CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Similar documents
Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Modular Supply Make-Up Air Unit

1.1 This section applies to air handling units for HVAC Systems.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

AIR HANDLER DESIGN WORK SHEET

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Direct Fired Heater Model AD Specification

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

FCC Fan-Coil Units High-Performance, Vertical

VERTICAL FAN COIL UNITS

Direct Gas-Fired Make-Up Air

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Advance Release September 2009

62DA,DB,DC,DD,DE,DF07-38

KIC Air Curtains. Technical Guide

FEATURES AND BENEFITS

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

SECTION AIR HANDLING UNIT

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

DCG Commercial. Submittal Data Form

C13-Series Engineering Guide

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

FAS Fresh Air Supply Units

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

XeteX, Inc. All Rights Reserved.

Indirect Gas-Fired Make-Up Air

Modular Heating & Ventilating Unit Model IGX-HV

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Centeral Station Air Handling Unit

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

PRODUCT CATALOG BLOWER COILS.

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Cabinet Unit Heaters Steam / Hot Water

Gas-Fired Indoor and Outdoor Duct Furnaces

SAS Steadyair Make-Up Air Units Technical Guide

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

AIR HANDLING UNITS. Revision AG 16-07

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Water-Cooled Self-Contained Units

Contents INDEX. TDM Series Indirect Fired Heaters

VertiCool Aurora Engineering Guide

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

MLR SERIES MODULAR AIR HANDLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

technical guide Water-Cooled Self-Contained Units

MACH N-407 Heat Pump Air-Cooled Chiller

High Heat COP. High/Low Stage

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Product Specifications. Vertical Floor Consoles By First Co.

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

catalog CDV Fan-Coil Units High-Performance, Vertical

JCseries EVAPORATIVE CONDENSER. engineering data

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

TYPICAL CPA SPECIFICATIONS

SKYPAK II, 3 Ton Series, gives you a

Q-TEC QC-Series Chilled Water Air Conditioner

Technical Assignment 3 11/15/04. Executive Summary

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

SKYPAK II, 3 Ton Series, gives you a

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SeasonMaker ThinLine Fan-coil Units

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

YAH SERIES FAN COIL UNITS

VariCool VAV Engineering Guide

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Transcription:

7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor compartment, all the elements required to treat or condition mixtures of outside and return air as specified to meet building requirements. FEATURES Coil, Blower, Silencer, Humidifier, De-humidifier and Filter sections are assembled as required in the chamber. Controls and electrical wiring are interconnected at the factory to central control panels. Full and easy access to all sections is provided by a full length corridor with access to each section (optional). The Penthouse unit is designed to simplify both installation and maintenance. Capacities range from 1000 CFM to 60,000 CFM or more, and from 3000 BTUH (Cooling / Heating) to 2,000,000 BTUH or more. Note: The following represents components of a typical Penthouse Unit. It is an integral part of Rosemex philosophy to offer particular design criterias meeting the needs of its clients. DESIGN FLEXIBILITY EXAMPLE 20 16 19 17 18 21 14 15 CORRIDOR 12 6 11 7 8 PLAN VIEW 9 13 22 10 10 SILENCER #1 SILENCER #2 10 SUPPLY 5 1 3 4 2 RETURN 7 ELEVATION VIEW

