Reduced Order WECC Modeling for Frequency Response and Energy Storage Integration

Similar documents
Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Evaluating Peak Load Shifting Abilities and Regulation Service Potential of a Grid Connected Residential Water Heater

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

A Novel Algorithm for Intelligent Home Energy Management System

Demonstration of 2nd Generation Ducted GE "Brillion" Hybrid Water Heater in the PNNL Lab Homes

Demand side management for integration of variable renewables

Real-Time Root Cause Analysis for Complex Technical Systems

Standard hydraulic circuits for small-scale heat pump plant

Drive Power and Torque in Paper Machine Dryers

ECL Comfort 110, application 116

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Induction Billet Heaters with Enthalpy Controlled Zone Heating

1 Air Handling Units In ICE

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Temperature Control of Heat Exchanger Using Fuzzy Logic Controller

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

PowerRouter application guideline

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Synchrophasor Technology in Control Centers Clemson University, SC March 12, 2014 Vikram S. Budhraja

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR COMMERCIAL ICE MACHINES

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

Estimating the Level of Free Riders in the Refrigerator Buy-Back Program

How to Cut Chiller Energy Costs by 30%

Technical description. Atec.

CLIMA I Thermostat ZENNIO

Hot Water Distribution System Losses in a Net-Zero Home

A study of Transient Performance of A Cascade Heat Pump System

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

VARIABLE REFRIGERANT FLOW FOR LODGING

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

B-40/B-41 Modulating Temperature Controller

Battery Performance Alert

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

Optimizing Strategy for Boiler Drum Level Control

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

Technical Note. EHPA Quality Label Model Range Definition Version

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Business Models to Advance Smart Water Heaters

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

APC BC300 Series 40kW 208/450/480V User Guide

Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

TOP R4 Unknown Operating State

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Improving Boiler Stability Through Advanced Regulatory Control

EMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Dedicated Closed Circuit Hydrostatic Fan Drive Control

INDUSTRIAL DEHUMIDIFICATION DRYING OF SOFTWOODS

OVEN INDUSTRIES, INC.

GPPS-2017-Put 4 digit paper number here

Energy Saving Drives for Hot Strip Mills

THERMOSYS 4.3. Getting Started Guide

Interim Report for the Period thru February 15, 2018 Submitted to Department of Business and Professional Regulations Office of Codes and Standards

Monitoring Natural Air Corn Drying A Demonstration Project

Laser Weld Keyhole Dynamics and Control. M. H. Cho, D.F. Farson Welding Engineering Department, The Ohio State University, Columbus, Ohio

14 Drying. I Basic relations and definitions. Oldřich Holeček, Martin Kohout

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Beneficial Electrification: Exploring the Aggregation of Water Heaters

Considerations in the Design of Smoke Management Systems for Atriums

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

Relay Performance Index for a Sustainable Relay Replacement Program

Modeling, Simulation and Optimization of Residential and Commercial Energy Systems

Final Report Polymer Bead Laundry

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Smoke Layer Height and Heat Flow through a Door

1 Descriptions of Function

SOLAR THERMAL HEATING: ALIVE AND WELL

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

Effective Alarm Management for Dynamic and Vessel Control Systems

Performance Neuro-Fuzzy for Power System Fault Location

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Heat Exchanger Earny Type

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

> ENERGY NEED FOR A STANDARDIZED SUPERMARKET: HEATING, COOLING, REFRIGERATION. > Deliverable 8. With the support of : November 2007

RLDS - Remote LEAK DETECTION SYSTEM

Product Offering for 2017

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Modelling Appliance Loads in Multi-Unit Residential Buildings

The Radiators With Brains

Water Tank and Heater

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Best Practices for Condensing Boilers

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Development of a domestic combined heat and power unit based on a Free Piston Stirling Engine and Powered by ENATEC

Field Evaluation of Pre-Commercial Residential Gas Heat Pump Water Heaters

CHAPTER 7 APPLICATION OF 128 POINT FFT PROCESSOR FOR MIMO OFDM SYSTEMS. Table of Contents

Transcription:

