Model GIT 4 Gutter Snow and Ice Melting Control

Similar documents
MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

Installation and Operation Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Model GPT 3 Freeze Protection Thermostat

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SAFETY INFORMATION AND WARNINGS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ADDITIONAL INFORMATION

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

SC-40 Satellite Contactor

SAFETY INFORMATION AND WARNINGS

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

PROJECT MANAGEMENT Transmittal No 17D

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Warranty Info: ETI s warranty policy can be viewed at:

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Gardian W51. Approvals

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

FPC-02 Series. Installation and Operating manual

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

FLCH4R Garage and Utility Electric Heater

Installation, Operation & Service Manual

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Getting Started Quick Reference Guide

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Installation Guide for models:

Getting Started Quick Reference Guide

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Spa Control System OWNER S MANUAL

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

Installation Instructions

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Manual No: Revision: C. Overfill Alarm. Installation Guide

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

SOLARLOK Interconnection System Installation Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

GCW SERIES Gas Cylinder Warmers

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

INSTALLATION MANUAL CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) MODEL CERV-001-PARTA, CERV-001-PARTB

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Installation Instructions

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Installation Guide for models:

DS-8C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

Effective May 2017 Supersedes October 1998 (S )

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

SERIES PSE-690 INSTALLATION & OPERATION MANUAL IMPORTANT: PSE-690 REMOTE STROBE POWER SUPPLY

Installation Instructions

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

(HSTAT Series) Instruction Manual

Static Pressure Alarm For Hazardous Location Fume Hoods

IceStop System Installation and Operation Manual

Installation Instructions

Installation Instructions

M Series Fan Filter Units

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

MODELS 304GC, 304GCX, 314GC, and 314GCX

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Liebert InteleCool Warranty Inspection Check Sheet

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

SP-1000X. Panic Device Power Controller Installation Guide. Rev

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Installation Instructions

Installation Guide Soil, Asphalt & Concrete De-icing Heating Ribbons

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

CHAPTER 20 SERVICE EQUIPMENT

Fuel Management System Setup Guide

Manifold Installation Controller MIC-180. Installation and Operation Instructions

GAS MONITOR Model Model

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Transcription:

We manage heat Model GIT 4 Gutter Snow and Ice Melting Control Part Number 19556 Installation and Operation Manual WARNING Hazard of electrical shock. Follow all safety procedures. Any installation involving electric heater wiring must be grounded to earth to protect against shock and fire hazard. Suitable ground fault detection and interrupting systems must be in use at all times to reduce shock and fire hazard and to protect equipment. Electric wiring to heating elements must be installed in accordance with Article 110.3B, Article 210.8(A)(3), Article 250.4(A), Article 426.4 & 28, Article 725.55 and all other applicable sections of the National Electric Code (NFPA 70), local electrical codes, and any third party standards. Only qualified personnel trained in electrical equipment service should perform maintenance on heating and control equipment. Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 www.networketi.com

DISCLAIMER Environmental Technology, Inc. makes no representations or warranties, either expressed or implied, with respect to the contents of this publication or the products that it describes, and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Environmental Technology, Inc. reserves the right to revise this publication and to make changes and improvements to the products described in this publication without the obligation of Environmental Technology, Inc. to notify any person or organization of such revisions, changes or improvements. Copyright 2008 Environmental Technology, Inc. All rights reserved. No part of this manual may be reproduced or translated in any form or by any means, electronic or mechanical including photocopying and recording, for any purpose without the express written consent of Environmental Technology, Inc. The ETI logo and We Manage Heat are reg is tered trademarks of En vi ron men tal Technology, Inc. GIT is a trademark of En vi ron men tal Tech nol o gy, Inc. Printed in USA PN19592 rev G 11/2009

