Attractive, slim, versatile & WITHOUT OUTDOOR UNIT

Similar documents
AIR CONDITIONERS PROFESSIONAL CATALOGUE

MONO & MULTI SPLIT AIR CONDITIONERS

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Inverter Wall Mounted Series

improve your life Today ARGO is a technological and reliable brand, but also a young, dynamic and friendly brand.

Product Line Introduction. Karl Zhang Technical support engineer

THE WORLD S MOST EFFICIENT HEAT PUMP

HEAT PUMPS. Efficient Comfort For Every Season

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Just feel well. 2017/2018 Air conditioning

Air Conditioners. Summer

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Submittal Data Sheet

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

EASY DOES IT. Multiple Fan Speeds with Auto Cool

Pure Efficiency Meets Healthy Living NEW 2013

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS


mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

contents page say goodbye to outdoor units 2-3 unico inverter range 4-5 unico on off range 6-7 unico easy range 8-9

A more comfortable, safe and sustainable world

2 &3-4 Head Multi System

All you can do with iseries

Tower Green HE Hybrid

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Inverter Ducted Air Conditioners

Heat Pumps COMFORT NEED IT. When You

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

A2A, A2W & DHW HEAT PUMP & AIR COND

Air to water Heat Pump System

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

The future is in the air

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

Ducted inverter reverse cycle air conditioning

NEW IN 2008 For both residential and tertiary sectors une avance dans l air du temps* *a step forward into the air of our time

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

American Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

HT V2 HT Split

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

QTS SELECTION TECHNICAL BOOKLET

Air cooled industrial chillers

Elegance and design for your residential comfort

International Markets. Product Catalogue. complementary items

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

Up to SEER 26.1 Wall Mount Heat Pump

Technology DC Inverter = performance, comfort and saving R 410 A. >Several possible combinations : 3 outdoor units and 15 indoor units

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

PRODUCT GUIDE

Technology that works fast. Inverter Ducted Systems

HVS, Hydro Variable System

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Reverse Cycle Split Systems DC Inverter & Fixed Speed

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

manuflow AIR CONDITIONING & HEAT PUMP PRODUCTS SEER 17

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

AIR CONDITIONERS, HEATING & COOLING for your home

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Innovative air conditioning

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

LV Series. SEER 15+ Concealed Built in Heat Pump

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Temperature. In the HVAC area, we talk about two kinds of temperatures.

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

GHE Dehumidifiers for radiant cooling systems with heat recovery

2017 LINE UP MINI SPLITS CATALOG

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Do you want a versatile solution

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

Packaged Terminal Air Conditioners

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Residential and Light Commercial Ductless Systems Catalog

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

OPERATING INSTRUCTIONS

AE/AH R410A Window Air Conditioners & Heat Pumps

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

INVERTER 9-12 DC INVERTER 9 SF

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Integrated VarIable refrigerant flow ahu/pau (r410a)

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Transcription:

Attractive, slim, versatile & WITHOUT OUTDOOR UNIT

MONOBLOCCO RÊVE SINGLE DUCT CONDITIONER CONDENSED Only 2 holes in the wall are needed to connect the air-condensed Rêve model with the outside, as long as the holes are in a perimeter wall. Rêve air/ air houses an outdoor unit within its single case and in order to operate correctly requires a constant exchange of air with the outside because it uses air to cool the condenser. This air exchange takes place via two 16 cm holes (1 intake hole and 1 outflow hole), to be made in the installation wall, which therefore must be a perimeter wall. Thanks to the special grilles the unit can be installed very easily even from indoor the room, through walls or structures up to 2 metres thick or directly onto large windows with no loss of performance... Rêve is also designed to allow recessed wall installation and in this instance its visible depth is reduced to only 10 centimetres. When Rêve operates in cooling mode or dehumidification only, the condensation is released by internal evaporation in the condenser: therefore there is no need to provide a condensation discharge pipe for the cooling-only models. Condensation discharge is however required for models with a heat pump, even though its use is limited to heat pump operation. The condensation can be drawn either indoor or outside the room using the dedicated duct indoor the device s chassis. 16 cm 2 technibel.dk ONLY 26 CM DEPTH

