WWW. W MARINEINVEST. T PL P

Similar documents
FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PWA, 3-phase (D10571)

Trouble Shooting Guide PAA, 1-phase (D3731)

Trouble Shooting Guide FAA, 3-phase (D3631)

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Condensing Unit Installation and Operating Instructions

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

442 Chapter 16. Figure 16-5 Gas leak detection

Contour TM Screw Compressors

Otherwise, you can continue reading the file on the following pages.

Service Step by Step Trouble-Shooting Check-List

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Bulletin , March Electric Hot Gas Bypass Valves

National Maritime Center

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

REFRIGERANT ON-VEHICLE INSPECTION AC 14

Condensing Unit and Refrigeration System Installation & Operations Manual R448A/R449A

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

Energy Use in Refrigeration Systems

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

Reducing Refrigerant Leakage

R4H4. Product Specifications

OWNERS INSTRUCTION MANUAL. 221 South Berry Street P.O. Box 1030 Brea, CA Brea, CA Phone: 714/ * Fax: 714/

N4H4. Product Specifications

Refrigerant Valves/Accessories

Room Air Conditioner Service and Parts Manual

Sporlan Valve Division Parker Hannifan/CIC Group

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

National Maritime Center

REFRIGERANT CHANGEOVER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Preventative Maintenance Tables

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

2-STAGE SEMI-HERMETIC

Natural Refrigerants.

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

49 Danfoss Thermostat Kits Ranco Varifix Kits

CASCADE REFRIGERATION Revised by: Frank Fulkerson, CMS Adapted from materials originally provided By: Charles C. E. Harris

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

R4H4. Product Specifications

MAC N-407 Air-Cooled Chiller

Condensing Unit Installation and Operating Instructions

CHILLER. Operator s & Installation Manual

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

MACH N-407 Heat Pump Air-Cooled Chiller

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Series 1140 and 1141 Temperature Regulators

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

10/4/2013. The Changing State of Refrigerants

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

SECTION AIR COMPRESSORS AND ACCESSORIES

WCH5**4. Product Specifications

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

PDF Created with deskpdf PDF Writer - Trial ::

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

NUMBER: ISSUED: JULY 13, /336 73/23 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI

TROUBLESHOOTING VANGUARD

CHILLER MODEL: CH1500, 2000 AND 3000

Page 1 of Relevant Provincial Jurisdictional legislation.

DESIGN STANDARDS SECTION 15600

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Glass Door Merchandiser. Model RM-45-SD

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Warm Case Troubleshooting Guide 9/18/2014

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Kramersaver Air Cooled Condensing Units

REFRIGERANT RECOVERY SYSTEMS

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

Air-Cooled Condensing Units with Compact Screw Compressors

Glass Door Merchandiser. Model RM-49

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

C0322 and C0522 Service Parts

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Glass Door Merchandiser

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Transcription:

WWW.MARINEINVEST.PL

All Rights Reserved. No part of this publication should be reproduced in any form or otherwise used without written permission from publisher.

General Information Copyright by MARINE INVEST POLAND, Gdańsk 2015

Copyright by MARINE INVEST POLAND, Gdańsk 2015

Copyright by MARINE INVEST POLAND, Gdańsk 2015

Copyright by MARINE INVEST POLAND, Gdańsk 2015

*Mandatory Leak Check to be carried out by a qualified person. Copyright by MARINE INVEST POLAND, Gdańsk 2015

