boiler at favourable temperature during the boiler operation. The main benefit lies in the period of optimum operation (i.e. with maximum efficiency) when the excessive unconsumed heat accumulates in the storage tank. The storage tanks are manufactured in 800 and 1000-litre volumes. The tanks and tubular exchangers are made of steel, without the inner surface treatment, the outer surface of the tank is provided with a protective paint. Individual versions are equipped with a tubular exchanger and a buried stainless exchanger of 32 litre volume, and two funnels G1½ with the possibility to install an electric heating element of TJ 6/4 series. The storage tanks are equipped with a removable 80 mm thick insulation and a lock. The NADO type enables direct heating of HSW (Hot Service Water) in a stainless exchanger, or its preheating for another water heater. Connection to a boiler usually allows direct HSW heating in the inner tank to the desired temperature whilst, on the contrary, connection to solar collectors or heat pump only preheats HSW and another, e.g. electric, heater has to be used, in order to complete heating the water to the desired temperature, or final electric heating has to be fitted in the storage tank which is enabled by the electric heating unit of TJ 6/4 series. 1.2 DESIGNING THE SIZE AND CONNECTION OF STORAGE TANK TO THE HEATING SYSTEM An ideal size of the storage tank is designed by a design engineer, or a person sufficiently qualified to design heating systems. Product assembly must be implemented by an authorised person (confirmed in the warranty certificate). Notice: When putting into operation, water has to be filled first into the inner stainless HSW exchanger and the operating pressure inside it has to be kept, only then heating water can be filled into the outer storage tank, otherwise the product might get damaged! - 4 -

2 TECHNICAL PARAMETERS NADO 800/35v9 NADO 1000/35v9 STORAGE TANK CAPACITY [l] 820 999 CAPACITY OF STAINLESS EXCHANGER [l] 32 32 CAPACITY OF BOTTOM EXCHANGER [l] 25 25 CAPACITY OF UPPER EXCHANGER [l] 18 25 WEIGHT [kg] 224 275 HEATING SURFACE OF STAINLESS EXCHANGER [m2] 8.5 8.5 HEATING SURFACE OF BOTTOM EXCHANGER [m2] 3.3 3.3 HEATING SURFACE OF UPPER EXCHANGER [m2] 2.2 3.3 MAXIMUM TANK PRESSURE [MPa] 0.3 0.3 MAXIMUM PRESSURE OF STAINLESS EXCHANGER [MPa] 0.6 0.6 MAXIMUM PRESSURE OF BOTTOM AND UPPER EXCHANGER [MPa] 1 1 MAXIMUM TEMPERATURE OF WATER IN THE TANK [ C] 90 90 MAXIMUM TEMPERATURE OF WATER IN THE EXCHANGER [ C] MAXIMUM WORKING TEMPERATURE IN THE HEAT EXCHANGER [ C] AMOUNT OF 40 C HOT WATER AT 53 C WATER TEMPERATURE IN THE TANK AND INLET WATER 15 C / HOT WATER FLOW [l/(l/min)] AMOUNT OF 40 C HOT WATER AT 80 C WATER TEMPERATURE IN THE TANK AND INLET WATER 15 C / HOT WATER FLOW [l/(l/min)] MAXIMUM OUTPUT OF EL. HEATING ELEMENT OF TJ 6/4" SERIES [kw] 90 90 110 110 *620 / 10 *750 / 10 *1287 / 10 *1450 / 10 2 x 6 2 x 6 STANDING LOSS [W] 118 138 * value stated by calculation Table 1-5 -

3 IMPORTANT WARNING Connection of internal tank for hot water must comply with CSN 060830, i.e. on cold water inlet is necessary to install a safety valve. We recommend to start up the heating circle before commissioning and to clean possible dirts caught in the filter and after this the system would be fully functional. Recommended operating pressure of hot water circle is 0.4 MPa. We recommend installing return valve and an expansion vessel (min. 4 % of hot water in pipeline) on hot water outlet to eliminate back pressure impacts. The reservoir is possible to use only in compliance with conditions stated on performance plate and with instructions for wiring. It is also necessary to observe terms for connection stipulated by some local electrical and water companies as same as manual for assembling and operation besides statutory accepted national regulations and standards. Shut down the reservoir cold water intake if you are not using the reservoir for longer than 24 hours or if the object with the heater is without presence of any person. - 6 -

4 TECHNICAL DESCRIPTION Figure 1 1. Bleeding (heating water outlet) - G1" 2. Hot service water outlet - G 1 ¼" 3. Steel receptacle 4. Exchanger for connecting an additional heating source 5. Funnel for additional heating element TJ 6/4 - G 1 ½" (2 units) 6. Buried stainless exchanger for service water heating by flow 7. Exchanger for connecting solar collectors (heat pump) 8. Cold water inlet - G 1 ¼" 9. Inlet into exchanger - G 1" 10. Funnel for connecting an additional heating water source - G 1 ½" (3 units) 11. Outlet from exchanger - G 1" 12. Entry to (solar) exchanger - G1" 13. Funnel for a thermowell - G ½" (6 units) 14. Stratification pipe 15. Outlet from exchanger (solar) - G 1" 16. Water inlet for connection of return water of heating system - G 1½" (TJ 6/4" mustn't be installed) - 7 -

NADO 800/35v9, NADO 1000/35v9 Figure 2 1" outer 1/4" outer 1 1/2" inner 1/2" inner for TJ 6/4" inner NADO 800/35v9 NADO 1000/35v9 D 790 790 L 1945 2245 Lk 1985 2280 A 156 156 B 879 952 C 1019 1109 E 1392 1552 F 259 529 G 1599 1889 H 1815 2115 I 289 259 J 949 1029 K 1115 1194 M 1552 1854 N 487 497 O 572 842 P - 1209 R 1192 1332 S 1292 1502 T 1292 1452 U 1019 1132 Table 2-8 -

Thermal insulation: NEODUL LB PP Polyester sheet of 80 mm thickness. It consists of an upper cover, flange cover and hole caps. Insulation is supplied in a separate packaging. We recommend that the insulation was fitted at room temperature. At temperatures significantly below 20 C the insulation shrinks. This disables its easy fitting. Figure 3 5 DISPOSAL OF PACKAGING MATERIAL AND NON-FUNCTIONING PRODUCT A service fee for providing return and recovery of packaging material has been paid for the packaging in which the product was delivered. The service fee was paid pursuant to Act No 477/2001 Coll., as amended, at EKO-KOM a.s. The client number of the company is F06020274. Take the water tank packages to a waste disposal place determined by the municipality. When the operation terminates, disassemble and transport the discarded and unserviceable heater to a waste recycling centre (collecting yard), or contact the manufacturer. 7-12-2018-9 -