Sensor unit MC2 with analog output for Freon gases and refrigerants

Similar documents
Multi-Gas-Controller MGC2

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Danfoss gas detection units

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

PolyGard 2-channel Gas Controller MGC-03

Danfoss gas detection units

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Controller Module GC-06

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Danfoss gas detection unit Type GD Heavy Duty

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Carbon Monoxide CO Transmitter ADT-X3-1110

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Oxygen (O2) Single-Point Gas Detection System

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

Two-Channel Gas Controller

Danfoss gas detection Controller unit

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Datasheet: K-22 LO Sensor

CMF, CMX & CMA series

Chillgard Refrigerant Monitor

3M Oldham OLCT 100. Description. Fixed Gas Detector

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

Recalibrate the way you look at gas detection

Combustible Gas Detection and Control System

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Catalog 2018 SAFETY FIRST. Fixed Gas Warning Systems for Buildings, Industry and Marine PERFECT SOLUTIONS FOR GAS ALARM SYSTEMS. Version 11.

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

OLC(T) 100 FIXED GAS DETECTOR

Gas cylinder scale Model GCS-1

Duct Air Quality Sensors

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Requirements of refrigerant leak detector and alarm for air conditioning and refrigeration equipment

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

ALTAIR 5X Multigas Detector Product Specification

Carbon Monoxide Transmitter

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Measurement Solutions for Refrigeration Technology.

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Model D12-IR. Digital Gas Transmitter...

SIL 2. Ultima X Series Gas Monitors CERTIFIED

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

PERFECT SOLUTIONS FOR GAS ALARM SYSTEMS. Garage. Gas Alarm, Ventilation and Parking Management for Garages. Version EN SAFETY FIRST

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

VQ500 Series Combustible Gas Detector Elements

Refrigerant Leak Detector Manual

User Manual. PolyGard Single Point Controller SPC Single Point Gas Controller for Combustible Gases Serial Number _E_1008.

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Ammonia Leak Detector Manual

for relative humidity and temperature with calibration certificates

Room Air Quality Sensors

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

DMFPM-2R MULTIFUNCTIONAL

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Dräger Polytron 8700 IR Detection of flammable gases and vapors

COMPACT FLAME CONTROLLER CFC 2000

SAM-MAX Refrigerant Monitors

Duct Temperature Sensors

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

P R O D U C T D ATA S H E E T

QPM21 Series Duct CO 2 and Air Quality Sensors

HCF100 Refrigerant FREON R410A, R134a, R407C, R404A

Analog Room Pressure Monitor RPC Series

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Air Check O 2 Deficiency Monitor 0-25%

P R O D U C T D ATA S H E E T

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Fire control panel detect 3004 plus and accessories

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Inc Series Digital Gas Detector/Controller. Operation Manual

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

COMPACT FLAME CONTROLLER CFC 1000

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Transcription:

Page 1 Dec. 2018 Sensor unit MC2 with analog output for Freon gases and refrigerants Exchangeable sensor unit including digital value processing and self control for the continuous monitoring of the ambient air. The sensor unit MC2 houses a module with µcontroller, analog output and power supply in addition to the semiconductor sensor element including amplifier. The µcontroller calculates a linear 4 20 ma (or 2 10 V) signal out of the measurement signal of the sensor and also stores all relevant measured values and data of the sensor element. Calibration is done either by simply replacing the sensor unit or by using the comfortable, integrated calibration routine directly at the system. APPLICATION The Sensor MC2 is used for the detection of refrigerants and Freon gases when a typical 4 20 ma (or 2 10 V) signal is required. Exchangeable sensor unit in plastic housing without cable FEATURES Digital measurement value processing Internal function control with integrated hardware watchdog Data / measured values in µc of the sensor unit, therefore simple exchange uncalibrated <> calibrated High accuracy, selectivity and reliability Low zero point drift Long sensor life time Hardware & software according to SIL2 compliant development process Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration 4 20 ma (or 2 10 V) analog output with selectable signal output for special mode, fault etc. Reverse polarity protected, overload and short-circuit proof Housing for integration of the sensor unit IP 65 version Display (option) Display with two open-collector outputs for horn (resettable) and warning lamp (option) Conformity to o EN 61010-1 o ANSI/UL 61010 1 o CAN/CSA-C22.2 No. 61010-1) o EN 378 o EN 61508-1-3 o EN 45544-1 Duct mounting kit (accessory) Exchangeable sensor unit in plastic housing with cable 5 m Option housing A with sensor unit in plastic housing