Copyright by MARINE INVEST POLAND, Gdańsk 2015

Copyright by MARINE INVEST POLAND, Gdańsk 2015

Type Name R-Number Formula ODP GWP Toxic or = 0? 100 yr value Flammable CFC Trichlorofluoromethane R-11 CCL3F no 4750 A1 CFC Dichlorodifluoromethane R-12 CCL2F2 no 10900 A1 CFC Chlorotrifluoromethane R-13 CCLF3 no 14400 A1 HCFC Chlorodifluoromethane R-22 CHCLF2 no 1810 A1 HCFC Dichlorofluoroethane R-141b no 725 A1 HFC Difluormethane R-32 CH2F2 yes 675 A2L HFC Pentafluoroethane R-125 C2HF5 yes 3500 A1 HFC Tetrafluoroethane R-134a C2H2F4 yes 1430 A1 HFC Fluoroethane R-161 C2H5F yes 12 A3 HFC R-404A 44%C2HF5 52%C2H3F3 4%C2H2F4 yes 3922 A1 HFC R-407A 20%CH2F2 40%C2HF5 40%C2H2F4 yes 2107 A1 HFC R-407C 23% CH2F2 25%C2HF5 52% C2H2F4 yes 1774 A1 HFC R-407F 30%CH2F2 30% C2HF5 40% C2H2F4 yes 1825 A1 HFC R-410A 50% CH2F2 50% C2H5F yes 2088 A1 HFC Isceon 59 R-417A 46% C2HF5 50% C2H2F4 4% C4H10 yes 2346 A1 HFC Isceon 79 R-422A 85% C2HF5 11% C2H2F4 4% C4H10 yes 3143 A1 HFC Isceon 29 R-422D 65% C2HF5 31% C2H2F4 4% C4H10 yes 2729 A1 HFC R-507(A) 50% C2HF5 50% C2H3F3 yes 3985 A1 HFO R-1234yf C3H2F4 yes 4 A2L HFO R-1234ze C3H2F4 yes 6 A2L HC Methane R-50 CH4 yes 25 A3 HC Propane R-290 C3H8 or CH3CH2CH3 yes 3 A3 HC HCR-188C R-441A 3% C2H6 55% C3H8 42% C4H10 yes 3 A3 HC n-butane R-600 C4H10 or CH3CH2CH2CH3 yes 3 A3 HC iso-butane R-600a C4H10 or CH(CH3)2CH3 yes 3 A3 HC / HO Propylene R-1270 C3H6 yes 3 A3 REMAINING Ammonia R-717 NH3 yes 0 B2L REMAINING Water R-718 H2O yes 0,2 A1 REMAINING Air R-729 Air yes 0 A1 REMAINING Carbon Dioxide R-744 CO2 yes 1 A1 A1 B2L A2L A3 non flammable, toxicity OEL > 400 ppm low flammability and toxicity OEL < 400 ppm lower flammability < 10 cm/s flammable, non toxic CFC = CFK's synthetic chlorinated compound HCFC = HCFK's same, but partly hydrogen, partly chloride HFC = HFK's same, or hydrogen and fluoride, without chloride HFO = also a HFC with (less stable) double bond HC = natural hydrocarbom HC / HO = natural hydrocarbon with double bond Copyright by MARINE INVEST POLAND, Gdańsk 2015

TROUBLE/SYMPTOM PROBABLE CAUSE REMEDY Compressor will not start Power off. Check main switch, fuse and wiring. Thermostat set too high. Reset thermostat. Thermal overload switch open. Reset switch. Oil safety switch open. Reset switch. Dirty contacts. Clean all, control contacts. Loose electrical connections or faulty wiring. Tighten connections, check wiring and rewire. Compressor motor burned out. Check and replace if defective. Liquid line solenoid valve closed. Check for burned-out holding coil. Replace defective. Evaporator fan off. Check fuses, overload. Restart. Compressor cycles intermittently LP-Switch irregular in operation Check for blocked tubing to switch. Check switch setting. Low refrigerant charge Check cause, repair. Charge refrigerant. Capacity control setting Adjust, reset. incorrect. Thermostat differential too Adjust, reset. narrow. Suction valve closed or Open up valve. throttled. Compressor cycles on HP- Tubing to HP-Switch restricted. Check, clean or replace tubing. Switch Faulty HP-Switch. Repair or replace. Refrigerant overcharge. Remove excess refrigerant. Insufficient condenser, water flow or blocked condenser. Adjust water regulating valve to condenser. Clean condenser. Discharge service valve not fully Open valve. open. Air in system. Purge air, call Refrigeration engineer. High discharge pressure Condenser inlet water temperature too high. Insufficient water flow through condenser. Increase water quantity by adjusting water regulating valve. Use colder water. Re-adjust water regulating valve. Increase size of water supply main to condenser. Clean tubes. Plugged or scaled condenser tubes. Discharge valve partially closed. Open valve. Refrigerant overcharge. Remove excess refrigerant. Air in system. Purge air, call refrigeration engineer. Copyright by MARINE INVEST POLAND, Gdańsk 2015

