Chemically active environment

Similar documents
50A KP 70A KP 90A KP 120A KP 150A KP 210A

Orientalmotor Thermal Management

Documentation guide to get your plant on the positive list (Category A1/A2)

Vacuum drying VD VDL series

Winterhalter STF Bavaria. Single-tank flight-type glasswasher for beer mugs and glasses. Powerful performance in large-scale operations

Rules for Intruder Alarm Systems

9. Cooling Water System

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Guide To Troubleshooting INEFFICIENT COOLING FANS

APS-Series 1500VDC OUTDOOR SOLAR INVERTER

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

APS-Series 1000VDC OUTDOOR SOLAR INVERTER

EKA EKA NI EKA NIS EKA NV EKA NV PH EKA NV PTC/PS

EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC/PS

CXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability

manual addendum DELPHI Ex

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Movement by Perfection. The Royal League in ventilation, control and drive technology. Fans for agriculture. Durable, efficient, well designed

Connections, displays and operating elements C D E G H. Installing the control unit

Swedish design and manufacture since 1967

Photovoltaic Cables EN H1Z2Z2-K

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Home Energy Management (Device Control): Immersion Heater Controller Use Cases, Application Note

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Refrigeration Systems Handbook

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

ELECTRICAL QUANTITY WEIGHT (LB)

UltraPleat Technology BURAN REFRIGERATION COMPRESSED AIR DRYER

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

INSTALLATION INSTRUCTIONS ESS 7.0

Vacuum drying oven for non-flammable solvents

ABLOY SENTRY. Security for extreme environments

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TDS Conductivity Probe In-Line conductivity measurement

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Heat recovery systems. For hot air and hot water applications.

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

Operating instructions. Air heater Air Top Evo 40 Air Top Evo 55 for motor homes

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

Multi-Elec COMPACTE BOILER

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

MAC N-407 Air-Cooled Chiller

INSTRUCTIONS FOR USE

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Type approval qualification of Photovoltaic Modules Procedures and test experiences

Process Alarm Module RTA 421

THE CARRIER COMFORT LINE

MEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.

CASE STUDY. It s all about the cut-out

Screw compressors SCK Capacity: m 3 /min

and sanitary hot water Catalogue 2009

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

EVI + INVERTER MODELS A Q U A P U R A

Oil-injected rotary screw compressors GA GA

BURAN REFRIGERATION COMPRESSED AIR DRYER. UltraPleat Technology

ART TEC Solar Differential Temperature Controller DTC-1 Manual

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

VERSAFLOW VORTEX Supplementary instructions

QUANTUM. Series and features of the energy-efficient chiller series

Refrigeration Dryers TG TI Series

Drive or industry-specific package Solutions for hygienic production areas. Motors of the DAS series and ASEPTIC plus Drive Package

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

LPI Lightning Warning System - LWS MKIII

PRODUCT OVERVIEW. Dehumidifiers

RAR... Photocell Detectors. Building Technologies Division

Product Data Sheet Refrigeration Dryer DFX

MULTI ELEC. Electric Boilers TECHNICAL MANUAL

IMC-400A. Product Catalog. Engine Heaters Oil Heaters Controls Accessories

ROTEX Sanicube: Combination of Hot water storage tank and Instantaneous heater. ROTEX Sanicube - The hygienic hot water storage tank. The heating!

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

CX1 ProVector Explosion-Proof Heaters

Hydraulic crimping tool. HO-6 Art convincing solutions

Hot-air generator. Operation manual (Basis operation) TAKETSUNA MANUFACTORY CO., LTD. Please read this without fail before use.

ENCLOSURE COOLING. Glossary

LPI Lightning Warning System (LWS) MKIII

Main technical datas:

Consumer Products Services Germany GmbH Türkheim Germany

LUX Hardwired - Installation Notes

V-Series. Superior Temperature Control for Small Trucks and Vans

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

LPI Lightning Warning System (LWS) MKIII

European Technical Assessment. ETA-03/0032 of 27 August English translation prepared by DIBt - Original version in German language.

About KART. About WULKAN wheel washers.