Description The computerized UL and CUL Listed GIT 4 automatically controls gutter and downspout snow and ice melting heaters. It is safety tested to Standard 873 for Temperature Indicating and Regulating Equipment. The GIT 4 includes the GFEP (ground fault equipment protection) required by the NEC. The GIT 4 consists of sensor and control assemblies connected by a 12' (3.6 m) cable. The sensor meets the NEC (National Electrical Code) low voltage Class 2 requirement for wet locations. The GIT 4 requires an RCU 2 Remote Control Unit which is included. The RCU 2 provides remote control and monitoring of the GFEP function. It also permits operating the snow and ice melting heaters for a fixed time at temperatures below 38 F (3.3 C). Supply Voltage Options The GIT 4 provides jumper-selected supply voltage options of 120, 208 through 240, and 277 volts. Selecting the proper supply voltage is very important. An incorrect setting may destroy the GIT 4 or render it inoperative. The GIT 4 operates from the heater supply voltage. Relay (Contactor) Contact Ratings The relay (contactor) provides a Form A (SPST) contact rated for up to 26 amp AC heater loads at voltages at or below 277 volts. Safety Any installation involving electric heater wiring must be grounded to earth to protect against shock and fire hazard. Suitable ground fault detection and interrupting systems must be in use at all times to reduce shock and fire hazard and to protect equipment. Electric wiring to heating elements must be installed in accordance with Article 110.3B, Article 210.8(A)(3), Article 250.4(A), Article 426.4 & 28, Article 725.55 and all other applicable sections of the National Electric Code (NFPA 70), local electrical codes, and any third party standards. Follow the installation instructions contained herein and those provided by the heater manufacturer. If you have questions concerning the installation contact Customer Service for assistance. The use of a GIT 4 with integral GFEP satisfies the NEC requirement for GFEP on each branch circuit connected to the snow and ice melting system. Clearly label each circuit breaker with its function. This is vitally important when there is more than one point of disconnect. Make certain that the heater shield is properly grounded as required by the NEC. Installing the Sensor Mount the sensor as low as possible in the gutter about a foot upstream of the downspout. For proper operation, the heating cable must be close to but not touching the sensor. A separation of 1 / 2 " (1.3 cm) to 1" (2.5 cm) is ideal. Orient the sensor with the temperature sensor facing upstream and the moisture sensor toward the down spout. Use the supplied plastic mounting straps and gasketed #10 fasteners to secure the sensor in the gutter via 3 / 16 " drilled holes through the gutter. See Figure 1.

Installing the Control Lethal voltages are present within the control enclosure during operation. Some installations may require two points of disconnect. Tag all circuit breakers off during installation or service. The GIT 4 comes factory set for 277 volt operation. A jumper located in the control must be changed for 120 or 208 through 240 volt operation. See Figure 2. An incorrect setting may destroy the GIT 4 or render it inoperative. The control comes connected to the sensor with 12 feet (3.6 meter) of three conductor cable. The snow and ice melting heater leads, supply leads and sensor leads terminate in the control enclosure. Locate the control enclosure outdoors at a place convenient for the wiring connections. Position the control housing so that the sensor cable entry is positioned at the right of the housing, heater leads exit to the left and the supply leads enter at the bottom. Failing to orient the housing correctly may cause moisture collection in the housing resulting in equipment damage. For line supply and load connections use #10 AWG or larger wires rated for at least 194 F (90 C). Figures 4 and 5 show wiring for typical 120/240 volt residential applications and unbalanced 208 or 277 3-phase applications. Installing the RCU 2 The RCU 2 is an NEC Class 2 device. It can be located up to 150 feet (46 meters) from the control. Use customer supplied #18 AWG 2-conductor jacketed cable. Choose a convenient protected indoor location. The RCU 2 mounts in a single gang switch box. The wiring connections to the RCU 2 are not polarity sensitive and connect to the two blue wires in the low voltage section of the control enclosure. Jam Nut Sensor Nut Gutter Nylon Clamp Drill 3 / 16 " Hole 2 Places Screw O-ring Figure 1. Sensor mounting

ENVIRONMENT ALTECHNOLOGY, INC. SOUTHBEND, INDIANAU.S.A. 277V Connection Shown 12' Jacketed Cable Conduit South Bend, Indiana Environmental Techno NAME 120V 208/240V 277V Line / Line 1 Neutral / Line 2 Equipment Ground 120V 208/240V 277V 120V 208/240V 277V 120V Connection 208V thru 240V Connection Figure 2. Selecting Voltage.81" (20.6mm) Removable Mounting Clamp Clearance for #10 Screw Heated Moisture Sensing Grid Ambient Air Temperature Sensor 1.12" (28.5mm) 12' (3.6m) Jacketed 3 Conductor #18 AWG Cable 5.56" (141.2mm) 1.50" (38.1mm) 7 7 / 16 " (189mm) 2.75" (69.9mm) 4 1 / 4 " (108mm) 4.50" (114.3mm) RCU 2 3/4"(21mm) Conduit Entry Figure 3. Mounting Dimensions

