TYP. LUMEN OUTPUT. DRIVE CURRENT (ma) #LED MODULES varies 1000 ~ ~15400 ~ ~ ~7500- ~23000.

Similar documents
TunnelPass LED Tunnel and Underpass Luminaire

Correctional Facility led Lighting

Outdoor Luminaire Controls Guide

HMAO LED. High Mast Series

High Mast Series HMAO HMSC

My Ton CLASP lites.asia meeting 2-3 October 2013 Manila, Philippines. SEAD Street Lighting Tool

Lantern Post Top. LED Series

GranVille II LED. Evolution of a Classic Continues

AVAILABLE THROUGH GRAINGER. LED Fixtures

POLESTAR II SERIES HL /01

AERS. Automatic Energy Reduction System HID lamp control systems for maximum energy savings

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

LED Evolution of a Classic

PoleStar II HOLOPHANE

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Washington Series LED Innovative Tradition Continues

OUTDOOR LIGHTING. Features and Benefits O Distinctive, European style with a sleek design

Eseta. Architectural LED Wall Sconce. Area lighting for outdoor wall-mounted applications.

American National Standard. for Roadway and Area Lighting Equipment Solid State Light Sources Used in Roadway and Area Lighting ANSI C136.

WisDOT Statewide: April 17, LED Retrofit Implementation Plan. Ahmet Demirbilek, PhD, MBA WisDOT BTO Mike Scarmon, PE, PTOE KL Engineering

Arlington. Full Cutoff. Utility Series

Delmarva Power LED Street Light Pilot Project

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

STANFORD UNIVERSITY EXTERIOR LIGHTING

Full Cutoff. Utility Series

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

FET22 (2x2) 25W & 40W Series

Lantern Post Top. LED Series

2013 Catalog. RoHS Western Way, Suite 155 Jacksonville, FL

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

Phillips-Lumileds LEDs Flip Chip Technology Warehouse lighting, Factory lighting, Showroom & Convention centre lighting. 60,000 Hours at L70

Predator LED. Floodlight Luminaires.

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

Global Tech LED 8901 Quality Rd Bonita Springs, FL, Fuel Station Lighting Solutions

GE Evolve Next Generation Roadway Luminaires & Control Solutions. Re-imagining roadways for the future

How Photometric Design Enhances Energy Savings and Asset Management

ACP LED Series. FLoodlight Luminaires. ACP LED Floodlight Luminaires

Navion TM LED Roadway and Area Luminaire

Outdoor Lighting Solutions LED product portfolio. Streetworks

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

LUXCOMFO TM LED Flood Light Datasheet

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

2013 Catalog. RoHS Western Way, Suite 155 Jacksonville, FL

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

E THANOL AND B IODIESEL P LANT L IGHTING S OLUTIONS

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

Bright Ideas. Innovative Solutions. Product Catalog. INDUSTRIAL AND HAZARDOUS Lighting Solutions

LIGHTING PRODUCT GUIDE

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Venture Lighting s Line of LED Solutions. Professional Grade LED from The Leader in HID

Arieta. Architectural LED Area Luminaires AR13, AR18

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Performance Chart Electrical Data

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

Post Top Full Cutoff HID

SUNIDEA CO.,LIMITED.

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

GE Evolve LED Flood & Spot Lighting EFM1

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

M60 LED Recessed Wet Location

Lamp types included. approvals. available with. > 1000W Metal-Halide > 400W - 600W SON-T > 400W CDMT3

American National Standard for Roadway and Area Lighting Equipment Elliptically Shaped, Enclosed Side-Mounted Luminaires

LIST OF PREQUALIFIED ROADWAY LIGHTING SYSTEMS & EQUIPMENT PQL 24.2 REVISED 01/03/17

LED Lighting Product Guide. Winter A portfolio of industry-leading solutions that are changing the way we look at light.

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

M100 My White LED Direct Tunable White

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

LED RETROFIT SOLUTIONS

LED Tube T8 Plug & Play-E-Ballast only

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Major Strides Made by New Crop of Next Generation Luminaires Solid-State Lighting Design Competition Outdoor Winners

Vaya Linear LP, White & Mono

I NTERIOR/OFFICE L IGHTING

Evolve LED Garage Light

SOLID STATE ILLUMINATED RAIL

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Wallpackette III. Wallpackette III

Manufacturing. Industrial Lighting & Controls Solutions

Best Practices for Quality Lighting Renovation Projects

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

New Linear Series DISCONTINUED

High-Mast Lighting A Powerful, New Combination to Save Energy & Reduce Operating Costs