Low discharge pressure Excessive water flow through Adjust water regulating valve. condenser Worn piston rings Replace Suction service valve partially Open valve. closed. Leaky compressor suction valves. Inspect valve discs and valve seats. Replace if worn Flooding Defective or improperly set of expansion valve. Adjust to 5-10K superheat. Valve operation most be stable (no hunting). Low suction pressure Low refrigerant charge. Check cause, repair. Charge refrigerant. Excessive superheat. Adjust expansion valve. Loose or misaligned coupling. Check alignment and tightness. Insufficient clearance between Replace defective parts. piston and valve plates. Motor or compressor bearing Replace bearings. worn. Loose or misaligned belts. Check alignment and tension. (Belt slack should be on top). Loose hold-down bolts. Tighten bolts. Unit foundation improperly Isolate foundation. isolated. Improper support or isolation of piping. Use proper piping connections and support piping with suitable hangers. System noise Slugging from refrigerant feedback. Hydraulic knock from excessive oil in circulation. Defective valve lifter mechanism (noise level varies with unloading). Piping vibration. No muffler in discharge line or improperly located. Hissing (insufficient flow through expansion valve, or blocked liquid line strainer). Check the expansion valve setting. Check thermal bulb looseness and correct location. Remove excess oil. Check expansion valve for flood-back. Replace sticking filter pins. Check un-loader fork for alignment. Check power element for sticking piston. Check for oil leakage at tube connections to power element. Check the amount of valve pin lift above valve seat. Support pipes are required. Check pipe connections. Install muffler. Move muffler closer to compressor. Find cause, charge refrigerant or clean strainer. Copyright by MARINE INVEST POLAND, Gdańsk 2015

Compressor will not unload Capacity control valve not Repair. operating. Un-loader element sticking. Repair. Hydraulic relay sticking. Replace control cover assembly. Plugged pressure line to power Clean line. element. External adjusting stem broken. Replace. Compressor will not load Low oil pressure. Check oil charge, switch settings. Capacity control valve stuck Repair or replace. open. Un-loader element sticking. Repair. Plugged or broken pressure line Clean or repair. to power element. External adjusting stem broken. Replace. Control oil strainer blocked. Clean or replace. Control valve bellows leaking. Remove thread protector and leak test. Replace valve body if bellows leak. Pipe plug in pneumatic Remove pipe plug. connection. Foaming in crankcase from refrigerant flooding. Check expansion valve adjustments and piping. Hydraulic relay sticking. Replace control cover assembly. Rapid un-loader cycling Excessive fluctuation in suction Resize expansion valve. pressure from oversized expansion valve. Partially plugged control oil Clean or replace strainer. strainer. Low oil pressure. See trouble/symptom low oil pressure. Low oil pressure Low oil charge. Charge oil. Faulty oil gauge. Check and replace. Defective oil pressure Repair or replace. regulator. Blocked oil suction strainer or Clean strainer or filter. filter. Broken oil pump tang. Replace pump assembly. Blocked oil line. Remove obstruction. Worn oil pump. Replace pump assembly. Worn compressor bearings. Replace. Cold compressor Liquid carryover from evaporator. Check refrigerant charge and expansion valves. Low crankcase oil level Oil return, check valve, stuck, Repair, replace or clean. blocked or closed. Cylinders and crankcase sweating Refrigerant flood-back. Check refrigerant charge and expansion valves. Copyright by MARINE INVEST POLAND, Gdańsk 2015

High crankcase temperature (should be +71C max. At seal housing Liquid line strainer blocked. Excessive superheat. Compression ratio too high. Discharge temperatures over +135C. Leaking suction or discharge valves. Clean strainer. Adjust expansion valves. Recheck design. Check unit application. Replace valves. Copyright by MARINE INVEST POLAND, Gdańsk 2015