LINE / LINE 1 GIT-4 CONTROL HIGH HEATER 120 / 240 VOLT SUPPLY (GFEP PROTECTED) ELECTRONICS NEUTRAL / LINE 2 SAFETY GROUND RETURN RED GIT-4 SENSOR SHIELD Figure 4. Typical 120/220 Volt Residential Applications 208 / 277 GI T- 4 CONTROL HIGH HEA TER 208 OR 277 VO LT 3-PHASE SUPPL Y (GFEP PROTECTED) ELECTRONICS 208 / NEUTRAL SAFETY GROUND RETURN RED GI T- 4 SENSOR SHIELD Figure 5. Unbalanced 208 or 277 3-Phase Applications Post Installation Tests Thoroughly check the system before placing it in service. Our experience shows that installation errors cause the majority of problems. Frequently encountered problems include wiring errors and improper waterproofing. Simple electrical tests and visual inspections identify these problems. Checking the sensor in the field is not practical. Verifying its operation requires special test equipment that is neither portable nor commonly available. Checking the operation of the control requires a clamp-on AC ammeter. Follow the steps below to verify operation. The gutter and downspout must be dry while doing these tests. 1. Remove power from the snow and ice melting system. There may be two points of disconnect. 2. Remove the cover from the GIT 4 controller. 3. Clamp the ammeter to one of the yellow leads in the GIT 4 controller. 4. Apply power to the snow and ice melting system. This may require two points of connection. Use care. Lethal voltages are now present withing the control enclosure. The ammeter should read approximately zero amps. 5. At the RCU 2 remote control, press the HEATER TOGGLE switch momentarily. The HEATER indicator should operate. If the SUPPLY and HEATER indicators flash alternatively, a GFEP condition or a GFEP circuit failure exists. 6. At the GIT 4 controller, the ammeter should read the nominal heater current. 7. At the RCU 2 remote control, press the HEATER TOGGLE switch momentarily. The HEATER indicator should turn off. 8. At the GIT 4 controller, the ammeter should read zero amps.

9. Remove the ammeter from the GIT 4 controller. 10. Replace the cover on the GIT 4 controller. 11. Apply power to the snow and ice melting system. This may require two points of connection. Checking the system function requires moisture and a cold source. If the temperature is already below 38 F (3.3 C) then simplying appling a small amount of moisture (such as a damp, clean paper towel) should energize the heaters. If the temperature is above 38 F (3.3 C) then the temperature probe needs to be brought down below 38 F (3.3 C) using freeze spray or crushed ice before appling a small amount of moisture (such as a damp, clean paper towel). Operating Instructions The GIT 4 does not require user intervention during normal operation. The green SUPPLY indicator operates to show that power is applied to the system. The yellow HEATER indicator operates while the heaters are operating or enabled to operate. In some installations drifting and blowing snow may present a problem if this does not occur at the sensor. In this case, press the HEATER CYCLE switch to energize the heaters for one hour to melt accumulated snow. Repeat as required after each one hour period until accumulated snow and ice are melted. Semi-monthly Routine Testing Press the TEST/RESET switch to test the GIT 4 GFEP for proper functioning. The SUPPLY and HEATER indicators flash alternately for a few seconds during testing. The RCU 2 flashes these indicators if the test fails. Pressing the TEST/RESET switch will not clear this condition. If the test fails, the GIT 4 will not operate the snow and ice melting system heaters. You need to have a qualified electrician fix the problem. If the snow and ice melting system is operating normally, there is no need for this test. Press the HEATER TOGGLE switch momentarily. The HEATER indicator should operate. After a few seconds, press the HEATER TOGGLE switch again. The HEATER indicator should turn off. If the SUPPLY and HEATER indicator flash alternately, a GFEP failure exists. You need to have a qualified electrician fix the problem. Maintenance Although the GIT 4 does not require routine maintenance, make certain that the gutters and down spouts are cleaned each fall to ensure efficient gutter and down spout snow and ice melting system efficiency. For technical help, questions or comments concerning this product or any Environmental Technology, Inc. prod ucts contact the Customer Service Department between 8:00am and 5:00pm EST (UTC minus fi ve hours) at: E-mail: helpdesk@networketi.com