TYPE POS Oil Shield Sump Pump

Similar documents
VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

FEATURES. Other Fed-Flush Arrangements

STANCOR Oil-Minder Simplex & Duplex Pump and Control Systems

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

Elevator Sump Kits and Components

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Elevator Sump Kits and Components

INTRODUCTION 09/'16 SUPSD 06/'15

Electric Submersible Pumps

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Condensate Boiler Feed Water Make-Up

SIMPLEX WEATHERPROOF CONTROL PANELS

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

MODEL E

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

SECTION WASTEWATER PUMPING STATION DESCRIPTION

K4RH(X) Solids-Handling Pumps

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

PO Box 827 Hawley, MN (218) Fax (218)

Barnes Oil Sensor Switch

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Reliable Long-Term Solutions For Your Toughest Pump

SECTION STEAM CONDENSATE PUMPS

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION STEAM CONDENSATE PUMPS

INSTALLATION AND SERVICE MANUAL WHR5H, 10H, 15H, 20H Series Submersible Sewage Pumps

SECTION STEAM CONDENSATE PUMPS

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Unilift KP, AP, SU/SV, SE & EF

FLANGE-MOUNT CENTRIFUGAL PUMPS

DUPLEX CONDENSATE TANK SYSTEM

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

Progressive Cavity Sewer Systems

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

Selection V 1 INTRODUCTION PAGE V-2 V 2 SUMP/WELL PUMP SELECTION GUIDE PAGE V-3 V 3 CAN PUMP SELECTION GUIDE PAGE V-4

CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT

ULTRA-SAFE Explosion-proof Duct Heaters

Choosing the Right Pump

Direct Gas-Fired Make-Up Air

JCseries EVAPORATIVE CONDENSER. engineering data

Indirect Gas-Fired Make-Up Air

Flygt centrifugal grinder pumps

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

1.0 CONDITIONS FOR CHILLED WATER SUPPLY (PRIMARY SIDE BY DHCS SUPPLIER)

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

brands you trust. The Next Generation of SH Series Pumps BARNES SH SERIES PUMPS

SECTION HEATING BOILER FEEDWATER EQUIPMENT

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

SECTION SANITARY SEWAGE PUMP STATIONS

mini-compacta Type Series Booklet

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

RQE Series Temperature Controllers

For New or Replacement Sewage Pumps

SECTION AIR DOORS

We ve Got Panels Under Control.

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

product brochure Sump, Effluent and Sewage Controls

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ULTRA-SAFE Explosion-proof Duct Heaters

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers

Tubular Industrial Process

LIFT STATION INSPECTION & ASSESSMENT

Plumbing Supply Products

CP1-C5 COMPACTOR SPECS 2009

Submersible Grinder Pump Type ABS Piranha S10 - PE125

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Modular Supply Make-Up Air Unit

Professional Plumbing brands you trust.

MyFAST 16.0 Plus. Layout. Influent See note 4

NEWS 2017 SANIFLO. Pumps and pumping stations

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

Installation, Operation & Service Manual

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION COOLING TOWERS

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

Specifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.

Transcription:

Type POS Oil Shield Provides protection for the environment by preventing oil products from entering sewer systems, environmentally Sensitive River and waterways, while protecting equipment and areas from flooding Applications Elevator Pit Basement Sumps Electromechanical equipment rooms and vaults Manufacturing and processing facilities Optional Equipment: Duplex arrangements Check and shut off valves Fiberglass and steel basins Basin Covers Packaged Systems Standard Features: 1.5 Stainless steel submersible pump in ½ or ¾ HP motor with 10 feet of submersible motor power cable. 115/208-230V ( 1 Phase) or 208-230/460V (3 Phase) Submersible float switch for pump on/off operation. Submersible float switch for high water alarm Stainless Steel Electrode Sensor NEMA 4 weather tight corrosion resistant enclosure with magnetic contactor (3 Phase), alarm, indicating lights for oil detection, high liquid level and power on and contacts for remote indication. Plug in receptacle for easy and economical installation Maximum solid size: 1.5 Note: Not intended for explosion-proof environment! All images and information contained in this booklet are the sole property of The Federal Pumps Corporation, and may not be reproduced without written permission. 1