Reduced Order WECC Modeling for Frequency Response and Energy Storage Integration Pranathi Bhattacharji, Student Member, IEEE, Ted K. A. Brekken, Senior Member, IEEE School of Electrical Engineering and Computer Science Oregon State University Corvallis, Oregon 97331 Email: brekken@eecs.oregonstate.edu Abstract This paper presents a simple reduced order model of the western grid interconnect (WECC) that includes interconnect inertia, load frequency response, and generation primary frequency response. The model is validated against detailed power flow and transient response studies and recreates the WECC frequency response to a large generator outage to within.1 Hz RMSE, with the same frequency nadir and settling frequency. To properly capture the generation primary response, three classes of generation are used: slow, medium, and fast. The slow group responds with a time constant of 27 seconds, the medium group with a time constant of 19 seconds, and the fast group with a time constant of.5 seconds. The model is used to investigate the usage of domestic water heaters to assist in primary frequency response and reduce the impact of sudden load or generation changes. It is shown that even a very small-scale implementation of demand response via domestic hot water heaters about 1 % can improve the frequency nadir by 1 %, from 59.666 Hz to 59.697 Hz. The settling frequency is improved from 68 Hz to 89 Hz. Index Terms Energy storage, frequency response, power system stability. I. INTRODUCTION This paper presents two things: first, a simplified model of the WECC western interconnect that captures inertial response, load frequency response, and three classes of primary response generation; second, the usage of this simplified model to investigate the possible benefit of large-scale energy storage with domestic water heaters to WECC transient stability. Domestic water heaters represent a huge potential form of energy storage, both in terms of energy capacity and power capacity. In this paper, only the time scale that covers primary response is considered. Generally, grid reserve generation can be classified into four timescales [1]. Inertial response: inertial response is not dispatched, but instead is the manifestation of the physical property that rotating mass discharges energy when decelerated, and charges energy when accelerated. Primary control: the response of generators under the control of governors to increase generation when speed (i.e., frequency) decreases and decrease generation when speed increases. This is a closed loop local-level control and the typical response time is on the order of seconds. Primary response typically arrests, but does not correct, deviations in frequency. It is the first active layer of defense for grid stability. Secondary control: the next level of control is secondary control, in which additional generation setpoint operation is adjusted to correct for persistent frequency deviation (i.e., drive the frequency back towards 6 Hz.) Secondary control timescales are typically minutes. Tertiary control: the last level is tertiary control, which is loosely defined as additional dispatcher corrections and scheduling, which typically cover timescales from minutes to hours. This paper describes the development of a reduced-order model of the WECC interconnection and the usage of the reduced-order model to estimate the benefit of domestic water participation in frequency response (i.e., primary control) to assist in grid stability and recovery to large generator outages. First, a simple high-level model of the WECC is developed that can recreate the WECC frequency response to a large generator outage with proper modeling of system inertia, load frequency response, and primary frequency response of generation. This simple model will then be used to estimate the benefit that large-scale water heater energy storage implementation can provide to transient response and system stability. II. WECC BASE CASE OVERVIEW Data for this study comes primarily from the 211 California Independent System Operator frequency response study and the summary paper Emergency Response [2], [3], specifically the winter low-load high-wind case. This base case is for a total WECC load of 91,3 MW, with wind providing 14% of the generation. A loss of two Palo Verde units totaling 2,69 MW is simulated. This causes a transient drop in frequency, as shown in Fig. 1. The frequency nadir is 59.67 Hz at a time of 9.8 seconds after the loss of the Palo Verde units with a settling frequency of 8 Hz. III. WECC REDUCED-ORDER MODEL A simplified reduced-order model of the WECC has been developed. The model is shown in MATLAB/Simulink in Fig. 2. This model includes system inertia, load frequency response, and primary response of three classes of generators: slow, medium, and fast. The basis for modeling generators of different response speeds is the result from the 211 Miller, Shao, and Venkataraman report [2], which showed that primary