Copyright by MARINE INVEST POLAND, Gdańsk 2015

Troubleshooting Copyright by MARINE INVEST POLAND, Gdańsk 2015

Troubleshooting Filter/Driers Flare connection: Make Type Size Part No. Danfoss DML163 3/8 023Z5043 Danfoss DML 164 ½ 023Z5044 Danfoss DML 305 5/8 023Z0051 Danfoss DML 306 ¾ 023Z0193 Castel 4316/3 3/8 6656009 Castel 4316/4 ½ 6656010 Castel 4332/5 5/8 6656013 Drier Cores: Make Type Part No. Danfoss 48 DU/DM 023U1391 Castel 4490/A 6656060 Solenoid Valve (flare) without coil: Make Type Size Kv-Value Part No. (m3/h) Danfoss EVR-3 ¼ 0.27 032F8107 Danfoss EVR-6 3/8 0.80 032F8072 Danfoss EVR-10 ½ 1.90 032F8095 Danfoss EVR-15 5/8 2.60 032F8101 Danfoss EVR-20 7/8-22mm 5.00 032F1240 Danfoss EVR-20 7/8-22mm 5.00 032F1254 Manual valve Danfoss EVR-25 1.1/8 10.00 032F2200 Manual valve Danfoss EVR-25 1.1/8 10.00 032F2201 (We supply also Castel, Alco, Parker, Saginomiya solenoid valves). Copyright by MARINE INVEST POLAND, Gdańsk 2015

Coil for Solenoid Valve: Make Type Volt(s) Frequency (Hz) Part No. Danfoss Coil 10W 110 50/60 018F6730 Danfoss Coil 10W 220/230 50/60 018F6732 Danfoss Coil 12W 110 50 018F6811 Danfoss Coil 12W 220/230 50 018F6801 Danfoss Coil 12W 110 60 018F6813 Danfoss Coil 12W 220 60 018F6814 (We supply also Castel, Alco, Parker, Saginomiya coils for solenoid valves). Pressure Safety Switches (LP/HP): Make Type Lock LP Lock HP LP. Range (Bar) Diff. (Bar) HP. Range (Bar) Diff. (Bar) Part No. Danfoss KP-1-0.2 / 7.5 0.7 / 4.0 060-110166 Danfoss KP-1 Yes -0.9 / 7.0 lock 0.7 060-110366 Danfoss KP-2-0.2 / 5.0 0.4 / 1.5 060-112066 Danfoss KP-5 8 / 32 1.8 / 6.0 060-117166 Danfoss KP-5 Yes 8 / 32 lock 3 060-117366 Danfoss KP-15 Yes Yes -0.9 / 7.0 lock 0.7 8 / 32 lock 4 060-124566 Danfoss KP-15 Adj. Adj. -0.9 / 7.0 lock 0.7 8 / 32 lock 4 060-122066 (We supply also Johnson Controls, PENN, Saginomiya). Thermostatic Expansion Valves (flare): Make Type Connection(s) Length Ref. Temp (.C) Part No. cap. Danfoss TX-2 3/8 ½ 1.5 m R-22-40 / +10 068Z3206 Danfoss TEX-2 3/8 ½ 1.5 m R-22-40 / +10 068Z3209 Danfoss TS-2 3/8 ½ 1.5 m R-404a -40 / +10 068Z3400 Danfoss TES-2 3/8 ½ 1.5 m R-404a -40 / +10 068Z3403 Danfoss TZ-2 3/8 ½ 1.5 m R-407c -40 / +10 068Z3496 Danfoss TEZ-2 3/8 ½ 1.5 m R-407c -40 / +10 068Z3501 Copyright by MARINE INVEST POLAND, Gdańsk 2015