3 GUIDE SPECIFICATIONS (EXAMPLE) ROOF MOUNTING UNIT (PACKAGE-TYPE), S/R 2180 CFM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 SUPPLY FAN: Centrifugal type blower, 13 backward inclined air foil blades, class 1, BHD. Air flow = 2180 CFM; T.S.P. = 4.5 WG; BHP = 2.87; RPM = 2582; 5HP motor O.D.P. 575/3/60-184T (1800 rpm). Fan/motor assembly are internally isolated in the cabinet with vibration isolators (95% efficiency open spring type with 1 minimum static deflection) and a flexible discharge. Fan starter (5HP) pre-wired and mounted in corridor, is supplied with the unit. RETURN FAN: Centrifugal type blower, 13 backward inclined air foil blades, class 1, UBD, capacity of 2000 CFM. T.S.P. = 1.5 WG; BHP = 0.74; RPM = 1551; 2HP motor O.D.P. 145T, 575/3/60. Isolators and starter, same as supply fan above. COOLING COIL: Coil(s) constructed of copper tube (0.625 O.D.), aluminum fins, steel headers with galvanized steel frame. 2 N.P.T. connections for supply and return. Coil tested at 200 psig. Coil drain connected to funnel drain. DATA: 6 rows, 6 FPI; size = (1) 30 h. x 42 w.; circuit factor = full; TH = 228.2 MBH; SH = 127.6 MBH; EAT = 90 F DB / 75 F WB; LAT = 55 F DB / 54.5 F WB; water temperature (entering/leaving) = 42 F / 51 F; water flow = 50.6 USGMP; water pressure drop = 5.5 feet. HEATING COIL: - LAMILINE TYPE (LLS-H): Coil(s) constructed of red brass tube (.625 O.D.), aluminum fins, steel headers with galvanized steel frame, damper blades are extruded aluminum type. 2 N.P.T. connections for supply and return. Coil tested at 200 psig. DATA: 1 row, 12 FPI; size = 27 h. x 42 w.; SH = 244 MBH; entering air (DB) = -10 F; LAT (DB) = 93 F; supply steam pressure = 5 psig. MAIN FILTERS: RIGA-FLO 200 (95% efficiency), 24 x 24 x 12 thick, supported by slide tracks for corridor side access. Complete with DWYER series 2000 filter gauge (0-2 ). PRE-FILTERS: FARR 30/30 (2 thick) (30% efficiency). (1) 20 x 20 - (1) 20 x 25 - (1) 15 x 20 and (1) 16 x 25. Complete with side tracks for corridor side access. SILENCERS: 8 thick aerodynamic modules for supply and return fans. HUMIDIFIER: Type: STEAM. Capacity of 149 PPH; supply steam = 5 psi. Complete with 2 manifolds, adaptors and temperature switch. DAMPERS: Opposed blades, low-leak type, corrosion resistant linkage, extruded aluminum frame and damper blades. LOUVERS: Extruded aluminum storm-proof louvers, for inlet and exhaust air. DIFFUSER PLATE: Perforated plate type at discharge of supply fan section for even air distribution. IN-TAKE HOOD: 45 degree plenum hood covering inlet louvers. Wire mesh (WCG 16 gauge) on inlet of intake hood. MARINE LIGHT: Vapour-proof C.S.A. approved light complete with glass globe, wire-guard and 100 watt lamp pre-wired to lighting switch. UNIT HEATER: Electric-type, ceiling mounted, capacity of 3 kw, 575/1/60, c/w thermostat and discharge louvers. LIGHTING SWITCHES: All switches are 15 amps., 120 volts, c/w pilot light and pre-wired. ELECTRICAL JUNCTION BOX: For power supply 575V and 125V. FUNNEL DRAIN: Silicone gasketed and bolted to corridor floor. STARTERS: For supply and returns fans. Manufactured by SQUARE D, c/w relays and fuses. ELECTRICAL INLET POWER: Plugs for 120V/1/60Hz. ENTRANCE DOOR: Double wall 30 x 72. ACCESS PANELS: Gasketed, insulated for coil removal. GENERAL CONSTRUCTION: The entire outside casing of the unit, except the floor, is double-wall insulated construction, consisting of 16 gauge (WCG) outside panel and 2 thick fibre-glass insulation sandwiched between the outside and inside (22 gauge galvanized steel) panels. The bottom panel of the exhaust air plenum (Item 22) is perforated sheet metal. All access doors are hinged-type. All joints are water-proof. All casing panels are coated with a polyurethane finish. A steel base under entire length of unit is supplied with the curb and flashing. Drains in condensate pans and floor drain will be supplied where necessary.