Frequency (Hz) 6 Base case freq resp 5 Fig. 1. WECC base case frequency response Symbol Name Value Units M Inertia 15 PU power s/pu freq loadbias Load bias 1.27 PU power/pu freq genbiasfast Fast gen. bias 3.432 PU power/pu freq genbiasmed Medium gen. bias 2.112 PU power/pu freq genbiasslow Slow gen. bias 1.56 PU power/pu freq Tload Load response time const. seconds Tgenf Fast gen. time const..5 seconds Tgenm Med. gen. time const. 19 seconds Tgens Slow gen. time const. 27 seconds Pbase Simulation power base 92 GW Frequency (Hz) 6 5 TABLE I MODEL PARAMETERS Simulated freq resp Base case freq resp Fig. 3. Comparison of the base case frequency response and the reduced-order model. The fit is.1 Hz RMSE. Fig. 2. WECC reduced-order model in MATLAB/Simulink modeling the system inertia, load frequency response, and the primary generation frequency response subdivided into slow, medium, and fast groups. control responsive generators have a wide range of response times, from only seconds to well over a minute to respond to the Palo Verde unit loss. The model parameters were tuned by successive sweeps, until a frequency response fit of.1 Hz RMSE was found. The model parameters are given in Table I. A comparison of the model transient response against the benchmark case is shown in Fig. 3. The responses of the load and the fast, medium, and slow generators are shown in Fig. 4. IV. WATER HEATER MODELING A. Power and Energy Capacity Electric water heaters are a significant energy storage resource. Standard residential electric water heaters are 5 or 6 gallons capacity, with one heating element at the bottom of the tank, and another approximately two-thirds up the tank, as shown in Fig. 5. The hot water outlet is at the top of the tank. The upper element has priority and heats the upper one-third of the tank to the desired temperature, usually around 12 degrees Fahrenheit or 13 degrees Fahrenheit. The lower element can be active when the upper element is off (i.e., the upper onethird of the tank is at the desired temperature) and heats the lower two-thirds of the tank to the desired temperature. Generally the water stays well stratified, and the lower twothirds of the tank can be assumed to hold a temperature below that of the upper one-third of the tank. This structure allows for great opportunities for utilizing electric water heaters as energy storage. The temperature of the lower two-thirds of the tank can be manipulated in an intelligent way without greatly affecting the temperature of the water in the upper one-third of the tank, which is the water withdrawn by the user. Assuming a standard residential electric water heater of 5 gallons capacity, an outlet temperature of 13 degrees Fahrenheit, and an inlet temperature of 6 degrees, the lower two-thirds of the tank requires approximately 5 kwh of energy to heat. Therefore, by controlling the lower two-thirds of the tank temperature to range from the inlet temperature as the lower bound, and the outlet temperature as the upper bound, a potential energy storage capacity of 5 kwh can be utilized. Typically each of the upper and lower elements are rated for 4.5 kw. Under the standard configuration, the upper element

Power (GW) 4.5 4 3.5 3 2.5 2 1.5 1.5 lost generation gen fast gen slow gen medium gen total load base case gen resp Fig. 4. Responses of the load and the fast, medium, and slow generators to the simulated loss of generation. The fastest generator group (green trace) reaches its maximum response around 1 seconds, closely following the frequency of the system. The medium speed and slow speed generator groups (red and brown traces) reach their maximum generation in 4 seconds and 6 seconds after the disturbance, respectively. The total generation (light blue trace) is the sum of these three groups and very closely matches the base case generation response. Hot water outlet P rated P wh,totalcapacity P charge P discharge 1 -P wh,totalcapacity SOC Fig. 6. Visualization of the available aggregate water heater power capacity as a function of aggregate water heater SOC. For a given SOC, the upper green line is the maximum charging power available (positive power), and the red line is the maximum discharging power (negative power) available. When the aggregate SOC is, the lower tanks of all the water heaters are at their lowest temperature, and all are available for charging. When the aggregate SOC is 1, the lower tanks of all the water heaters are at their highest temperature, and all are available for discharging. When the aggregate SOC is.5, it is approximated that half of the water heaters are available for charging, and half are available for discharging. ing), it is not meant they literally push energy on the grid, but instead decrease their load by the amount they are effectively generating, as if some local generation source has come online to decrease the net load. B. Aggregate Water Heater Modeling Cold water inlet Upper thermostat and heating element Lower thermostat and heating element Fig. 5. Water heater diagram. The upper element has priority and heats the upper 1/3 of the tank where the hot water outlet is located. The lower element can operate when the upper element is off, and heats the lower 2/3 of tank where the cold water inlet is located. has priority to heat the upper portion of the tank. If the upper element is off, the lower element is enabled. Therefore, the two elements operate exclusively, and the total water heater power capacity is 4.5 kw. When referring to water heaters generating (i.e., discharg- A single water heater could be modeled very simply as a battery or capacitor. However, we are interested in modeling the aggregate of millions of water heaters. The aggregate system will have a power capacity, and a state of charge. Contrary to a simple single battery or capacitor, the power capacity of the aggregate system will be a function of the state of charge. For example, consider the state of charge of the entire aggregate system to be.5 (i.e., half full). In that case, some of the water heaters will be fully charged, some partly charged, and some fully discharged, such that the total state of charge is.5. However, the water heaters that are fully charged will not be able to contribute to total charging power capacity, and the water heaters that are fully discharge will not be able to contribute to total discharging power capacity. Consider the case of the total system state of charge at.9. In that case there are many water heaters that are fully charged, a few that are partly charged, and very few that are fully discharged. Thus the total charging power capacity will be small, and the total discharging capacity will be large. Therefore for the aggregate system of millions of water heaters, we expect the charging and discharging power capacity to be a function of the total aggregate state of charge. This is illustrated in Fig. 6. We have assumed a linear relationship of power capacity to SOC. Research to refine the relationship is a good topic for future research.