SINGLE DUCT CONDITIONER WATER CONDENSED COP up to 4,68 Can also be installed on non-perimeter walls Rêve water-condensed still eliminates the problem of the outdoor unit by housing it within its single case, but it uses water instead of air to cool the condenser. This solution has the advantage of not requiring holes in the wall and thus allows the device to be installed on any type of wall, perimeter or not. The advantages of this application include: great energy efficiency (COP up to 4.68), low power consumption (630 watts to achieve a heat output of over 3 ) and extremely quiet operation thanks to the fact that the condenser, being water-cooled, has no ventilation system. The water-condensed version of Rêve consumes just one cubic metre of water per day (less than one euro s worth). Unique and special, it provides solutions for niche applications that arise much more often than you may think... From residences in historic buildings with large supplies of water, to systems with cooling towers, heat pumps and/or boilers on closed-circuit loops even when controlled by BMS, such as Lyon Airport. Mains water use Rêve can also operate as a terminal in a closed circuit water loop system with water at 30 C in accordance with EN14511 specifications. The water used to cool the condenser is fed into a circuit and drawn to a cooling tower where it is cooled and then reused by the device. Closed circuit water use Rêve can also operate as a terminal in a closed circuit water loop system with water at 30 C in accordance with EN14511 specifications. The water used to cool the condenser is fed into a circuit and drawn to a cooling tower where it is cooled and then reused by the device. Mains Water Recirculated water key Tap Flow rate valve 0.5 mm mechnical mesh filter Water inlet hose Flow switch Solenoid Water outlet hose Water heat exchanger Water inlet Water outlet technibel.argoclima.com 3

MONOBLOCCO RÊVE WITH HYDRAULIC MODULE AS A RADIATOR SUBSTITUTE A real advantage for on/off versions, both air or water-condensed, is the ability to connect Rêve to a central heating system and use it as a radiator connected to the heating system circuit using the dedicated hydraulic module (optional), which also includes a three-way bypass valve. To use the radiator function Rêve must be connected to the central heating system, whether it is centralised or autonomous. Suitable checks should first be carried out on the system to determine the water flow rate conditions in terms of volume and heat output. The connection can be made using the dedicated optional kit, which in concept represents a kind of interface module between Rêve and the central heating system. Without this kit, Rêve can still be installed with the maximum flexibility as an air conditioner/heat pump without an outdoor unit (for example in places where no central heating system is installed due to climatic conditions). The connection kit to the central heating system is symmetrical and can be fitted on the left or right of the device. It is designed to adapt to various different existing situations (pipes on the right, pipes on the left, delivery on the right and return on the left, delivery above and return below...). This means that the same kit can be used for both sides. The size and shape of the kit elegantly covers most types of hydraulic connection. The kit is comprised of a plastic casing and all the components (electronic and hydraulic) required for radiator operation. The installer need only make the hydraulic connections to the central heating system delivery and return pipes. Installation with the hydraulic module for connection to a boiler Radiator function! 4 www.technibel.dk

RÊVE CONDENSED WATER HEAT PUMP SVPWM 180 full DC inverter technology Heat pump with cool, heat, dehumidify and fan functions Universal multifunction remote control with LCD display, I Feel sensor, wall mount and transmitter with a wide range of operation Temperature check comparison between remote control sensor and unit sensor ifeel function ECO and High Power functions Horizontal deflector with 6 positions set via remote control and iflap function for intelligent air distribution Automatic fan speed and/or three set speeds available via remote control Condensing with variable speed fan Intelligent Cold draft and Defrost functions Additional electrical heating (820 watts) activated by the software in auto mode when the unit is unable to balance the thermal load, or manually activated/deactivated via remote control as a booster for the heat pump or as a Fan Heater Auto-restart following black outs and excess pressure protection devices High efficiency rotary compressor covered by a 5-year warranty Optional feet for floor installation (windows, loft conversions...) COMPLIANT TO REGULATION ERP-ECODESIGN PRODUCT NAME Features Cooling capacity Additional electrical resistance Energy label class E.E.R. / C.O.P. Air flowrate (h.-m.-l.) Dehumidification Fan speeds Sound pressure (h.-m.-l.) Power supply Runnig consumption Annual energy cons. - A/C (500h)-Dir. 2002/31/CE Refrigerant type Ducts diameter Condensate discharge Net weight Net dimension (H./W./D.) EN 14825 Units ABCDEFG (/) m 3 /h litres/h n V/Ph/Hz h mm Kg mm XFETTO RÊVE DCI DCI Cooling Heating 1,85 (1,10-2,93) 2,27 (0,90-3,05) 0,85 A A 2,61 3,17 330-300-280 1,0 3 + Auto 43-38-35 230/1/50 0,710 0,715 355-162 by duct, outside or inside the room 49 735x839x260-280 www.technibel.dk 5

