Technical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10.

Similar documents
Technical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

TEST REPORT No. EN-2160/057/15-098/15

Supplementary type approval testing of Selco modules

This document is a preview generated by EVS

DELTA Classification Report

Test Report Nº B2016 LACUS IN 24

TNO report MON-RPT-033-DTS

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

ISO INTERNATIONAL STANDARD. Small craft Airborne sound emitted by powered recreational craft Part 1: Pass-by measurement procedures

ISO INTERNATIONAL STANDARD

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

Determination of air borne sound insulation According to ISO 140-3

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

Hemi Anechoic Chamber Number:

Consumer vacuum breast-pumps

INTERNATIONAL STANDARD

AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS OF APPROVAL AND RECIPROCAL RECOGNITION OF APPROVAL FOR MOTOR VEHICLE EQUIPMENT AND PARTS

Gern Glas Order no. 0302/ Industrivej 4 Page 1 of Sorring Appendicis 1 Danmark Initials MJLD/MFRI

REPORT SUNDBYBERG KOMMUNHUS, MEASUREMENT OF SOUND PRESSURE LEVELS IN OPEN PLANE OFFICES STORKONOTOR

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

INTERNATIONAL STANDARD

ISO 6393 INTERNATIONAL STANDARD. Earth-moving machinery Determination of sound power level Stationary test conditions

Bruksanvisning Directions for use

Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment

According to the following European Regulations which come into force:

PCT Workshop Before you leave the office

Measuring Sound Pressure Level with APx

ISO INTERNATIONAL STANDARD

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Acoustics in open-plan offices A laboratory study

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Draft COMMUNICATION FROM THE COMMISSION

Avicii 2014 Centennial Parklands, Sydney 25 th January 2014

CASE STUDY. History. Testing Laboratories. GHSP Testing Laboratories A2LA Accredited Testing Laboratory. United States of America

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

Report Number BTC 15450A

CONDOR. Supply air ceiling QUICK FACTS

next DX.U.S* 052.Z2.H6.DC

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

Handbook Qualification Quiet Room label

CNBOP-PIB Standard Fire Protection

SOUTH AFRICAN NATIONAL STANDARD

Ceiling air diffuser INDULTHERM INDULTHERM-e

Installation, operation and maintenance guide for window models

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Room Acoustics, PA Systems and Speech Intelligibility for Voice Alarm Systems using the example of the Cruise Center Steinwerder

European Technical Assessment ETA 17/1007 of 02/05/2018

Type approval testing of miscellaneous smoke and heat detectors for marine applications

SPECIFICATIONS FOR THE NF ELECTRICITE PEFORMANCE MARK N LCIE / C AUTONOMOUS STORAGE WATER HEATER WITH ELECTRICALLY DRIVEN COMPRESSOR

o Rear HVAC columns (Priority 1: Item 3) the rear ceiling area: be more dead for the organ and traditional music. (Priority 2: Item A)

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

Sound Performance Rating of Non-ducted Indoor Airconditioning

PRODUCT CONFORMITY CERTIFICATE

Sound Performance Rating of Outdoor Unitary Equipment

Heat Recovery Unit HERU. web-version

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

Vibration tests on a TNAML Luminaire


Acoustic Verification Report

COTES ALL-ROUND THE C105 RANGE

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

ROOFMASTER STEF-HT ROOF FAN

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

EEDEN technical data ERHQ AA

Sound absorption coefficient Equivalent sound absorption area Sound absorption coefficient Sound absorption class

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

PRODUCT CONFORMITY CERTIFICATE

(Non-legislative acts) REGULATIONS

B COMMISSION REGULATION (EU)

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Do you want a versatile solution

Ceiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL

This document is a preview generated by EVS

CERTIFICATE of Product Conformity (QAL1 )

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

Specimen delivery date: Test date: Sampling: The test specimen sampled by customer. Order description N o 152/

Loudspeaker Test. Report

ISO 7779 INTERNATIONAL STANDARD. Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ACOUSTICAL DESIGN OF THE CONCERT HALL OF PÉCS CONFERENCE AND CONCERT CENTRE

TEST REPORT: CHM14-05-CHY

Lawnmowers, pedestrian controlled (combustion engine powered)

draft dated 9/17/2015 page 1

ISO INTERNATIONAL STANDARD

Listen Out 2016 Centennial Parklands, Sydney 1 st October 2016

Remote Monitoring of Offshore Structures using Acoustic Emission.