V. WECC TRANSIENT RESPONSE WITH WATER HEATER ENERGY STORAGE The simplified WECC model shown in Fig. 2 has been modified to include the water heater modeling, shown in Fig 7. The goal is to show the benefit to transient response that water heater loads can provide. The water heater power is to be controlled proportional to frequency, thus providing primary frequency response. When the frequency drops below 6 Hz due to the simulated loss of the Palo Verde units (2.69 GW =.29 PU), some of the water heater capacity will respond by decreasing load, thus helping to stabilize the system. This paper does not focus on the exact hardware implementation of the water heater control system, but in practice it could be quite straightforward. For example, simply the bottom element of the water heater could be replaced by an augmented heating element that includes a simple circuit to detect frequency. As the frequency decreases, the effective element resistance and therefore the element power can be effectively changed by pulse width modulating the applied voltage. If the home resident is in need of hot water, the upper element will be on and the lower element is unpowered. If the upper tank is standing by ready with the desired water temperature, the lower element will be available, and thus with a simple augmentation of the thermostat to respond to frequency, will be silently increasing or decreasing the temperature in the lower tank according to frequency. By staying within this traditional water heater control framework, the upper tank and home resident comfort remains the priority. This simple modification would require no additional communication interface; it would effectively utilize frequency to detect the state of the generation-load balance. Under this scheme, the response of any one individual water heater cannot be guaranteed. However, the aggregate water heater behavior of millions of water heaters should be predictable. It is estimated there are approximately 3 to 4 million residential water heaters in the Pacific Northwest [4]. Assuming each water heater to have a power capacity of 4.5 kw, there is a total residential water heater load capacity of approximately 15, MW. In this research, we make a very conservative estimate of 3 % of that resource (5 MW) is available for demand response (i.e., primary frequency participation) for the entire WECC. Assuming each water heater to have a power capacity of 4.5 kw, that is a total of 111, water heaters. Assuming 5 kwh per water heater, there is a total energy storage resource of 555 MWh. Two scenarios are simulated: the aggregate water heater load responding at the standard droop of 5 %, and a more aggressive scenario of the aggregate water heater load responding at a droop of.38 %. For the 5 % droop case which is a standard setting for generation on primary frequency control the generator governor is set to modify the generator power setpoint at a rate of P rated per 3 Hz. For the.38 % case, the generation setpoint is modified at a rate of P rated per.23 Hz. Generally, f P (f) = P setpoint + P rated (1) k Hz For the water heater control P setpoint is simply the current natural water heater load, which is treated as zero in the simulation. (Note that zero load in the simulation does not represent objectively zero Watts, but is instead the bias point of the simulation.) The parameter k Hz is 3 Hz for the 5 % case, and.23 Hz for the.38 % case. A value of.23 Hz was chosen as that is the frequency nadir of the benchmark case. Thus when k Hz is 3 Hz, approximately.23/3 = 7.7 % of the total aggregate water heater capacity will be utilized, whereas when k Hz is.23 Hz, approximately 1 % will be utilized. The aggregate water heater parameters are given in Table II. Symbol Name Value Units PwhTotCap Total aggregate water heater 5 MW power capacity JwhTotCap Total aggregate water heater 555 MWh energy capacity k Hz Water heater freq. response constant {.23, 3.} Hz TABLE II WATER HEATER PARAMETERS The simulation results are shown in Fig. 8 and Fig. 9. The initial aggregate water heater SOC is.5, and therefore 25 MW of the 5 MW is available for charging, and 25 MW available for discharging. The results show that for the standard case of full water response per 3 Hz of frequency deviation, only about 1/5 (5 MW) of the available 25 MW is utilized. However, even with this modest response, there is a small but measurable benefit in the frequency nadir and settling frequency. For the more aggressive case of full water heater response per.23 Hz of frequency deviation, the full water heater capacity of 25 MW is utilized. The benefit is much greater in this case, with the frequency nadir increased from 59.666 Hz to 59.697 Hz over the base case, which is a 1 % improvement in the deviation from 6 Hz. The cases are summarized in Table III. Case Freq nadir Settling freq Base 59.666 Hz 68 Hz k Hz = 3 Hz 59.673 Hz 71 Hz k Hz =.23 Hz 59.697 Hz 89 Hz TABLE III COMPARISON OF FREQ. RESP. WITH WATER HEATERS PARTICIPATING VI. CONCLUSION This paper demonstrates the calibration of a greatly reduced order model of the western interconnect, and the usage of that model to investigate the impact of large-scale integration of domestic hot water heaters for energy storage and frequency response. The simulations suggest that even a very modest penetration of water heaters (approx. 5 MW power capacity and 555 MWH energy capacity), can have a significant impact on reducing the frequency deviation nadir and the settling frequency deviation in response to a large generation outage.