Prismatite 7300 HOLOPHANE. The Prismatite 7300 s rugged and compact

Product Specifications MaxLumen MRI LED Diffused Lighting

Lighting Depth Study. Exterior Departure/Canopy Area

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

LED IMPORTANT SAFETY INSTRUCTIONS

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

Petrolux III. PW Series Wet Locations

Transcription:

Designer Note A: An "x" in the listed part number (which can vary based on options) is a placeholder; specify the complete part number in the Plans. Verify existing and proposed circuit utilization voltages. Designer Note B: For projects with Federal funding, create three illumination designs and list three approved models in the Plan Note, with the phrase "or approved equal." Designer Note C: Design LED lighting to IES RP-8 long-term maintained levels (not initial levels); use the Design Total Light Loss Factor (LLF) listed below for each luminaire Designer Note D: (July 2017) CCT is now required to be 3000K nominal; CCT placeholders may appear in the listing below. Approved list has also been condensed; it no longer lists individual models but gives Product Family and parameter ranges. CONVENTIONAL:, Typ. TYP. LUMEN TOTAL LLF (at 60K Hrs) Rating, Typ. (Type_II Roadway) Navion NVN-Ax-0x-E-U-TxR-10K-7030 129-382 varies 1000 11587-34989 0.84 varies "7030" denotes CCT=3000K Verdeon VERD-A02-E-U-Tx-7030-10K-IP66-4B-AP 92 2 1350 ~9100 0.84 Standard Output model. Verdeon Verdeon VERD-G-Axx-E-U-Tx-7030-10K-IP66-4B-AP VERD-M-Axx-E-U-Tx-7030-10K-IP66-4B-AP 103-143 152-247 2 1350 3-4 3240 ~12000- ~15400 ~15000- ~30000 0.84 varies High Output models. 0.84 varies Very High Output models. G4: use with caution-- any G4 design must meet RP-8 AP Series R2R-mount LE3-Txx-xxx-x-R2R-xx-x-OH 90-270 varies 700 ~7500- ~23000 0.83 varies verify CCT=3000K nominal Leotek E-Cobra ECx-xxM2-xx-WW-x-GY-700-xxx-WL 87-260 varies 700 Leotek Green Cobra GCM-40H-xx-WW-xx-GY-1A-WL 73-135 40 emitters 530-1000 Leotek Green Cobra GCL2-60G-xx-WW-xx-GY-1A-WL 149-208 60 emitters 750-1000 Leotek Green Cobra GC2-96G-xx-WW-xx-GY-1A-WL 226-310 96 emitters 750-1000 ~8000- ~26500 8700-14000 17500-21700 26900-34000 "WW" denotes CCT=3000K B2-U0-G3 ODOT prefers 700mA drive current ODOT prefers 750mA drive current ODOT prefers 750mA drive current. G4: use with caution-- any G4 design must meet RP-8 B3-U0-G4 AEL AEL Autobahn ATBM Autobahn ATBL ATBM-x-xxx-xx-4B-xxx 60-164 3 1000 ATBL-A-xxx-xx-4B-xxx 170-238 - - 7000-17400 18961-27527 B1-U0-G2 0.84 All ATBM models have glass optics B2-U0-G3 0.85 B3-U0-G4 2. G4: use with caution-- any G4 design must meet RP-8 Cree LEDWay HO STR-LWY-XXX-HT-2-F-US-XX-SV-A-30K-SC-UTL 274 2 1000 26388 0.85 B3-U1-G3 1. generally used for new roadway lighting design that requires a large (30') clear pole setback 2. verify CCT=3000K is available before using

GE Evolve ERS-1 ERS1x10xxX30xGRAYxxx 90-161 1 590-920 GE Evolve ERS-2 ERS2x16xxX30xGRAYxxx 132-275 2 590-765 GE ERL2 ERL2xxxxx30xGRAYLRxxx 118-278 2 420-970 GE Evolve ERLH ERLHx10xx30xGRAYLRxxx 90-161 1 590-1020 10000-15000 16000-27000 15000-29000 10000-15000 0.83 0.83 0.88 All Evolve models have a flat glass window and recessed optics B4-U0-G3 Philips Lumec RoadFocus LED Cobra Head RFM108W32LED3K-T-xxx-xxxx-DMG-xxx-SP2-xxx-GY3108-215 varies 700 or 1050 10000-24000 0.84 2. G4: use with caution-- any G4 design must meet RP-8 B3-U0-G4 HueGo SL-01 series SL01-x-xxx-1-xxxGY-xxxxxxx-x30-xx 80-200 2-5 - 8000-20000 0.85 2. verify CCT=3000K before installing