CALIBRATION HOW IT WORKS

RLDS - Remote LEAK DETECTION SYSTEM

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Queen St E & Leslie St Noise Analysis Toronto, Ontario. Toronto Transit Commission Streetcar Department 1900 Yonge Street Toronto, ON M4S 1Z2

Innovations in the Field of Noise and Vibrations by Spectri Ltd.

Transcription:

Technical Note Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6 Performed for COTES A/S TC-100902 Project no.: T211658 Page 1 of 10 15 January 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax +45 72 19 40 01 www.delta.dk VAT No. 12275110 The report must not be reproduced, except in full, without the written approval of DELTA.

Page 2 of 10 Title Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6 Journal no. Project no. Our ref. TC-100902 T211658 MAB/JEL/CB/ilk Client COTES A/S Ndr. Ringgade 70c 4200 Slagelse Denmark Client ref. Thomas Rønnow Olesen Laboratory DELTA Agro Food Park 13 8200 Aarhus N Denmark Test conditions DS/EN ISO 11202:2010 DS/EN ISO 3744:2010 Results The dehumidifier type C35E-3.3 and type C35E-5.6 have been tested on 15 October 2015 and the sound pressure level was measured 1 metre from the dehumidifier in four positions. The maximum A-weighted sound pressure level, L pa at 1 metre distance was measured in position D (right side) at nominal flow mode: Minimum effect: Maximum effect: 53.5 db re 20 µpa 60.5 db re 20 µpa Standard deviation is σ tot = 1.6 db. Remarks The results apply only to the object tested. Results are rounded to the nearest 0.5 db. DELTA, 15 January 2016 Jens Elgaard Laursen Senior Specialist, Acoustics

Page 3 of 10 Contents 1. Introduction... 4 2. Test Object... 4 2.1 Operating Conditions during Test... 4 3. Acoustic Environment... 5 4. Measurement Methods... 5 5. Sound Pressure Measurements and Corrections... 5 6. Test Results... 6 6.1 Sound Pressure Levels... 6 Annex 1 Measurement Points... 8 Annex 2 Instrumentation... 9 Annex 3 Sound Power Levels for Reference Sound Source B&K 4204... 10

Page 4 of 10 1. Introduction On behalf of COTES A/S, DELTA has performed sound measurements on a dehumidifier type C35E-3.3 and C35E-5.6. The noise measurements were performed according to DS/EN ISO 11202:2010. 2. Test Object Type C35E-3.3 C35E-5.6 Make COTES A/S COTES A/S Serial No. 14-12269 14-12269 Process Flow 750 m 3 /h 1000 m 3 /h Reg. Flow 135 m 3 /h 233 m 3 /h Power 5.1 kw 8.8 kw Dimensions (both) L 532 mm / W 756 mm / H 1090 mm Figure 1 Test set-up for the dehumidifier C35E-3.3 and C35E-5.6. The front here is Position A (see Annex 1). 2.1 Operating Conditions during Test The dehumidifier was tested at nominal flow mode. The noise emission was steady for the specified operating mode.

Page 5 of 10 3. Acoustic Environment The dehumidifier was placed indoor in a large workshop room at COTES, Rudolfgårdsvej 1A, 8260 Viby, Denmark (see Figure 1). On the ceiling of the workshop were mounted acoustic absorbing panels. The main dimensions of the room are 13.5 m 8 m 2.8 m (length width height). The acoustic quality of the test room was measured with a reference sound source from Brüel & Kjær type 4204. The measurements were performed by Jens Elgaard Laursen, DELTA Acoustics, on 9 December 2015 and were performed according to ISO 3744 in order to calculate the test rooms environmental correction factor K 2A. The largest value was found to be K 2A (50 ) = 5.2 db in position B (left side of the test object). The K 2A values were all lower than 7 db, and the test room therefore qualifies for sound pressure measurements according to DS/EN ISO 11202. The sound power level values of the reference sound source are enclosed in Annex 3. 4. Measurement Methods The measurements were performed according to standard DS/EN ISO 11202. The sound pressure level was measured in a number of positions on a virtual measuring surface at 1 metre distance from the test object as illustrated in Annex 1. A photo of the measuring set-up is shown in Figure 1. The measurements of the test object were performed on 15 October 2015 by Marina Brandt, DELTA Acoustics. The used instruments are listed in Annex 2. All measurements were performed with the test object in nominal flow mode. 5. Sound Pressure Measurements and Corrections In each of the measurement positions the sound pressure level was measured for minimum 60 seconds. The background noise in the test room was measured while the dehumidifier was turned off. The measured time-averaged sound pressure levels L pa are corrected for each microphone position according to the following formula: L pa = L pa) - K 1A - K 3A. Where L pa is the energy A-weighted sound pressure level on the measuring surface, corrected for K 1A and K 3A. K 1A is the A-weighted correction for background noise level K 3A is an environmental correction depending of reflecting surroundings.