MONOBLOCCO RÊVE RÊVE CONDENSED ON/OFF WATER 247C 237R COOLING ONLY HEAT PUMP Installation on a perimeter wall Automatic switching from cooling to heating action based on the set temperature (235H) Radiator operation when connected to the heating system circuit using the dedicated hydraulic module (optional), which includes a three-way bypass valve Remote control with digital 24h thermostat/timer and up to 4 addresses Dual temperature sensor (on the unit and on the remote control) ifeel & Night functions Horizontal deflector that can be switched between fixed and oscillating positions via remote control Condensing with variable speed outdoor fan for maximum quietness Tangential fan with three programmable speeds or automatic speed control Device that prevents the release of cold air into the room by activating heat pump mode during defrosting cycles (235H) Device that prevents the circulation of air in the room when the heating water temperature is below 40 C in radiator mode Precision thermostat with settings from 6 C to 40 C in radiator mode Auto restart following power black outs Electronic protection against excess pressure High efficiency rotary compressor covered by a 5-year warranty Optional feet for floor installation (windows, loft conversions...) COMPLIANT TO REGULATION ERP-ECODESIGN PRODUCT NAME MRF XFETTO 247245C C5T MRF XFETTO 237235H R5T Features Units Cooling Cooling Heating 2,45 2,35 2,25 Cooling/Heating capacity (A/Conditioner mode) BTU/h 8.360 8.020 7.700 kcal/h 2.110 2.020 1.935 Heating capacity (Water Radiator mode) 2,10 2,10 Energy label class ABCDEFG A A B E.E.R. / C.O.P. (/) 2,62 2,61 2,65 Air flowrate (h.-m.-l.) m³/h 330-300-280 330-300-280 Dehumidification l/h 1,2 1,0 Fan speeds n 3 + Auto 3 + Auto Sound pressure in Air/Conditioner mode (h.-m.-l.) 45-43-41 45-43-41 Sound pressure in Water radiator mode (h.-m.-l.) 42-39-32 42-39-32 Power supply V/Ph/Hz 230/1/50 230/1/50 Running consumption in Air/Conditioner mode 0,935 0,900 0,850 Annual energy cons.- A/C(500h)-Directive 2002/31/EC h 468 450 - Running consumption in Water radiator mode 0,027 0,027 Refrigerant type Ducts diameter mm 162 162 Hydraulic connection diameter on the heating plant (W.R.mode) inch 1/2" 1/2" gas F Condensate discharge not requested by duct, outside or inside the room Condensate drain connection diameter (outside) mm - 18 Net weight Kg 50 52 Net dimensions (H./W./D.) mm 735/839/260-280 735x839x260-280 EN 14825 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC 6 technibel.dk