Pump Performance Data Model HP 115V 208V 230V 460V POS-3/4 3/4 7.9 4.4 4.0 2.0 POS-1 1 10.0 5.5 5.0 2.5 POS-1.5 1.5 12 6.7 6.0 3.0 : Estimates-may vary based upon site conditions Maximum Temperature: 104 degree F. Contact factory for higher temperature requirements! Selection table is provided as a general guideline for expected performance. Refer to performance curve for a more accurate assessment of pump performance. When calculating TDH (total dynamic head) ensure friction losses include pressure loss through pump isolation valves, check valves and piping. Select pipe diameter (if possible) for 7 feet per second velocity to reduce friction losses. All images and information contained in this booklet are the sole property of The Federal Pumps Corporation, and may not be reproduced without written permission. 2

Pump is constructed of stainless steel and designed for sump water service. Ensure temperature of fluid does not exceed 104 degree F. If application requires higher temperature fluid, contact the factory for additional assistance. Performance data is based upon water at 1.0 specific gravity. HP may vary if used in salt water or other environments. Contact the factory or authorized sales representative for additional assistance. Dimensional Data Item Project Name Item Type Tag No In the interest of product development, dimensional data may change. Please consult factory for most updated information. All images and information contained in this booklet are the sole property of The Federal Pumps Corporation, and may not be reproduced without written permission. 3

Type POS-Oil Shield Stainless Steel submersible Pump-10 feet of power cable Submersible On/Off Switch-10 feet of cable High Water Alarm Switch-10 feet of cable Pump mounted stainless steel oil sensor Oil detection alarm light High Level Alarm light Power on light Contacts for remote indication-3 Contacts (ADVISE BMS SYSTEM TYPE!!) NEMA 4X weather resistant and corrosion resistant enclosure. Note: Contractor to attach float switches to discharge pipe for High Water Alarm and (depending on pump size and voltage) pump on/off service. Note: Wiring to/from control panel for 115V service provided by installing contractor. Note: Piping and associated gate and check valves from pump discharge provided by installing contractor. Note: Contractor to advice at time of submission if additional cable (10 feet length is standard) is required. Item Project Name Item Type Tag No All images and information contained in this booklet are the sole property of The Federal Pumps Corporation, and may not be reproduced without written permission. 4

POS-Oil Shield Wiring Diagram All images and information contained in this booklet are the sole property of The Federal Pumps Corporation, and may not be reproduced without written permission. 5

Suggested Specifications Furnish and install as shown in the plans a simplex POS Oil Shield submersible pump as manufactured by Federal Pump Corporation with design flow and discharge head as outlined in the plans. The submersible oil shield sump pump will automatically pump sump water while preventing any oil substances from being discharged into the sewer systems and environmentally sensitive waters. Pump will be constructed of stainless steel and provided with stainless steel shaft and mechanical sealed motor. The pump shall be capable of passing a 1.5 diameter small solid and be provided with 10 feet of submersible motor power cord. Motor shall be rated as shown in the plans. The system will be provided with (2) float switches for mounting on the discharge pipe (by others) and connected to the Oil detection relay panel as described herein. Sequence of operation Upon increase in sump liquid level, the pump on/off float switch will initiate pump operation at the present level and continue pumping operation until it reaches the low level set point. In the event of a high water level condition the high water float switch will activate the high water alarm horn and signal the alarm horn and light. The alarm horn will remain in operation until the silence push button has been activated. In the event of presence of oil, the oil sensing element will terminate pump operation and sound the alarm horn and light alerting the presence of oil in the sump. Control Provide for wall mounting a NEMA 4 oil detection relay panel including a magnetic contactor with thermal overload, oil detection relays with adjustable sensitivity settings, alarm section with alarm horn, silence push button and indication lights for high water level, power on and oil detection as well as contacts for remote indication of alarm functions, thermal strip and plug receptacle. All images and information contained in this booklet are the sole property of The Federal Pumps Corporation, and may not be reproduced without written permission. 6

Sump Steel Graded Cover Option Cover Size: Standard Offering ( 2 X 2 ) 2-0 X 2-0 X 1.5 Thick-Machine Blue Epoxy Paint 1 Cover Supporting Metal Frame Frame installed and set in concrete Cover rests on frame Controls ship loose for wall mounting Check valves and isolation vale not included Non-Traffic Bearing Item Project Name Item Type Tag No All images and information contained in this booklet are the sole property of The Federal Pumps Corporation, and may not be reproduced without written permission. 7