Designer Note A: An "x" in the listed part number is a placeholder; specify the complete part number in the Plans. Verify existing and proposed circuit utilization voltages. Designer Note B: For projects with Federal funding, create illumination design with the phrase "or approved equal." Designer Note C: Design LED lighting to IES RP-8 long-term maintained levels (not initial levels); use the Design Total Light Loss Factor (LLF) listed below for each luminaire Designer Note D: High Mast LED lighting (especially for new design) should utilize ASSYMETRIC DISTRIBUTIONS when possible to maximize utlization and minimize light trespass in both urban and rural areas. Shields should be used for all symmetric-distribution retrofits. Designer Note E: See TEM for design restrictions on light trespass onto agricultural fields. Designer Note F: designers may use lower-lumen versions than those shown (if available) for LOW-MAST lighting HIGH MAST: (typ, Type V) LUMEN (Typ. Type V) TOTAL LLF (at 60K Hrs) Rating (Typ. Type V) Holophane HMLED-2 HMLED2_xx_3K_xx_x_AW Holophane HMLED-3 HMLED3_xx_3K_xx_x_AW varies 1050 varies N/A 252-500 209-634 60000 80000 CHM CONDOR LED CLED-3M-G-30-70-HO-x-xx-xx 386-419 3 850 ~39000- ~44000 GE Evolve HM ERHM-01-x-xx-xx-7-30-x-1-4B-GRAY-R-xxx 350-475 2 430 ~25000- ~55000 0.85 varies Celesteon CST-x-x-x-U-Tx 234-760 varies N/A 90000 A single 8-4 Light Engine version of TypeV will replace two 400W HPS Type V luminaires.

Designer Note A: Designer may use a simplified web-based design tool such as Acuity's Visual Roadway Tool for basic illuminance-based underpass lighting design Designer Note B: Generally, illuminance-based design is used for underpasses. Follow RP-8 standard practice for underpass lighting. Designer Note C: Longer underpasses (~80 feet typically) qualify as TUNNELS and should be designed per RP-22, generally using luminance-based design. Designer Note D: The list below is based on similarity to older HPS luminares per TEM 1142-9 and should be used for most designs. Designers may choose model numbers differing in distribution and power from those below within the same product family, with proper design documentation. Designer Note E: Designer may specify glass optics if desired, but must verify that option is available for each luminaire specified. UNDERPASS: (Typical) TYP. LUMEN (Typ.) TOTAL LLF (at 60K Hrs) Rating, Typ. (Typ.) AR Series B2Emount AR Series F2E mount LE3T4S084EB2E0xSOH 84 3 700 6593 (T4S) 0.83 B1-U0-G2 LE3T4S084EF2E0xSOH 84 3 700 6593 (T4S) 0.83 B1-U0-G2 1. verify CCT=3000K 2. Tiltable. 3. Acrylic optics only. 1. verify CCT=3000K 2. Tiltable. 3. Acrylic optics only. GE Evolve EWS3 EWS3xD3D1301GRAYFxxx 65 1 525 GE Evolve EWNB EWNBxC47301NGRAYFR001 70 1 375 6,500 (Asymmetric Forward) 7,500 (Asymmetric Forward) 0.85 B2-U0-G1 0.85 B1-U0-G2 1. Generally suitable as a drop-in replacement for 100W HPS per TEM 1142-9 2. EWS models with wattage different than shown may be used 3. Glass flat optic protecting acrylic optics 1. Generally suitable as a drop-in replacement for 100W HPS per TEM 1142-9 2. EWNB models with wattage different than shown may be used 3. Glass flat optic protecting acrylic optics Holophane TunnelPass TNLEDx3K7xxWCRDGRAxF1xx 80 3 700 Holophane Wallpack LED W4GLED-10C1000-30K-T3S-xxx-SPD 27-77 NA 700 7232 (Wall Mount Crossbeam) 3206 (T3S) 0.85 B0-U4-G5 B0-U3-G2 1. use screw-down enclosure unless owner specifies latching enclosure 2. Glass optics. 1. typical spacing (27W, Type3Short) for 4- lane underpass 30 feet 2. typical spacing (27W Type3Short) for 3- lane underpass 40 feet 3. "W4G" part number is borosilicate glass

/Cooper WKP LED WKP-6B-LED-E-X-GL-AP-10K-7030-B-DXXX 46 6 140 @480VAC 5883 0.85 B1-U4-G4 "GL" denotes Borosilicate glass option. /Cooper Galleon GWC GWC-AF-0x-LED-xx-xx-xx-7030 85 2 800 8718 (T4FT)