Fig. 7. Simplified WECC model with aggregate water heater modeling. The water heater parameters are given in Table II. The blocks in the upper right model the water heater power limits, which are linear functions of SOC as illustrated in Fig. 6. The commanded water heater power Pwh cmd is the desired water heater power above or below the nominal natural water heater load at that moment. The amount of increase or decrease in the water heater load is dictated by the control variable k Hz, which specifies the amount of commanded water heater power per deviation in frequency. Frequency (Hz) 6 5 no energy storage wtr htrs resp full for 3 Hz dev wtr htrs resp full for.23 Hz dev Fig. 8. Frequency response of the WECC to the Palo Verde outage (2.69 GW of lost generation) under three scenarios: the base case of no water heater energy storage, the standard case of all available water heaters responding for 3 Hz (5 %) deviation, and the aggressive case of all available water heaters responding for a.23 Hz (.38 %) deviation. The frequency nadirs and settling times are summarized in Table III. Power (MW) 1 5-5 -1-15 -2 P waterheater, k Hz = 3 Hz P waterheater, k Hz =.23 Hz -25 Fig. 9. Water heater power in response to the change in frequency due to the loss of 2.69 GW of generation for two cases: all available water heater power responding per 3 Hz frequency deviation, and all available water heater power responding per.23 Hz deviation. For the 3 Hz case, only about 1/5 of the total water heater discharging capacity of 25 MW is utilized, whereas for the more aggressive.23 Hz case, all of the available 25 MW capacity is utilized. With hot water heaters responding at the standard of generation rated capacity per 3 Hz deviation, there is a small but measurable reduction in the 6 Hz deviation nadir, from 59.666 Hz to 59.673 Hz. If the water heaters are set to respond much more aggressively: full rated capacity per.23 Hz deviation, the water heaters can contribute their full 25 MW capacity (assuming 5 % SOC) and the frequency nadir improved from 59.666 Hz to 96.697 Hz, which is a 1 % improvement in the deviation from 6 Hz. We conclude that domestic hot heaters represent a very large, fast, and flexible resource that should be able to be utilized with a much lower implementation cost than new energy storage. REFERENCES [1] Balancing and frequency control, North American Electric Reliability Corporation (NERC), Tech. Rep., January 211. [2] N. Miller, M. Shao, and S. Venkataraman, California ISO (CAISO) frequency response study, General Electric Consulting, Tech. Rep., 211. [3] N. Miller, C. Loutan, M. Shao, and K. Clark, Emergency response, IEEE Power and Energy Magazine, November-December 213. [4] Sixth northwest conservation and electric power plan, Northwest Power and Conservation Council (NPCC), Tech. Rep., February 21.