RÊVE WATER CONDENSED ON/OFF WATER WATER 247CH H2O COOLING ONLY 237RH H2O HEAT PUMP Can be installed on any wall, even non-perimeter walls, because it does not require holes in the wall Designed to work with mains water or a well/groundwater source, it can also operate as a terminal in a closed circuit water loop system with water at 30 C in accordance with EN14511 specifications Very high levels of efficiency (EER up to 4.68) Automatically switches from cooling to heating based on the set temperature (235HP) Operates as a radiator when connected to the heating system circuit using the dedicated hydraulic module (optional), which includes a three-way bypass valve High efficiency plate heat exchanger with a solenoid to cut off mains water circulation when the compressor is off Antifreeze protection on condensation water circuit Installation of a viewable filter on the mains water inlet (to be completed by installer) rmmended Remote control with digital 24h thermostat/timer and up to 4 addresses Dual temperature sensor (on the unit and on the remote control) Dry, Fan Only, ifeel and Night Functions Horizontal deflector that can be switched between fixed and oscillating positions via remote control Washable air filters Tangential fan with three programmable speeds or automatic speed control Device that prevents the release of cold air into the room, in heat pump mode (235HP) Device that prevents the circulation of air in the room when the heating water temperature is below 40 C in radiator mode Precision thermostat with settings from 6 C to 40 C in radiator mode Auto restart following power black outs Electronic protection against excess pressure High efficiency rotary compressor covered by a 5-year warranty Optional feet for floor installation (windows, loft conversions...) PRODUCT NAME MRF XFETTO 247245SCH C5T H2O 2 O XFETTO MRF 237 235HPH R5T H2O 2 O Operation Town water Water loop(*) Town water Water loop(*) Features Units Raffreddamento Cooling Cooling Raffr. Heating Risc. Cooling Raffr. Heating Risc. 2,83 2,7 2,95 3,15 3,00 3,56 Cooling/Heating capacity (Air-Conditioner mode) BTU/h 9.650 9.200 10.060 10.740 10.230 12.140 kcal/h 2.430 2.320 2.540 2.710 2.580 3.060 Energy label class ABCDEFG - B - - A C E.E.R. / C.O.P. (/) 4,42 4,15 4,68 3,80 4,41 4,14 Air flowrate (h.-m.-l.) m³/h 330-300-280 330-300-280 330-300-280 Dehumidification litri/h 1,2 1,2 1,3 1,3 Fan speeds n 3 + Auto 3 + Auto 3 + Auto 3 + Auto Sound pressure in Air-Conditioner mode (h.-m.-l.) 44-42-41 44-42-41 44-42-41 44-42-41 Power supply V/Ph/Hz 230/1/50 230/1/50 Running consumption in Air-Conditioner mode 0,640 0,650 0,630 0,830 0,680 0,860 Annual energy cons.- A/C(500h)-Directive 2002/31/EC h - 325 - - 340 - Water flowrate for the heat exchanger m³/h 0,150 0,525 0,150 0,525 Pressure drops KPa 2,9 38,0 2,9 40,3 Refrigerant type Water connection diameter (in/out) inch 1/2" (gas) F 1/2" (gas) F 1/2" (gas) F 1/2" (gas) F Condensate drain connection diameter (inside or outside) mm 13/18 13/18 13/18 13/18 Heat transferred to water 3,47 3,35 3,58-3,68 - Heat moved from water - - - 2,04-2,7 Heating capacity in Water Radiator mode 2,1 2,1 Running consumption in Water radiator mode 0,027 0,027 Water flowrate in Water Radiator mode m³/h 0,19 0,19 Pressure drops in Water Radiator mode kpa 2,9 2,9 Hydraulic connection diameter to the heating plant (W.R.mode) inch 1/2" F 1/2" (gas) F Sound pressure in Water radiator mode (h.-m.-l.) 42-39-32 42-39-32 Net weight Net dimensions (H./W./D.) Kg 46 48 mm 735/839/260-280 735x839x260-280 Town Mains water water - Cooling: - Cool: Room Amb. Temp. temp. 27 C 27 C d.b. d.b. / 19 C / 19 C w.b. - w.b. - Temp. Water : temp. inlet 18 C in 18 C - outlet - out 36 C 36 C / Heat/ Pump Heat : pump: Room Temp. Amb. 20 C temp. d.b. 20 - C Water d.b. Temp.: - Water inlettemp. 18 C in - outlet 18 C 6 C - out 6 C Water Water loop loop - Cooling: - Cool: Room Amb. Temp temp.. 27 C 27 C d.b. d.b. / 19 C / 19 C w.b. - w.b. Water- Temp.: Water inlet temp. 30 C in 30 C - outlet - out 35 C 35 C / Heat / Heat Pump pump: : RoomAmb. Temp. temp. 20 C d.b. 20 C - Water d.b. Temp - Water temp. 15 C Water Radiator radiator - Amb. - Room temp. Temp. 20 C 20 C- Water - Watertemp. Temp.: in inlet 70 C 70 C- out - outlet 60 C 60 C water loop: standard conditions EN14511 (*) Water loop (EN14511 Definition) Closed circuit of water maintained within a temperature range on which the units in cooling mode reject heat and the units in heating mode take heat technibel.dk 7

702015313-06/2015 TECHNIBEL DENMARK Aircold Vissevej 95 DK-9210 Aalborg technibel.dk aircold@aircold.dk N.B. The manufacturer assumes no responsibility for any errors or inaccuracies in the content of this catalogue, and reserves the right to make any necessary changes to its products, at any time and without notice, for technical or commercial reasons. Technibel is a trademark of Nibe Energy System France used under license