4 1 FAN 2 LAMILINE FACE & BY-PASS COIL 3 HEATING & COOLING COIL CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

5 4 LOUVER 5 DAMPER 6 SILENCER 7 FILTERS SILENCER #1 SILENCER #2 4 SUPPLY 7 6 1 3 2 5 1 RETURN 6 4

6 UNIT CONSTRUCTION DESCRIPTION OPTIONS OUTSIDE WALLS ALUMINUM (0.064)... PAINTED G 90 GALVANIZED STEEL (0.063)... PAINTED WIPED COATED GALVANIZED STEEL (0.063)... STAINLESS STEEL (0.063)... CASING 2 THICK DOUBLE WALL INSIDE WALLS INSULATION ACCESS DOORS DOUBLE WALL ALUMINUM (0.040)... GALVANIZED STEEL (0.040)... STAINLESS STEEL (0.037)... 2" FIBERGLASS (3 #/cu Ft.)... 4" FIBERGLASS (3 #/cu Ft.)... 18, 24, 30 x 24 TO 60... DOUBLE... MARINE LIGHT FLOOR PLATE FACTORY WIRED WITH SWITCH... FACTORY WIRED WITH SWITCH & PILOT LIGHT... CHECKER PLATE STEEL (0.105)... ALUMINUM (0.125)... STAINLESS STEEL (0.109)... UNIT FLOOR INSULATION 2 FIBERGLASS... 4 FIBERGLASS... ROOF CURB GALVANIZED (0.079) INCLUDING 2 x 4... WOOD NAILER AND GASKETING STRIP... ELECTRONIC JUNCTION BOX FOR POWER SUPPLY... CONTROL CONNECTIONS... CONTROLS PNEUMATIC DAMPER OPERATOR... VARIMARK ll OPERATOR... INLET VANES OPERATOR...

7 UNIT COMPONENTS COMPONENTS DESCRIPTION FANS FOR LOW MEDIUM & HIGH STATIC PRESSURES VARIABLE AIR VOLUME COILS FOR HEATING, COOLING & PREHEATING Fl LTER SECTIONS AIR WASHERS HUMIDIFIER OPPOSED BLADES DAMPER LOUVERS SlLENCERS TYPE FC : FORWARD CURVED... Bl : BACKWARD INCLINED DOUBLE WIDTH... AF : AIR FOIL DOUBLE WIDTH... AFPF : AIR FOIL PLENUM FAN... VARIMARK ll AIR VOLUME CONTROL DEVICE (AF, Bl, AFPF)... VARIMARK I (FC only)... VARIABLE SPEED MOTOR... VARIABLE INLET VANES... WC : CHILLED WATER... RC : DIRECT EXPENSION... WH : HOT WATER... S : STEAM... NFS : NON-FREEZE STEAM... LLW : LAMILINE HOT WATER FACE & BYPASS... LLS : LAMILINE STEAM FACE & BYPASS... ELECTRIC HEATING... LOW CAPACITY FLAT FILTER... MEDIUM CAPACITY ANGLE BANK FILTER... HIGH EFFICIENCY, HIGH CAPACITY BAG FILTER... AUTOMATIC ROLL FILTER... SPRAYED COIL... SPRAY CHAMBER... WETPAD EVAPORATIVE COOLER... STEAM TYPE... HOODED WATER SPRAY (TARGET) TYPE... LOW-LEAK TAMCO 1000... LOW-LEAK INSULATED TAMCO 9000... METAL FORMED... ALUMINUM EXTRUDED... 8 THICK AERODYNAMIC MODULES FOR SUPPLY FAN... 8 THICK AERODYNAMIC MODULES FOR RETURN FAN... PRINTED IN CANADA

MARK-H FAB Products 1560, Marie-Victorin blvd Saint-Bruno (Quebec) J3V 6B9 Tel.: (450) 653-1002 Fax: (450) 653-3464 http://www.rosemex.com