Thermal Element: Make Type Length cap. Ref. Temp (.C) Part No. Danfoss TEX-5 3.0 m R-22-40 / +10 067B3250 Danfoss TEX-12 3.0 m R-22-40 / +10 067B3210 Danfoss TEX-20 3.0 m R-22-40 / +10 067B3274 Danfoss TEX-55 3.0 m R-22-40 / +10 067G3205 Danfoss TES-5 3.0 m R-404a -40 / +10 067B3342 Danfoss TES-12 3.0 m R-404a -40 / +10 067B3347 Danfoss TES-20 3.0 m R-404a -40 / +10 067B3352 Danfoss TES-55 3.0 m R-404a -40 / +10 067G3301 Danfoss TEZ-5 3.0 m R-407c -40 / +10 067B3278 Danfoss TEZ-12 3.0 m R-407c -40 / +10 067B3366 Danfoss TEZ-20 3.0 m R-407c -40 / +10 067B3371 Danfoss TEZ-55 5.0 m R-407c -40 / +10 067G3240 (We supply also Alco, Saginomiya, Sporlan Expansion Valves). Safety relief valve: Make Type Connection Pressure Part No. Henry 526-CE 3/8 NPT 3/8 flare 20.7 Bar 4901668 Henry 526-CE 3/8 NPT 3/8 flare 24.1 Bar 4901670 Henry 526-CE 3/8 NPT 3/8 flare 27.6 Bar 4901672 Henry 526-CE 3/8 NPT 3/8 flare 31.0 Bar 4901674 Henry 5232A-CE ½ NPT ¾ flare 20.7 Bar 4901656 Henry 5232A-CE ½ NPT ¾ flare 24.1 Bar 4901658 Henry 5232A-CE ½ NPT ¾ flare 25.0 Bar 4901660 Henry 5232A-CE ½ NPT ¾ flare 27.6 Bar 4901662 Henry 5232A-CE ½ NPT ¾ flare 31.0 Bar 4901664 Copyright by MARINE INVEST POLAND, Gdańsk 2015

Orifice for Expansion valves: Make Type Orifice No. Danfoss T/TE-2 00 06 Danfoss TE-5 01 04 Danfoss TE-12 05 06 Danfoss TE-20 08 09 Danfoss TE-55 10 13 (We supply also Alco, Saginomiya, Sporlan Orifices). Copyright by MARINE INVEST POLAND, Gdańsk 2015

Refrigerant: Type- Charge KGs Compressor Manufacturer & type: Oil Manufacturer and type: Oil Separator (Y/N) Make/Model: Y N Serviceable (Y/N): Y N Suction Accumulator (Y/N) Make/Model: Discharge Line OD Size/Material: Suction Line OD Size/Material: Liquid Line OD Size/Material: Motor Volts/Phase/Cycles / Power/Current/RPM: Mounting Foot, Flange or Foot & Flange: Condenser Manufacturer, model & Test Pressure: Relief Valve Manufacturer, Connections & Set Pressure: Drier Manufacture, Type and Flare/Solder/Weld: Expansion Valve Manufacturer & Model: AHU Manufacturer & Model: Evaporator Manufacturer & Model: Y N V- PH- HZ- KW- A- RPM- Bar- Bar- System Parameters: Evaporating T 0 C Condensing T 0 C System Cooling Capacity (KW, Kcal/h or BTU/h): Condenser Cooling (Air/Fresh water/sea water): Pipe run Details: Height- Metres Length- Metres Copyright by MARINE INVEST POLAND, Gdańsk 2015

Discharge Pressure (Bar/PSI) Discharge pipe Temperature at Compressor outlet ( 0 C/ 0 F) Suction Pressure (Bar/PSI) Suction pipe Temperature At Compressor inlet ( 0 C/ 0 F) Compressor Oil Pressure (Bar/PSI) Crankcase Oil Level Crankcase Temperature acondition Inspection of Oil Door (0C/0F) Percentage Load(%) Full Load Amps Running Amps Running Hours Sea Water Temperature ( 0 C/ 0 F) Cooling Water/Air Inlet Temp ( 0 C/ 0 F) Cooling Water/Air Outlet Temp ( 0 C/ 0 F) Liquid Line Temperature at Condenser Outle ( 0 C/ 0 F) Condenser/Receiver Sightglass Level (%) Liquid Line Suction Line Temperature a Expansion Valve Inlet ( 0 C/ 0 F) Temperature at Expansion Valve Location ( 0 C/ 0 F) Suction Pressure At Evaporator Outlet (Bar/PSI) Liquid Line Sightglass Condition Moisture Indicat Air On Evaporator ( 0 C/ 0 F) Air Off Evaporator ( 0 C/ 0 F) Ambient Temp. ( 0 C/ 0 F) Percentage Recirculated Air (%) Air Temp. at Cabin Outlet ( 0 C/ 0 F) Average Cabin Temp. ( 0 C/ 0 F) Thermostat Set Point ( 0 C/ 0 F) Are all fans operating at correct speed and current Evaporator(s) Frost free Cooling/Heating coil(s) clean and fins in good condition (not corroded) Inlet filters installed and clean Copyright by MARINE INVEST POLAND, Gdańsk 2015

NOTES