Page 2 Dec. 2018 SPECIFICATIONS Electrical Power supply 16 29 V DC, reverse-polarity protect.; 18-27 V AC (only for output signal 2-10 V) Power consumption 65 ma, max. (1.6 VA for 24 V) Analog output signal Proportional, overload and short-circuit proof, load 500 Ohm for current signal, 50 kohm for voltage signal 4-20 ma or 2 10 V = measuring range 3.2 < 4 ma or 1.6-2 V = underrange > 20-21.2 ma or 10-10.6 V = overrange 2 ma or 1 V = fault > 21.8 ma or 10.9 V = fault High Sensor performance Gas type See Order Information Sensor element Semiconductor sensor Measuring range 20 2000 ppm Repeatability ± 20 % T 90 < 40 Sek. Temperature range -30 C to +50 C (-22 to 122 F) Humidity range 5-95 % RH not condensing Pressure range Atmospheric ± 20 % Sensor life time > 5 years Calibration interval 1 12 months Storage temperature range 0 C to +50 C (32 F to 122 F) Storage time Poisoning 12 months The sensitivity of Pellistor sensors can be influenced by substances containing silicon compounds and even poisoned and destroyed by them. Physical Housing A for integration of the sensor unit Polycarbonate UL 94 V2 Enclosure colour RAL 7032 (light grey) Dimensions (W x H x D) 94 x 130 x 57 mm (3.7 x 5.1 x 2.2 in.) Weight Ca. 0.2 kg Packaging volume Ca. 4.5 l Protection class IP 65 Mounting Wall mounting Pre-embossed entries for cable / sensor unit 6 x M20/M25 Enclosure M25 Polycarbonate UL 94 V2 Enclosure colour RAL 7032 (light grey) Dimensions (D x H) 24 x 22 mm (0.94 x 0.87 in.) Weight Ca. 30 g (0.066 lb) Protection class IP 65 Mounting Screw mounting / M25 Wire connection Screw-type terminal min. 0.25 mm 2, max. 1.3 mm 2,3-pin Directives EMC directives 2014/30/EU CE Compliance with: EN 378 EN 61010-1:2010, ANSI/UL 61010-1 CAN/CSA-C22.2 No. 61010-1 EN 61508-1-3 EN 45544-1 Warranty All specifications were collected under optimal test conditions. 1 year on sensor (not if poisoned or overloaded), 2 years on device

Page 3 Dec. 2018 LCD Display LCD Open-collector (transistor) output (2) Switching capacity Options Two lines, 16 characters each, monochrome For horn (resettable) and warning lamp 24 V DC / 50 ma (+ switching) OVERVIEW FREON GAS TYPES MSR Freon group MSR code Freon type Calibration gas Group Measuring range Relative gas density (air =1) FR02 2061-01 R23 R23 HFC 2000 ppm 2.4 2061-02 R508b R23 HFC 2000 ppm > Air FR03 2063-01 R1234yf R1234yf HFO 2000 ppm > Air 2063-02 R452a R1234yf HFO 2000 ppm > 1 2063-03 R513a R1234yf HCFC 2000 ppm > Air 2063-04 R454c R1234yf HFO 2000 ppm > Air 2063-05 R454a R1234yf HFO 2000 ppm > Air 2063-06 R454b R1234yf HFO 2000 ppm > Air 2063-07 R1234ze R1234yf HFO 2000 ppm > Air FR04 2064-01 R123 R123 HCFC 2000 ppm > Air 2064-02 1233zd R123 HCFC 2000 ppm > Air FR06 2070-01 R22 R22 HCFC 2000 ppm 3 2070-02 R401a R22 HCFC 2000 ppm > Air 2070-03 R401b R22 HCFC 2000 ppm > Air 2070-04 R402a R22 HCFC 2000 ppm > Air 2070-05 R402b R22 HCFC 2000 ppm > Air 2070-06 R403a R22 HCFC 2000 ppm > Air 2070-07 R408a R22 HCFC 2000 ppm > Air 2070-08 R409a R22 HCFC 2000 ppm > Air 2070-09 R411a R22 HFC 2000 ppm > Air FR07 2077-01 R134a R134a HFC 2000 ppm > Air 2077-02 R407a R134a HFC 2000 ppm > Air 2077-03 R416a R134a HFC 2000 ppm > Air 2077-04 R417a R134a HFC 2000 ppm > Air 2077-05 R422a R134a HFC 2000 ppm > Air 2077-06 R422d R134a HFC 2000 ppm > Air 2077-07 R427a R134a HFC 2000 ppm > Air 2077-08 R437a R134a HFC 2000 ppm > Air 2077-09 R438a R134a HFC 2000 ppm > Air 2077-10 R449a R134a HFC 2000 ppm > Air 2077-11 R407f R134a HFC 2000 ppm > Air 2077-12 R450a R134a HFO 2000 ppm > Air FR08 2080-01 R125 R407c HFC 2000 ppm 4.2 2080-02 R32 R407c CFC 2000 ppm 1.8 2080-03 R404a R407c HFC 2000 ppm 3.45 2080-04 R407c R407c HFC 2000 ppm > 1 2080-05 R410a R407c HFC 2000 ppm 2.3 2080-06 R434a R407c HFC 2000 ppm > Air 2080-07 R507a R407c HFC 2000 ppm 3.45 2080-08 R448a R407c HFO 2000 ppm 1.55 2080-09 R452b R407c HFO 2000 ppm > Air 2080-10 R143b R407c HFO 2000 ppm > Air No cross-sensitivity data is available for these sensors. It is well known that all semiconductor sensors are also sensitive to combustible gases, e.g. alcohols, etc.