Operating Instructions

SportChamp SC2. For cleaning and maintaining sand or granulate infilled artificial turf surfaces and other fully synthetic sports surfaces

Safety vacuum drying oven for flammable solvents

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Heating and Air-Conditioning Testing II. Climatic Test Bench

Product Guide Low Voltage Switchboard & Switchgear

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Transcription:

Chemically active environment Ventilation option "Protection against chemically active substances" for SUNNY CENTRAL 400LV, 400HE, 500HE, 630HE Contents This document describes the ventilation option "Protection against chemically active substances". This document is valid for the following Sunny Central models: SC 400LV-11 SC 400HE-11 SC 500HE-11 SC 630HE-11 SC-ChemAkt-UEN0923710 Version 1.0 1/5

Application 1 Application 1.1 Standard ventilation of the Sunny Central The standard design of the Sunny Central is intended for indoor installation and is cooled with ambient air in a service room. The inlet air must satisfy the requirements of classification 3S2. The standard ventilation of the Sunny Central is made directly by the individual switch cabinet units and by the power unit. SMA Solar Technology AG 2/5

Application 1.2 Optional ventilation of the Sunny Central If the Sunny Central is installed in places where the environmental impacts are greater, such as on the coast, the increased salt content of the air can damage individual components in the Sunny Central. Building activities that upgrade the service room where the Sunny Central devices are installed are one possibility for protecting the Sunny Central. Another possibility is to optimize the cooling circuit of the Sunny Central. In the ventilation option "Protection against chemically active substances" an air/air heat exchanger encapsulates the sensitive electronic components from the ambient air. SMA Solar Technology AG 3/5

Performance features 2 Performance features The ventilation option "Protection against chemically active substances" allows the Sunny Central to be used even under adverse ambient conditions. The solution offered encapsulates the sensitive electronic components of the Sunny Central safely away from the outside air, and the Sunny Central fulfills the requirements of classification 3C2 of DIN EN 60721-3-3. 2.1 Scope of the option package The option package includes the following additional properties: A closed cooling circuit of the DC/inverter cabinet An additional seal between the AC cabinet and the DC/inverter cabinet An additional protection for switches, contacts, and relays in the DC cabinet Additional heating to avoid moisture on sensitive components An ambient temperature sensor for power reduction Advantages of this ventilation option Protection of sensitive components of the Sunny Central against corrosion, for example for installation near the sea. Avoidance of dirt and dust deposits in the DC and inverter cabinet. SMA Solar Technology AG 4/5

Performance features 2.2 Technical Data In spite of the capsulation, it is possible to operate the inverters up to 50 C. For the Sunny Central 630HE-11 and Sunny Central 500HE-11 devices, operation with nominal power is possible up to 40 C. For the Sunny Central 400HE-11, operation with nominal power is possible up to 45 C. If higher temperatures occur temporarily because of the installation location, the inverter is protected against overheating by power reduction. The power reduction comes into effect in the range of +40 C to +50 C depending on the inverter type. The following table shows the range limits of the respective devices. SC 400HE-11 SC 500HE-11 SC 630HE-11 Starting temperature of the power reduction 45 C 40 C 40 C End temperature of the power reduction 50 C 50 C 50 C Power reduction in kw / C 20 22.2 31.5 Maximum power at 50 C 300 kw 300 kw 315 kw Nominal power in percent at 50 C 75 60 50 Recommended use of the ventilation option "Protection against chemically active substances" SMA recommends optimizing the ventilation of the Sunny Central in the following cases: Absolutely recommended when the Sunny Central is installed within a 5 km radius of the coast, regardless of the prevailing winds. Absolutely recommended when the Sunny Central is installed within a 5-10 km radius of the coast, when the prevailing winds blow from the sea to the coast. Absolutely recommended when the Sunny Central is installed within a 5-10 km radius of saltworks, salt mines, or salt lakes. Recommended when the Sunny Central is installed within a 50 km radius of the coast, when the prevailing winds blow from the sea to the coast. Recommended when the Sunny Central is installed within a 5-50 km radius of saltworks, salt mines, or salt lakes. SMA Solar Technology AG 5/5