Page 6 of 10 The measurements were calculated and corrected in one-third octave frequency bands 50-10.000 before summing up. According to Annex A in DS/EN ISO 11202, the local environmental correction K 3A is dependent of the absorption area of the room surfaces: K 3A = 10 log (1 + 4S/A), where S is the area of a hemisphere with a radius of 1 metre: S = 2 π r 2 = 6.28 m 2. A is the total absorption area of the room: A = α S V, where α = 0.3 is an estimate of the mean absorption coefficient of the room surfaces. S V is the total area of the test room (walls, ceiling and floor), S V = 336 m 2. 6. Test Results 6.1 Sound Pressure Levels In Table 1 the measurement results are shown as the A-weighted sound pressure level in each of the four microphone positions: A-D (see illustration in Annex 1). C35E-3.3 and C35E-5.6 Sound pressure levels, L pa in db re 20 µpa Measurement position: A B C D Mean value C35E-3.3 Nominal flow mode 50.8 53.7 50.3 51.7 51.8 C35E-5.6 Nominal flow mode 57.7 60.7 56.7 56.7 58.3 Table 1 Type C35E-3.3 and C35E-5.6. Measured and corrected, averaged, A-weighted sound pressure levels L, pa in db re 20 µpa corrected for background noise (K 1A ) and the environment correction (K 3A ). The highest value was found in position B on the left side of both of the two test object: Type C35E-3.3: Type C35E-5.6: 53.7 db(a) 60.7 db(a) The background noise 26.2 db(a) was measured in one position (Position D). The standard deviation of the measurements is σ R0 = 1.5 db (accuracy grade 2). The operating and mounting conditions are σ omc = 0.5 db and the total standard deviation is σ tot = 1.6 db.

Page 7 of 10 The corrected, averaged (four positions), A-weighted sound pressure levels per 1/1-octave frequency band are shown in Table 2. Type 63 125 250 500 1000 2000 4000 8000 SUM C35E-3.3 26.7 34.2 46.6 46.2 44.3 44.4 38.0 27.4 51.8 C35E-5.6 32.9 41.6 53.9 51.9 50.6 50.6 44.6 35.1 58.3 Table 2 C35E-3.3 and C35E-5.6. Corrected, averaged, A-weighted sound pressure levels per 1/1- octave frequency band in db re 20 µpa.

Page 8 of 10 Annex 1 Measurement Points The dashed lines show the measurement surface located at d = 1 metre from the reference box containing the test object. Four microphone positions were placed at height 1.5 m above the floor. B A C D Set-up for the sound pressure measurements (not in scale).

Page 9 of 10 Annex 2 Instrumentation Instruments used for the sound measurements on 15 October 2015: No. Equipment Make Type Last Calibration Next 02L023 Sound Level Calibrator Brüel & Kjær 4231 11-08-2015 11-02-2016 08L034 Sound Level Analyzer Brüel & Kjær 2250 19-01-2015 19-01-2017 06L058 ½ Microphone G.R.A.S. 40AE 16-01-2015 16-01-2016 Instruments and analysis software used for the sound measurements on 9 December 2015: No. Equipment Make Type Last Calibration Next 1190 L Sound Level Calibrator Brüel & Kjær 4231 29.07.2015 29-01-2016 1370 L Hard Disc Recorder Sound Device 744 11-08-2015 12-08-2017 4181 L ½ Microphone Brüel & Kjær 4188 02-07-2015 02-07-2016 4182 L ½ Microphone Brüel & Kjær 4188 02-07-2015 02-07-2016 0131 T Reference Sound Source Brüel & Kjær 4204 19-11-2011-1505 L Hygrometer QEO fennel FHT 70 21-03-2014 - - Multimeter Fluke 77 - - - Noise Analyzer noiselab 4.0 Capture - - - Noise Analyzer noiselab 4.0 Batch - - The measurement set-up was calibrated before and after the measurements. All instruments are calibrated regularly in accordance with our DANAK guidelines.

Page 10 of 10 Annex 3 Sound Power Levels for Reference Sound Source B&K 4204 Sound power level values from Exova Metech calibration certificate no. 435983. Test room parameters on 9 December 2015: Voltage: 231.3 V. Humidity: 37.7 %. Temperature: 23.7 C.