Page 4 Dec. 2018 ORDER INFORMATION MC2- X S20XX-XX-X - X- X- XX 00 Without connection cable (standard) XX With connection cable: 01, 02, 03, 04, 05 15 max. (length in m) P Sensor housing plastic S Sensor housing stainless steel 0 Without display 1 With display for indication of measurement values (only in housing A or N) 2 With display for values & operation, 2x open-collector for horn & warning lamp (only housing A / N) Gas type Sensor type Measuring range S2061-01-A R23 Semiconductor 20 2000 ppm S2061-02-A R508b Semiconductor 20 2000 ppm S2063-01-A R1234yf Semiconductor 20 2000 ppm S2063-02-A R452a Semiconductor 20 2000 ppm S2063-03-A R513a Semiconductor 20 2000 ppm S2063-04-A R454c Semiconductor 20 2000 ppm S2063-05-A R454a Semiconductor 20 2000 ppm S2063-06-A R454b Semiconductor 20 2000 ppm S2063-07-A R1234ze Semiconductor 20 2000 ppm S2064-01-A R123 Semiconductor 20 2000 ppm S2064-02-A R1233zd Semiconductor 20 2000 ppm S2070-01-A R22 Semiconductor 20 2000 ppm S2070-02-A R401a Semiconductor 20 2000 ppm S2070-03-A R401b Semiconductor 20 2000 ppm S2070-04-A R402a Semiconductor 20 2000 ppm S2070-05-A R402b Semiconductor 20 2000 ppm S2070-06-A R403a Semiconductor 20 2000 ppm S2070-07-A R408a Semiconductor 20 2000 ppm S2070-08-A R409a Semiconductor 20 2000 ppm S2070-09-A R411a Semiconductor 20 2000 ppm S2077-01-A R134a Semiconductor 20 2000 ppm S2077-02-A R407a Semiconductor 20 2000 ppm S2077-03-A R416a Semiconductor 20 2000 ppm S2077-04-A R417a Semiconductor 20 2000 ppm S2077-05-A R422a Semiconductor 20 2000 ppm S2077-06-A R422d Semiconductor 20 2000 ppm S2077-07-A R427a Semiconductor 20 2000 ppm S2077-08-A R437a Semiconductor 20 2000 ppm S2077-09-A R438a Semiconductor 20 2000 ppm S2077-10-A R449a Semiconductor 20 2000 ppm S2077-11-A R407f Semiconductor 20 2000 ppm S2077-12-A R450a Semiconductor 20 2000 ppm S2080-01-A R125 Semiconductor 20 2000 ppm S2080-02-A R32 Semiconductor 20 2000 ppm S2080-03-A R404a Semiconductor 20 2000 ppm S2080-04-A R407c Semiconductor 20 2000 ppm S2080-05-A R410a Semiconductor 20 2000 ppm S2080-06-A R434a Semiconductor 20 2000 ppm S2080-07-A R507a Semiconductor 20 2000 ppm S2080-08-A R448a Semiconductor 20 2000 ppm S2080-09-A R452b Semiconductor 20 2000 ppm S2080-10-A R143b Semiconductor 20 2000 ppm HOUSING FOR INTEGRATION OF THE SENSOR UNIT 0 Without housing A Plastic housing type A, 94 x 130 x 57 mm 5 Stainless steel housing type 5, 113 x 135 x 45 mm D Plastic housing type D, 94 x 65 x 57 mm N Plastic housing type N, 80 x 82 x 55 mm

Digital Output (Option) 4-20mA / 2-10V 0 VDC +24 V ooo P E R F E C T S O L U T I O N S I N G A S A L A R M S Y S T E M S M a d e i n G e r m a n y www.msr-electronic. d e Page 5 Dec. 2018 EXAMPLE R1234yf sensor unit, measuring range 2000 ppm, in plastic housing type A, without display, sensor element in plastic housing without connection cable Order number: MC2-A-S2063-01-A-0-P-00 ACCESSORY: Duct mounting kit Order number: C2-Z2 WIRING CONFIGURATION (including options) MC2-Display DO 2 DO 1 max. 30V / 50mA X2 1 2 3 4 3 2 1 Sensor Unit MC2-X-XXXX Note: The installation of the sensor unit MC2 directly on the MSC2, MGC2 or MSB2 housing isn t-possible, only external connection with separate housing! For 4-20 ma output signal you have to remove the resistor between pin 2 and pin 3.